Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Health Phys ; 126(5): 272-279, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38526245

RESUMO

ABSTRACT: Previous studies have shown that measuring changes in electrical impedance that follow radiation-induced suppression of metabolic activity in irradiated yeast cells can be used to determine radiation dose. The current work investigates the radiation response of Saccharomyces cerevisiae cells by using metabolic activity of cells as a damage indicator. Impedance biodosimetry was examined as a method to evaluate the radiation response of yeast cells. Active lab-grade dry yeast cells were used as the biological material as these samples are simple to handle and have a long shelf-life. A novel dosimeter design has been developed with a strict fabrication method and measurement procedure to ensure reproducible measurements are possible. Prepared yeast samples were irradiated to doses from 0.5 to 8 Gy using a 137Cs source, and a dose response curve was developed that showed a linear relationship of dose with changes in impedance measurements. Fading of the impedance signal was also investigated, and it was shown that there was no noticeable fading of the impedance signal over a period of 7 mo. Finally, the lowest detectable limit measured using this methodology was determined to be 300 mGy. This work presents an alternative retrospective dosimetry technique that can be used at a high scale and low cost following large-scale radiological accidents.


Assuntos
Radioisótopos de Césio , Saccharomyces cerevisiae , Impedância Elétrica , Estudos Retrospectivos
2.
Viruses ; 14(4)2022 03 25.
Artigo em Inglês | MEDLINE | ID: mdl-35458414

RESUMO

Recent research using UV radiation with wavelengths in the 200-235 nm range, often referred to as far-UVC, suggests that the minimal health hazard associated with these wavelengths will allow direct use of far-UVC radiation within occupied indoor spaces to provide continuous disinfection. Earlier experimental studies estimated the susceptibility of airborne human coronavirus OC43 exposed to 222-nm radiation based on fitting an exponential dose-response curve to the data. The current study extends the results to a wider range of doses of 222 nm far-UVC radiation and uses a computational model coupling radiation transport and computational fluid dynamics to improve dosimetry estimates. The new results suggest that the inactivation of human coronavirus OC43 within our exposure system is better described using a bi-exponential dose-response relation, and the estimated susceptibility constant at low doses-the relevant parameter for realistic low dose rate exposures-was 12.4 ± 0.4 cm2/mJ, which described the behavior of 99.7% ± 0.05% of the virus population. This new estimate is more than double the earlier susceptibility constant estimates that were based on a single-exponential dose response. These new results offer further evidence as to the efficacy of far-UVC to inactivate airborne pathogens.


Assuntos
COVID-19 , Coronavirus Humano OC43 , Desinfecção/métodos , Humanos , SARS-CoV-2 , Raios Ultravioleta , Inativação de Vírus
3.
Sci Rep ; 11(1): 19930, 2021 10 07.
Artigo em Inglês | MEDLINE | ID: mdl-34620923

RESUMO

Transmission of SARS-CoV-2 by aerosols has played a significant role in the rapid spread of COVID-19 across the globe. Indoor environments with inadequate ventilation pose a serious infection risk. Whilst vaccines suppress transmission, they are not 100% effective and the risk from variants and new viruses always remains. Consequently, many efforts have focused on ways to disinfect air. One such method involves use of minimally hazardous 222 nm far-UVC light. Whilst a small number of controlled experimental studies have been conducted, determining the efficacy of this approach is difficult because chamber or room geometry, and the air flow within them, influences both far-UVC illumination and aerosol dwell times. Fortunately, computational multiphysics modelling allows the inadequacy of dose-averaged assessment of viral inactivation to be overcome in these complex situations. This article presents the first validation of the WYVERN radiation-CFD code for far-UVC air-disinfection against survival fraction measurements, and the first measurement-informed modelling approach to estimating far-UVC susceptibility of viruses in air. As well as demonstrating the reliability of the code, at circa 70% higher, our findings indicate that aerosolized human coronaviruses are significantly more susceptible to far-UVC than previously thought.


