Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 433
Filtrar
1.
MAGMA ; 2024 May 04.
Artigo em Inglês | MEDLINE | ID: mdl-38703246

RESUMO

OBJECTIVE: Diffusion-weighted MRI is a technique that can infer microstructural and microcirculatory features from biological tissue, with particular application to renal tissue. There is extensive literature on diffusion tensor imaging (DTI) of anisotropy in the renal medulla, intravoxel incoherent motion (IVIM) measurements separating microstructural from microcirculation effects, and combinations of the two. However, interpretation of these features and adaptation of more specific models remains an ongoing challenge. One input to this process is a whole organ distillation of corticomedullary contrast of diffusion metrics, as has been explored for other renal biomarkers. MATERIALS AND METHODS: In this work, we probe the spatial dependence of diffusion MRI metrics with concentrically layered segmentation in 11 healthy kidneys at 3 T. The metrics include those from DTI, IVIM, a combined approach titled "REnal Flow and Microstructure AnisotroPy (REFMAP)", and a multiply encoded model titled "FC-IVIM" providing estimates of fluid velocity and branching length. RESULTS: Fractional anisotropy decreased from the inner kidney to the outer kidney with the strongest layer correlation in both parenchyma (including cortex and medulla) and medulla with Spearman correlation coefficients and p-values (r, p) of (0.42, <0.001) and (0.37, <0.001), respectively. Also, dynamic parameters derived from the three models significantly decreased with a high correlation from the inner to the outer parenchyma or medulla with (r, p) ranges of (0.46-0.55, <0.001). CONCLUSIONS: These spatial trends might find implications for indirect assessments of kidney physiology and microstructure using diffusion MRI.

2.
Acad Radiol ; 2024 Mar 04.
Artigo em Inglês | MEDLINE | ID: mdl-38443207

RESUMO

RATIONALE AND OBJECTIVES: To determine factors influencing low-field MRI lung opacity severity 6-24 months after acute Covid-19 pneumonia. MATERIALS AND METHODS: 104 post-acute Covid-19 patients with 167 MRI exams were included. 32 patients had more than one exam, and 63 exams were serial exams. Pulmonary findings were graded on a scale of 0-4 by quadrant, total score ranging from 0 (no opacity) to 16 (opacity > 75%), and score >8 considered moderate and >12 severe opacity. Kruskal-Wallis, Mann-Whitney, and Spearman rank correlation was used to assess the association of clinical and demographic factors with MR opacity severity at time intervals from acute infection. Random coefficients regression was used to assess whether opacity score changed over time. RESULTS: Severity of initial illness was associated with increased MR opacity score at timeframes up to 24 months (p < .05). Among the 167 exams, moderate to severe MR opacities (total opacity score >8) were identified in 33% of exams beyond 6 months: 37% at 6 - <12 months (n = 23/63); 31% at 12- < 18 months (n = 13/42); 25% at 18- < 24 months (n = 6/24); and 50% at > 24 months (n = 3/6). No significant change in total opacity score over time was identified by random coefficients regression. Among the 32 patients with serial exams, 11 demonstrated no change in opacity score from initial to final exam, 10 decrease in score (mean 2.3, stdev 1.25, range 1-4), and 11 increase in score (average 2.8, stdev 1.48, range 1-7). CONCLUSION: Initial Covid-19 disease severity was associated with increased MRI total opacity score at time intervals up to 24 months, and moderate to severe opacities were commonly identified by low-field MRI beyond 6 months from acute illness.

3.
J Am Coll Radiol ; 21(2): 309-318, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37247831

RESUMO

OBJECTIVE: To evaluate the efficacy of a multimodal intervention in reducing CT pulmonary angiography (CTPA) overutilization in the evaluation of suspected pulmonary embolism in the emergency department (ED). METHODS: Previous mixed-methods analysis of barriers to guideline-concordant CTPA ordering results was used to develop a provider-focused behavioral intervention consisting of a clinical decision support tool and an audit and feedback system at a multisite, tertiary academic network. The primary outcome (guideline concordance) and secondary outcomes (yield and CTPA and D-dimer order rates) were compared using a pre- and postintervention design. ED encounters for adult patients from July 5, 2017, to January 3, 2019, were included. Fisher's exact tests and statistical process control charts were used to compare the pre- and postintervention groups for each outcome. RESULTS: Of the 201,912 ED patient visits evaluated, 3,587 included CTPA. Guideline concordance increased significantly after the intervention, from 66.9% to 77.5% (P < .001). CTPA order rate and D-dimer order rate also increased significantly, from 17.1 to 18.4 per 1,000 patients (P = .035) and 30.6 to 37.3 per 1,000 patients (P < .001), respectively. Percent yield showed no significant change (12.3% pre- versus 10.8% postintervention; P = .173). Statistical process control analysis showed sustained special-cause variation in the postintervention period for guideline concordance and D-dimer order rates, temporary special-cause variation for CTPA order rates, and no special-cause variation for percent yield. CONCLUSION: Our success in increasing guideline concordance demonstrates the efficacy of a mixed-methods, human-centered approach to behavior change. Given that neither of the secondary outcomes improved, our results may demonstrate potential limitations to the guidelines directing the ordering of CTPA studies and D-dimer ordering.


