Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 53
Filtrar
1.
Radiologia (Engl Ed) ; 64(6): 525-532, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36402538

RESUMO

INTRODUCTION AND OBJECTIVES: Obtaining CCTA images with optimal injection location such as the arm or leg is important to avoid the artifacts caused by the CM. This study compares the computed tomography (CT) numbers and visualization scores of the three-dimensional (3D) images of the lumens of the blood vessels in the arm or leg during cardiac computed tomography angiography (CCTA) in neonatal and infant patients. PATIENTS OR MATERIALS AND METHODS: Between January 2017 and January 2020, 253 consecutive patients were considered for inclusion. We used the estimated propensity scores as a function of the demographic data, including age, body weight, and injection location (right or left side) in the arm (n = 58) and leg (n = 58) of neonatal and infant patients. We compared the mean CT numbers of the pulmonary artery, ascending aorta, and left superior vena cava; contrast-noise ratios (CNR); and visualization scores between the arm and leg as the injection locations. RESULTS: The mean CT numbers during CCTA for the arm and leg were 479.4 and 461.3 HU in the ascending aorta, 464.2 and 448.1 HU in the pulmonary artery, and 232.8 and 220.1 HU in the left superior vena cava, respectively. The mean image noise (SD) and CNR values, respectively, were 38.9 HU and 12.1 for the arm as the injection location and 39.1 HU and 12.3 for the leg as the injection location. The median visualization scores of volume rendering of the 3D images were 3.0 and 3.0 for the arm and leg injection sites, respectively. There were no significant differences in the mean CT numbers of the ascending aorta, pulmonary artery, and left superior vena cava; SD value; CNR; and visualization scores between the arm and leg injection locations. CONCLUSIONS: The CT numbers of the lumen of the blood vessel and visualization scores of the 3D images of the arm and leg injection locations are equal during CCTA in neonatal and infant patients with congenital heart disease.


Assuntos
Meios de Contraste , Veia Cava Superior , Humanos , Lactente , Recém-Nascido , Braço/diagnóstico por imagem , Perna (Membro) , Tomografia Computadorizada por Raios X/métodos
2.
Radiography (Lond) ; 28(4): 906-911, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35785641

RESUMO

INTRODUCTION: This study aims to predict endoleak after endovascular aneurysm repair (EVAR) using machine learning (ML) integration of patient characteristics, stent-graft configuration, and a selection of vessel lengths, diameters and angles measured using pre-operative computed tomography angiography (CTA). METHODS: We evaluated 1-year follow-up CT scans (arterial and delayed phases) in patients who underwent EVAR for the presence or absence of an endoleak. We also obtained data on the patient characteristics, stent-graft selection, and preoperative CT vessel morphology (diameter, length, and angle). The extreme gradient boosting (XGBoost) for the ML system was trained on 30 patients with endoleaks and 81 patients without. We evaluated 5217 items in 111 patients with abdominal aortic aneurysms, including the patient characteristics, stent-graft configuration and vascular morphology acquired using pre-EVAR abdominal CTA. We calculated the area under the curve (AUC) of our receiver operating characteristic analysis using the ML method. RESULTS: The AUC, accuracy, 95% confidence interval (CI), sensitivity, and specificity were 0.88, 0.88, 0.79-0.97, 0.85, and 0.91 for ML applying XGBoost, respectively. CONCLUSIONS: The diagnostic performance of the ML method was useful when factors such as the patient characteristics, stent-graft configuration and vessel length, diameter and angle of the vessels were considered from pre-EVAR CTA. IMPLICATIONS FOR PRACTICE: Based on our findings, we suggest that this is a potential application of ML for the interpretation of abdominal CTA scans in patients with abdominal aortic aneurysms scheduled for EVAR.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Algoritmos , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Aortografia/métodos , Prótese Vascular , Angiografia por Tomografia Computadorizada , Endoleak/diagnóstico por imagem , Endoleak/cirurgia , Humanos , Aprendizado de Máquina , Stents , Tomografia Computadorizada por Raios X , Resultado do Tratamento
4.
Radiography (Lond) ; 28(3): 766-771, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35428572

