J Extra Corpor Technol ; 50(4): 260-264, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30581236

RESUMO

Low cardiac output syndrome and the systemic inflammatory response are consequences of the cardiac surgical perioperative course. The mechanisms responsible are multifactorial, but recent studies have shown that nitric oxide (NO) may be a key component in mitigating some of these processes. Following on from literature reports detailing the use of inhaled NO added to the gas phase of the extracorporeal circuit, we set about developing a technique to perform this addition safely and efficiently. In the setting of cardiopulmonary bypass, the technique was validated in a randomized prospective trial looking at 198 children. The benefits observed in this trial then stimulated the incorporation of NO into all extracorporeal life support (ECLS) circuits. This required additional hardware modifications all of which were able to be performed safely. Initial results from the first series of ECLS patients using NO also appear promising.


Assuntos
Ponte Cardiopulmonar , Oxigenação por Membrana Extracorpórea , Humanos , Óxido Nítrico , Estudos Prospectivos
2.
Methods Mol Biol ; 992: 155-67, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23546712

RESUMO

The standard assay for monitoring anticoagulation during extracorporeal life support (ECLS) is the activated clotting time (ACT) test, with celite, kaolin, and glass beads being the most commonly used activators to initiate contact activation. The point-of-care ACT test has been the preferred test in catheterization labs and cardiac theatres because it has a number of advantages over laboratory tests (Spinler et al., Ann Pharmacother 39(7-8):1275-1285, 2005): Shorter time between sampling and results. Smaller blood sample size. Availability to have test performed by non-lab personnel. Reduced errors associated with sample mislabeling/mishandling. Decreased risk of sample degradation with time. There are other coagulation monitoring tests available; however these are usually specific and do not take into account the global picture of the entire clotting system. The standard coagulation tests (prothrombin time (PT), activated partial thromboplastin time, thrombin time (TT), and fibrinogen level) are plasma tests measuring plasma haemostasis and not patient haemostasis. The ACT measurement uses whole blood, thereby incorporating the importance of platelets and phospholipids in the role of coagulation. Many of the problems with the haemostatic system during ECLS are caused by the activation of platelets, which are not detected by standard tests. Because an ACT test is nonspecific there are many variables such as hypothermia, platelets, aprotinin, GP IIb/IIIa antagonists, haemodilution, etc. that can alter its results. For this reason it is important to gain an understanding as to how these variables interact for meaningful interpretation of the ACT test result.


Assuntos
Coagulação Sanguínea , Tempo de Coagulação do Sangue Total , Anticoagulantes , Terra de Diatomáceas , Vidro , Hemostáticos , Humanos , Caulim
3.
ASAIO J ; 57(6): 522-6, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21970981

RESUMO

In recent years, there has been a trend to incorporate arterial filters into cardiopulmonary bypass (CPB) oxygenators. The FX oxygenators are the first examples of integrating a filter around the fibers of the oxygenator. To assess the efficacy of the FX05 oxygenator, in comparison with our existing CPB setup (RX05 oxygenator + arterial filter), we randomly assigned 40 patients undergoing CPB, with calculated flows <1.5 L/min, to FX05 or RX05 + arterial filter (19 FX and 21 RX). Embolic load was assessed using the emboli detection and classification quantifier, with sensors placed prefilter and postfilter/oxygenator at identical distances for both devices. A total of 6,270 FX readings and 6,183 RX readings were obtained. Because of the extremely skewed nature of the data, the prefilter embolic volumes were divided into deciles, and each decile was analyzed separately. Our results show that the devices perform similarly; both filter out a high percentage of the prefilter embolic load. Our data support that in the clinical setting, the FX05 is as effective at removing emboli as the RX05 with an arterial filter (CXAF02) which, in conjunction with the prime volume reduction and circuit simplification, has warranted our conversion to the FX series of oxygenators.


Assuntos
Ponte Cardiopulmonar/efeitos adversos , Ponte Cardiopulmonar/instrumentação , Dispositivos de Proteção Embólica , Embolia Aérea/prevenção & controle , Oxigenadores , Filtração/instrumentação , Humanos
4.
Perfusion ; 25(5): 313-20, 2010 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-20630918

RESUMO

During extracorporeal life support (ECLS), blood is exposed to a myriad of unphysiological factors that can affect outcome. One aspect of this is the sub-atmospheric pressure generated by the ECLS pump and imparted to blood elements along the pump inlet line. This pressure can be measured on the inlet line close to the pump head by adding a connector, or at the venous cannula connection site. We compared the two measurement sites located at both points; between the venous cannula-inlet tubing and inlet tubing-pump, with a range of cannulae and flows. We also investigated the effects on inlet pressure from pump afterload and increasing inlet tubing length.


Assuntos
Circulação Extracorpórea , Coração Auxiliar/normas , Pressão , Cateterismo , Desenho de Equipamento , Humanos , Pesos e Medidas
5.
Perfusion ; 21(2): 121-5, 2006 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-16615691

RESUMO

A 13-year-old girl presented to the emergency department with fatigue, headaches and muscle stiffness after returning from a family camping trip. Within 24 h, she was transferred to ICU with general oedema and low saturations, where she had a cardio-respiratory arrest and was placed on veno-arterial extracorporeal membrane oxygenation (ECMO). The patient was successfully supported with ECMO for profound myocardial dysfunction and haemofiltration for rhabdomyolysis and acute renal failure. Patients who present with profound myocardial dysfunction and myoglobinuria as a consequence of viral infection can be successfully supported with ECMO.


Assuntos
Oxigenação por Membrana Extracorpórea/métodos , Influenza Humana/complicações , Cuidados para Prolongar a Vida , Miosite/complicações , Rabdomiólise/complicações , Injúria Renal Aguda/etiologia , Injúria Renal Aguda/terapia , Adolescente , Feminino , Humanos , Influenza Humana/terapia , Miosite/terapia , Rabdomiólise/terapia , Resultado do Tratamento
6.
Perfusion ; 21(1): 39-44, 2006 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-16485698

RESUMO

Increasing perioperative haemoglobin level by reducing priming volume and maintaining a safe cardiopulmonary bypass (CPB) system is the aim of every perfusionist. In this study, we have compared the two membrane oxygenators and pump systems used for paediatric bypass at the Royal Children's Hospital on a regular basis since 1988. We looked at all patients who had the Cobe VPCML (Cobe Laboratories, Denver, CO, USA) and Terumo RX-05 (Terumo Corporation, Tokyo, Japan) oxygenators used for flows from 800 mL/min up to the maximum rated flow for the respective oxygenator from January 2002 until March 2004. The VPCML refers to using only the 0.4-m2 section of the oxygenator. The pump systems used were the Stöckert CAPS (Stöckert Instrumente GmbH, Munich, Germany) and Jostra HL 30 (Jostra AB, Lund, Sweden). Changing from the VPCML to the RX-05 resulted in a 37% reduction in priming volume. The introduction of the Jostra HL 30 with a custom-designed mast system reduced the priming volume by another 15%. This change in priming volume allowed a significant increase, from 6 to 34%, in the percentage of patients who received bloodless primes, and for those patients who received blood primes, an increase in haemoglobin (Hb) on bypass from 8.2 to 9.6 g/dL, on average.


Assuntos
Ponte Cardiopulmonar/instrumentação , Oxigenadores , Ponte Cardiopulmonar/métodos , Desenho de Equipamento , Hemoglobinas , Humanos , Sensibilidade e Especificidade