Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Pacing Clin Electrophysiol ; 24(4 Pt 1): 456-64, 2001 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-11341082

RESUMO

The purpose of this prospective randomized study was to compare the safety and efficacy of the cephalic approach versus a contrast-guided extrathoracic approach for placement of endocardial leads. Despite an increased incidence of lead fracture, the intrathoracic subclavian approach remains the dominant approach for placement of pacemaker and implantable defibrillator leads. Although this complication can be prevented by lead placement in the cephalic vein or by lead placement in the extrathoracic subclavian or axillary vein, these approaches have not gained acceptance. A total of 200 patients were randomized to undergo placement of pacemaker or implantable defibrillator leads via the contrast-guided extrathoracic subclavian vein approach or the cephalic approach. Lead placement was accomplished in 99 of the 100 patients randomized to the extrathoracic subclavian vein approach as compared to 64 of 100 patients using the cephalic approach. In addition to a higher initial success rate, the extrathoracic subclavian vein medial approach was determined to be preferable as evidenced by a shorter procedure time and less blood loss. There was no difference in the incidence of complications. In conclusion, these results demonstrate that lead placement in the extrathoracic subclavian vein guided by contrast venography is effective and safe. It was also associated with no increased risk of complications as compared with the cephalic approach. These findings suggest that the contrast-guided approach to the extrathoracic portion of the subclavian vein should be considered as an alternative to the cephalic approach.


Assuntos
Desfibriladores Implantáveis , Eletrodos Implantados , Marca-Passo Artificial , Flebografia , Idoso , Idoso de 80 Anos ou mais , Análise de Falha de Equipamento , Segurança de Equipamentos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Músculos Peitorais/irrigação sanguínea , Estudos Prospectivos , Veia Subclávia/diagnóstico por imagem , Resultado do Tratamento
2.
Circulation ; 101(11): 1237-42, 2000 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-10725281

RESUMO

BACKGROUND: Certain genetic mutations associated with hypertrophic cardiomyopathy (HCM) carry an increased risk of sudden death. QT variability identifies patients at a high risk for sudden death from ventricular arrhythmias. We tested whether patients with HCM caused by beta-myosin heavy-chain (beta-MHC) gene mutations exhibit labile ventricular repolarization using beat-to-beat QT variability analysis. METHODS AND RESULTS: We measured the QT variability index and heart rate-QT interval coherence from Holter monitor recordings in 36 patients with HCM caused by known beta-MHC gene mutations and in 26 age- and sex-matched controls. There were 7 distinct beta-MHC gene mutations in these 36 patients; 9 patients had HCM caused by the malignant Arg(403)Gln mutation and 8 patients had HCM caused by the more benign Leu(908)Val mutation. The QT variability index was higher in HCM patients than in controls (-1.24+/-0.17 versus -1. 58+/-0.38, P<0.01), and the greatest abnormality was detected in patients with the Arg(403)Gln mutation (-0.99+/-0.49 versus -1. 46+/-0.43 in controls, P<0.05). In keeping with this finding, coherence was lower for the entire HCM group than for controls (P<0. 001). Coherence was also significantly lower in patients with the Arg(403)Gln mutation compared with controls (P<0.05). CONCLUSIONS: These findings suggest that (1) patients with HCM caused by beta-MHC gene mutations exhibit labile repolarization quantified by QT variability analysis and, hence, may be more at risk for sudden death from ventricular arrhythmias, and (2) indices of QT variability may be particularly abnormal in patients with beta-MHC gene mutations that are associated with a poor prognosis.


Assuntos
Cardiomiopatia Hipertrófica/genética , Mutação , Cadeias Pesadas de Miosina/genética , Adulto , Sequência de Aminoácidos/genética , Criança , Eletrocardiografia , Eletrofisiologia , Feminino , Frequência Cardíaca , Humanos , Masculino , Isoformas de Proteínas/genética , Valores de Referência , Fatores de Tempo
3.
Pacing Clin Electrophysiol ; 23(2): 203-13, 2000 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-10709228

RESUMO

The aim of this study was to compare the lesions created using a multipolar microcatheter (MICRO) ablation system in the right canine atrium to a pullback approach with a standard radiofrequency (STND RF) ablation and to determine the value of electrogram amplitude and pacing threshold in predicting transmurality of lesions. Ten dogs underwent right atrial ablation using a MICRO (6 dogs) or STND RF (4 dogs) ablation system in each animal. Attempts were made to create linear RF lesions at four predetermined atrial sites. RF energy was delivered for 60 seconds using closed-loop, temperature control to achieve a target temperature of 60 degrees C for STND RF and 50 degrees C for MICRO. Unipolar atrial electrogram amplitude and atrial pacing threshold were obtained before and after ablation. Pathological analysis was determined at 4 weeks after ablation. Lesions created with MICRO were narrower, more likely to be continuous, and more likely to be anchored to an anatomic structure than those lesions which were created using a STND RF. No difference was observed in overall lesion length or in the proportion of lesions that were transmural over at least 50% of their length. Of lesions created using MICRO, a significant relation was observed between transmurality of lesion and unipolar electrogram amplitude as well as pacing threshold. Further studies are needed to determine if this type of ablation technique and parameters during ablation may facilitate a successful catheter-based MAZE procedure.


