Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Mech Behav Biomed Mater ; 112: 104081, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32961392

RESUMO

The purpose of this study is the mechanical characterization of the mid-to- old-age human anterior lens capsules (ALCs) obtained by capsulorhexis using Atomic Force Microscopy (AFM) and a nanoindenter at different spatial scales. The dependencies on the human age, presence or absence of pseudoexfoliation syndrome (PEX), and application of trypan blue staining during the surgery were analyzed. The measurements on both the anterior (AS) and epithelial (ES) sides of the ALC were conducted and the effect of cells present on the epithelial side was carefully accounted for. The ES of the ALC had a homogenous distribution of the Young's modulus over the surface as shown by the macroscale mapping with the nanoindenter and local AFM indentations, while the AS was more heterogeneous. Age-related changes were assessed in groups ranging from the mid-age (from 48 years) to old-age (up to 93 years). We found that the ES was always stiffer than the AS, and this difference decreased with age due to a gradual decrease in the Young's modulus of the ES and an increase in the modulus of the AS. No significant changes were found in the mechanical properties of ALCs of PEX patients versus the PEX-free group, as well as in the properties of the ALC with and without trypan blue staining.


Assuntos
Síndrome de Exfoliação , Cápsula do Cristalino , Envelhecimento , Corantes , Humanos , Microscopia de Força Atômica , Pessoa de Meia-Idade , Coloração e Rotulagem , Azul Tripano
2.
J Refract Surg ; 26(7): 520-4, 2010 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-19894669

RESUMO

PURPOSE: To propose a new approach for the study of corneal biomechanics using the Reichert Ocular Response Analyzer (ORA) database, which is based on changes in velocity retardation in the central cornea at the peak of flattening. METHODS: The ORA applanation curve was analyzed using a mathematical technique, which allowed calculation of the elasticity coefficient (Ke), which is primarily characteristic of the elastic properties of the cornea. Elasticity coefficient values were obtained in patients with presumably different biomechanical properties of the cornea: "normal" cornea (71 eyes, normal group), keratoconus (34 eyes, keratoconus group), LASIK (36 eyes, LASIK group), and glaucoma with elevated and compensated intraocular pressure (lOP) (38 eyes, glaucoma group). RESULTS: The mean Ke value in the normal group was 11.05 +/- 1.6, and the corneal thickness correlation coefficient r2 was 0.48. In the keratoconus group, the mean Ke value was 4.91 +/- 1.87 and the corneal thickness correlation coefficient r2 was 0.47. In the LASIK group, Ke and r2 were 5.99 +/- 1.18 and 0.39, respectively. In the glaucoma group, the same eyes that experienced a two-fold reduction in lOP developed a statistically significant reduction in the Ke (1.06 times lower), whereas their corneal hysteresis value increased 1.25 times. CONCLUSIONS: The elasticity coefficient calculated using the ORA applanation curve can be used in the evaluation of corneal biomechanical properties.


Assuntos
Córnea/fisiopatologia , Elasticidade/fisiologia , Ceratocone/fisiopatologia , Miopia/fisiopatologia , Hipertensão Ocular/fisiopatologia , Adolescente , Adulto , Idoso , Fenômenos Biomecânicos/fisiologia , Humanos , Pressão Intraocular , Ceratomileuse Assistida por Excimer Laser In Situ , Pessoa de Meia-Idade , Miopia/cirurgia , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA