Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 21
Filtrar
1.
Burns ; 50(4): 966-979, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38331663

RESUMO

AIM: This study was conducted to determine the segmentation, classification, object detection, and accuracy of skin burn images using artificial intelligence and a mobile application. With this study, individuals were able to determine the degree of burns and see how to intervene through the mobile application. METHODS: This research was conducted between 26.10.2021-01.09.2023. In this study, the dataset was handled in two stages. In the first stage, the open-access dataset was taken from https://universe.roboflow.com/, and the burn images dataset was created. In the second stage, in order to determine the accuracy of the developed system and artificial intelligence model, the patients admitted to the hospital were identified with our own design Burn Wound Detection Android application. RESULTS: In our study, YOLO V7 architecture was used for segmentation, classification, and object detection. There are 21018 data in this study, and 80% of them are used as training data, and 20% of them are used as test data. The YOLO V7 model achieved a success rate of 75.12% on the test data. The Burn Wound Detection Android mobile application that we developed in the study was used to accurately detect images of individuals. CONCLUSION: In this study, skin burn images were segmented, classified, object detected, and a mobile application was developed using artificial intelligence. First aid is crucial in burn cases, and it is an important development for public health that people living in the periphery can quickly determine the degree of burn through the mobile application and provide first aid according to the instructions of the mobile application.


Assuntos
Inteligência Artificial , Queimaduras , Aplicativos Móveis , Queimaduras/classificação , Queimaduras/diagnóstico por imagem , Queimaduras/patologia , Humanos , Fotografação/métodos
2.
Arch Psychiatr Nurs ; 46: 40-50, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37813502

RESUMO

PURPOSE: In this study, the effects of intercultural sensitivity and ethnocentrism on health tourism awareness levels in nurses were examined. DESIGN AND METHODS: This quantitative cross-sectional study was conducted in Turkey between November 2022 and March 2023. Intercultural sensitivity scale, ethnocentrism scale, and health tourism awareness scale were used to collect the data. R programming language 4.1.3, G*Power 3.1 and SPSS-22 program were used in the analysis of the study. RESULTS: This study was conducted with 386 nurses. Intercultural sensitivity has a positive and significant effect on health tourism awareness levels (ß = 0.141; t(384) = 2.784, p = 0.006). Ethnocentrism has a positive and significant effect on health tourism awareness levels (ß = 0.184; t(384) = 3.659, p = 0.001). Random Forest regression was found to be the best performing algorithm among the machine learning algorithms for predicting the Health Tourism Awareness variable. Looking at the contributions of the variables to the model, according to the SHAP value (Shapley Additive Explanations), it was seen that the most important variable that should be in the model to predict the health tourism awareness variable is the ethnocentrism variable. CONCLUSION: It was determined that as the level of intercultural sensitivity and ethnocentrism of nurses increased, their awareness of health tourism increased. Longitudinal studies on health tourism awareness in nurses are recommended.


Assuntos
Turismo Médico , Humanos , Estudos Transversais , Comunicação , Turquia
3.
J Transcult Nurs ; 34(3): 238-246, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36927307

RESUMO

INTRODUCTION: Intercultural sensitivity and xenophobia levels of health education students can affect the care they give to the patient. It is important to know the level of intercultural sensitivity and xenophobia of students receiving health education and to determine the relationship between them. The purpose of the study was to examine the relationship between xenophobic attitudes and intercultural sensitivity among university students. METHODS: This quantitative cross-sectional research was conducted in between January and June 2022 with health education students. The study conducted with health education students at Gumushane University and Agri Ibrahim Cecen University. Child Development, Nursing, Emergency Management Services/Technicians, Nutrition and Dietetics, Elderly care, Social services, Medical Laboratory Techniques, and Disabled Care studying at these universities were included in the study. Students who received health education and wanted to participate voluntarily in the study were included. Students aged 18 and over, studying in the health education department of the university, studying in the 1, 2, 3, 4th classes and volunteering to participate in the study were included in the study. The Introductory Information Form, the Xenophobia Scale, and the Intercultural Sensitivity Scale were used to collect the research data. RESULTS: This study was conducted with 789 students. According to our study, a significant negative correlation was found between the students' xenophobia scale and the intercultural sensitivity scale total score means (p < .05). Intercultural sensitivity has a negative and significant effect on the level of xenophobia (ß = -0.116; t (787) = -3.283, p = .001). A significant difference was found between the students' Xenophobia Scale total score mean and gender, department, and grade (p < .05) as was the case between Intercultural Sensitivity Scale total score mean and gender, department, grade, immigrant acquaintance, and foreign language knowledge (English language) level (p < .05). DISCUSSION: Intercultural sensitivity has a negative and significant effect on the level of xenophobia. It can negatively affect the level of caregiving of students receiving health education. It is thought that intercultural sensitivity will be developed by including course content in the curriculum to increase students' intercultural effectiveness and awareness levels and to reduce xenophobic prejudices.


Assuntos
Estudantes de Enfermagem , Xenofobia , Criança , Humanos , Adolescente , Adulto , Estudos Transversais , Estudantes , Educação em Saúde , Atitude
4.
Medicina (Kaunas) ; 57(8)2021 Jul 30.
Artigo em Inglês | MEDLINE | ID: mdl-34440982

RESUMO

Background and Objectives: Atrial fibrillation (AF) is the most common arrythmia of the human heart. Patients mostly present highly symptomatic with dyspnea and tachycardia and have a disproportionate risk of developing heart failure or stroke events. We aimed to evaluate the determinants of early conversion into sinus rhythm during initial stay at the emergency department of a large tertiary care center. Materials and Methods: A total of 1384 subjects with recent-onset AF were recruited between October 2014 and April 2017. Patients with longstanding AF were excluded, resulting in a total of 935 patients for the present analysis. Results: In multivariate adjusted logistic regression analyses, previous catheter ablation therapy was a strong predictor of conversion in sinus rhythm during the stay in the emergency department, with an odds ratio (OR) of 3.87 (95% CI 2.40, 6.54; p < 0.001). In contrast, existing antiarrhythmic medication showed no association with facilitated conversion [OR 0.89 (95%CI 0.65, 1.20); p = 0.44]. Likewise, conventional cardiovascular risk factors (hypertension, dyslipidemia, diabetes) were also not associated with conversion during hospital stay. Conclusion: This is the first report on the relevance of previous ablation therapy for early restoration of sinus rhythm in recent-onset AF. Although catheter ablation is associated with relevant risk of late recurrence of atrial fibrillation, it seems to have a large benefit for patients with recent-onset AF.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/cirurgia , Hospitais , Humanos , Recidiva , Estudos Retrospectivos , Resultado do Tratamento
5.
ESC Heart Fail ; 8(4): 2485-2491, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-33934533

RESUMO

AIMS: The increased incidence of heart failure in men suggests that endogenous sex hormones might play a role in the development of heart failure, but epidemiological data remain sparse. Here, we evaluated the predictive value of low testosterone levels on future heart failure in the large population-based FINRISK97 study. METHODS AND RESULTS: Baseline serum testosterone concentrations were measured in 7855 subjects (3865 men and 3990 women) of the FINRISK97 study. During a median follow-up (FU) of 13.8 years, a total of 564 heart failure events were recorded. The age-adjusted baseline testosterone levels did not differ significantly between subjects developing incident heart failure during FU and those without incident events during FU (men: 16.6 vs. 17.1 nmol/L, P = 0.75; women: 1.15 vs. 1.17 nmol/L, P = 0.32). Relevant statistically significant correlations of testosterone levels were found with high-density lipoprotein cholesterol levels (R = 0.22; P < 0.001), body mass index (R = -0.23; P < 0.001), and waist-to-hip ratio (R = -0.21; P < 0.001) in men, while statistically significant correlations in women were negligible in effect size. In sex-stratified Cox regression analyses, taking age into account, a quite strong association between low testosterone and incident heart failure was found in men [hazard ratio (HR) 1.51 (95% confidence interval, CI: 1.09-2.10); P = 0.020 for lowest vs. highest quarter], but not in women [HR 0.70 (95% CI: 0.49-0.98); P = 0.086 for lowest vs. highest quarter]. Nevertheless, this association turned non-significant after full adjustment including body mass index and waist-to-hip ratio, and testosterone levels were no longer predictive for incident heart failure-neither in men [HR 0.99 (95% CI: 0.70-1.42); P = 0.77 for lowest vs. highest quarter] nor in women [HR 0.92 (95% CI: 0.64-1.33); P = 0.99 for lowest vs. highest quarter]. Accordingly, Kaplan-Meier analyses did not reveal significant association of testosterone levels with heart failure. CONCLUSIONS: Low levels of testosterone do not independently predict future heart failure.


