Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Curr Opin Biotechnol ; 7(1): 55-9, 1996 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-8742377

RESUMO

Non-invasive measurement of the neuromodulatory activity of certain analytes is now possible through the use of biomagnetic stimulation and detection techniques. The timely development of room-temperature instrumentation and of more effective techniques for coupling neurons to transducers are the critical elements for rapid progress in this field.


Assuntos
Técnicas Biossensoriais , Neurologia/instrumentação , Neurônios/fisiologia , Animais , Humanos , Magnetismo , Monitorização Fisiológica/instrumentação , Monitorização Fisiológica/métodos , Neurologia/métodos
2.
Anal Chem ; 68(9): 1671-5, 1996 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-21619135

RESUMO

Biomagnetic neurosensors based on magnetic stimulation and magnetic detection of neural events depend critically upon the effective matching of the magnetic transducers and the neural tissue employed. Although the properties of wire-wrapped ferrite core transducers can be predicted from electromagnetic fundamentals, meaningful analytical measurements using real nerves as molecular recognition elements require additional calibration and optimization steps in order to achieve good system response and lifetimes. This note provides some design guidelines and experimental test procedures to enable potential users to employ biomagnetic neurosensors in other laboratories.

3.
Anal Chem ; 67(4): 763-9, 1995 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-7702191

RESUMO

A noninvasive biomagnetic sensor system that uses magnetic toroids for both neural stimulation and detection is described. It is shown that analytical signals obtained by direct magnetic detection (no signal averaging) compare favorably with electrical monitoring and that dose-response curves for local anesthetics correlate well between the two methods. Neural lifetimes are significantly extended when the noninvasive biomagnetic sensing system is used.


Assuntos
Técnicas Biossensoriais , Magnetismo , Fibras Nervosas/efeitos dos fármacos , Potenciais de Ação , Anestésicos Locais/farmacologia , Animais , Astacoidea/fisiologia , Relação Dose-Resposta a Droga , Eletrodos , Fibras Nervosas/fisiologia , Canais de Sódio/efeitos dos fármacos
4.
Anal Chem ; 66(19): 3193-7, 1994 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-7978307

RESUMO

We report the generation of action potentials in crayfish neurons by magnetic pulses for analytical purposes. A copper wire toroid, containing a ferrite core, was placed around the nerve bundle, and square wave current pulses were sent through the wire to generate a magnetic field. The magnetic field generated an action potential in the neuron that was detected downfield by a pickup microelectrode. The biosensor was used to detect local anesthetics by monitoring the time necessary for complete blockage of the action potential. Techniques for improving the efficiency and lifetimes of neural biosensors are discussed.


Assuntos
Técnicas Biossensoriais , Magnetismo , Neurônios/fisiologia , Potenciais de Ação , Anestésicos Locais , Animais , Astacoidea
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA