1.
J Chromatogr A ; 1715: 464596, 2024 Jan 25.
Artigo em Inglês | MEDLINE | ID: mdl-38159406

RESUMO

The adsorption behaviour of caffeine and theophylline under hydrophilic interaction chromatography and purely aqueous conditions was investigated on four phosphodiester stationary phases. Solute adsorption isotherms were determined by frontal analysis or inverse method. The bi-Langmuir model was found to be the best choice to describe the behaviour of caffeine and theophylline adsorption in purely aqueous conditions, whereas the bi-Moreau model describes the adsorption phenomena in HILIC conditions. The results obtained demonstrate that the interaction of caffeine and theophylline with the stationary phase surface varies depending on the mobile phase composition. Both in pure aqueous mobile phase and in HILIC mode, the heterogeneity of the surface of the studied stationary phases is confirmed. In hydrophilic solutions, the sample molecules interact with the stationary phase only. In hydrophobic conditions, a lateral interaction occurs between caffeine or theophylline molecules, which are poorly soluble in acetonitrile-rich solvents. This confirms that the same compound on the same stationary phase can behave rather differently, depending on the mobile phase composition. Thus, the mobile phase may govern and control the retention mechanism.


Assuntos
Cafeína , Teofilina , Cromatografia Líquida/métodos , Água/química , Interações Hidrofóbicas e Hidrofílicas
2.
J Chromatogr A ; 1624: 461218, 2020 Aug 02.
Artigo em Inglês | MEDLINE | ID: mdl-32540066

RESUMO

In this study, amylose- and cellulose-phenylcarbamate-based chiral columns with different chiral-selector (CS) chemistries were compared to each other for the separation of enantiomers of basic chiral analytes in acetonitrile and aqueous-acetonitrile mobile phases in HPLC. For two chemistries the amylose-based columns with coated and immobilized CSs were also compared. The comparison of CSs containing only electron-donating or electron-withdrawing substituents with those containing both electron-donating and electron-withdrawing substituents showed opposite results for the studied set of chiral analytes in the case of amylose and cellulose derivatives. Along with the chemistry of CS the focus was on the behavior of polysaccharide phenylcarbamates in acetonitrile versus aqueous acetonitrile as eluents. In agreement with earlier results, it was found that in contrast to the commonly accepted view, polysaccharide phenylcarbamates do not behave as typical reversed-phase materials for basic analytes either. In the range of water content in the mobile phase of up to 20-30% v/v the behavior of these CSs is similar to hydrophilic interaction liquid chromatography (HILIC)-type adsorbents. This means that with increasing water content in the mobile phase up to 20-30% v/v, the retention of analytes mostly decreases. The important finding of this study is that the separation efficiency improves for most analytes when switching from pure acetonitrile to aqueous acetonitrile. Therefore, in spite of reduced retention, the separation of enantiomers improves and thus, the HILIC-range of mobile phase composition, offering shorter analysis time and better peak resolution, is advantageous over pure polar-organic solvent mode. Interesting examples of enantiomer elution order (EEO) reversal were observed for some analytes based on the content of water in the mobile phase on Lux Cellulose-1 and Lux Amylose-2 columns.


Assuntos
Amilose/química , Celulose/química , Cromatografia Líquida de Alta Pressão/métodos , Preparações Farmacêuticas/isolamento & purificação , Fenilcarbamatos/química , Acetonitrilas/química , Elétrons , Etanolaminas/análise , Etanolaminas/isolamento & purificação , Preparações Farmacêuticas/análise , Propanolaminas/análise , Propanolaminas/isolamento & purificação , Propranolol/análise , Propranolol/isolamento & purificação , Estereoisomerismo , Água/química
3.
Sci Rep ; 5: 14434, 2015 Sep 23.
Artigo em Inglês | MEDLINE | ID: mdl-26395526

RESUMO

Millions of people use mobile phones (MP) while drinking coffee or other caffeine containing beverages. Little is known about the potential combined effects of MP irradiation and caffeine on cognitive functions. Here we investigated whether caffeine intake and concurrent exposure to Universal Mobile Telecommunications System (UMTS) MP-like irradiation may interactively influence neuro-cognitive function in an active visual oddball paradigm. In a full factorial experimental design, 25 participants performed a simple visual target detection task while reaction time (RT) and electroencephalogram (EEG) was recorded. Target trials were divided into Low and High probability sets based on target-to-target distance. We analyzed single trial RT and alpha-band power (amplitude) in the pre-target interval. We found that RT was shorter in High vs. Low local probability trials, and caffeine further shortened RT in High probability trials relative to the baseline condition suggesting that caffeine improves the efficiency of implicit short-term memory. Caffeine also decreased pre-target alpha amplitude resulting in higher arousal level. Furthermore, pre-target gamma power positively correlated with RT, which may have facilitated target detection. However, in the present pharmacologically validated study UMTS exposure either alone or in combination with caffeine did not alter RT or pre-stimulus oscillatory brain activity.