Assuntos
Insuficiência Cardíaca , Índice de Massa Corporal , Feminino , Previsões , Insuficiência Cardíaca/epidemiologia , Humanos , Incidência , Masculino , Testosterona
6.
J Electrocardiol ; 60: 102-106, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32339814

RESUMO

AIMS: Implantable loop recorders (ILR) are recommended to detect atrial fibrillation (AF) in cases of cryptogenic stroke. However, real life data besides controlled trials are rare. Aim of the study was the detection of atrial fibrillation with a special focus on other arrhythmias according to criteria defined in earlier clinical trials. METHODS: We performed a retrospective analysis of 64 patients with cryptogenic stroke who underwent ILR implantation between 4/2014 and 1/2018. The primary endpoint was the detection of atrial fibrillation, significant bradycardia (<40 bpm) or tachycardia (>150 bpm). ILR interrogation was performed after implantation and 6, 12 and 24 months thereafter. RESULTS: Mean patients age was 65.4 ± 12 years, 50% were male. Mean follow-up duration was 419.2 ± 309 days. One death occurred during follow-up. 23 patients (35.9%) experienced a symptomatic clinical neurological or cardiac event during follow-up. Overall rate of detected arrhythmias was 35% (23/64). The most frequent arrhythmia was atrial fibrillation which was observed in 16 patients (25%). 6 of 16 patients presenting with atrial fibrillation had no clinical symptoms. Bradycardias requiring subsequent pacemaker implantations were detected in 9.4%. A ventricular tachycardia was observed in one patient (1.6%). CONCLUSION: In this group of patients with cryptogenic stroke the rate of arrhythmic events was high. Besides a high rate of atrial fibrillation (25%), an unexpectedly high rate of bradyarrhythmias (9.4%) occurred in our patient collective. Since many of those episodes were clinically asymptomatic, the ILR helps to detect and treat those clinically silent arrhythmias.


Assuntos
Fibrilação Atrial , AVC Isquêmico , Acidente Vascular Cerebral , Idoso , Fibrilação Atrial/diagnóstico , Eletrocardiografia , Eletrocardiografia Ambulatorial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Acidente Vascular Cerebral/diagnóstico
7.
Heart Vessels ; 33(4): 441-446, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29030709

RESUMO

Recent studies have shown that subcutaneous or subfascial pacemaker- and ICD implantation with continued oral anticoagulation therapy is associated with lower risk for bleeding complications, when compared to heparin bridging strategies. However, ICD generators are often implanted submuscularly. We therefore compared the bleeding risk with continued phenprocoumon therapy vs. heparin bridging in patients receiving submuscular ICD implantation. Between 01/2013 and 12/2013, 104 patients with need for oral anticoagulation received submuscular ICD or CRT-D implantation in our institution. 46 patients were implanted under continued phenprocoumon therapy while 58 patients received heparin bridging for implantation procedure. All ICD generators were placed submuscularly. The primary outcome of the study was clinically significant bleeding or device pocket hematoma with need for surgical revision. Mean patients age was 63.7 years, 72.1% were male. In patients with heparin bridging therapy, preoperative INR prior to ICD implantation was 1.2 ± 0.31 while in the group of patients on continued phenprocoumon therapy, mean pre-OP INR was 2.4 ± 0.47. In heparin bridging group, 8 (13.8%) patients experienced a clinically relevant pocket hematoma, while only 1 (2.2%) patient on continued phenprocoumon therapy needed surgical revision for pocket hematoma (P = 0.04). No further bleeding complications or clinically relevant pericardial effusion was observed in any of the groups and no perioperative thromboembolic event occurred. Submuscular ICD implantation under continued phenprocoumon therapy was safe and feasible. Compared to patients with heparin bridging therapy, those with continued phenprocoumon therapy had a lower incidence of clinically relevant bleeding complications.


Assuntos
Anticoagulantes/efeitos adversos , Arritmias Cardíacas/terapia , Desfibriladores Implantáveis/efeitos adversos , Heparina/efeitos adversos , Hemorragia Pós-Operatória/induzido quimicamente , Tromboembolia/prevenção & controle , Idoso , Anticoagulantes/administração & dosagem , Arritmias Cardíacas/mortalidade , Vias de Administração de Medicamentos , Fáscia , Feminino , Alemanha/epidemiologia , Heparina/administração & dosagem , Humanos , Masculino , Hemorragia Pós-Operatória/epidemiologia , Prevalência , Estudos Retrospectivos , Medição de Risco , Taxa de Sobrevida/tendências
8.
Interact Cardiovasc Thorac Surg ; 24(1): 77-81, 2017 01.
Artigo em Inglês | MEDLINE | ID: mdl-27624353