Assuntos
Embolia Pulmonar , Adulto , Humanos , Embolia Pulmonar/diagnóstico por imagem , Serviço Hospitalar de Emergência , Produtos de Degradação da Fibrina e do Fibrinogênio , Projetos de Pesquisa , Angiografia , Tomografia Computadorizada por Raios X , Angiografia por Tomografia Computadorizada , Estudos Retrospectivos
4.
Eur Radiol ; 34(2): 1113-1122, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37594524

RESUMO

OBJECTIVES: To evaluate a dynamic half-Fourier acquired single turbo spin echo (HASTE) sequence following anterior cervical discectomy and fusion (ACDF) at the junctional level for adjacent segment degeneration comparing dynamic listhesis to radiographs and assessing dynamic cord contact and deformity during flexion-extension METHODS: Patients with ACDF referred for cervical spine MRI underwent a kinematic flexion-extension sagittal 2D HASTE sequence in addition to routine sequences. Images were independently reviewed by three radiologists for static/dynamic listhesis, and compared to flexion-extension radiographs. Blinded assessment of the HASTE sequence was performed for cord contact/deformity between neutral, flexion, and extension, to evaluate concordance between readers and inter-modality agreement. Inter-reader agreement for dynamic listhesis and impingement grade and inter-modality agreement for dynamic listhesis on MRI and radiographs was assessed using the kappa coefficient and percentage concordance. RESULTS: A total of 28 patients, mean age 60.2 years, were included. Mean HASTE acquisition time was 42 s. 14.3% demonstrated high grade dynamic stenosis (> grade 4) at the adjacent segment. There was substantial agreement for dynamic cord impingement with 70.2% concordance (kappa = 0.62). Concordance across readers for dynamic listhesis using HASTE was 81.0% (68/84) (kappa = 0.16) compared with 71.4% (60/84) (kappa = 0.40) for radiographs. Inter-modality agreement between flexion-extension radiographs and MRI assessment for dynamic listhesis across the readers was moderate (kappa = 0.41; 95% confidence interval: 0.16 to 0.67). CONCLUSIONS: A sagittal flexion-extension HASTE cine sequence provides substantial agreement between readers for dynamic cord deformity and moderate agreement between radiographs and MRI for dynamic listhesis. CLINICAL RELEVANCE STATEMENT: Degeneration of the adjacent segment with instability and myelopathy is one of the most common causes of pain and neurological deterioration requiring re-operation following cervical fusion surgery. KEY POINTS: • A real-time kinematic 2D sagittal HASTE flexion-extension sequence can be used to assess for dynamic listhesis, cervical cord, contact and deformity. • The additional kinematic cine sequence was well tolerated and the mean acquisition time for the 2D HASTE sequence was 42 s (range 31-44 s). • A sagittal flexion-extension HASTE cine sequence provides substantial agreement between readers for dynamic cord deformity and moderate agreement between radiographs and MRI for dynamic listhesis.


Assuntos
Vértebras Cervicais , Fusão Vertebral , Humanos , Pessoa de Meia-Idade , Vértebras Cervicais/diagnóstico por imagem , Vértebras Cervicais/cirurgia , Vértebras Cervicais/patologia , Fenômenos Biomecânicos , Imageamento por Ressonância Magnética/métodos , Radiografia , Discotomia
5.
Int J Cardiovasc Imaging ; 40(1): 167-176, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37891449

RESUMO

While there have been many descriptions of characteristic motion findings in left bundle branch block (LBBB), there are few published descriptions of such findings in right bundle branch block (RBBB). The purpose of this study was to assess the frequency of particular regional motion findings in cardiac magnetic resonance imaging (CMR) studies of patients with RBBB, compared with normal subjects. We focused on three distinctive motion patterns that can be seen in RBBB during early systole: delayed apex-ward motion of the RV base, "reverse septal flash", and "basal bulge". The presence and relative magnitude of these findings were independently scored by four experienced observers, in 3-chamber and 4-chamber CMR cines, for both normal subjects and patients with RBBB. These motion patterns were found to be strongly associated with the presence of RBBB. While only moderately sensitive, they were quite specific for RBBB, when present. In particular, with ROC analysis, a combined feature set of the findings in the 4-chamber view had an area under the curve of 0.81.This previously undescribed set of RBBB-associated early-systolic regional motion features (delayed apex-ward motion of the RV base, "reverse septal flash", and "basal bulge") is strongly suggestive of RBBB when present, particularly in the 4-chamber view. Although here evaluated with CMR, it is also likely to be associated with RBBB when seen with other cardiac imaging modalities.


Assuntos
Bloqueio de Ramo , Imageamento por Ressonância Magnética , Humanos , Bloqueio de Ramo/diagnóstico por imagem , Bloqueio de Ramo/complicações , Valor Preditivo dos Testes , Coração , Ventrículos do Coração , Eletrocardiografia
6.
J Thorac Imaging ; 2023 Sep 05.
Artigo em Inglês | MEDLINE | ID: mdl-37732714

RESUMO

PURPOSE: The purpose of this study was to identify differences in imaging features between patients with confirmed right middle lobe (RML) torsion compared to those suspected yet without torsion. MATERIALS AND METHODS: This retrospective study entailing a search of radiology reports from April 1, 2014, to April 15, 2021, resulted in 52 patients with suspected yet without lobar torsion and 4 with confirmed torsion, supplemented by 2 additional cases before the search period for a total of 6 confirmed cases. Four thoracic radiologists (1 an adjudicator) evaluated chest radiographs and computed tomography (CT) examinations, and Fisher exact and Mann-Whitney tests were used to identify any significant differences in imaging features (P<0.05). RESULTS: A reversed halo sign was more frequent for all readers (P=0.001) in confirmed RML torsion than patients without torsion (83.3% vs. 0% for 3 readers, one the adjudicator). The CT coronal bronchial angle between RML bronchus and bronchus intermedius was larger (P=0.035) in torsion (121.28 degrees) than nontorsion cases (98.26 degrees). Patients with torsion had a higher percentage of ground-glass opacity in the affected lobe (P=0.031). A convex fissure towards the adjacent lobe on CT (P=0.009) and increased lobe volume on CT (P=0.001) occurred more often in confirmed torsion. CONCLUSION: A reversed halo sign, larger CT coronal bronchial angle, greater proportion of ground-glass opacity, fissural convexity, and larger lobe volume on CT may aid in early recognition of the rare yet highly significant diagnosis of lobar torsion.