Assuntos
Cafeína/farmacologia , Telefone Celular , Cognição/efeitos dos fármacos , Cognição/efeitos da radiação , Campos Eletromagnéticos/efeitos adversos , Adolescente , Adulto , Encéfalo/efeitos dos fármacos , Encéfalo/efeitos da radiação , Ondas Encefálicas/efeitos dos fármacos , Ondas Encefálicas/efeitos da radiação , Eletroencefalografia , Feminino , Humanos , Masculino , Memória de Curto Prazo/efeitos dos fármacos , Memória de Curto Prazo/efeitos da radiação , Tempo de Reação/efeitos dos fármacos , Tempo de Reação/efeitos da radiação , Adulto Jovem
4.
Acta Biol Hung ; 66(3): 304-15, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26344026

RESUMO

The family Solanaceae includes several melliferous plants, which tend to produce copious amounts of nectar. Floral nectar is a chemically complex aqueous solution, dominated by sugars, but minor components such as amino acids, proteins, flavonoids and alkaloids are present as well. This study aimed at analysing the protein and alkaloid profile of the nectar in seven solanaceous species. Proteins were examined with SDS-PAGE and alkaloids were analyzed with HPLC. The investigation of protein profile revealed significant differences in nectar-protein patterns not only between different plant genera, but also between the three Nicotiana species investigated. SDS-PAGE suggested the presence of several Nectarin proteins with antimicrobial activity in Nicotiana species. The nectar of all tobacco species contained the alkaloid nicotine, N. tabacum having the highest nicotine content. The nectar of Brugmansia suaveolens, Datura stramonium, Hyoscyamus niger and Lycium barbarum contained scopolamine, the highest content of which was measured in B. suaveolens. The alkaloid concentrations in the nectars of most solanaceous species investigated can cause deterrence in honeybees, and the nectar of N. rustica and N. tabacum can be considered toxic for honeybees.


Assuntos
Néctar de Plantas/química , Proteínas de Plantas/análise , Solanaceae/química , Alcaloides de Solanáceas/análise , Animais , Abelhas , Néctar de Plantas/metabolismo , Proteínas de Plantas/metabolismo , Solanaceae/metabolismo , Alcaloides de Solanáceas/metabolismo
5.
J Chromatogr A ; 1365: 156-63, 2014 Oct 24.
Artigo em Inglês | MEDLINE | ID: mdl-25262029

RESUMO

We investigate the impact of polydispersity of the sample molecules on the separation process and on the efficiency of size-exclusion chromatography. Polydispersity was integrated into the molecular (stochastic) model of chromatography; the characteristic function, the band profile and the most important moments of the elution profiles were calculated for several kind of pore structures. We investigated the parameters affected by polydispersity on the separation for a number of pore shapes. Our results demonstrate that even a small distribution in the molecular size (i.e. polydispersity) can contribute substantially to the total width of the chromatographic peak. The pure effect of polydispersity can only be investigated via mathematical modeling, because its contribution to an experimental chromatogram cannot be separated from other band-broadening effects.


Assuntos
Cromatografia em Gel/métodos , Modelos Teóricos , Método de Monte Carlo , Processos Estocásticos
6.
J Chromatogr A ; 1359: 112-6, 2014 Sep 12.
Artigo em Inglês | MEDLINE | ID: mdl-25085822

RESUMO

The mesopore structure (pore size and its distribution) for the first and second generations of silica-based monolithic columns was determined by inverse size-exclusion chromatography. The effect of pore size distribution was considered via the molecular theory of size-exclusion chromatography. The molecular theory of chromatography allows taking into account the kinetics of the pore ingress and egress processes, the heterogeneity of the pore sizes and polymer polydispersity. Besides, the mesopore structure, the characteristic domain sizes of the macropores present in the first and second generations of silica-based monolithic columns were also characterized.


