Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Clin Chem Lab Med ; 59(2): 315-323, 2020 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-33001847

RESUMO

Objectives: Hepcidin measurement advances insights in pathophysiology, diagnosis, and treatment of iron disorders, but requires analytically sound and standardized measurement procedures (MPs). Recent development of a two-level secondary reference material (sRM) for hepcidin assays allows worldwide standardization. However, no proficiency testing (PT) schemes to ensure external quality assurance (EQA) exist and the absence of a high calibrator in the sRM set precludes optimal standardization. Methods: We developed a pilot PT together with the Dutch EQA organization Stichting Kwaliteitsbewaking Medische Laboratoriumdiagnostiek (SKML) that included 16 international hepcidin MPs. The design included 12 human serum samples that allowed us to evaluate accuracy, linearity, precision and standardization potential. We manufactured, value-assigned, and validated a high-level calibrator in a similar manner to the existing low- and middle-level sRM. Results: The pilot PT confirmed logistical feasibility of an annual scheme. Most MPs demonstrated linearity (R2>0.99) and precision (duplicate CV>12.2%), although the need for EQA was shown by large variability in accuracy. The high-level calibrator proved effective, reducing the inter-assay CV from 42.0% (unstandardized) to 14.0%, compared to 17.6% with the two-leveled set. The calibrator passed international homogeneity criteria and was assigned a value of 9.07±0.24 nmol/L. Conclusions: We established a framework for future PT to enable laboratory accreditation, which is essential to ensure quality of hepcidin measurement and its use in patient care. Additionally, we showed optimized standardization is possible by extending the current sRM with a third high calibrator, although international implementation of the sRM is a prerequisite for its success.


Assuntos
Hepcidinas/sangue , Acreditação , Coleta de Amostras Sanguíneas , Calibragem , Cromatografia Líquida de Alta Pressão , Ensaio de Imunoadsorção Enzimática , Humanos , Laboratórios/normas , Garantia da Qualidade dos Cuidados de Saúde/normas , Controle de Qualidade , Padrões de Referência , Espectrometria de Massas em Tandem
2.
Cytotherapy ; 22(9): 486-493, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32565131

RESUMO

PURPOSE: The prevalence of connective tissue progenitor cells within a cell-based therapy is often quantified using the colony-forming unit fibroblast (CFU-F) assay. The present study investigates the feasibility of using cryopreserved bone marrow aspirate concentrate (BMAC) as an alternative cell source to fresh BMAC for CFU-F quantification. METHODS: Freshly prepared and corresponding cryopreserved BMAC samples from patients receiving autologous cell therapy (n = 98) were analyzed using the CFU-F assay for comparison. Cultures were established by directly plating BMAC at low cell densities and maintained for a 2-week growth period. Colonies were enumerated to determine CFU-F frequency, and a subset of cultures was imaged and analyzed to quantify colony area and density. RESULTS: A nonlinear relationship was observed between plating density and CFU-F frequency over a wide range in plating densities (~30-fold). Cryopreserved BMAC yielded recoverable (77 ± 23%) and viable (73 ± 9%) nucleated cells upon thawing. After cryopreservation, CFU-F frequencies were found to be significantly lower (56.6 ± 34.8 vs. 50.3 ± 31.7 colonies per million nucleated cells). Yet the number of CFU-F in fresh and cryopreserved BMAC were strongly correlated (r = 0.87) and had similar area and densities. Further, moderate correlations were observed between the number of CFU-F and nucleated cells, and both the mean colony area and density were negatively correlated with patient age. Notably, no relationship was found between CFU-F frequency and age, regardless of whether fresh or cryopreserved BMAC was used. CONCLUSIONS: Freshly prepared and cryopreserved BMAC yielded correlated results when analyzed using the CFU-F assay. Our findings support the cryogenic storage of patient BMAC samples for retrospective CFU-F analyses, offering a potential alternative for characterizing BMAC and furthering our understanding of progenitor cells in relation to clinical outcome.


Assuntos
Células da Medula Óssea/citologia , Medula Óssea/metabolismo , Ensaio de Unidades Formadoras de Colônias/métodos , Criopreservação , Fibroblastos/citologia , Adolescente , Adulto , Idoso , Contagem de Células , Núcleo Celular/metabolismo , Sobrevivência Celular , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Células-Tronco/citologia , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...