7.
Magn Reson Imaging ; 100: 93-101, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-36924807

RESUMO

PURPOSE: Diffusion-weighted imaging (DWI) of the abdomen has increased dramatically for both research and clinical purposes. Motion and static field inhomogeneity related challenges limit image quality of abdominopelvic imaging with the most conventional echo-planar imaging (EPI) pulse sequence. While reversed phase encoded imaging is increasingly used to facilitate distortion correction, it typically assumes one motion independent magnetic field distribution. In this study, we describe a more generalized workflow for the case of kidney DWI in which the field inhomogeneity at multiple respiratory phases is mapped and used to correct all images in a multi-contrast DWI series. METHODS: In this HIPAA-compliant and IRB-approved prospective study, 8 volunteers (6 M, ages 28-51) had abdominal imaging performed in a 3 T MRI system (MAGNETOM Prisma; Siemens Healthcare, Erlangen, Germany) with ECG gating. Coronal oblique T2-weighted HASTE images were collected for anatomical reference. Sagittal phase-contrast (PC) MRI images through the left renal artery were collected to determine systolic and diastolic phases. Cardiac triggered oblique coronal DWI were collected at 10 b-values between 0 and 800 s/mm2 and 12 directions. DWI series were distortion corrected using field maps generated by forward and reversed phase encoded b = 0 images collected over the full respiratory cycle and matched by respiratory phase. Morphologic accuracy, intraseries spatial variability, and diffusion tensor imaging (DTI) metrics mean diffusivity (MD) and fractional anisotropy (FA) were compared for results generated with no distortion correction, correction with only one respiratory bin, and correction with multiple respiratory bins across the breathing cycle. RESULTS: Computed field maps showed significant variation in static field with kidney laterality, region, and respiratory phase. Distortion corrected images showed significantly better registration to morphologic images than uncorrected images; for the left kidney, the multiple bin correction outperformed one bin correction. Line profile analysis showed significantly reduced spatial variation with multiple bins than one bin correction. DTI metrics were mostly similar between correction methods, with some differences observed in MD between uncorrected and corrected datasets. CONCLUSIONS: Our results indicate improved morphology of kidney DWI and derived parametric maps as well as reduced variability over the full image series using the motion-resolved distortion correction. This work highlights some morphologic and quantitative metric improvements can be obtained for kidney DWI when distortion correction is performed in a respiratory-resolved manner.


Assuntos
Imagem de Difusão por Ressonância Magnética , Imagem de Tensor de Difusão , Humanos , Adulto , Pessoa de Meia-Idade , Estudos Prospectivos , Imagem de Difusão por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética , Rim/diagnóstico por imagem , Imagem Ecoplanar/métodos , Movimento (Física)
8.
J Comput Assist Tomogr ; 47(2): 212-219, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36790870

RESUMO

PURPOSE: To assess deep learning denoised (DLD) computed tomography (CT) chest images at various low doses by both quantitative and qualitative perceptual image analysis. METHODS: Simulated noise was inserted into sinogram data from 32 chest CTs acquired at 100 mAs, generating anatomically registered images at 40, 20, 10, and 5 mAs. A DLD model was developed, with 23 scans selected for training, 5 for validation, and 4 for test.Quantitative analysis of perceptual image quality was assessed with Structural SIMilarity Index (SSIM) and Fréchet Inception Distance (FID). Four thoracic radiologists graded overall diagnostic image quality, image artifact, visibility of small structures, and lesion conspicuity. Noise-simulated and denoised image series were evaluated in comparison with one another, and in comparison with standard 100 mAs acquisition at the 4 mAs levels. Statistical tests were conducted at the 2-sided 5% significance level, with multiple comparison correction. RESULTS: At the same mAs levels, SSIM and FID between noise-simulated and reconstructed DLD images indicated that images were closer to a perfect match with increasing mAs (closer to 1 for SSIM, and 0 for FID).In comparing noise-simulated and DLD images to standard-dose 100-mAs images, DLD improved SSIM and FID. Deep learning denoising improved SSIM of 40-, 20-, 10-, and 5-mAs simulations in comparison with standard-dose 100-mAs images, with change in SSIM from 0.91 to 0.94, 0.87 to 0.93, 0.67 to 0.87, and 0.54 to 0.84, respectively. Deep learning denoising improved FID of 40-, 20-, 10-, and 5-mAs simulations in comparison with standard-dose 100-mAs images, with change in FID from 20 to 13, 46 to 21, 104 to 41, and 148 to 69, respectively.Qualitative image analysis showed no significant difference in lesion conspicuity between DLD images at any mAs in comparison with 100-mAs images. Deep learning denoising images at 10 and 5 mAs were rated lower for overall diagnostic image quality ( P < 0.001), and at 5 mAs lower for overall image artifact and visibility of small structures ( P = 0.002), in comparison with 100 mAs. CONCLUSIONS: Deep learning denoising resulted in quantitative improvements in image quality. Qualitative assessment demonstrated DLD images at or less than 10 mAs to be rated inferior to standard-dose images.