Assuntos
Cromatografia em Gel/instrumentação , Cromatografia em Gel/métodos , Dióxido de Silício/química , Cinética , Polímeros/química , Porosidade
7.
Pharmacol Biochem Behav ; 124: 412-20, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25073015

RESUMO

BACKGROUND: Caffeine affects information processing by acting predominantly on cortical activation, arousal and attention. Millions consume caffeine and simultaneously use their mobile phone (MP) during everyday activities. However, it is not known whether and how MP-emitted electromagnetic fields (EMFs) can modulate known psychoactive effects of caffeine. Here we investigated behavioral and neural correlates of caffeine and simultaneous MP exposure in a third generation (3G) Universal Mobile Telecommunication System (UMTS) signal modulation scheme. METHODS: We recorded electroencephalography (EEG) and event related potentials (ERP) in an oddball paradigm to frequent standard (p=0.8) and rare target (p=0.2) stimuli in a placebo controlled, double blind, within-subject protocol in four experimental sessions: 1) no caffeine and no MP, 2) caffeine only, 3) MP only, and 4) caffeine and MP. The subjects' task was to discriminate between standard and target stimuli and respond to the latter by pressing a button while reaction time (RT) and EEG were recorded. To provide a complete analysis of any possible caffeine and/or MP treatment effects that may have occurred, we analyzed the P300 ERP wave using four different ERP measures: 1) peak latency, 2) peak amplitude, 3) 50% fractional area latency (FAL) and 4) area under the curve (AUC). RESULTS: Caffeine significantly shortened RT and decreased AUC of the P300 component compared to the control or the UMTS MP alone conditions. However, no effects were observed on RT or P300 in the UMTS MP exposure sessions, neither alone nor in combination with caffeine. CONCLUSION: Overall, the present results did not demonstrate any interactive or synergistic effects of caffeine and UMTS MP like EMF exposure on basic neural or cognitive measures. However, we found that caffeine consistently enhanced behavioral and ERP measures of visual target detection, showing that present results were obtained using a pharmacologically validated, consistent and replicable methodology.


Assuntos
Cafeína/administração & dosagem , Telefone Celular , Potenciais Evocados , Percepção Visual , Adolescente , Adulto , Método Duplo-Cego , Eletroencefalografia , Feminino , Humanos , Masculino , Placebos , Adulto Jovem
8.
J Chromatogr A ; 1339: 110-7, 2014 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-24666937

RESUMO

Stationary phases in liquid chromatography exhibit quite different pore structures. Whereas most of the fully porous packing materials possess a narrow pore size distribution, core-shell particles are usually of rather wide pore size distribution. Recently a novel theory of size exclusion chromatography was introduced to model the effect of pore size distribution. The molecular theory of chromatography allows taking into account the kinetics of the pore ingress and egress processes, the heterogeneity of the pore sizes and polymer polydispersity as well. The novel model was applied to inverse size exclusion chromatography data. In this study, we have determined the actual pore size distribution of a number of HPLC stationary phases. Our results agree well with the results obtained with the model introduced by Knox and Scott.


Assuntos
Cromatografia em Gel/métodos , Cromatografia Líquida de Alta Pressão/métodos , Cromatografia em Gel/instrumentação , Cromatografia em Gel/normas , Cromatografia Líquida de Alta Pressão/instrumentação , Cromatografia Líquida de Alta Pressão/normas , Cinética , Modelos Teóricos , Poliestirenos/química , Porosidade , Padrões de Referência , Processos Estocásticos
9.
J Chromatogr A ; 1331: 52-60, 2014 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-24485538

RESUMO

Chromatographic processes can conveniently be modeled at a microscopic level using the molecular theory of chromatography. This molecular or microscopic theory is completely general; therefore it can be used for any chromatographic process such as adsorption, partition, ion-exchange or size exclusion chromatography. The molecular theory of chromatography allows taking into account the kinetics of the pore ingress and egress processes, the heterogeneity of the pore sizes and polymer polydispersion. In this work, we assume that the pore size in the stationary phase of chromatographic columns is governed by a wide lognormal distribution. This property is integrated into the molecular model of size exclusion chromatography and the moments of the elution profiles were calculated for several kinds of pore structure. Our results demonstrate that wide pore size distributions have strong influence on the retention properties (retention time, peak width, and peak shape) of macromolecules. The novel model allows us to estimate the real pore size distribution of commonly used HPLC stationary phases, and the effect of this distribution on the size exclusion process.