RESUMO

INTRODUCTION: The purpose of this study was to demonstrate that dose reduction does not compromise image quality when combining high helical pitch (HP) and the ECG-Edit function during low HP retrospectively gated computed tomography angiography (CTA). METHODS: This study made use of a pulsating cardiac phantom (ALPHA 1 VTPC). The heart rate (HR) of the cardiac phantom was changed in five intervals, every 5 beats per minute (bpm), from 40 to 60 bpm. Evaluation of a range of HR was important because data loss might occur when combining a low HR and high HP. We performed retrospectively gated CTA scans five times using a low HP (0.16) and high HP (0.24), for each of the five HR intervals, using a 64-detector row CT scanner. The CT volume dose index (CTDIvol) was recorded from the CT console of each scan. For the images with data loss, data were repaired using the ECG-Edit function. We compared the CTDIvol, estimated cardiac phantom volume, and the visualization of the coronary ladder phantom between HP 0.16, with or without repaired HP 0.24, using the ECG-Edit function. RESULTS: Data loss occurred with a HR of 40 bpm and 45 bpm when using HP 0.24. The CTDIvol was reduced by approximately 33% with HP 0.24 when compared with HP 0.16. There were no significant differences in the mean cardiac motion phantom volume and visualization scores between HP 0.16 and with and without repaired HP 0.24 using the ECG-Edit function (p < 0.05). CONCLUSION: The ECG-Edit function is potential useful for repairing the lost data in patients with a low HR, and when combined with a high HP, it is possible to reduce the radiation dose by approximately 33%. IMPLICATIONS FOR PRACTICE: The ECG-Edit function and high HP may be a viable option in pediatric CTA studies.


Assuntos
Angiografia por Tomografia Computadorizada , Eletrocardiografia , Criança , Angiografia Coronária/métodos , Redução da Medicação , Eletrocardiografia/métodos , Humanos , Doses de Radiação , Estudos Retrospectivos
5.
Radiography (Lond) ; 28(2): 440-446, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-34844859

RESUMO

INTRODUCTION: To investigate how changing the injection duration at cardiac computed tomography angiography (CCTA) affects contrast enhancement in newborns and infants. METHODS: Included were 142 newborns and infants with confirmed congenital heart disease who underwent CCTA between January 2015 and December 2018. In group 1 (n = 71 patients), the injection duration was 8 s; in group 2 (n = 71) it was 16 s. Our findings were assessed by one-to-one matching analysis to estimate the propensity score of each patient. We compare the CT number for the pulmonary artery (PA), ascending aorta (AAO), left superior vena cava (SVC), AAO and PA enhancement ratio, and the scores for visualization between the two groups. RESULTS: In group 1, median CT number and ranges was 345 (211-591) HU in the AAO, 324 (213-567) HU in the PA, and 62 (1-70) HU in the SVC. These values were 465 (308-669) HU, 467 (295-638) HU, and 234 (67-443) HU, respectively, in group 2 (p < 0.05). The median score for volume-rendering visualization on 3D images of the CCTA was 2 in group 1 and 3 in group 2; the score for visualization of the left SVC of the maximum intensity projection images was 2 in group 1 and 3 in group 2 (p < 0.05). The CT number for the AAO and PA enhancement ratio was 15.2 in group 1 and 9.2 in group 2 (p < 0.05). CONCLUSION: The 16-sec injection protocol yielded significantly higher CT numbers for the AAO, PA, and the SVC than the 8-sec injection protocol; the visualization scores were also significantly higher in group 2. IMPLICATIONS FOR PRACTICE: In newborns and infants, the longer injection time for CCTA yields stable and higher contrast enhancement at identical CM concentrations.


Assuntos
Angiografia por Tomografia Computadorizada , Veia Cava Superior , Angiografia por Tomografia Computadorizada/métodos , Meios de Contraste , Humanos , Lactente , Recém-Nascido , Artéria Pulmonar/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Veia Cava Superior/diagnóstico por imagem
6.
Radiography (Lond) ; 28(1): 61-67, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34404578

