1.
Microchem J ; 177: 107276, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35169329

RESUMO

Daclatasvir dihydrochloride (DAC) is an anti-hepatitis C virus (HCV) drug that has recently proven to be a promising candidate for the treatment of SARS-CoV-2. Still, there is a lack of sensitive potentiometric methods for its determination. In this work, carbon paste sensors based on dibenzo-18-crown-6 (DB18C6) were fabricated and optimized for the sensitive and selective potentiometric determination of DAC in Daclavirocyrl® tablets, serum, and urine samples. The best performance was obtained by two sensors referred to as sensor I and sensor II. Both sensors exhibited a wide linear response range of 5×10-9 - 1×10-3 mol/L, and Nernstian slopes of 29.8 ± 1.18 and 29.5 ± 1.00 mV/decade, with limits of detection, 4.8×10-9 and 3.2×10-9 mol/L, for the sensors I and II, respectively. Sensors I and II displayed fast response times of 5-8 and 5-6 s, respectively, with great reversibility and no memory effect. Moreover, the sensors exhibited a lifetime of 16 days. For the study of sensors morphology and elucidation of the interaction mechanism, the scanning electron microscope (SEM), Fourier-transform infrared spectroscopy (FTIR), and nuclear magnetic resonance (1H NMR) techniques were performed. A selectivity study was performed, and the proposed sensors exhibited good discrimination between DAC and potentially coexisting interferents with sensor II displaying better selectivity. Finally, sensor II was successfully applied for the determination of DAC in the above-mentioned samples, with recovery values ranging from 99.25 to 101.42%, and relative standard deviation (RSD) values ranging from 0.79 to 1.53% which reflected the high accuracy and precision.

2.
Ann Chim ; 97(3-4): 213-25, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17822229

RESUMO

Novel PVC membrane electrodes for the determination of betaine ion based on the formation of betaine-tetraphenylborate (Be-TPB) and betaine-phosphotungstate (Be-PT) ion-exchangers as electroactive materials are described. The sensors show a fast, stable, near Nernstian response for 6.92 x 10(-6) to 7.94 x 10(-3) M and 1.0 x 10(-4) to 1.0 x 10(-2) M betaine hydrochloride (Be.Cl) in case of Be-TPB electrode applying batch and flow injection analysis (FIA), respectively, and 2.95 x 10(-5) to 2.26 x 10(-3) M and 3.16 x 10(-5) to 1.0 x 10(-2) M in case of Be-PT electrode for batch and FIA electrodes, respectively, at 25 degrees C over the pH range of 3.5-10 with a cationic slope of 60.2 and 59.1 mV decade(-1) and a fast potential response of < or =15 s. The lower detection limits are 7.94 x 10(-6) and 3.18 x 10(-5) M Be.Cl for Be-TPB and Be-PT electrodes, respectively. Selectivity coefficient data for some common inorganic cations, sugars, amino acids and the components other than betaine, of the mixed drug investigated show negligible interference. The electrodes have been applied to the direct potentiometric determination of betaine hydrochloride in water and in a pharmaceutical preparation under batch and FIA conditions. Potentiometric titrations of Be.Cl with NaTPB and PTA as titrants were monitored with the developed betaine electrodes as an end point indicator electrode. The determination of Be.Cl shows an average recovery of 100.8% with mean relative standard deviation of 0.61%. The effect of temperature on the electrodes was also studied.


Assuntos
Betaína/análise , Potenciometria/métodos , Eletrodos , Concentração de Íons de Hidrogênio , Troca Iônica , Cloreto de Polivinila , Potenciometria/normas , Soluções , Temperatura , Titulometria
3.
Anal Sci ; 21(12): 1443-8, 2005 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-16379383

RESUMO

New ranitidine hydrochloride (RaCl)-selective electrodes of the conventional polymer membrane type are described. They are based on incorporation of ranitidine-tetraphenylborate (Ra-TPB) ion-pair or ranitidine-phosphotungstate (RaPT) ion-associate in a poly(vinyl chloride) (PVC) membrane plasticized with dioctylphthalate (DOP) or dibutylphthalate (DBP). The electrodes are fully characterized in terms of the membrane composition, solution temperature, and pH. The sensors showed fast and stable responses. Nernstian response was found over the concentration range of 2.0 x 10(-5) M to 1.0 x 10(-2) M and 1.0 x 10(-5) M to 1.0 x 10(-2) M in the case of Ra-TPB electrode and over the range of 1.03 x 10(-5) M to 1.00 x 10(-2) M and 1.0 x 10(-5) M to 1.0 x 10(-2) M in the case of Ra-PT electrode for batch and FIA systems, respectively. The electrodes exhibit good selectivity for RaCl with respect to a large number of common ions, sugars, amino acids, and components other than ranitidine hydrochloride of the investigated mixed drugs. The electrodes have been applied to the potentiometric determination of RaCl in pure solutions and in pharmaceutical preparations under batch and flow injection conditions with a lower detection limit of 1.26 x 10(-5) M and 5.62 x 10(-6) M at 25 +/- 1 degrees C. An average recovery of 100.91% and 100.42% with a relative standard deviation of 0.72% and 0.53% has been achieved.

4.
J Pharm Biomed Anal ; 39(1-2): 117-24, 2005 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-15935604

RESUMO

New PVC membrane electrodes selective for the determination of hyoscyamine ion (Hy(+)) based on hyoscyamine tetraphenylborate (Hy-TPB) or hyoscyamine phosphotungstate (Hy-PT) ion-exchangers as electroactive materials are described. The electrodes show a linear response for Hy(+) over the concentration range of 1.00 x 10(-5) to 1.26 x 10(-2) mol L(-1) and 1.00 x 10(-4) to 1.00 x 10(-2) mol L(-1) in case of Hy-TPB electrode applying batch and flow injection analysis (FIA), respectively, and 1.00 x 10(-5) to 4.52 x 10(-3) mol L(-1) and 6.31 x 10(-5) to 1.00 x 10(-2) mol L(-1) in case of Hy-PT electrode for batch and FIA, respectively. The lower detection limits are 3.90 x 10(-6) and 4.51 x 10(-6) at 25 degrees C for Hy-TPB and Hy-PT electrodes, respectively. The electrodes posses near Nernstian slopes of 56.5 and 57.8 mV/decade for Hy-TPB and Hy-PT electrodes, respectively, and a fast potential response of < or =20 s which is almost constant over a pH range of 3-10. Selectivity coefficient data for some common inorganic cations, sugars, amino acids and the components, other than hyoscyamine, of the mixed drugs investigated show negligible interference. The electrodes have been applied to the potentiometric determination of hyoscyamine in pure solution and in pharmaceutical preparations under batch and FIA conditions and as end point indicator electrode for the determination of hyoscyanine using potentiometric titration. For the concentrations (1.08 x 10(-5) mol L(-1) to 3.16 x 10(-3) mol L(-1)) an average recovery of 99.95% with relative standard deviation of 0.63% has been achieved. The effect of temperature on the electrodes was also studied.


Assuntos
Atropina/análise , Eletrodos , Preparações Farmacêuticas/química , Cloreto de Polivinila/química , Análise de Injeção de Fluxo , Concentração de Íons de Hidrogênio , Íons , Membranas Artificiais , Sensibilidade e Especificidade , Soluções