Assuntos
Ablação por Cateter/métodos , Animais , Fibrilação Atrial/patologia , Fibrilação Atrial/terapia , Estimulação Cardíaca Artificial , Cães , Eletrocardiografia , Seguimentos , Átrios do Coração/patologia , Estudos Prospectivos
4.
J Cardiovasc Electrophysiol ; 10(6): 874-86, 1999 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-10376927

RESUMO

Vasovagal syncope is a common disorder of autonomic cardiovascular regulation that can be very disabling and result in a significant level of psychosocial and physical limitations. The optimal approach to treatment of patients with vasovagal syncope remains uncertain. Although many different types of treatment have been proposed and appear effective based largely on small nonrandomized studies and clinical series, there is a remarkable absence of data from large prospective clinical trials. However, based on currently available data, the pharmacologic agents most likely to be effective in the treatment of patients with vasovagal syncope include beta blockers, fludrocortisone, and alpha-adrenergic agonists. In this article, we provide a summary of the various therapeutic options that have been proposed for vasovagal syncope and review the clinical studies that form the basis of present therapy for this relatively common entity.


Assuntos
Síncope Vasovagal/terapia , Agonistas alfa-Adrenérgicos/uso terapêutico , Antagonistas Adrenérgicos beta/uso terapêutico , Adulto , Estimulação Cardíaca Artificial , Disopiramida/uso terapêutico , Feminino , Fludrocortisona/uso terapêutico , Humanos , Parassimpatolíticos/uso terapêutico , Inibidores Seletivos de Recaptação de Serotonina/uso terapêutico , Síncope Vasovagal/diagnóstico , Síncope Vasovagal/fisiopatologia
5.
J Cardiovasc Electrophysiol ; 9(9): 899-908, 1998 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-9786070

RESUMO

INTRODUCTION: Recent studies have implicated repolarization lability in the genesis of malignant ventricular arrhythmias. However, few data exist on assessment of temporal QT interval variability and its relation to arrhythmogenesis. We tested the ability of the QT variability index (QTVI), a measure of beat-to-beat QT interval fluctuations measured on a single ECG lead, to identify patients presenting with malignant ventricular arrhythmias and predict their subsequent occurrences. METHODS AND RESULTS: We measured the QTVI in 95 patients presenting for electrophysiologic study (EPS). The ability of the QTVI to identify patients with sudden cardiac death (SCD) or sustained monomorphic ventricular tachycardia (MVT) on presentation and during follow-up of 23.7+/-14.3 months was compared with spatial QT dispersion, T wave alternans ratio during atrial pacing, MVT inducibility at EPS, signal-averaged ECG, heart rate variability, and ejection fraction. The QTVI was higher in patients with heart disease than in controls (-0.7+/-0.7 vs -1.1+/-0.5, P < 0.05), and higher in patients presenting with SCD than in other patients with heart disease (0.0+/-0.6 vs -0.8+/-0.5, P < 0.05). The QTVI was the only clinical variable that identified patients who presented with SCD (P = 0.004, odds ratio = 12.5) on stepwise, logistic multiple regression. Fourteen patients had arrhythmic events during follow-up. In a Kaplan-Meier analysis of arrhythmic events, QTVI> or =0.1 was a discriminator for higher risk of arrhythmic events (P < 0.05). CONCLUSIONS: (1) This noninvasive measure of temporal repolarization lability identified patients with SCD and predicted arrhythmia-free survival. (2) Further studies are needed to determine the mechanisms that mediate beat-to-beat QT interval variability.


Assuntos
Morte Súbita Cardíaca/patologia , Eletrocardiografia , Taquicardia Ventricular/diagnóstico , Feminino , Seguimentos , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Estudos Retrospectivos , Fatores de Risco , Sensibilidade e Especificidade , Taxa de Sobrevida , Taquicardia Ventricular/mortalidade , Taquicardia Ventricular/fisiopatologia
6.
Pacing Clin Electrophysiol ; 18(7): 1450-4, 1995 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-7567600

RESUMO

Dual chamber (DDD) pacing improves symptoms and relieves left ventricular (LV) outflow obstruction in hypertrophic cardiomyopathy. The ventricular lead is usually positioned at the right ventricular apex (RVA). We report a patient in whom the ventricular lead had inadvertently penetrated the septum, resulting in DDD pacing from the LV apex. However, after 3 months, obstruction was reduced and symptoms were improved. Pacing from LV apex and RVA resulted in comparable hemodynamic improvement. This case suggests that the asynchronous wave of septal contraction, originating from the apex, irrespective of ventricular site, accounts for the reduction in LV outflow obstruction.


Assuntos
Estimulação Cardíaca Artificial , Cardiomiopatia Hipertrófica/terapia , Obstrução do Fluxo Ventricular Externo/complicações , Adulto , Eletrocardiografia , Humanos , Masculino , Obstrução do Fluxo Ventricular Externo/terapia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...