RESUMO

INTRODUCTION: Deep learning approaches have shown high diagnostic performance in image classifications, such as differentiation of malignant tumors and calcified coronary plaque. However, it is unknown whether deep learning is useful for characterizing coronary plaques without the presence of calcification using coronary computed tomography angiography (CCTA). The purpose of this study was to compare the diagnostic performance of deep learning with a convolutional neural network (CNN) with that of radiologists in the estimation of coronary plaques. METHODS: We retrospectively enrolled 178 patients (191 coronary plaques) who had undergone CCTA and integrated backscatter intravascular ultrasonography (IB-IVUS) studies. IB-IVUS diagnosed 81 fibrous and 110 fatty or fibro-fatty plaques. We manually captured vascular short-axis images of the coronary plaques as Portable Network Graphics (PNG) images (150 × 150 pixels). The display window level and width were 100 and 700 Hounsfield units (HU), respectively. The deep-learning system (CNN; GoogleNet Inception v3) was trained on 153 plaques; its performance was tested on 38 plaques. The area under the curve (AUC) obtained by receiver operating characteristic analysis of the deep learning system and by two board-certified radiologists was compared. RESULTS: With the CNN, the AUC and the 95% confidence interval were 0.83 and 0.69-0.96, respectively; for radiologist 1 they were 0.61 and 0.42-0.80; for radiologist 2 they were 0.68 and 0.51-0.86, respectively. The AUC for CNN was significantly higher than for radiologists 1 (p = 0.04); for radiologist 2 it was not significantly different (p = 0.22). CONCLUSION: DL-CNN performed comparably to radiologists for discrimination between fatty and fibro-fatty plaque on CCTA images. IMPLICATIONS FOR PRACTICE: The diagnostic performance of the CNN and of two radiologists in the assessment of 191 ROIs on CT images of coronary plaques whose type corresponded with their IB-IVUS characterization was comparable.


Assuntos
Aprendizado Profundo , Placa Aterosclerótica , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/patologia , Humanos , Redes Neurais de Computação , Placa Aterosclerótica/diagnóstico por imagem , Estudos Retrospectivos
7.
Radiography (Lond) ; 28(2): 420-425, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-34702665

RESUMO

INTRODUCTION: To compare the computed tomography (CT) number for paediatric cardiac computed tomography angiography (CCTA) and visualisation score of the three-dimensional (3D) images using the conventional T-shaped extended tube (T-tube) and spiral flow-generating extended tube (spiral-tube) connected between the contrast injector and cannula. METHODS: In total, 108 patients suspected to have congenital heart disease (CHD) were considered for inclusion. We utilised the T-tube for intravenous contrast and spiral-tube in 54 patients each. Observers individually inspected randomized volume rendering images of the internal thoracic artery, each acquired from the with or without spiral-tube groups, using a four-point scale. We compared the mean CT number of the ascending aorta (AAO) and pulmonary artery (PA), contrast noise ratio (CNR), CT number for the AAO and PA enhancement ratio, and the visualisation scores between the groups. RESULTS: There were no significant differences in patient characteristics between the with or without spiral-tube groups (p > 0.05). The mean CT number ±standard deviation for the AAO and PA, and the CNR without or with spiral-tube groups were 441.2 ± 89.2 and 489.8 ± 86.1 HU for the AAO, 436.3 ± 100.6 and 475.3 ± 85.2 HU for the PA, and 9.5 ± 2.2 and 10.8 ± 2.4 for the CNR, respectively (p < 0.05). In the spiral-tube group, the CT number, CNR, and visualisations score of the 3D images were significantly higher for the AAO and PA than those in the T-tube group (p < 0.05). CONCLUSION: The spiral-tube proved to be beneficial in improving the CT number for the AAO and PA, CNR, and visualisation score compared with the conventional T-tube during paediatric CCTA. IMPLICATIONS FOR PRACTICE: The spiral-tube may allow the visualisation of smaller blood vessels than those visualised by the conventional T-tube for paediatric patients in CCTA.


Assuntos
Angiografia por Tomografia Computadorizada , Tomografia Computadorizada por Raios X , Criança , Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Coração , Humanos , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos
8.
Radiography (Lond) ; 28(2): 412-419, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-34702666

