Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Biosens Bioelectron ; 180: 113114, 2021 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-33676163

RESUMO

Heart failure (HF) is the number one cause of death in the world. B-type natriuretic peptide (BNP) is a recognized biomarker for HF and can be used for early detection. Field effect transistor (FET) biosensors have the ability to sense BNP in much shorter times than conventional clinical studies. The lowest limit of detection (LOD) of state-of-the-art HF FET biosensors is 100 fM and detection ranges are short, being less than 4 orders of magnitude. In this work, a B/N co-doped graphene oxide (GO) gel (BN-GO) was used as the channel material in an FET biosensor targeting BNP. The sensor was able to sense BNP in as little as 2 min, with an LOD as low as 10 aM and a wide linear detection range of 10 aM-1 µM, stretching over 11 orders of magnitude. The biosensor showed great selectivity and minimal response towards K+ and OH- ions and the human epidermal growth factor receptor (HER2) protein. This biosensor serves as a proof-of-concept of the ability of BN-GO gel FETs to be used for ultrasensitive biosensors.


Assuntos
Técnicas Biossensoriais , Grafite , Insuficiência Cardíaca , Humanos , Transistores Eletrônicos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...