Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Rev Sci Instrum ; 92(5): 053538, 2021 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-34243326

RESUMO

A poloidal array of scintillator-based Fast-Ion Loss Detectors (FILDs) has been installed in the ASDEX Upgrade (AUG) tokamak. While all AUG FILD systems are mounted on reciprocating arms driven externally by servomotors, the reciprocating system of the FILD probe located just below the midplane is based on a magnetic coil that is energized in real-time by the AUG discharge control system. This novel reciprocating system allows, for the first time, real-time control of the FILD position including infrared measurements of its probe head temperature to avoid overheating. This considerably expands the diagnostic operational window, enabling unprecedented radial measurements of fast-ion losses. Fast collimator-slit sweeping (up to 0.2 mm/ms) is used to obtain radially resolved velocity-space measurements along 8 cm within the scrape-off layer. This provides a direct evaluation of the neutral beam deposition profiles via first-orbit losses. Moreover, the light-ion beam probe (LIBP) technique is used to infer radial profiles of fast-ion orbit deflection. This radial-LIBP technique is applied to trapped orbits (exploring both the plasma core and the FILD stroke near the wall), enabling radial localization of internal plasma fluctuations (neoclassical tearing modes). This is quantitatively compared against electron cyclotron emission measurements, showing excellent agreement. For the first time, radial profiles of fast-ion losses in MHD quiescent plasmas as well as in the presence of magnetic islands and edge localized modes are presented.

2.
Rev Sci Instrum ; 92(4): 043554, 2021 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-34243403

RESUMO

An Imaging Neutral Particle Analyzer (INPA) diagnostic has been designed for the ASDEX Upgrade (AUG) tokamak. The AUG INPA diagnostic will measure fast neutrals escaping the plasma after charge exchange reactions. The neutrals will be ionized by a 20 nm carbon foil and deflected toward a scintillator by the local magnetic field. The use of a neutral beam injector (NBI) as an active source of neutrals will provide radially resolved measurements, while the use of a scintillator as an active component will allow us to cover the whole plasma along the NBI line with unprecedented phase-space resolution (<12 keV and 8 cm) and a fast temporal response (up to 1 kHz with the high resolution acquisition system and above 100 kHz with the low resolution one), making it suitable to study localized fast-ion redistributions in phase space.

3.
Rev Sci Instrum ; 89(10): 10I112, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30399654

RESUMO

The design and unique feature of the first fast-ion loss detector (FILD) for the Mega Amp Spherical Tokamak - Upgrade (MAST-U) is presented here. The MAST-U FILD head is mounted on an axially and angularly actuated mechanism that makes it possible to independently adapt the orientation [0°, 90°] and radial position [1.40 m, 1.60 m] of the FILD head, i.e., its collimator, thus maximizing the detector velocity-space coverage in a broad range of plasma scenarios with different q95. The 3D geometry of the detector has been optimized to detect fast-ion losses from the neutral beam injectors. Orbit simulations are used to calculate the strike map and predict the expected signals. The results show a velocity-space range of [4 cm, 13 cm] in gyroradius and [30°, 85°] in pitch angle, covering the entire neutral beam ion energy range. The optical system will provide direct sight of the scintillator and simultaneous detection with two cameras, giving high spatial and temporal resolution. The MAST-U FILD will shed light on the dominant fast-ion transport mechanisms in one of the world's two largest spherical tokamaks through absolute measurements of fast-ion losses.

4.
Rev Sci Instrum ; 89(10): 10I106, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30399966

RESUMO

A new reciprocating scintillator based fast-ion loss detector has been installed a few centimeters above the outer divertor of the ASDEX Upgrade tokamak and between two of its lower Edge Localized Modes (ELM) mitigation coils. The detector head containing the scintillator screen, Faraday cup, calibration lamp, and collimator systems are installed on a motorized reciprocating system that can adjust its position via remote control in between plasma discharges. Orbit simulations are used to optimize the detector geometry and velocity-space coverage. The scintillator image is transferred to the light acquisition systems outside of the vacuum via a lens relay (embedded in a 3D-printed titanium holder) and an in-vacuum image guide. A charge coupled device camera, for high velocity-space resolution, and an 8 × 8 channel avalanche photo diode camera, for high temporal resolution (up to 2 MHz), are used as light acquisition systems. Initial results showing velocity-space of neutral beam injection prompt losses and fast-ion losses induced by a (2, 1) neoclassical tearing mode are presented.

5.
Rev Sci Instrum ; 87(11): 11E705, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27910655

RESUMO

A magnetically driven fast-ion loss detector system for the ASDEX Upgrade tokamak has been designed and will be presented here. The device is feedback controlled to adapt the detector head position to the heat load and physics requirements. Dynamic simulations have been performed taking into account effects such as friction, coil self-induction, and eddy currents. A real time positioning control algorithm to maximize the detector operational window has been developed. This algorithm considers dynamical behavior and mechanical resistance as well as measured and predicted thermal loads. The mechanical design and real time predictive algorithm presented here may be used for other reciprocating systems.

6.
Rev Sci Instrum ; 87(11): 11D829, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27910499

RESUMO

A conceptual design of a reciprocating fast-ion loss detector for ITER has been developed and is presented here. Fast-ion orbit simulations in a 3D magnetic equilibrium and up-to-date first wall have been carried out to revise the measurement requirements for the lost alpha monitor in ITER. In agreement with recent observations, the simulations presented here suggest that a pitch-angle resolution of ∼5° might be necessary to identify the loss mechanisms. Synthetic measurements including realistic lost alpha-particle as well as neutron and gamma fluxes predict scintillator signal-to-noise levels measurable with standard light acquisition systems with the detector aperture at ∼11 cm outside of the diagnostic first wall. At measurement position, heat load on detector head is comparable to that in present devices.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...