RESUMO

OBJECTIVES: Lead extraction in patients with multiple or old leads of an implantable cardioverter defibrillator (ICD) is challenging. As adhesions are common at the side of the shock coils, we investigated success and procedural complication rates of laser lead extraction procedures in single- and dual-coil leads. METHODS: Between January 2001 and June 2013, 41 single- and 145 dual-coil ICD leads were extracted from 171 patients using laser sheaths. Procedural data, success rates and complications were collected into a database and retrospectively analysed. RESULTS: The mean patient age was 58.2 ± 16.1 years. The mean time from initial lead implantation to extraction was 50.3 ± 18.4 and 45.8 ± 14.5 months in the single- and dual-coil group, respectively (P = 0.1). In the single-coil group, complete procedural success was achieved in 36 of 37 (97.3%) cases, and clinical success in all cases (100.0%). In the dual-coil group, complete procedural success was seen in 131 out of 134 (97.8%) patients, and clinical success in 132 of 134 cases (98.5%). The transvenous extraction failed in 2 cases (1.5%). The overall complication rate was 2.7% in the single-coil group and 3.7% in the dual-coil group, respectively (P = 1.0). No deaths occurred during the 30-day follow-up. The mean laser treatment time was 1.8 ± 1.5 min for the single-coil group and 2.5 ± 1.2 min for dual-coil group (P = 0.002). CONCLUSIONS: Laser lead extraction allows for safe and effective removal of ICD leads. Compared with single-coil leads, the extraction of dual-coil leads is associated with longer laser treatment times but without statistically significant differences in complications and procedural success rates.


Assuntos
Desfibriladores Implantáveis , Remoção de Dispositivo/métodos , Terapia a Laser , Lasers de Excimer/uso terapêutico , Adolescente , Adulto , Idoso , Arritmias Cardíacas/terapia , Falha de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Aderências Teciduais , Adulto Jovem
9.
Heart Vessels ; 31(8): 1347-53, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26319443

RESUMO

Different follow-up methods have been used to report success rates after AF ablation. Recent studies have shown that intermittent rhythm monitoring underestimates the actual AF recurrence rate. We therefore report our experience with continuous rhythm monitoring by implantable loop recorder (ILR) in a large patient cohort. Between 09/2008 and 12/2012, 343 cardiac surgical patients underwent concomitant surgical AF ablation. ILR implantation was performed in 206 patients. ILR interrogation was accomplished at 3, 6 and 12 months postoperatively. Successful ablation was defined as AF Burden <0.5 %. Primary outcome of the study was freedom from AF at 12-month follow-up. Mean patient's age was 70.5 ± 7.4 years. No major ablation- or ILR-related complications occurred. In 4 patients (1.9 %) ILR had to be explanted due to ILR-related wound infection (n = 2) or chronic pain (n = 2). Survival rate at 1-year follow-up was 96.6 %. Freedom from AF rate after 1-year follow-up was 68.5 and 63.6 % off antiarrhythmic drugs, respectively. Statistically significant predictors for successful ablation at 1-year follow-up were smaller LA diameter, shorter duration of AF and preoperative paroxysmal AF. Demographic data, indication for surgery, lesion set and used energy source had no impact on freedom from AF after 1 year. Continuous ILR monitoring after concomitant surgical AF ablation was safe and feasible, with registered freedom from AF rate of 68.5 % at 1-year follow-up. Thus continuous rhythm monitoring provides reliable outcome data and helps to guide antiarrhythmic therapy.


Assuntos
Fibrilação Atrial/cirurgia , Procedimentos Cirúrgicos Cardíacos , Ablação por Cateter , Eletrocardiografia Ambulatorial/métodos , Idoso , Feminino , Seguimentos , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Recidiva , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento
10.
J Thorac Cardiovasc Surg ; 148(5): 2161-6, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24667024