Assuntos
Aprendizado Profundo , Humanos , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos , Processamento de Imagem Assistida por Computador/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Algoritmos , Razão Sinal-Ruído
9.
Neuroimage Clin ; 37: 103325, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36724732

RESUMO

PURPOSE: Proton magnetic resonance spectroscopy (1H MRS) offers biomarkers of metabolic damage after mild traumatic brain injury (mTBI), but a lack of replicability studies hampers clinical translation. In a conceptual replication study design, the results reported in four previous publications were used as the hypotheses (H1-H7), specifically: abnormalities in patients are diffuse (H1), confined to white matter (WM) (H2), comprise low N-acetyl-aspartate (NAA) levels and normal choline (Cho), creatine (Cr) and myo-inositol (mI) (H3), and correlate with clinical outcome (H4); additionally, a lack of findings in regional subcortical WM (H5) and deep gray matter (GM) structures (H6), except for higher mI in patients' putamen (H7). METHODS: 26 mTBI patients (20 female, age 36.5 ± 12.5 [mean ± standard deviation] years), within two months from injury and 21 age-, sex-, and education-matched healthy controls were scanned at 3 Tesla with 3D echo-planar spectroscopic imaging. To test H1-H3, global analysis using linear regression was used to obtain metabolite levels of GM and WM in each brain lobe. For H4, patients were stratified into non-recovered and recovered subgroups using the Glasgow Outcome Scale Extended. To test H5-H7, regional analysis using spectral averaging estimated metabolite levels in four GM and six WM structures segmented from T1-weighted MRI. The Mann-Whitney U test and weighted least squares analysis of covariance were used to examine mean group differences in metabolite levels between all patients and all controls (H1-H3, H5-H7), and between recovered and non-recovered patients and their respectively matched controls (H4). Replicability was defined as the support or failure to support the null hypotheses in accordance with the content of H1-H7, and was further evaluated using percent differences, coefficients of variation, and effect size (Cohen's d). RESULTS: Patients' occipital lobe WM Cho and Cr levels were 6.0% and 4.6% higher than controls', respectively (Cho, d = 0.37, p = 0.04; Cr, d = 0.63, p = 0.03). The same findings, i.e., higher patients' occipital lobe WM Cho and Cr (both p = 0.01), but with larger percent differences (Cho, 8.6%; Cr, 6.3%) and effect sizes (Cho, d = 0.52; Cr, d = 0.88) were found in the comparison of non-recovered patients to their matched controls. For the lobar WM Cho and Cr comparisons without statistical significance (frontal, parietal, temporal), unidirectional effect sizes were observed (Cho, d = 0.07 - 0.37; Cr, d = 0.27 - 0.63). No differences were found in any metabolite in any lobe in the comparison between recovered patients and their matched controls. In the regional analyses, no differences in metabolite levels were found in any GM or WM region, but all WM regions (posterior, frontal, corona radiata, and the genu, body, and splenium of the corpus callosum) exhibited unidirectional effect sizes for Cho and Cr (Cho, d = 0.03 - 0.34; Cr, d = 0.16 - 0.51). CONCLUSIONS: We replicated findings of diffuse WM injury, which correlated with clinical outcome (supporting H1-H2, H4). These findings, however, were among the glial markers Cho and Cr, not the neuronal marker NAA (not supporting H3). No differences were found in regional GM and WM metabolite levels (supporting H5-H6), nor in putaminal mI (not supporting H7). Unidirectional effect sizes of higher patients' Cho and Cr within all WM analyses suggest widespread injury, and are in line with the conclusion from the previous publications, i.e., that detection of WM injury may be more dependent upon sensitivity of the 1H MRS technique than on the selection of specific regions. The findings lend further support to the corollary that clinic-ready 1H MRS biomarkers for mTBI may best be achieved by using high signal-to-noise-ratio single-voxels placed anywhere within WM. The biochemical signature of the injury, however, may differ and therefore absolute levels, rather than ratios may be preferred. Future replication efforts should further test the generalizability of these findings.


Assuntos
Concussão Encefálica , Lesões Encefálicas , Humanos , Feminino , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Espectroscopia de Prótons por Ressonância Magnética , Concussão Encefálica/patologia , Espectroscopia de Ressonância Magnética/métodos , Prótons , Lesões Encefálicas/patologia , Encéfalo/patologia , Ácido Aspártico , Creatina/metabolismo , Colina/metabolismo
10.
Radiology ; 307(2): e220425, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36648347

RESUMO

Background MRI is a powerful diagnostic tool with a long acquisition time. Recently, deep learning (DL) methods have provided accelerated high-quality image reconstructions from undersampled data, but it is unclear if DL image reconstruction can be reliably translated to everyday clinical practice. Purpose To determine the diagnostic equivalence of prospectively accelerated DL-reconstructed knee MRI compared with conventional accelerated MRI for evaluating internal derangement of the knee in a clinical setting. Materials and Methods A DL reconstruction model was trained with images from 298 clinical 3-T knee examinations. In a prospective analysis, patients clinically referred for knee MRI underwent a conventional accelerated knee MRI protocol at 3 T followed by an accelerated DL protocol between January 2020 and February 2021. The equivalence of the DL reconstruction of the images relative to the conventional images for the detection of an abnormality was assessed in terms of interchangeability. Each examination was reviewed by six musculoskeletal radiologists. Analyses pertaining to the detection of meniscal or ligament tears and bone marrow or cartilage abnormalities were based on four-point ordinal scores for the likelihood of an abnormality. Additionally, the protocols were compared with use of four-point ordinal scores for each aspect of image quality: overall image quality, presence of artifacts, sharpness, and signal-to-noise ratio. Results A total of 170 participants (mean age ± SD, 45 years ± 16; 76 men) were evaluated. The DL-reconstructed images were determined to be of diagnostic equivalence with the conventional images for detection of abnormalities. The overall image quality score, averaged over six readers, was significantly better (P < .001) for the DL than for the conventional images. Conclusion In a clinical setting, deep learning reconstruction enabled a nearly twofold reduction in scan time for a knee MRI and was diagnostically equivalent with the conventional protocol. © RSNA, 2023 Supplemental material is available for this article. See also the editorial by Roemer in this issue.


Assuntos
Aprendizado Profundo , Masculino , Humanos , Imageamento por Ressonância Magnética/métodos , Articulação do Joelho/diagnóstico por imagem , Joelho/diagnóstico por imagem , Razão Sinal-Ruído
11.
J Magn Reson Imaging ; 58(1): 210-220, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36399101

RESUMO

BACKGROUND: Renal diffusion-weighted imaging (DWI) involves microstructure and microcirculation, quantified with diffusion tensor imaging (DTI), intravoxel incoherent motion (IVIM), and hybrid models. A better understanding of their contrast may increase specificity. PURPOSE: To measure modulation of DWI with cardiac phase and flow-compensated (FC) diffusion gradient waveforms. STUDY TYPE: Prospective. POPULATION: Six healthy volunteers (ages: 22-48 years, five females), water phantom. FIELD STRENGTH/SEQUENCE: 3-T, prototype DWI sequence with 2D echo-planar imaging, and bipolar (BP) or FC gradients. 2D Half-Fourier Single-shot Turbo-spin-Echo (HASTE). Multiple-phase 2D spoiled gradient-echo phase contrast (PC) MRI. ASSESSMENT: BP and FC water signal decays were qualitatively compared. Renal arteries and velocities were visualized on PC-MRI. Systolic (peak velocity), diastolic (end stable velocity), and pre-systolic (before peak velocity) phases were identified. Following mutual information-based retrospective self-registration of DWI within each kidney, and Marchenko-Pastur Principal Component Analysis (MPPCA) denoising, combined IVIM-DTI analysis estimated mean diffusivity (MD), fractional anisotropy (FA), and eigenvalues (λi) from tissue diffusivity (Dt ), perfusion fraction (fp ), and pseudodiffusivity (Dp , Dp,axial , Dp,radial ), for each tissue (cortex/medulla, segmented on b0/FA respectively), phase, and waveform (BP, FC). Monte Carlo water diffusion simulations aided data interpretation. STATISTICAL TESTS: Mixed model regression probed differences between tissue types and pulse sequences. Univariate general linear model analysis probed variations among cardiac phases. Spearman correlations were measured between diffusion metrics and renal artery velocities. Statistical significance level was set at P < 0.05. RESULTS: Water BP and FC signal decays showed no differences. Significant pulse sequence dependence occurred for λ1 , λ3 , FA, Dp , fp , Dp,axial , Dp,radial in cortex and medulla, and medullary λ2 . Significant cortex/medulla differences occurred with BP for all metrics except MD (systole [P = 0.224]; diastole [P = 0.556]). Significant phase dependence occurred for Dp , Dp,axial , Dp,radial for BP and medullary λ1 , λ2 , λ3 , MD for FC. FA correlated significantly with velocity. Monte Carlo simulations indicated medullary measurements were consistent with a 34 µm tubule diameter. DATA CONCLUSION: Cardiac gating and flow compensation modulate of measurements of renal diffusion. EVIDENCE LEVEL: 2 TECHNICAL EFFICACY STAGE: 2.


Assuntos
Imagem de Tensor de Difusão , Rim , Feminino , Humanos , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Imagem de Tensor de Difusão/métodos , Anisotropia , Estudos Prospectivos , Estudos Retrospectivos , Rim/diagnóstico por imagem , Imagem de Difusão por Ressonância Magnética/métodos , Movimento (Física) , Água
12.
Abdom Radiol (NY) ; 48(12): 3634-3642, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-36308554

RESUMO

PURPOSE: To assess the diagnostic performance of FDG-PET/MRI for the preoperative diagnosis and staging of peritoneal carcinomatosis (PC) using surgical Sugarbaker's PC index (PCI) as the reference in a multireader pilot study. METHODS: Fourteen adult patients (M/F: 3/11, mean age: 57 ± 12 year) with PC were prospectively included in this single-center study. Patients underwent FDG-PET/MRI prior to surgery (mean delay: 14 d, range: 1-63 d). Images were reviewed independently by 2 abdominal radiologists and 2 nuclear medicine physicians. The radiologists assessed contrast-enhanced abdominal MR images, while the nuclear medicine physicians assessed PET images fused with T2-weighted images. The abdomen was divided in 13 regions, scored from 0 to 3. A hybrid FDG-PET/MRI radiological PCI was created by combining the study data. Radiological PCI was compared to the surgical PCI on a per-patient and per-region basis. Inter-reader agreement was evaluated. RESULTS: Mean surgical PCI was 10 ± 8 (range: 0-24). Inter-reader agreement was almost perfect for all sets for radiologic PCI (Kappa: 0.81-0.98). PCI scores for all reading sets significantly correlated with the surgical PCI score (r range: 0.57-0.74, p range: < 0.001-0.003). Pooled per-patient sensitivity, specificity, and accuracy were 75%/50%/71.4% for MRI, 66.7%/50%/64.3% for FDG-PET, and 91.7%/50%/85.7% for FDG-PET/MRI, without significant difference (p value range 0.13-1). FDG-PET/MRI achieved 100% sensitivity and 100% specificity for a cutoff PCI of 20. Per-region sensitivity and accuracy were lower: 37%/61.8% for MRI, 17.8%/64.3% for FDG-PET, and 52.7%/60.4% for FDG-PET/MRI, with significantly higher sensitivity for FDG-PET/MRI. Per-region specificity was higher for FDG-PET (95%) compared to MRI (78.4%) and FDG-PET/MRI (66.5%). CONCLUSION: FDG-PET/MRI achieved an excellent diagnostic accuracy per-patient and weaker performance per-region for detection of PC. The added value of PET/MRI compared to MRI and FDG-PET remains to be determined.


Assuntos
Fluordesoxiglucose F18 , Neoplasias Peritoneais , Adulto , Humanos , Pessoa de Meia-Idade , Idoso , Neoplasias Peritoneais/diagnóstico por imagem , Neoplasias Peritoneais/cirurgia , Neoplasias Peritoneais/patologia , Projetos Piloto , Estudos Prospectivos , Imageamento por Ressonância Magnética/métodos , Tomografia por Emissão de Pósitrons , Compostos Radiofarmacêuticos , Estadiamento de Neoplasias
13.
Eur J Radiol ; 156: 110515, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36099832

RESUMO

PURPOSE: To evaluate detection and characterization of groundglass and fibrosis-like opacities imaged by non-contrast 0.55 Tesla MRI, and versus clinically-acquired chest CT images, in a cohort of post-Covid patients. MATERIALS AND METHODS: 64 individuals (26 women, mean age 53 ± 14 years, range 19-85) with history of Covid-19 pneumonia were recruited through a survivorship registry, with 106 non-contrast low-field 0.55 T cardiopulmonary MRI exams acquired from 9/8/2020-9/28/2021. MRI exams were obtained at an average interval of 9.5 ± 4.5 months from initial symptom report (range 1-18 months). Of these, 20 participants with 22 MRI exams had corresponding clinically-acquired CT chest imaging obtained within 30 days of MRI (average interval 18 ± 9 days, range 0-30). MR and CT images were reviewed and scored by two thoracic radiologists, for presence and extent of lung opacity by quadrant, opacity distribution, and presence versus absence of fibrosis-like subpleural reticulation and subpleural lines. Scoring was performed for each of four lung quadrants: right upper and middle lobe, right lower lobe, left upper lobe and lingula, and left lower lobe. Agreement between readers and modalities was assessed with simple and linear weighted Cohen's kappa (k) coefficients. RESULTS: Inter-reader concordance on CT for opacity presence, opacity extent, opacity distribution, and presence of subpleural lines and reticulation was 99%, 78%, 97%, 99%, and 94% (k 0.96, 0.86, 0.94, 0.97, 0.89), respectively. Inter-reader concordance on MR, among all 106 exams, for opacity presence, opacity extent, opacity distribution, and presence of subpleural lines and reticulation was 85%, 48%, 70%, 86%, and 76% (k 0.57, 0.32, 0.46, 0.47, 0.37), respectively. Inter-modality agreement between CT and MRI for opacity presence, opacity extent, opacity distribution, and presence subpleural lines and reticulation was 86%, 52%, 79%, 93%, and 76% (k 0.43, 0.63, 0.65, 0.80, 0.52). CONCLUSION: Low-field 0.55 T non-contrast MRI demonstrates fair to moderate inter-reader concordance, and moderate to substantial inter-modality agreement with CT, for detection and characterization of groundglass and fibrosis-like opacities.


Assuntos
COVID-19 , Humanos , Feminino , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Tomografia Computadorizada por Raios X/métodos , Imageamento por Ressonância Magnética/métodos , Pulmão/diagnóstico por imagem , Fibrose
14.
Neurobiol Dis ; 171: 105748, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35550158

RESUMO

BACKGROUND: Preclinical studies suggest body temperature (Tb) and consequently brain temperature has the potential to bidirectionally interact with tau pathology in Alzheimer's Disease (AD). Tau phosphorylation is substantially increased by a small (<1 °C) decrease in temperature within the human physiological range, and thermoregulatory nuclei are affected by tau pathology early in the AD continuum. In this study we evaluated whether Tb (as a proxy for brain temperature) is cross-sectionally associated with clinically utilized markers of tau pathology in cognitively normal older adults. METHODS: Tb was continuously measured with ingestible telemetry sensors for 48 h. This period included two nights of nocturnal polysomnography to delineate whether Tb during waking vs sleep is differentially associated with tau pathology. Tau phosphorylation was assessed with plasma and cerebrospinal fluid (CSF) tau phosphorylated at threonine 181 (P-tau), sampled the day following Tb measurement. In addition, neurofibrillary tangle (NFT) burden in early Braak stage regions was imaged with PET-MR using the [18F]MK-6240 radiotracer on average one month later. RESULTS: Lower Tb was associated with increased NFT burden, as well as increased plasma and CSF P-tau levels (p < 0.05). NFT burden was associated with lower Tb during waking (p < 0.05) but not during sleep intervals. Plasma and CSF P-tau levels were highly correlated with each other (p < 0.05), and both variables were correlated with tau tangle radiotracer uptake (p < 0.05). CONCLUSIONS: These results, the first available for human, suggest that lower Tb in older adults may be associated with increased tau pathology. Our findings add to the substantial preclinical literature associating lower body and brain temperature with tau hyperphosphorylation. CLINICAL TRIAL NUMBER: NCT03053908.


Assuntos
Doença de Alzheimer , Proteínas tau , Idoso , Doença de Alzheimer/patologia , Peptídeos beta-Amiloides/metabolismo , Biomarcadores/líquido cefalorraquidiano , Temperatura Corporal , Encéfalo/metabolismo , Humanos , Emaranhados Neurofibrilares/metabolismo , Tomografia por Emissão de Pósitrons , Proteínas tau/metabolismo
15.
Clin Imaging ; 83: 177-183, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35092926

RESUMO

OBJECTIVE: Texture features are proposed for classification and prognostication, with lacking information about variability. We assessed 3 T liver MRI feature variability. METHODS: Five volunteers underwent standard 3 T MRI, and repeated with identical and altered parameters. Two readers placed regions of interest using 3DSlicer. Repeatability (between standard and repeat scan), robustness (between standard and parameter changed scan), and reproducibility (two reader variation) were computed using coefficient of variation (CV). RESULTS: 67%, 49%, and 61% of features had good-to-excellent (CV ≤ 10%) repeatability on ADC, T1, and T2, respectively, least frequently for first order (19-35%). 22%, 19%, and 21% of features had good-to-excellent robustness on ADC, T1, and T2, respectively. 52%, 35%, and 25% of feature measurements had good-to-excellent inter-reader reproducibility on ADC, T1, and T2, respectively, with highest good-to-excellent reproducibility for first order features on ADC/T1. CONCLUSION: We demonstrated large variations in texture features on 3 T liver MRI. Further study should evaluate methods to reduce variability.


Assuntos
Fígado , Imageamento por Ressonância Magnética , Humanos , Fígado/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Reprodutibilidade dos Testes
16.
J Orthop Surg Res ; 17(1): 42, 2022 Jan 22.
Artigo em Inglês | MEDLINE | ID: mdl-35065660

RESUMO

BACKGROUND: Image-guided joint aspirations used to assist the diagnosis of periprosthetic joint infection (PJI) may commonly result in a dry tap-or insufficient fluid for culture and cell count analysis. Dry tap aspirations are painful and invasive for patients and often utilize a subsequent saline lavage to obtain a microbiology sample. Currently, there is a paucity of the literature addressing predictors that could suggest whether a dry tap will occur. The purpose of this study was to examine the effects of various factors on "dry tap" occurrence in patients with suspected PJI following total hip arthroplasty (THA). METHODS: A retrospective review was performed among THA patients suspected for PJI who received image-guided joint aspiration procedures at our institution from May 2016 to February 2020. The procedural factors included the imaging modality used for aspiration, anatomic approach, needle gauge size used, and the presence of a trainee. The patient-specific factors included number of prior ipsilateral hip surgeries, femoral head size, ESR/CRP values, and BMI. RESULTS: In total, 336 patients met our inclusion criteria. One hundred and twenty hip aspirations resulted in a dry tap (35.7%) where the patients underwent a saline lavage. Among the procedural and patient-specific factors, none of the factors were found to be statistically different between the two cohorts nor conferred any greater odds of a dry tap occurring. CONCLUSION: No associations with dry tap occurrence were found among the procedural and patient-specific factors studied. Further research is needed to identify additional factors that may be more predictive of dry taps.


Assuntos
Artroplastia de Quadril , Articulação do Quadril/cirurgia , Prótese de Quadril , Paracentese/métodos , Infecções Relacionadas à Prótese/etiologia , Artroplastia de Quadril/efeitos adversos , Articulação do Quadril/diagnóstico por imagem , Prótese de Quadril/efeitos adversos , Humanos , Estudos Retrospectivos , Solução Salina , Líquido Sinovial , Irrigação Terapêutica/métodos
17.
Acad Radiol ; 29 Suppl 2: S98-S107, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-33610452

RESUMO

OBJECTIVE: To evaluate the inter-observer consistency for subsolid pulmonary nodule radiomic features. MATERIALS AND METHODS: Subsolid nodules were selected by reviewing radiology reports of CT examinations performed December 1, 2015 to April 1, 2016. Patients with CTs at two time points were included in this study. There were 55 patients with subsolid nodules, of whom 14 had two nodules. Of 69 subsolid nodules, 66 were persistent at the second time point, yielding 135 lesions for segmentation. Two thoracic radiologists and an imaging fellow segmented the lesions using a semi-automated volumetry algorithm (Syngo.via Vb20, Siemens). Coefficient of variation (CV) was used to assess consistency of 91 quantitative measures extracted from the subsolid nodule segmentations, including first and higher order texture features. The accuracy of segmentation was visually graded by an experienced thoracic radiologist. Influencing factors on radiomic feature consistency and segmentation accuracy were assessed using generalized estimating equation analyses and the Exact Mann-Whitney test. RESULTS: Mean patient age was 71 (38-93 years), with 39 women and 16 men. Mean nodule volume was 1.39mL, range .03-48.2mL, for 135 nodules. Several radiomic features showed high inter-reader consistency (CV<5%), including entropy, uniformity, sphericity, and spherical disproportion. Descriptors such as surface area and energy had low consistency across inter-reader segmentations (CV>10%). Nodule percent solid component and attenuation influenced inter-reader variability of some radiomic features. The presence of contrast did not significantly affect the consistency of subsolid nodule radiomic features. Near perfect segmentation, within 5% of actual nodule size, was achieved in 68% of segmentations, and very good segmentation, within 25% of actual nodule size, in 94%. Morphologic features including nodule margin and shape (each p <0.01), and presence of air bronchograms (p = 0.004), bubble lucencies (p = 0.02) and broad pleural contact (p < 0.01) significantly affected the probability of near perfect segmentation. Stroke angle (p = 0.001) and length (p < 0.001) also significantly influenced probability of near perfect segmentation. CONCLUSIONS: The inter-observer consistency of radiomic features for subsolid pulmonary nodules varies, with high consistency for several features, including sphericity, spherical disproportion, and first and higher order entropy, and normalized non-uniformity. Nodule morphology influences the consistency of subsolid nodule radiomic features, and the accuracy of subsolid nodule segmentation.


Assuntos
Neoplasias Pulmonares , Nódulo Pulmonar Solitário , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Feminino , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/patologia , Masculino , Radiologistas , Nódulo Pulmonar Solitário/diagnóstico por imagem , Nódulo Pulmonar Solitário/patologia , Tomografia Computadorizada por Raios X/métodos
18.
Eur Radiol ; 32(2): 1308-1319, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34410458

RESUMO

OBJECTIVES: To assess whether MR fingerprinting (MRF)-based relaxation properties exhibit cross-sectional and prospective correlations with patient outcome and compare the results with those from DTI. METHODS: Clinical imaging, MRF, and DTI were acquired in patients (24 ± 10 days after injury (timepoint 1) and 90 ± 17 days after injury (timepoint 2)) and once in controls. Patient outcome was assessed with global functioning, symptom profile, and neuropsychological testing. ADC and fractional anisotropy (FA) from DTI and T1 and T2 from MRF were compared in 12 gray and white matter regions with Mann-Whitney tests. Bivariate associations between MR measures and outcome were assessed using the Spearman correlation and logistic regression. RESULTS: Data from 22 patients (38 ± 12 years; 17 women) and 18 controls (32 ± 8 years; 12 women) were analyzed. Fourteen patients (37 ± 12 years; 11 women) returned for timepoint 2, while two patients provided only timepoint 2 clinical outcome data. At timepoint 1, there were no differences between patients and controls in T1, T2, and ADC, while FA was lower in mTBI frontal white matter. T1 at timepoint 1 and the change in T1 exhibited more (n = 18) moderate to strong correlations (|r|= 0.6-0.85) with clinical outcome at timepoint 2 than T2 (n = 3), FA (n = 7), and ADC (n = 2). High T1 at timepoint 1, and serially increasing T1, accounted for five of the six MR measures with the highest utility for identification of non-recovered patients at timepoint 2 (AUC > 0.80). CONCLUSION: T1 derived from MRF was found to have higher utility than T2, FA, and ADC for predicting 3-month outcome after mTBI. KEY POINTS: • In a region-of-interest approach, FA, ADC, and T1 and T2 all showed limited utility in differentiating patients from controls at an average of 24 and 90 days post-mild traumatic brain injury. • T1 at 24 days, and the serial change in T1, revealed more and stronger predictive correlations with clinical outcome at 90 days than did T2, ADC, or FA. • T1 showed better prospective identification of non-recovered patients at 90 days than ADC, T2, and FA.


Assuntos
Concussão Encefálica , Encéfalo , Concussão Encefálica/diagnóstico por imagem , Estudos Transversais , Feminino , Humanos , Imageamento por Ressonância Magnética , Espectroscopia de Ressonância Magnética , Estudos Prospectivos
19.
J Am Coll Radiol ; 19(3): 407-414, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34896068

RESUMO

OBJECTIVE: To evaluate the impact of structured recommendations on follow-up completion for incidental lung nodules (ILNs). METHODS: Patients with ILNs before and after implementation of structured Fleischner recommendations and electronic tracking were sampled randomly. The cohorts were compared for imaging follow-up. Multivariable logistic regression was used to assess appropriate follow-up and loss to follow-up, with independent variables including use of structured recommendations or tracking, age, sex, race, ethnicity, setting of the index test (inpatient, outpatient, emergency department), smoking history, and nodule features. RESULTS: In all, 1,301 patients met final inclusion criteria, including 255 patients before and 1,046 patients after structured recommendations or tracking. Baseline differences were found in the pre- and postintervention groups, with smaller ILNs and younger age after implementing structured recommendations. Comparing pre- versus postintervention outcomes, 40.0% (100 of 250) versus 29.5% (309 of 1,046) of patients had no follow-up despite Fleischner indications for imaging (P = .002), and among the remaining patients, 56.6% (82 of 145) versus 75.0% (553 of 737) followed up on time (P < .001). Delayed follow-up was more frequent before intervention. Differences postintervention were mostly accounted for by nodules ≤8 mm in the outpatient setting (P < .001). In multivariable analysis, younger age, White race, outpatient setting, and larger nodule size showed significant association with appropriate follow-up completion (P < .015), but structured recommendations did not. Similar results applied for loss to follow-up. DISCUSSION: Consistent use of structured reporting is likely key to mitigate selection bias when benchmarking rates of appropriate follow-up of ILN. Emergency department patients and inpatients are at high risk of missed or delayed follow-up despite structured recommendations.


Assuntos
Neoplasias Pulmonares , Nódulo Pulmonar Solitário , Eletrônica , Humanos , Achados Incidentais , Pulmão , Neoplasias Pulmonares/diagnóstico por imagem , Nódulo Pulmonar Solitário/diagnóstico por imagem
20.
Ann Pediatr Cardiol ; 15(5-6): 459-466, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-37152504

RESUMO

Context: Cardiac injury has been described in both acute COVID-19 and the multisystem inflammatory syndrome in children (MIS-C). Echocardiographic strain has been shown to be a sensitive measure of systolic function. Aims: We sought to describe strain findings in both the groups on initial presentation and follow-up. Settings and Design: A retrospective study analyzing echocardiograms of all patients presenting with acute COVID-19 infection and MIS-C at our institution between March 2020 and December 2020 was performed. Subjects and Methods: TOMTEC software was used for strain analysis in both the study groups (COVID-19 and MIS-C) and age-matched healthy controls. Strain was correlated with LV ejection fraction (EF) and serum troponin levels. Results: Forty-five patients (34 - MIS-C and 11 - COVID-19) met the inclusion criteria. There was a statistically significant decrease in LV longitudinal strain (P < 0.001), LV circumferential strain (P < 0.001), and left atrial strain (P = 0.014) in the MIS-C group when compared to the control group. There was a statistically significant decrease in LV longitudinal strain (P = 0.028) in the acute COVID-19 group. All patients with abnormal left ventricular EF (LVEF) had abnormal strain. However, 14 (41%) patients in the MIS-C group and 3 (27%) in the acute COVID-19 group had preserved LVEF but abnormal strain. There was a significant correlation with LV longitudinal strain (P = 0.005) and LVEF (P = 0.002) and troponin in patients with MIS-C. Abnormal strain persisted in one-third of patients in the MIS-C and acute COVID-19 groups on outpatient follow-up. Conclusions: Patients with MIS-C and acute COVID-19 can develop myocardial dysfunction as seen by abnormal strain. LV longitudinal strain correlates with cardiac injury as measured by serum troponin in patients with MIS-C. Strain may provide an additional tool in detecting subtle myocardial dysfunction. It can be routinely employed at diagnosis and at follow-up evaluation of these patients.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...