RESUMO

INTRODUCTION: This study aimed to compare the correlation between the computed tomography (CT) enhancement rate of the venous to portal venous phase (VP-ER) and the extracellular volume (ECV) fraction with shear-wave ultrasound elastography (USE) findings in patients with liver fibrosis. METHODS: We included 450 patients with clinically suspected liver cirrhosis who underwent triphasic dynamic CT studies and USE. We compared the USE results with the unenhanced CT phase, with enhancement in the hepatic artery phase (HAP), portal venous phase (PVP), and venous phase (VP), and with the ECV fraction and the VP-ER. We also compared the area under the curve (AUC) of the receiver operating characteristic (ROC) curve of the ECV fraction and VP-ER with that of the values obtained with USE. RESULTS: The VP-ER was the most highly correlated with the liver stiffness value determined with USE (Pearson's correlation coefficient: r = 0.37), followed by enhancement in the PVP (r = -0.25), CT number on unenhanced CT scans (r = -0.22), the ECV fraction (r = 0.19), enhancement in the VP (r = 0.059), and enhancement in the HAP (r = -0.023) (all p < 0.01). The VP-ER showed a significantly higher AUC than the ECV fraction (0.75 vs 0.62) when the liver stiffness was >15 kPa in USE studies (p = 0.04). CONCLUSION: Compared to the ECV fraction, the VP-ER is more useful for predicting all degrees of liver fibrosis on routine triphasic dynamic CT images. IMPLICATIONS FOR PRACTICE: Although improvement is needed, the VP-ER has a higher diagnostic ability for liver fibrosis than the ECV fraction in clinical practice.


Assuntos
Técnicas de Imagem por Elasticidade , Técnicas de Imagem por Elasticidade/métodos , Humanos , Cirrose Hepática/diagnóstico por imagem , Veia Porta/diagnóstico por imagem , Curva ROC , Tomografia Computadorizada por Raios X
9.
Radiography (Lond) ; 27(3): 888-896, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-33820690

RESUMO

INTRODUCTION: With intra-arterial digital subtraction angiography (DSA) considered as the gold standard, we compared the diagnostic value of computed tomography angiography (CTA) and computed tomography-digital subtraction angiography (CT-DSA in hemodialysis (HD) patients suspected of having lower limb peripheral artery disease (PAD). METHODS: In this retrospective study, we enrolled 220 HD patients with suspected PAD. CT-DSA images were obtained by subtracting unenhanced images from enhanced images. The research team calculated the area under the curve (AUC), sensitivity, specificity, positive and negative predictive value (PPV, NPV), and recorded the diagnostic accuracy between the CTA and CT-DSA images using the DSA as gold standard. Visual evaluation of calcifications in the peripheral arteries were also compared between CTA and CT-DSA images. RESULTS: At the above-knee level, the CTA AUC [95% confidence interval (CI)] was 0.68 (CI 0.64-0.72), sensitivity and specificity were 60 and 81%, PPV and NPV were 85 and 53%, and accuracy was 67%. Below the knee, these values were 0.66 (CI 0.62-0.70), 71 and 79%, 79 and 47%, and 66%. For CT-DSA, above-knee, the AUC [95% CI] was 0.88 (CI 0.85-0.91), sensitivity and specificity were 84 and 92%, PPV and NPV were 89 and 97%, and accuracy was 93%. Below the knee, these values were 0.95 (CI 0.93-0.97), 95 and 93%, 96 and 83%, and 93%. The scores for the visualization of calcification in the peripheral arteries was significantly higher for CT-DSA than CTA (p < 0.05). CONCLUSIONS: CT-DSA helps to assess stenotic PAD with high calcification in the lower extremities of HD patients. IMPLICATIONS FOR PRACTICE: On CT-DSA images, the severity of vascular calcification can be assessed for HD patients suspected of PAD of the lower extremities.


Assuntos
Doença Arterial Periférica , Angiografia Digital , Humanos , Extremidade Inferior/diagnóstico por imagem , Doença Arterial Periférica/diagnóstico por imagem , Diálise Renal , Reprodutibilidade dos Testes , Estudos Retrospectivos , Tomografia Computadorizada por Raios X
10.
Radiography (Lond) ; 27(3): 920-926, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-33762147

RESUMO

INTRODUCTION: We compared the diagnostic performance of morphological methods such as the major axis, the minor axis, the volume and sphericity and of machine learning with texture analysis in the identification of lymph node metastasis in patients with thyroid cancer who had undergone contrast-enhanced CT studies. METHODS: We sampled 772 lymph nodes with histology defined tissue types (84 metastatic and 688 benign lymph nodes) that were visualised on CT images of 117 patients. A support vector machine (SVM), free programming software (Python), and the scikit-learn machine learning library were used to discriminate metastatic-from benign lymph nodes. We assessed 96 texture and 4 morphological features (major axis, minor axis, volume, sphericity) that were reported useful for the differentiation between metastatic and benign lymph nodes on CT images. The area under the curve (AUC) obtained by receiver operating characteristic analysis of univariate logistic regression and SVM classifiers were calculated for the training and testing datasets. RESULTS: The AUC for all classifiers in training and testing datasets was 0.96 and 0.86, at the SVM for machine learning. When we applied conventional methods to the training and testing datasets, the AUCs were 0.63 and 0.48 for the major axis, 0.70 and 0.44 for the minor axis, 0.66 and 0.43 for the volume, and 0.69 and 0.54 for sphericity, respectively. The SVM using texture features yielded significantly higher AUCs than univariate logistic regression models using morphological features (p = 0.001). CONCLUSION: For the identification of metastatic lymph nodes from thyroid cancer on contrast-enhanced CT images, machine learning combined with texture analysis was superior to conventional diagnostic methods with the morphological parameters. IMPLICATIONS FOR PRACTICE: Our findings suggest that in patients with thyroid cancer and suspected lymph node metastasis who undergo contrast-enhanced CT studies, machine learning using texture analysis is high diagnostic value for the identification of metastatic lymph nodes.


Assuntos
Neoplasias da Glândula Tireoide , Tomografia Computadorizada por Raios X , Humanos , Linfonodos/diagnóstico por imagem , Metástase Linfática/diagnóstico por imagem , Aprendizado de Máquina , Neoplasias da Glândula Tireoide/diagnóstico por imagem
11.
Radiography (Lond) ; 27(3): 840-846, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-33549491

RESUMO

INTRODUCTION: To compare the radiation dose, diagnostic accuracy, and the resultant ablation procedures using 80 and 120-kVp cardiac computed tomography angiography (CCTA) protocols with the same contrast-to-noise ratio in patients scheduled for atrial fibrillation (AF) ablation. METHODS: This retrospective study was performed following institutional review board approval. We divided 140 consecutive patients who had undergone CCTA using a 64-MDCT scanner into two equal groups. Standard deviation (SD) of the CT number was set at 25 Hounsfield units (HU) for the 120-kVp protocol. To facilitate a reduction in radiation dose it was set at 40 HU for the 80 kVp protocol. We compared the two protocols with respect to the radiation dose, the diagnostic accuracy for detecting left atrial appendage (LAA) thrombi, matching for surface registration, and the resultant ablation procedures. RESULTS: At 120 kVp, the dose length product (DLP) was 2.2 times that at 80 kVp (1269.0 vs 559.0 mGy cm, p < 0.01). The diagnostic accuracy for thrombus detection was 100% using both protocols. There was no difference between the two protocols with respect to matching for surface registration. The protocols did not differ with respect to the subsequent time required for the ablation procedures and the ablation fluoroscopy time, and the radiation dose (p = 0.54, 0.33, and 0.32, respectively). CONCLUSION: For the same CNR, the DLP at 80 kVp (559.0 mGy cm) was 56% of that delivered at 120 kVp (1269.0 mGy cm). There was no reduction in diagnostic accuracy. IMPLICATIONS FOR PRACTICE: Maintaining CNR allows for a reduction in the radiation dose without reducing the image quality.


Assuntos
Fibrilação Atrial , Exposição à Radiação , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Humanos , Doses de Radiação , Estudos Retrospectivos , Tomografia Computadorizada por Raios X
12.
Living Rev Relativ ; 21(1): 3, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29725242

RESUMO

We present possible observing scenarios for the Advanced LIGO, Advanced Virgo and KAGRA gravitational-wave detectors over the next decade, with the intention of providing information to the astronomy community to facilitate planning for multi-messenger astronomy with gravitational waves. We estimate the sensitivity of the network to transient gravitational-wave signals, and study the capability of the network to determine the sky location of the source. We report our findings for gravitational-wave transients, with particular focus on gravitational-wave signals from the inspiral of binary neutron star systems, which are the most promising targets for multi-messenger astronomy. The ability to localize the sources of the detected signals depends on the geographical distribution of the detectors and their relative sensitivity, and [Formula: see text] credible regions can be as large as thousands of square degrees when only two sensitive detectors are operational. Determining the sky position of a significant fraction of detected signals to areas of 5-[Formula: see text] requires at least three detectors of sensitivity within a factor of [Formula: see text] of each other and with a broad frequency bandwidth. When all detectors, including KAGRA and the third LIGO detector in India, reach design sensitivity, a significant fraction of gravitational-wave signals will be localized to a few square degrees by gravitational-wave observations alone.