RESUMO

OBJECTIVES: Various lesion sets and subsequent success rates have been reported in patients receiving concomitant surgical ablation for atrial fibrillation. However, most of these results have been obtained by discontinuous monitoring. We report results using continuous event recorder rhythm monitoring to compare more accurately the efficacy of a left versus biatrial lesion set to treat patients with persistent atrial fibrillation. METHODS: Between July 2008 and December 2011, 66 patients with persistent or long-standing persistent atrial fibrillation underwent concomitant surgical atrial fibrillation ablation with a biatrial lesion set and subcutaneous event recorder implantation. The results and outcomes were compared with a propensity score-matched cohort of 66 patients with a left atrial lesion set and event recorder implantation. Event recorder interrogation was performed at 3, 6, and 12 months follow-up. RESULTS: The mean patient age was 70.2±7.4 years, and 70.3% were male. No major ablation-related complications occurred. One-year survival was 94.8% with no statistically significant differences between the 2 groups. The overall rate of freedom from atrial fibrillation was 57.3% and 64.4% after 3 and 12 months follow-up, respectively. Three months postoperatively, patients in the biatrial group had a slightly higher rate of freedom from atrial fibrillation (63.6% vs 52.3% P=.22), but it did not reach statistical significance. At 12 months follow-up, a statistically significant higher rate of freedom from atrial fibrillation was observed in patients with a biatrial lesion set (74.4% vs 55.8%; P=.026). The mean atrial fibrillation burden in all patients was 15.1%±12.5% in the biatrial group and 21.2%±14.4% in the left atrial group 12 months postoperatively (P=.03). CONCLUSIONS: Continuous rhythm monitoring by subcutaneous event recorder implantation was safe and feasible. In patients undergoing biatrial ablation, a statistically significant higher rate of freedom from atrial fibrillation was observed at 12 months follow-up.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter , Eletrocardiografia , Telemetria , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/mortalidade , Fibrilação Atrial/fisiopatologia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/mortalidade , Eletrocardiografia/instrumentação , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Pontuação de Propensão , Recidiva , Estudos Retrospectivos , Fatores de Risco , Telemetria/instrumentação , Fatores de Tempo , Resultado do Tratamento
11.
Interact Cardiovasc Thorac Surg ; 18(1): 56-60, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24087832

RESUMO

OBJECTIVES: Laser lead extraction is a challenging procedure, especially in patients with old or multiple pacemaker (PM) or implantable cardioverter defibrillator (ICD) leads. The mechanical force is a leading cause of complications during the extraction procedure. Use of new laser sheaths, which deliver a rate of 80 pulses per second, may probably reduce intraoperative adverse events by reduction of extraction force. METHODS: Between January 2012 and April 2013, 76 PM and ICD leads were treated in 38 patients using GlideLight 80 Hz laser sheaths. Indications for lead removals were pocket infection (42.1%), septicaemia or endocarditis (23.7%), lead dysfunction (31.6%) and upgrade from PM to ICD (2.6%). Data on procedural success rates, intra- and postoperative outcomes, as well as 30-day mortality were collected into a database and analysed retrospectively. RESULTS: The mean patient age was 62.0 ± 17.7 years (range 18-83), and 73.7% were male. The mean time from initial lead implantation was 96.0 ± 58.3 months (range 24-288). Thirty-seven (48.7%) PM and 39 (51.3%) ICD leads had to be extracted. The mean procedural time was 68.3 ± 27.3 min (range 35-115). Seventy-two of 76 leads (94.8%) were completely removed, partial removal was achieved in 2 (2.6%) leads and a failure of extraction occurred in 2 (2.6%) leads. The overall complication rate was 5.2%, including one major (superior vena cava perforation) (2.6%) and one minor (pocket haematoma) (2.6%) complication. No death occurred during the 30-day follow-up. CONCLUSIONS: The GlideLight 80 Hz laser sheath allows safe and effective removal of chronically implanted PM and ICD leads, combining high procedural success with low complication rates.


Assuntos
Catéteres , Desfibriladores Implantáveis , Remoção de Dispositivo/instrumentação , Terapia a Laser/instrumentação , Lasers de Excimer , Marca-Passo Artificial , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Remoção de Dispositivo/efeitos adversos , Remoção de Dispositivo/mortalidade , Humanos , Terapia a Laser/efeitos adversos , Terapia a Laser/mortalidade , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/etiologia , Desenho de Prótese , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem
12.
World J Cardiol ; 2(10): 308-15, 2010 Oct 26.
Artigo em Inglês | MEDLINE | ID: mdl-21160608

RESUMO

Vasovagal syncope is a common cause of recurrent syncope. Clinically, these episodes may present as an isolated event with an identifiable trigger, or manifest as a cluster of recurrent episodes warranting intensive evaluation. The mechanism of vasovagal syncope is incompletely understood. Diagnostic tools such as implantable loop recorders may facilitate the identification of patients with arrhythmia mimicking benign vasovagal syncope. This review focuses on the management of vasovagal syncope and discusses the non-pharmacological and pharmacological treatment options, especially the use of midodrine and selective serotonin reuptake inhibitors. The role of cardiac pacing may be meaningful for a subgroup of patients who manifest severe bradycardia or asystole but this still remains controversial.

13.
Circ Arrhythm Electrophysiol ; 3(4): 351-60, 2010 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-20511536

RESUMO

BACKGROUND: Termination of persistent atrial fibrillation (AF) can be achieved through ablation, with the majority of patients terminating to an atrial tachycardia (AT) and fewer directly to sinus rhythm (SR). We aimed to identify potential predictors for the existence of a substrate for AT on termination to SR. METHODS AND RESULTS: We assessed 95 persistent AF patients (age, 60+/-10 years) who underwent catheter ablation to the end point of AF termination. Forty patients terminated directly to SR (SRterm) and 55 to ATs (ATterm). Compared with the ATterm group, the SRterm group were younger (56+/-10 versus 63+/-9 years, P=0.001), had shorter durations of AF before ablation (9+/-26 versus 14+/-20 months, P<0.001), smaller left atrial diameters (41+/-5 versus 45+/-5 mm, P=0.015), and longer baseline AF cycle lengths (178+/-23 versus 159+/-31 ms, P=0.005). However, AF cycle length was the sole independent predictor of direct termination to SR. The most frequent AF termination site in SRterm patients was the pulmonary veins (53%), whereas in ATterm patients this was within the left atrium (58%). After follow-up of 12+/-6 months, there was a trend toward a greater proportion of patients in SR among those who terminated directly to SR after a single procedure. The most frequent type of recurrence was paroxysmal AF in SRterm patients and AT in ATterm patients. CONCLUSIONS: Patients who terminate to SR through ablation without an intermediate AT are characterized by a less altered arrhythmogenic substrate. Baseline AF cycle lengths emerged as a sole independent predictor of a substrate for consecutive arrhythmias.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter , Taquicardia Supraventricular/etiologia , Idoso , Fibrilação Atrial/complicações , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/fisiopatologia , Ablação por Cateter/efeitos adversos , Distribuição de Qui-Quadrado , Eletrocardiografia , Técnicas Eletrofisiológicas Cardíacas , Humanos , Modelos Logísticos , Pessoa de Meia-Idade , Recidiva , Reoperação , Medição de Risco , Fatores de Risco , Taquicardia Supraventricular/epidemiologia , Taquicardia Supraventricular/fisiopatologia , Fatores de Tempo , Resultado do Tratamento
14.
J Cardiovasc Electrophysiol ; 21(10): 1079-84, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-20455974

RESUMO

AIMS: A robotic navigation system (RNS, Hansen™) has been developed as an alternative method of performing ablation for atrial fibrillation (AF). Despite the growing application of RNS-guided pulmonary vein isolation (PVI), its consequences and mechanisms of subsequent AF recurrences are unknown. We investigated the acute procedural success and persistence of PVI over time after robotic PVI and its relation to clinical outcome. METHODS AND RESULTS: Sixty-four patients (60.7 ± 9.8 years, 53 male) with paroxysmal AF underwent robotic circumferential PVI with 3-dimensional left atrial reconstruction (NavX™). A voluntary repeat invasive electrophysiological study was performed 3 months after ablation irrespective of clinical course. Robotic PVI was successful in all patients without complication (fluoroscopy time: 23.5 [12-34], procedure time: 180 [150-225] minutes). Fluoroscopy time demonstrated a gradual decline but was significantly reduced after the 30th patient following the introduction of additional navigation software (34 [29-45] vs 12 [9-17] minutes; P < 0.001). A repeat study at 3 months was performed in 63% of patients and revealed electrical conduction recovery in 43% of all PVs. Restudied patients without AF recurrence (n = 28) showed a significantly lower number of recovered PVs (1 (0-2) vs 2 (2-3); P = 0.006) and a longer LA-PV conduction delay than patients with AF recurrences (n = 12). Persistent block of all PVs was associated with freedom from AF in all patients. At 3 months, 67% of patients were free of AF, while reablation of recovered PVs led to an overall freedom from AF in 81% of patients after 1 year. CONCLUSION: Robotic PVI for PAF is safe, effective, and requires limited fluoroscopy while yielding comparable success rates to conventional ablation approaches with PV reconduction as a common phenomenon associated with AF recurrences.


Assuntos
Fibrilação Atrial/cirurgia , Sistema de Condução Cardíaco/cirurgia , Veias Pulmonares/cirurgia , Robótica/métodos , Cirurgia Assistida por Computador/métodos , Telemedicina/métodos , Fibrilação Atrial/diagnóstico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva , Resultado do Tratamento
15.
Int J Cardiol ; 145(2): 368-370, 2010 Nov 19.
Artigo em Inglês | MEDLINE | ID: mdl-20303606

RESUMO

A pilot study was performed to determine the efficacy of low energy biphasic external cardioversion in common type atrial flutter. In the majority of patients (70%) successful cardioversion was achieved with low energy levels of 20 or 30 J; however a considerable number of patients (15%) were initially cardioverted to atrial fibrillation, needing an additional cardioversion with an even higher energy level.


Assuntos
Flutter Atrial/metabolismo , Flutter Atrial/terapia , Cardioversão Elétrica , Metabolismo Energético/fisiologia , Idoso , Flutter Atrial/fisiopatologia , Cardioversão Elétrica/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Estudos Prospectivos
16.
Circ Arrhythm Electrophysiol ; 3(2): 160-9, 2010 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-20133933

RESUMO

BACKGROUND: Atrial tachycardias (AT) often occur after ablation of long-lasting persistent AF (CAF) and are difficult to treat conservatively. This study evaluated mechanisms and success rates of conventional mapping and catheter ablation of recurrent ATs occurring late after stepwise ablation of CAF. METHODS AND RESULTS: A total of 320 patients underwent de novo ablation of CAF using a stepwise ablation approach in 2006 to 2007 at our institution. This study comprised patients who presented with recurrent ATs at their first redo procedure after initial de novo CAF ablation. All procedures were guided by conventional mapping techniques exclusively. Sixty-one patients (63+/-10 years, 14 women) presented with their clinical AT at their redo procedure 7.7+/-4.4 months after initial de novo CAF ablation. A total of 133 ATs (2.2+/-0.9 per patient) were mapped. Forty-four (72%) were due to reentry; 17 (28%) were focal ATs. Reentry ATs were mainly characterized as roof and perimitral flutter (43% and 34%, respectively). Focal ATs mainly originated from the great thoracic veins (pulmonary veins: 41%, coronary sinus: 23%). Forty-five (74%) patients had conduction recovery of at least 1 pulmonary vein (mean, 1.2+/-0.8). Overall, 124 (93%) ATs could be ablated successfully. The mean procedure duration was 181+/-59 minutes, with a mean fluoroscopy time of 45+/-21 minutes. After a mean follow-up of 21+/-4 months, 50 (82%) patients were free of any arrhythmia recurrences after a single redo procedure. CONCLUSIONS: Although late recurrent ATs may have complex mechanisms, catheter ablation guided exclusively by conventional techniques is highly effective with excellent acute and long-term success rates.


Assuntos
Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/cirurgia , Ablação por Cateter/estatística & dados numéricos , Taquicardia Atrial Ectópica/fisiopatologia , Taquicardia Atrial Ectópica/cirurgia , Idoso , Fibrilação Atrial/epidemiologia , Eletrocardiografia/estatística & dados numéricos , Técnicas Eletrofisiológicas Cardíacas/estatística & dados numéricos , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/epidemiologia , Recidiva , Taquicardia Atrial Ectópica/epidemiologia , Resultado do Tratamento
17.
J Cardiovasc Electrophysiol ; 21(1): 6-12, 2010 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-19793149

RESUMO

BACKGROUND: Recently, a nonmagnetic robotic navigation system (RN, Hansen-Sensei) has been introduced for remote catheter manipulation. OBJECTIVE: To investigate the influence of RN combined with intuitive 3-dimensional mapping on the fluoroscopy exposure to operator and patient during pulmonary vein isolation (PVI) for paroxysmal atrial fibrillation (PAF) in a prospective randomized trial. METHODS: Sixty patients were randomly assigned to undergo PVI either using a RN guided (group 1; n = 30, 20 male, 62 +/- 7.7 years) or conventional ablation approach (group 2; n = 30, 14 male, 61 +/- 7.6 years). A 3-dimensional mapping system (NavX) was used in both groups. RESULTS: Electrical disconnection of the ipsilateral pulmonary veins (PVs) was achieved in all patients. Use of RN significantly lowered the overall fluoroscopy time (9 +/- 3.4 vs 22 +/- 6.5 minutes; P < 0.001) and reduced the operator's fluoroscopy exposure (7 +/- 2.1 vs 22 +/- 6.5 minutes; P < 0.001). The difference in fluoroscopy duration between both groups was most pronounced during the ablation part of the procedure (3 +/- 2.4 vs 17 +/- 6.3 minutes; P < 0.001). The overall procedure duration tended to be prolonged using RN without reaching statistical significance (156 +/- 44.4 vs 134 +/- 12 minutes, P = 0.099). No difference regarding outcome was found during a midterm follow-up of 6 months (AF freedom group 1 = 73% vs 77% in group 2 [P = 0.345]). CONCLUSION: The use of RN for PVI seems to be effective and significantly reduces overall fluoroscopy time and operator's fluoroscopy exposure without affecting mid-term outcome after 6-month follow-up.


