Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Korean J Radiol ; 18(6): 881-887, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29089820

RESUMO

OBJECTIVE: Using a pulsating coronary artery phantom at high heart rate settings, we investigated the efficacy of a motion correction algorithm (MCA) to improve the image quality in dual-energy spectral coronary CT angiography (CCTA). MATERIALS AND METHODS: Coronary flow phantoms were scanned at heart rates of 60-100 beats/min at 10-beats/min increments, using dual-energy spectral CT mode. Virtual monochromatic images were reconstructed from 50 to 90 keV at 10-keV increments. Two blinded observers assessed image quality using a 4-point Likert Scale (1 = non-diagnostic, 4 = excellent) and the fraction of interpretable segments using MCA versus conventional algorithm (CA). Comparison of variables was performed with the Wilcoxon rank sum test and McNemar test. RESULTS: At heart rates of 70, 80, 90, and 100 beats/min, images with MCA were rated as higher image scores compared to those with CA on monochromatic levels of 50, 60, and 70 keV (each p < 0.05). Meanwhile, at a heart rate of 90 beats/min, image interpretability was improved by MCA at a monochromatic level of 60 keV (p < 0.05) and 70 keV (p < 0.05). At a heart rate of 100 beats/min, image interpretability was improved by MCA at monochromatic levels of 50 keV (from 69.4% to 86.1%, p < 0.05), 60 keV (from 55.6% to 83.3%, p < 0.05) and 70 keV (from 33.3% to 69.3%, p < 0.05). CONCLUSION: Low-keV monochromatic images combined with MCA improves image quality and image interpretability in CCTAs at high heart rates.


Assuntos
Algoritmos , Angiografia por Tomografia Computadorizada/métodos , Vasos Coronários/diagnóstico por imagem , Frequência Cardíaca/fisiologia , Angiografia por Tomografia Computadorizada/instrumentação , Vasos Coronários/fisiologia , Humanos , Interpretação de Imagem Radiográfica Assistida por Computador , Reprodutibilidade dos Testes
2.
PLoS One ; 10(7): e0132412, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26167680

RESUMO

To determine whether body weight and concentration dependent contrast medium (CM) injection protocols can improve patient to patient CT value uniformity more than the conventional injection protocols with fixed injection parameters in coronary CT angiography (CCTA), one hundred and sixty patients who underwent CCTA were prospectively randomized into two groups. Group A (n = 80) used individualized-protocol with adjusted injection rate based on patient weight and contrast medium concentration to obtain constant iodine load of 280 mgI/kg while group B (n = 80) followed the conventional contrast injection protocol with total injection volume of 80ml and constant injection rate of 5.5ml/s. For both groups, patients were further divided into four subgroups with different CM concentrations: A1, B1 (300 mg I/ml); A2, B2 (320 mg I/ml); A3, B3 (350 mg I/ml) and A4 and B4 (370 mg I/ml). For each patient, the CT values of the ascending aorta, left ventricle and coronary arteries were measured. One-way analysis of variance was used to compare CT values among subgroups. Among the subgroups of A, sufficient attenuation of greater than 300HU was obtained in all target vessels with no difference among them. Among the subgroups of B, the CT values had significant difference in left ventricle, left circumflex branch, proximal and distal segment of the right coronary artery (all p < 0.05), and the attenuation with 300 mg I/ml CM concentration was significantly lower than that with 370 mg I/ml. Compared with group B, group A used less volume (62.83 ml vs. 80.00 ml, P<0.001) and lower rate (5.21 ml/s vs. 5.50 ml/s, P<0.001) of CM. Compared with the conventional contrast medium injection protocol with fixed volume and injection rate, the individualized-protocol based on patient weight and contrast concentration provides overall contrast dose reduction and achieves more homogenous attenuation among different coronary vessels and patients.


Assuntos
Meios de Contraste/uso terapêutico , Angiografia Coronária/métodos , Tomografia Computadorizada por Raios X/métodos , Aortografia/métodos , Peso Corporal , Protocolos Clínicos , Meios de Contraste/administração & dosagem , Doença da Artéria Coronariana/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Feminino , Ventrículos do Coração/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Tomografia Computadorizada por Raios X/normas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...