Assuntos
Cromatografia em Gel/métodos , Modelos Teóricos , Adsorção , Cromatografia Líquida de Alta Pressão/métodos , Cinética , Polímeros/química , Porosidade , Processos Estocásticos
10.
Anal Bioanal Chem ; 397(3): 1307-14, 2010 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-20300736

RESUMO

The characterization of mass-transfer processes in a chromatographic column during a separation process is essential, since the influence of the mass-transfer kinetics on the shape of the chromatographic band profiles and on the efficiency of the separation is crucial. Several sources of mass transfer in a chromatographic bed have been identified and studied: the axial dispersion in the stream of mobile phase, the external mass-transfer resistance, intraparticle diffusion, and the kinetics of adsorption-desorption. We measured and compared the characteristics and performance of a new brand of shell particles and those of a conventional brand of totally porous silica particles. The shell stationary phase was made of 2.7-microm superficially porous particles (a 1.7-microm solid core is covered with a 0.5-microm-thick shell of porous silica). The other material consisted of totally porous particles of conventional 3.5-microm commercial silica. We measured the first and second central moments of the peaks of human insulin over a wide range of mobile phase velocities (from 0.02 to 1.3 mL/min) at 20 degrees C. The plate height equations were constructed and the axial dispersion, external mass transfer, as well as the intraparticle diffusion coefficients were calculated for the two stationary phases.


Assuntos
Cromatografia Líquida/métodos , Insulina/isolamento & purificação , Adsorção , Difusão , Humanos , Cinética , Porosidade , Processos Estocásticos
11.
J Chromatogr A ; 1216(8): 1253-62, 2009 Feb 20.
Artigo em Inglês | MEDLINE | ID: mdl-19081569

RESUMO

For the correct description of a chromatographic process, the determination of mass-transfer kinetics in the column is required because the influence of the mass-transfer kinetics on the shape of chromatographic band profiles is crucial. Several sources of mass transfer in a chromatographic bed have been identified and studied: the axial dispersion in the stream of mobile phase, the external mass-transfer resistance, intraparticle diffusion, and the kinetics of adsorption-desorption In this study we compare mass-transfer coefficients obtained in a reversed phase chromatographic column using macroscopic and microscopic approaches. The general rate model, the plate height equation, moment analysis, and stochastic analysis were used to assess chromatographic process during the separation of alkylbenzenes.


Assuntos
Cromatografia Líquida/métodos , Modelos Teóricos , Espectrofotometria Ultravioleta , Processos Estocásticos
12.
Electrophoresis ; 27(23): 4682-7, 2006 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-17136716

RESUMO

Artificial antibodies in the form of gel granules were synthesized from the monomers acrylamide and N,N'-methylenebisacrylamide by the imprinting method in the presence of Echerichia coli bacteria as template. The electrophoretic migration velocities of the gel antibodies (i) saturated with the antigen (Escherichia coli MRE-600), (ii) freed of the antigen, and (iii) resaturated with bacteria, were determinated by electrophoresis in a rotating narrow-bore tube of 245 mm length and the 2.5 and 9.6 mm inner and outer diameters, respectively. Removal of bacteria from the gel antibodies was made by treatment with enzymes, followed by washing with SDS and buffer. Gel granules becoming charged by adsorption of bacteria move in an electrical field. We obtained a significant selectivity of gel antibodies for E. coli MRE-600, since the granules did not interact with Lactococcus lactis; and when E. coli BL21 bacteria were added to the gels selective for E. coli MRE-600, a significant difference in the migration rate of the complexes formed with the two strains was observed indicating the ability of differentiation between the two strains. The gel antibodies can be used repeatedly. The new imprinting method for the synthesis of artificial gel antibodies against bioparticles described herein, and the classical electrophoretic analysis technique employed, thus represent - when combined - a new approach to distinguish between different types and strains of bacteria. The application area can certainly be extended to cover other classes of cells.


Assuntos
Acrilamida/química , Acrilamidas/química , Anticorpos Antibacterianos/química , Anticorpos Antibacterianos/isolamento & purificação , Eletroforese/métodos , Antígenos de Bactérias/química , Antígenos de Bactérias/imunologia , Soluções Tampão , Escherichia coli/química , Escherichia coli/imunologia , Géis/química , Estrutura Molecular , Proteínas/química , Vírus/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...