Assuntos
Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Mapeamento Potencial de Superfície Corporal/métodos , Ablação por Cateter/métodos , Doses de Radiação , Robótica/métodos , Cirurgia Assistida por Computador/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Radiografia , Resultado do Tratamento
18.
Cardiology ; 111(1): 57-62, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18239394

RESUMO

BACKGROUND: External cardioversion is effective to terminate persistent atrial flutter. Biphasic shocks have been shown to be superior to monophasic shocks for ventricular defibrillation and atrial fibrillation cardioversion. The purpose of this trial was to compare the efficacy of rectilinear biphasic versus standard damped sine wave monophasic shocks in symptomatic patients with typical atrial flutter. METHODS: 135 consecutive patients were screened, 95 (70 males, mean age 62 +/- 13 years) were included. Patients were randomly assigned to a monophasic or biphasic cardioversion protocol. Forty-seven patients randomized to the monophasic protocol received sequential shocks of 100, 150, 200, 300 and 360 J. Forty-eight patients with the biphasic protocol received 50, 75, 100, 150 or 200 J. RESULTS: First-shock efficacy with 50-Joule, biphasic shocks (23/48 patients, 48%) was significantly greater than with the 100-Joule, monophasic waveform (13/47 patients, 28%, p = 0.04). The cumulative second-shock efficacy with the 50- and 75-Joule, biphasic waveform (39/48 patients, 81%) was significantly greater than with the 100- and 150-Joule, monophasic waveform (25/47 patients, 53%, p < 0.05). The cumulative efficacy for the higher energy levels showed naturally no significant difference between the two groups. The amount of the mean delivered energy was significantly lower in the biphasic group (76 +/- 39 J) compared to the monophasic one (177 +/- 78 J, p < 0.05). CONCLUSIONS: For transthoracic cardioversion of typical atrial flutter, biphasic shocks have greater efficacy and the mean delivered current is lower than for monophasic shocks. Therefore, biphasic cardioversion with lower starting energies should be recommended.


Assuntos
Flutter Atrial/terapia , Cardioversão Elétrica/instrumentação , Idoso , Cardioversão Elétrica/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Resultado do Tratamento
19.
Int J Cardiol ; 128(1): 104-6, 2008 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-17706810

RESUMO

We report a female patient with a ventricular lead perforation late after implantation. The lead perforated heart and lung parenchyma and caused hemothorax but no cardiac effusion or tamponade. No definitive evidence for lead perforation was found by standard diagnostic assessment. Definitive diagnosis was established by cath-lab fluoroscopy. The surgical treatment including thoracotomy, lead removal, repair suture of the right ventricle and finally placement of an epicardial electrode was successful.


Assuntos
Fluoroscopia , Traumatismos Cardíacos/diagnóstico por imagem , Traumatismos Cardíacos/etiologia , Hemotórax/diagnóstico por imagem , Hemotórax/etiologia , Lesão Pulmonar , Pulmão/diagnóstico por imagem , Marca-Passo Artificial/efeitos adversos , Idoso , Remoção de Dispositivo , Feminino , Traumatismos Cardíacos/cirurgia , Hemotórax/cirurgia , Humanos , Pulmão/cirurgia , Punções
20.
Cardiology ; 107(4): 380-5, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17284899

RESUMO

BACKGROUND: Vasovagal syncope is triggered by complex cerebral and cardiovascular reflex mechanisms leading to general vasodilatation and bradycardia resulting in cerebral hypoperfusion. METHODS: We prospectively studied the correlation of postural blood pressure test (PBT) and head-up tilt table test (TT) in patients with recurrent vasovagal syncope. Sixty-eight patients (37 male, 52.4 +/- 18.6 years) were included in the trial. They were asked to participate in a PBT and a TT. Independent samples t-test, ANOVA and Fisher's exact test were used for statistical analysis. p values <0.05 were considered statistically significant. RESULTS: Thirty patients (44%) showed a positive TT and thirty-four patients (50%) had a positive PBT. PBT did not show any correlation with TT, although pathophysiological mechanisms in vasovagal syncope and orthostatic hypotension are supposed to be similar. Furthermore neither TT nor PBT nor their combination had any predictive value for the patient's risk of syncope recurrence. CONCLUSIONS: TT and PBT are not correlated with each other. Both investigations cannot predict the patient's risk of syncope recurrence.


Assuntos
Determinação da Pressão Arterial , Hipotensão Ortostática/diagnóstico , Síncope Vasovagal/diagnóstico , Teste da Mesa Inclinada , Adulto , Idoso , Pressão Sanguínea/fisiologia , Feminino , Humanos , Hipotensão Ortostática/complicações , Masculino , Pessoa de Meia-Idade , Postura/fisiologia , Estudos Prospectivos , Recidiva , Síncope Vasovagal/etiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...