13.
Obes Sci Pract ; 3(2): 219-223, 2017 06.
Artigo em Inglês | MEDLINE | ID: mdl-28702215

RESUMO

OBJECTIVE: This study examined the association between sudden natural death and abdominal fat using postmortem computed tomography (CT) scans. SUBJECTS AND METHODS: Postmortem CT images at the umbilical level of 241 subjects were used to measure abdominal areas of subcutaneous- and visceral fat, the rate of visceral fat and the waist circumference. Of the study subjects, 174 died of sudden natural death (130 men and 44 women), and 67 died of different causes (46 men and 21 women). All were between 40 and 75 years of age. Logistic regression analysis was performed to identify independent abdominal parameters associated with sudden natural death. RESULTS: By univariate analysis, the areas of subcutaneous and visceral fat were significantly larger in sudden natural death than who died of different causes (subcutaneous fat, odds ratio [OR] = 1.004, 95% confidence interval [CI] = 1.000-1.007, p = 0.03; visceral fat, OR = 1.008, 95% CI = 1.003-1.013, p < 0.01). Multivariate analysis showed that the area of visceral fat was an independent factor associated with the risk of sudden natural death (OR = 1.008, 95% CI = 1.002-1.015, p = 0.02). CONCLUSIONS: Postmortem CT revealed that sudden natural death was related to abdominal fat deposits.

14.
AJNR Am J Neuroradiol ; 37(11): 2123-2128, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27365323

RESUMO

BACKGROUND AND PURPOSE: The quantitative evaluation of orbital fat proliferation and edema and the assessment of extraocular muscles are useful for diagnosing and monitoring thyroid-associated orbitopathy. To evaluate therapy-induced quantitative changes in the orbital fat of patients with thyroid-associated orbitopathy, we performed volumetric and water fraction measurements by using T2-weighted FSE iterative decomposition of water and fat with echo asymmetry and least-squares estimation (FSE-IDEAL) imaging. MATERIALS AND METHODS: Orbital FSE-IDEAL images of 30 volunteers were acquired twice within 1 week. Nine patients with thyroid-associated orbitopathy underwent FSE-IDEAL imaging before and after methylprednisolone pulse therapy, and the treatment results were assessed by using their pre- and post-methylprednisolone pulse therapy clinical activity scores. We performed volumetric and water fraction measurements of orbital fat by using FSE-IDEAL imaging and evaluated interscan differences in the volunteers. In patients with thyroid-associated orbitopathy, we compared pre- and posttherapy orbital fat measurements and assessed the correlation between the pretherapy values and clinical activity score improvement. RESULTS: The reproducibility of results obtained by the quantitative evaluation of orbital fat in volunteers was acceptable. After methylprednisolone pulse therapy, the water fraction in the orbital fat of patients with thyroid-associated orbitopathy was significantly decreased (P < .001). There was a significant positive correlation between the pretherapy water fraction and clinical activity score improvement (right, r = 0.82; left, r = 0.79) and a significant negative correlation between the pretherapy volume and clinical activity score improvement (bilateral, r = -0.84). CONCLUSIONS: Volumetric and water fraction measurements of orbital fat by using FSE-IDEAL imaging are feasible and useful for monitoring the effects of therapy and for predicting the response of patients with thyroid-associated orbitopathy to methylprednisolone pulse therapy.

15.
AJNR Am J Neuroradiol ; 36(8): 1507-11, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25929881

RESUMO

BACKGROUND AND PURPOSE: Inflammation and degeneration of the intracranial saccular aneurysm wall play a major role in aneurysm formation, development and subsequent rupture. The aim of this study was to characterize the walls of unruptured intracranial aneurysms by using a hybrid of opposite-contrast MRA at 3T. MATERIALS AND METHODS: Fourteen consecutive patients with 17 unruptured intracranial aneurysms who initially underwent clipping surgery were prospectively evaluated. All aneurysms were scanned preoperatively by using a hybrid of opposite-contrast MRA in 3T high-resolution MR imaging. We classified intraoperative findings of atherosclerotic plaques in the aneurysms into 3 grades: grade A (major plaques), grade B (minor plaques), and grade C (no plaques). The contrast ratio of the high-intensity area was also measured relative to the background low-intensity area inside the carotid artery. RESULTS: Findings from preoperative plaque imaging of the aneurysm corresponded to the intraoperative findings in 15 of 16 aneurysms (excluding 1 that was impossible to visualize in its entirety due to anatomic reasons). Overall sensitivity and specificity of the hybrid of opposite-contrast MRA were 88.9% and 100%, respectively. During the operation, 4 aneurysms were classified as grade A; 5, as grade B; and 7, as grade C. The means of the contrast ratio for grades A, B, and C were 0.72 ± 0.03, 0.34 ± 0.30, and -0.02 ± 0.09, respectively. CONCLUSIONS: The hybrid of opposite-contrast MRA can detect visible atherosclerotic plaques in the unruptured aneurysm wall, and the contrast ratio in intracranial aneurysms correlated with their presence and extent. A study including a larger series is needed to validate the diagnostic potential of this imaging technique.


Assuntos
Angiografia Cerebral/métodos , Aneurisma Intracraniano/diagnóstico por imagem , Angiografia por Ressonância Magnética/métodos , Adulto , Idoso , Artéria Carótida Primitiva/diagnóstico por imagem , Feminino , Humanos , Imageamento Tridimensional/métodos , Masculino , Pessoa de Meia-Idade , Placa Aterosclerótica/diagnóstico por imagem
17.
Clin Radiol ; 69(8): 804-11, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24907185

RESUMO

AIM: To evaluate the radiation dose, image quality, and influence on visual contrast of low tube voltage abdominal computed tomography (CT) and the effects of display setting optimization. MATERIALS AND METHODS: One hundred and fifty-seven patients were randomly assigned to one of three protocols. Fifty-two patients underwent a 120 kVp protocol, and 53 and 52 patients underwent low-dose protocols with 100 and 80 kVp, respectively. The effective dose (ED), image noise, CT attenuation, and signal-to-noise ratio (SNR) of each organ of each protocol were compared using Dunnett's test. Qualitative analysis between the protocols was also performed. RESULTS: The ED of the 100 and 80 kVp protocols were 22% and 37% reduced, respectively. There were no significant differences in the SNR between the protocols (120 kVp: 13.8 ± 3.5; 100 kVp: 13.9 ± 3.3; 80 kVp: 13.5 ± 2.9; p > 0.05). However, there were significant differences in contrast familiarity between the 120 kVp images and all the other images, except 100 kVp images, with optimized display settings (p < 0.05). CONCLUSION: In abdominal CT, an 80 kVp setting offers greater radiation dose reduction than a 100 kVp setting without significant deterioration of the SNR; however, the visual contrast between the organs might be changed.


Assuntos
Meios de Contraste , Doses de Radiação , Intensificação de Imagem Radiográfica/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Radiografia Abdominal/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso , Análise de Variância , Feminino , Humanos , Iohexol , Iopamidol/análogos & derivados , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Razão Sinal-Ruído
18.
AJNR Am J Neuroradiol ; 35(1): 100-5, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23886740

RESUMO

BACKGROUND AND PURPOSE: Antiphospholipid syndrome may affect the incidence and pathogenesis of cerebrovascular diseases in patients with systemic lupus erythematosus. We compared the spectrum of MR findings in patients with systemic lupus erythematosus with and without antiphospholipid syndrome. MATERIALS AND METHODS: We identified 256 patients with systemic lupus erythematosus (45 with, 211 without antiphospholipid syndrome) who underwent MR studies; in 145 (57%), we detected abnormalities. These were categorized as large territorial, lacunar, localized cortical, and borderzone infarctions and as microembolisms, basal ganglia lesions, callosal lesions, hemorrhages, and white matter hyperintensity on T2-weighted and/or FLAIR images, and as stenotic arterial lesions on MR angiograms. Logistic regression analysis was performed to compare the MR findings in patients with systemic lupus erythematosus with and without antiphospholipid syndrome, with patient age and antiphospholipid syndrome as the covariates. RESULTS: Abnormal MR findings were more common in patients with systemic lupus erythematosus with antiphospholipid syndrome (73% versus 53%). Large territorial (P = .01), lacunar (P = .01), localized cortical (P < .01), borderzone infarcts (P < .01), basal ganglia lesions (P = .03), stenotic arterial lesions (P = .04), and the rate of positive findings on MR imaging (P = .01) were significantly associated with antiphospholipid syndrome. Irrespective of age, significantly more patients with antiphospholipid syndrome manifested lacunar infarcts in the deep white matter (P < .01), localized cortical infarcts in the territory of the MCA (P < .01), bilateral borderzone infarcts (P < .01), and anterior basal ganglia lesions (P = .01). CONCLUSIONS: Abnormal MR findings were more common in patients with systemic lupus erythematosus with than in those without antiphospholipid syndrome. Large territorial infarctions, lacunar infarctions in the deep white matter, localized cortical infarctions in the MCA territory, bilateral borderzone infarctions, anterior basal ganglia lesions, and stenotic arterial lesions are common MR findings in patients with systemic lupus erythematosus with antiphospholipid syndrome.


Assuntos
Síndrome Antifosfolipídica/complicações , Síndrome Antifosfolipídica/patologia , Encéfalo/patologia , Vasculite Associada ao Lúpus do Sistema Nervoso Central/complicações , Vasculite Associada ao Lúpus do Sistema Nervoso Central/patologia , Imageamento por Ressonância Magnética/métodos , Fibras Nervosas Mielinizadas/patologia , Adulto , Feminino , Humanos , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
19.
AJNR Am J Neuroradiol ; 34(4): 870-6, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23042931

RESUMO

BACKGROUND AND PURPOSE: Volumetry may be useful for evaluating treatment response and prognosis of intraocular lesions. Phantom, volunteer, and patient studies were performed to determine whether ocular MR volumetry is reproducible. MATERIALS AND METHODS: Half-Fourier single-shot RARE and FSPGR sequences at 1.5T with a 76-mm-diameter surface coil were optimized to obtain still ocular images. Volumetry accuracies of each sequence were compared with simulated subretinal phantom volumes. Ocular volumetry was performed in 15 volunteers twice in 1 week by using contiguous axial images of the globes while the subjects stared at a target, and images were acquired in 2 seconds before the subjects were instructed to blink, with this process repeated as necessary. Imaging, intraobserver, and interobserver reproducibility for volumes of the whole eyeball and anterior chamber were assessed. Ocular volumetry was also performed in 6 patients with intraocular tumors before and after treatment. RESULTS: The phantom study demonstrated that measurement error rates with RARE were significantly lower than with FSPGR (P<.01). The volunteer study demonstrated excellent imaging and intraobserver reproducibility of RARE volumetry for whole eyeballs and anterior chambers (P<.01). Although no interobserver differences were observed in anterior chamber volume measurement (P=.33), there was a significant difference between the 2 observers in eyeball volume measurement (P<.01). Follow-up volumetric data were useful for treatment decisions in all patients. CONCLUSIONS: Ocular volumetry from contiguous ultrafast RARE images obtained during visual fixation is feasible in volunteer and patient studies and is superior to FSPGR images.


Assuntos
Oftalmopatias/patologia , Olho/patologia , Imageamento por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética/normas , Imagens de Fantasmas , Adulto , Artefatos , Neoplasias da Coroide/patologia , Olho/anatomia & histologia , Traumatismos Oculares/patologia , Neoplasias Oculares/patologia , Estudos de Viabilidade , Feminino , Hemangioma/patologia , Humanos , Imageamento por Ressonância Magnética/instrumentação , Masculino , Melanoma/patologia , Variações Dependentes do Observador , Tamanho do Órgão , Reprodutibilidade dos Testes , Descolamento Retiniano/patologia , Retinoblastoma/patologia
20.
Clin Radiol ; 65(8): 609-15, 2010 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-20599062

RESUMO

AIM: To investigate the effect of a double-exposure dual-energy subtraction (DES) technique on the diagnostic performance of radiologists detecting small pulmonary nodules on flat-panel detector (FPD) chest radiographs. MATERIALS AND METHODS: Using FPD radiography 41 sets of chest radiographs were obtained from 26 patients with pulmonary nodules measuring

Assuntos
Competência Clínica/normas , Neoplasias Pulmonares/diagnóstico por imagem , Radioterapia (Especialidade)/normas , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Nódulo Pulmonar Solitário/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Curva ROC , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/instrumentação , Sensibilidade e Especificidade , Técnica de Subtração/instrumentação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...