Assuntos
Coronavirus Humano 229E/efeitos da radiação , Infecções por Coronavirus/prevenção & controle , Coronavirus Humano OC43/efeitos da radiação , Desinfecção/métodos , Raios Ultravioleta , Inativação de Vírus/efeitos da radiação , Aerossóis/isolamento & purificação , Microbiologia do Ar , COVID-19/prevenção & controle , Simulação por Computador , Coronavirus Humano 229E/isolamento & purificação , Coronavirus Humano 229E/fisiologia , Coronavirus Humano OC43/isolamento & purificação , Coronavirus Humano OC43/fisiologia , Desinfecção/instrumentação , Desenho de Equipamento , Humanos , Modelos Biológicos
4.
Sci Rep ; 10(1): 19659, 2020 11 12.
Artigo em Inglês | MEDLINE | ID: mdl-33184316

RESUMO

There are increased risks of contracting COVID-19 in hospitals and long-term care facilities, particularly for vulnerable groups. In these environments aerosolised coronavirus released through breathing increases the chance of spreading the disease. To reduce aerosol transmissions, the use of low dose far-UVC lighting to disinfect in-room air has been proposed. Unlike typical UVC, which has been used to kill microorganisms for decades but is carcinogenic and cataractogenic, recent evidence has shown that far-UVC is safe to use around humans. A high-fidelity, fully-coupled radiation transport and fluid dynamics model has been developed to quantify disinfection rates within a typical ventilated room. The model shows that disinfection rates are increased by a further 50-85% when using far-UVC within currently recommended exposure levels compared to the room's  ventilation alone. With these magnitudes of reduction, far-UVC lighting could be employed to mitigate SARS-CoV-2 transmission before the onset of future waves, or the start of winter when risks of infection are higher. This is particularly significant in poorly-ventilated spaces where other means of reduction are not practical, in addition social distancing can be reduced without increasing the risk.


Assuntos
COVID-19/transmissão , Desinfecção/métodos , SARS-CoV-2/efeitos da radiação , Raios Ultravioleta , Ar Condicionado , COVID-19/epidemiologia , Desinfecção/normas , Humanos , Modelos Estatísticos , Ventilação
5.
Sci Rep ; 9(1): 19591, 2019 12 20.
Artigo em Inglês | MEDLINE | ID: mdl-31862995

RESUMO

Concerns about the effects of global warming provide a strong case to consider how best nuclear power could be applied to marine propulsion. Currently, there are persistent efforts worldwide to combat global warming, and that also includes the commercial freight shipping sector. In an effort to decarbonize the marine sector, there are growing interests in replacing the contemporary, traditional propulsion systems with nuclear propulsion systems. The latter system allows freight ships to have longer intervals before refueling; subsequently, lower fuel costs, and minimal carbon emissions. Nonetheless, nuclear propulsion systems have remained largely confined to military vessels. It is highly desirable that a civil marine core not use soluble boron for reactivity control, but it is then a challenge to achieve an adequate shutdown margin throughout the core life while maintaining reactivity control and acceptable power distributions in the core. High-thickness ZrB2 150 µm Integral Fuel Burnable Absorber (IFBA) is an excellent burnable poison (BP) candidate for long life soluble-boron-free core. However, in this study, we want to minimize the use of 150 µm IFBA since B-10 undergoes an (n, α) capture reaction, and the resulting helium raises the pressure within the plenum and in the cladding. Therefore, we have considered several alternative and novel burnable BP design strategies to minimize the use of IFBA for reactivity control in this study: (Case 1) a composite BP: gadolinia (Gd2O3) or erbia (Er2O3) with 150 µm thickness ZrB2 IFBA; (Case 2) Pu-240 or Am-241 mixed homogeneously with the fuel; and (Case 3) another composite BP: Pu-240 or Am-241 with 150 µm thickness ZrB2 IFBA. The results are compared against those for a high-thickness 150 µm 25 IFBA pins design from a previous study. The high-thickness 150 µm 25 IFBA pins design is termed the "IFBA-only" BP design throughout this study. We arrive at a design using 15% U-235 fuel loaded into 13 × 13 assemblies with Case 3 BPs (IFBA+Pu-240 or IFBA+Am-241) for reactivity control while reducing 20% IFBA use. This design exhibits lower assembly reactivity swing and minimal burnup penalty due to the self-shielding effect. Case 3 provides ~10% more initial (beginning-of-life) reactivity suppression with ~70% less reactivity swing compared to the IFBA-only design for UO2 fuel while achieving almost the same core lifetime. Finally, optimized Case 3 assemblies were loaded in 3D nodal diffusion and reactor model code. The results obtained from the 3D reactor model confirmed that the designed core with the proposed Case 3 BPs can achieve the target lifetime of 15 years while contributing to ~10% higher BOL reactivity suppression, ~70% lower reactivity swings, ~30% lower radial form factor and ~28% lower total peaking factor compared to the IFBA-only core.

6.
Acta Biomater ; 6(11): 4439-46, 2010 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-20541630

RESUMO

Implant-derived material from metal-on-metal (MOM) hip arthroplasties may be responsible for an unexplained tissue inflammatory response. The chemical form of the metal species in the tissues is predominantly chromium (Cr), but the currently used techniques have not been able to determine whether this is Cr(III) phosphate or Cr(III) oxide. The analytical challenge must overcome the fact that the metal in the tissues is at a relatively low concentration and tissue preparation or the microscopy beam used can affect the results. Microfocus X-ray spectroscopy using a synchrotron beam is useful in addressing both these issues. Using this technique we compared tissue from failed MOM hips with: (1) tissue from metal-on-polyethylene (MOP) hips; (2) chemical standards; (3) metal discs cut from MOM hips. The most abundant implant-related species in all MOM hip tissues contained Cr. Comparison with standards revealed the chemical form was Cr(III) phosphate, which did not vary with manufacturer type (four types analysed) or level of blood metal ions. Cobalt (Co) and molybdenum (Mo) were occasionally present in areas of high Cr. Co was normally found in a metallic state in the tissue, while Mo was found in an oxidized state. The variety of metallic species may have arisen from corrosion, wear or a combination of both. No evidence of Cr(VI) was seen in the tissues examined.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Metais/química , Falha de Prótese , Artefatos , Cromo/análise , Cobalto/análise , Fluorescência , Humanos , Imageamento por Ressonância Magnética , Microscopia Eletrônica de Transmissão , Pessoa de Meia-Idade , Molibdênio/análise , Padrões de Referência , Espectroscopia de Infravermelho com Transformada de Fourier , Espectroscopia por Absorção de Raios X , Raios X
7.
J Synchrotron Radiat ; 16(Pt 6): 818-24, 2009 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-19844019

RESUMO

The design and performance of the microfocus spectroscopy beamline at the Diamond Light Source are described. The beamline is based on a 27 mm-period undulator to give an operable energy range between 2 and 20.7 keV, enabling it to cover the K-edges of the elements from P to Mo and the L(3)-edges from Sr to Pu. Micro-X-ray fluorescence, micro-EXAFS and micro-X-ray diffraction have all been achieved on the beamline with a spot size of approximately 3 microm. The principal optical elements of the beamline consist of a toroid mirror, a liquid-nitrogen-cooled double-crystal monochromator and a pair of bimorph Kirkpatrick-Baez mirrors. The performance of the optics is compared with theoretical values and a few of the early experimental results are summarized.


Assuntos
Próteses e Implantes/efeitos adversos , Síncrotrons/instrumentação , Titânio/efeitos adversos , Espectroscopia por Absorção de Raios X/métodos , Corrosão , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...