Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Cardiovasc Ultrasound ; 14(1): 36, 2016 Aug 24.
Artigo em Inglês | MEDLINE | ID: mdl-27553013

RESUMO

BACKGROUND: Not all echo laboratories have the capability of measuring direct online 3D images, but do have the capability of turning 3D images into 2D ones "online" for bedside measurements. Thus, we hypothesized that a simple and rapid rotation of the sagittal view (green box, x-plane) that shows all needed left atrial appendage (LAA) number of lobes, orifice area, maximal and minimal diameters and depth parameters on the 3D transesophageal echocardiography (3DTEE) image and LAA measurements after turning the images into 2D (Rotational 3DTEE/"Yosefy Rotation") is as accurate as the direct measurement on real-time-3D image (RT3DTEE). METHODS: We prospectively studied 41 consecutive patients who underwent a routine TEE exam, using QLAB 10 Application on EPIQ7 and IE33 3D-Echo machine (BORTHEL Phillips) between 01/2013 and 12/2015. All patients underwent 64-slice CT before pulmonary vein isolation or for workup of pulmonary embolism. LAA measurements were compared between RT3DTEE and Rotational 3DTEE versus CT. RESULTS: Rotational 3DTEE measurements of LAA were not statistically different from RT3DTEE and from CT regarding: number of lobes (1.6 ± 0.7, 1.6 ± 0.6, and 1.4 ± 0.6, respectively, p = NS for all); internal area of orifice (3.1 ± 0.6, 3.0 ± 0.7, and 3.3 ± 1.5 cm(2), respectively, p = NS for all); maximal LAA diameter (24.8 ± 4.5, 24.6 ± 5.0, and 24.9 ± 5.8 mm, respectively, p = NS for all); minimal LAA diameter (16.4 ± 3.4, 16.7 ± 3.3, and 17.0 ± 4.4 mm, respectively, p = NS for all), and LAA depth (20.0 ± 2.1, 19.8 ± 2.2, and 21.7 ± 6.9 mm, respectively, p = NS for all). CONCLUSION: Rotational 3DTEE method for assessing LAA is a simple, rapid and feasible method that has accuracy similar to that of RT3DTEE and CT. Thus, rotational 3DTEE ("Yosefy rotation") may facilitate LAA closure procedure by choosing the appropriate device size.


Assuntos
Apêndice Atrial/diagnóstico por imagem , Fibrilação Atrial/diagnóstico , Função do Átrio Esquerdo/fisiologia , Ecocardiografia Tridimensional/métodos , Ecocardiografia Transesofagiana/métodos , Apêndice Atrial/fisiopatologia , Fibrilação Atrial/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Reprodutibilidade dos Testes
2.
Echocardiography ; 33(1): 69-76, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26053456

RESUMO

AIMS: Currently, two-dimensional transesophageal echocardiography (2DTEE) at a cut-plane angulation of 135° is the recommended method to size maximal left atrial appendage (LAA) orifice diameter before introducing a percutaneous LAA closure device. We compared real time three-dimensional TEE (RT3DTEE) and 2DTEE for measuring LAA dimensions versus computed tomography (CT) as gold standard. METHODS AND RESULTS: We prospectively studied 30 consecutive patients who underwent a routine TEE examination, using QLAB 10.0 Application on EPIQ7 iE33 3D echo machine between December 2012 and December 2013. All patients underwent 64-slice CT before pulmonary vein isolation or for workup of pulmonary embolism. LAA measurements were compared between 135 2DTEE and RT3DTEE. Results were compared with CT measurements. Using RT3DTEE, larger LAA diameters were measured versus 2DTEE (23.5 ± 3.9 vs. 24.5 ± 4.7 mm). In seven patients (23.3%), the measurements in 135° 2DTEE were smaller than the cut-plane angulation with maximal orifice diameter. RT3DTEE measurements of LAA were not different from CT regarding number of lobes, area of orifice, and maximal diameter. LAA volume could not be measured directly using RT3DTEE. No difference was found between LAA depth using RT3DTEE (19.5 ± 2.3 mm) vs. CT (19.6 ± 2.3, P = NS) and 2DTEE (19.4 ± 2.2 mm) vs. CT (P = NS). However, RT3DTEE (24.5 ± 4.7 mm) vs. CT (24.6 ± 5, P = NS) was more accurate in measuring maximal LAA diameter compared to 2DTEE (23.5 ± 3.9 mm) vs. CT (P < 0.01). CONCLUSION: RT3DTEE method is more accurate than 2DTEE for assessment of maximal LAA orifice diameter. Bedsides, RT3DTEE LAA measurements are not statistically different from CT. Thus, RT3DTEE may facilitate LAA closure procedure by choosing the appropriate device size.


Assuntos
Apêndice Atrial/diagnóstico por imagem , Ecocardiografia Tridimensional/métodos , Ecocardiografia Transesofagiana/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA