Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 36
Filtrar
1.
Front Neurol ; 15: 1325527, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38803648

RESUMO

Background: The primary objective is to evaluate the safety and effectiveness of Stryker second generation Target® Nano Coils in the treatment of ruptured and unruptured small (<7 mm) intracranial aneurysms. Methods: The TARGET Registry is a prospective, two-arm study with independent medical event monitoring and core-lab adjudication. This paper describes the second arm of the TARGET registry. Patients with de novo intracranial aneurysms were embolized with 2nd generation TARGET Nano coils in 12 US centers. The primary efficacy outcome was adequate aneurysm occlusion (RR occlusion grade I-II) on follow-up. Primary safety outcome was treatment-related morbidity and mortality. Secondary outcomes included aneurysm packing density immediately post-procedure, immediate adequate occlusion, aneurysm re-access rate, retreatment rate and clinical outcomes using modified ranking scale. A secondary analysis investigated the influence of using Nano-predominant coils (≥2/3 of total coil-length) vs. non-Nano-predominant coils (<2/3 of total length). Results: 150 patients with 155 aneurysms met the inclusion and exclusion criteria. (31%) patients with ruptured and (69%) with unruptured aneurysms were treated using TARGET coils. Median age was 58.8 (SD 12.7), 74.7% were females, and 80% were Caucasians. Mean follow-up was 5.23 (SD 2.27) months. Peri-procedural mortality was seen in 2.0% of patients. Good outcome at discharge (mRS 0-2) was seen in 81.3% of the cohort. The median packing density (SD) was 29.4% (14.9). Mid-term complete/near complete occlusion rate was seen in 96% of aneurysms and complete obliteration was seen in 75.2% of aneurysms. Patients treated predominantly with Nano coils had higher PD (32.6% vs. 26.1%, p < 0.001). There was no significant difference in clinical and angiographic outcomes. The mid-term mRS0-2 was achieved in 106/109 (97.2%) patients. All-cause mortality was 5/115 (4.3%). Conclusion: In the multicenter TARGET Registry, 75.8% of aneurysms achieved mid-term complete occlusion, and 96% achieved complete/near complete occlusion with excellent independent functional outcome.

2.
J Neurointerv Surg ; 2023 Dec 02.
Artigo em Inglês | MEDLINE | ID: mdl-38050090

RESUMO

BACKGROUND: Challenges to revascularization of large vessel occlusions (LVOs) persist. Current stent retrievers have limited effectiveness for removing organized thrombi. The NeVa device is a novel stent retriever designed to capture organized thrombi within the scaffold during retrieval. OBJECTIVE: To evaluate the safety and effectiveness of revascularization of acute LVOs with the NeVa device. METHODS: Prospective, international, multicenter, single-arm, Investigational Device Exemption study to evaluate the performance of the NeVa device in recanalizing LVOs including internal carotid artery, M1/M2 middle cerebral artery, and vertebrobasilar arteries, within 8 hours of onset. Primary endpoint was rate of expanded Treatment in Cerebral Ischemia (eTICI) score 2b-3 within 3 NeVa passes, tested for non-inferiority against a performance goal of 72% with a -10% margin. Additional endpoints included first pass success and 90-day modified Rankin Scale (mRS) score 0-2. Primary composite safety endpoint was 90-day mortality and/or 24-hour symptomatic intracranial hemorrhage (sICH). RESULTS: From April 2021 to April 2022, 139 subjects were enrolled at 25 centers. Median National Institutes of Health Stroke Scale (NIHSS) score was 16 (IQR 12-20). In the primary analysis population (n=107), eTICI 2b-3 within 3 NeVa passes occurred in 90.7% (97/107; non-inferiority P<0.0001; post hoc superiority P<0.0001). First pass eTICI 2b-3 was observed in 73.8% (79/107), with first pass eTICI 2b67-3 in 69.2% (74/107) and eTICI 2c-3 in 48.6% (52/107). Median number of passes was 1 (IQR 1-2). Final eTICI 2b-3 rate was 99.1% (106/107); final eTICI 2b67-3 rate was 91.6% (98/107); final eTICI 2c-3 rate was 72.9% (78/107). Good outcome (90-day mRS score 0-2) was seen in 65.1% (69/106). Mortality was 9.4% (13/138) with sICH in 5.0% (7/139). CONCLUSIONS: The NeVa device is highly effective and safe for revascularization of LVO strokes and demonstrates superior first pass success compared with a predicate performance goal. TRIAL REGISTRATION NUMBER: NCT04514562.

3.
J Neurointerv Surg ; 2023 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-37527927

RESUMO

BACKGROUND: Intrasaccular flow-disrupting devices are a safe and effective treatment strategy for intracranial aneurysms. We utilized high-frequency optical coherence tomography (HF-OCT) and digital subtraction angiography (DSA) to evaluate SEAL Arc, a new intrasaccular device, and compare the findings with the well-established Woven EndoBridge (WEB) device in an animal model of saccular aneurysms. METHODS: In a rabbit model, elastase-induced aneurysms were treated with SEAL Arc (n=11) devices. HF-OCT and DSA were performed after implant and repeated after 12 weeks. Device protrusion and malapposition were assessed at implant time and scored on a binary system. Aneurysm occlusion was assessed at 12 weeks with the WEB Occlusion Scale and dichotomized to complete (A and B) or incomplete (C and D) occlusion. The percentage of neointimal coverage after 12 weeks was quantified using HF-OCT. We compared these data to previously published historical controls treated with the gold-standard WEB device (n=24) in the same model. RESULTS: Aneurysm size and device placement were not significantly different between the two groups. Complete occlusion was demonstrated in 80% of the SEAL Arc devices, which compared favorably to the 21% of the aneurysms treated with WEB devices (P=0.002). Neointimal coverage across SEAL Arc devices was 86±15% compared with 49±27% for WEB (P=0.001). Protruding devices had significantly less neointimal coverage (P<0.001) as did incompletely occluded aneurysms (P<0.001). Histologically, all aneurysms treated with SEAL Arc devices were completely healed. CONCLUSION: Complete early aneurysm occlusion was frequently observed in the SEAL Arc treated aneurysms, with significant neointimal coverage after 12 weeks.

4.
Interv Neuroradiol ; 29(4): 481-487, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37455501

RESUMO

Intrasaccular flow disruption is a viable alternative to other endovascular treatments for saccular or wide-necked bifurcation intracranial aneurysms; however, wide neck aneurysms with irregular shapes or shallow depth may not be amenable to treatment currently available intrasaccular devices. Here, we present the first ever case report of the novel Saccular Endovascular Aneurysm Lattice Embolization System (SEAL™). The versatile utility of the SEAL™ device is demonstrated in a patient with acute subarachnoid hemorrhage (SAH) from a ruptured, complex, left middle cerebral artery (MCA) trilobed shallow wide-necked bifurcation aneurysm. Deployment and implantation of the SEAL device were technically feasible, safe, and conformed well to the irregular shape of the complex, ruptured aneurysm. Immediate total aneurysm occlusion was observed after implantation. Importantly, 1-year angiographic follow-up demonstrated durable, complete occlusion with no safety concerns. The SEAL device is a promising new novel technology which has the potential to treat very shallow aneurysms with limited height and irregular, multilobulated aneurysms.


Assuntos
Aneurisma Roto , Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Embolização Terapêutica , Procedimentos Endovasculares , Aneurisma Intracraniano , Humanos , Aneurisma Intracraniano/terapia , Aneurisma Intracraniano/cirurgia , Seguimentos , Resultado do Tratamento , Aneurisma da Aorta Abdominal/cirurgia , Estudos Retrospectivos , Procedimentos Endovasculares/métodos , Aneurisma Roto/terapia , Aneurisma Roto/cirurgia , Embolização Terapêutica/métodos , Angiografia Cerebral
5.
Front Neurol ; 10: 737, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31338061

RESUMO

Background and Purpose: To describe the final results of the TARGET Registry, a multicenter, real-world study of patients with intracranial aneurysms treated with new generation TARGET Coils. Methods: The TARGET Registry is a prospective, single-arm study with independent medical event monitoring and core-lab adjudication. Patients with de novo intracranial aneurysms were embolized with either TARGET-360° or helical coils in 12 US centers. The primary outcome was aneurysm packing density (PD), which was assessed immediately post-procedure. The secondary outcomes were immediate and long-term aneurysm occlusion rate using the Raymond Scale, and independent functional outcome using the modified Rankin Scale (mRS). A secondary analysis investigated the influence of the use of 100% 360-complex coils on clinical and angiographic outcomes. Results: 148 patients with 157 aneurysms met the inclusion and exclusion criteria. 58 (39.2%) patients with ruptured and 90 (61.8%) with unruptured aneurysms were treated using TARGET 360°, helical Coils, or both. Median age was 58.3 (IQR 48.1-67.4), 73% female, and 71.6% were Caucasian. Median follow-up time was 5.9 (IQR 4.0-6.9) months. The majority were treated with TARGET 360-coils (63.7%), followed by mixed and helical coils only. Peri-procedural morbidity and mortality was seen in 2.7% of patients. A good outcome at discharge (mRS 0-2) was seen in 89.9% of the full cohort, and in 84.5 and 93.3% in the ruptured and unruptured patients, respectively. The median packing density was 28.8% (IQR 20.3-41.1). Long-term complete and near complete occlusion rate was seen in 90.4% of aneurysms and complete obliteration was seen in 66.2% of the aneurysms. No significant difference in clinical and angiographic outcomes were noted between the pure 360-complex coiling vs. mixed 360-complex/Helical coiling strategies. In a multivariate analysis, predictors for long-term aneurysm occlusion were aneurysm location, immediate occlusion grade, and aneurysm size. The long-term independent functional outcome was achieved in 128/135 (94.8%) patients and all-cause mortality was seen in 3/148 (2%) patients. Conclusion: In the multicenter TARGET Registry, two-thirds of aneurysms achieved long-term complete occlusion and 91.0% achieved complete or near complete occlusion with excellent independent functional outcome. Clinical Trial Registration: www.ClinicalTrials.gov, identifier: NCT01748903.

6.
Stroke ; 50(4): 1003-1006, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30791829

RESUMO

Background and Purpose- Mechanical thrombectomy (MT) devices have led to improved reperfusion and clinical outcomes in acute ischemic stroke patients with emergent large vessel occlusions; however, less than one-third of patients achieve complete reperfusion. Use of intraarterial thrombolysis in the context of MT may provide an opportunity to enhance these results. Here, we evaluate the use of intraarterial rtPA (recombinant tissue-type plasminogen activator) as rescue therapy (RT) after failed MT in the North American Solitaire Stent-Retriever Acute Stroke registry. Methods- The North American Solitaire Stent-Retriever Acute Stroke registry recruited sites within North America to submit data on acute ischemic stroke patients treated with the Solitaire device. After restricting the population of 354 patients to use of RT and anterior emergent large vessel occlusions, we compared patients who were treated with and without intraarterial rtPA after failed MT. Results- A total of 37 and 44 patients was in the intraarterial rtPA RT and the no intraarterial rtPA RT groups, respectively. Revascularization success (modified Thrombolysis in Cerebral Infarction ≥2b) was achieved in more intraarterial rtPA RT patients (61.2% versus 46.6%; P=0.13) with faster times to recanalization (100±85 versus 164±235 minutes; P=0.36) but was not statistically significant. The rate of symptomatic intracranial hemorrhage (13.9% versus 6.8%; P=0.29) and mortality (42.9% versus 44.7%; P=0.87) were similar between the groups. Good functional outcome (modified Rankin Scale score of ≤2) was numerically higher in intraarterial rtPA patients (22.9% versus 18.4%; P=0.64). Further restriction of the RT population to M1 occlusions only and time of onset to groin puncture ≤8 hours, resulted in significantly higher successful revascularization rates in the intraarterial rtPA RT cohort (77.8% versus 38.9%; P=0.02). Conclusions- Intraarterial rtPA as RT demonstrated a similar safety and clinical outcome profile, with higher reperfusion rates achieved in patients with M1 occlusions. Prospective studies are needed to delineate the role of intraarterial thrombolysis in MT.


Assuntos
Isquemia Encefálica/tratamento farmacológico , Fibrinolíticos/uso terapêutico , Acidente Vascular Cerebral/tratamento farmacológico , Terapia Trombolítica/métodos , Ativador de Plasminogênio Tecidual/uso terapêutico , Isquemia Encefálica/cirurgia , Humanos , Estudos Prospectivos , Sistema de Registros , Acidente Vascular Cerebral/cirurgia , Trombectomia , Ativador de Plasminogênio Tecidual/administração & dosagem , Resultado do Tratamento
7.
Stroke ; 50(3): 697-704, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30776994

RESUMO

Background and Purpose- Mechanical thrombectomy has been shown to improve clinical outcomes in patients with acute ischemic stroke. However, the impact of balloon guide catheter (BGC) use is not well established. Methods- STRATIS (Systematic Evaluation of Patients Treated With Neurothrombectomy Devices for Acute Ischemic Stroke) was a prospective, multicenter study of patients with large vessel occlusion treated with the Solitaire stent retriever as first-line therapy. In this study, an independent core laboratory, blinded to the clinical outcomes, reviewed all procedures and angiographic data to classify procedural technique, target clot location, recanalization after each pass, and determine the number of stent retriever passes. The primary clinical end point was functional independence (modified Rankin Scale, 0-2) at 3 months as determined on-site, and the angiographic end point was first-pass effect (FPE) success rate from a single device attempt (modified Thrombolysis in Cerebral Infarction, ≥2c) as determined by a core laboratory. Achieving modified FPE (modified Thrombolysis in Cerebral Infarction, ≥2b) was also assessed. Comparisons of clinical outcomes were made between groups and adjusted for baseline and procedural characteristics. All participating centers received institutional review board approval from their respective institutions. Results- Adjunctive technique groups included BGC (n=445), distal access catheter (n=238), and conventional guide catheter (n=62). The BGC group had a higher rate of FPE following first pass (212/443 [48%]) versus conventional guide catheter (16/62 [26%]; P=0.001) and distal access catheter (83/235 [35%]; P=0.002). Similarly, the BGC group had a higher rate of modified FPE (294/443 [66%]) versus conventional guide catheter (26/62 [42%]; P<0.001) and distal access catheter (129/234 [55%]; P=0.003). The BGC group achieved the highest rate of functional independence (253/415 [61%]) versus conventional guide catheter (23/55 [42%]; P=0.007) and distal access catheter (113/218 [52%]; P=0.027). Final revascularization and mortality rates did not differ across the groups. Conclusions- BGC use was an independent predictor of FPE, modified FPE, and functional independence, suggesting that its routine use may improve the rates of early revascularization success and good clinical outcomes. Clinical Trial Registration- URL: https://www.clinicaltrials.gov . Unique identifier: NCT02239640.


Assuntos
Cateterismo/métodos , Acidente Vascular Cerebral/diagnóstico por imagem , Acidente Vascular Cerebral/cirurgia , Trombectomia/estatística & dados numéricos , Idoso , Idoso de 80 Anos ou mais , Isquemia Encefálica/diagnóstico por imagem , Isquemia Encefálica/terapia , Angiografia Cerebral , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Sistema de Registros , Stents , Resultado do Tratamento
8.
J Neurointerv Surg ; 10(Suppl 1): i45-i49, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30037956

RESUMO

BACKGROUND: Limited post-marketing data exist on the use of the Solitaire FR device in clinical practice. The North American Solitaire Stent Retriever Acute Stroke (NASA) registry aimed to assess the real world performance of the Solitaire FR device in contrast with the results from the SWIFT (Solitaire with the Intention for Thrombectomy) and TREVO 2 (Trevo versus Merci retrievers for thrombectomy revascularization of large vessel occlusions in acute ischemic stroke) trials. METHODS: The investigator initiated NASA registry recruited North American sites to submit retrospective angiographic and clinical outcome data on consecutive acute ischemic stroke (AIS) patients treated with the Solitaire FR between March 2012 and February 2013. The primary outcome was a Thrombolysis in Myocardial Ischemia (TIMI) score of ≥2 or a Treatment in Cerebral Infarction (TICI) score of ≥2a. Secondary outcomes were 90 day modified Rankin Scale (mRS) score, mortality, and symptomatic intracranial hemorrhage. RESULTS: 354 patients underwent treatment for AIS using the Solitaire FR device in 24 centers. Mean time from onset to groin puncture was 363.4±239 min, mean fluoroscopy time was 32.9±25.7 min, and mean procedure time was 100.9±57.8 min. Recanalization outcome: TIMI ≥2 rate of 83.3% (315/354) and TICI ≥2a rate of 87.5% (310/354) compared with the operator reported TIMI ≥2 rate of 83% in SWIFT and TICI ≥2a rate of 85% in TREVO 2. Clinical outcome: 42% (132/315) of NASA patients demonstrated a 90 day mRS ≤2 compared with 37% (SWIFT) and 40% (TREVO 2). 90 day mortality was 30.2% (95/315) versus 17.2% (SWIFT) and 29% (TREVO 2). CONCLUSIONS: The NASA registry demonstrated that the Solitaire FR device performance in clinical practice is comparable with the SWIFT and TREVO 2 trial results.


Assuntos
Isquemia Encefálica/cirurgia , Vigilância de Produtos Comercializados/tendências , Sistema de Registros , Stents/tendências , Acidente Vascular Cerebral/cirurgia , Trombectomia/tendências , Idoso , Idoso de 80 Anos ou mais , Isquemia Encefálica/epidemiologia , Estudos de Coortes , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , América do Norte/epidemiologia , Vigilância de Produtos Comercializados/métodos , Estudos Retrospectivos , Acidente Vascular Cerebral/epidemiologia , Trombectomia/métodos , Resultado do Tratamento , Estados Unidos/epidemiologia
9.
Interv Neurol ; 7(1-2): 26-35, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29628942

RESUMO

BACKGROUND: Various techniques are used to enhance the results of mechanical thrombectomy with stent-retrievers, including proximal arrest with balloon guide catheter (BGC), conventional large bore proximal catheter (CGC), or in combination with local aspiration through a large-bore catheter positioned at the clot interface (Aspiration-Retriever Technique for Stroke [ARTS]). We evaluated the impact of ARTS in the North American Solitaire Acute Stroke (NASA) registry. SUMMARY: Data on the use of the aspiration technique were available for 285 anterior circulation patients, of which 29 underwent ARTS technique, 131 CGC, and 125 BGC. Baseline demographics were comparable, except that ARTS patients are less likely to have hypertension or atrial fibrillation. The ARTS group had more ICA occlusions (41.4 vs. 22% in the BGC, p = 0.04 and 26% in CGC, p = 0.1) and less MCA/M1 occlusions (44.8 vs. 68% in BGC and 62% in CGC). Time from arterial puncture to reperfusion or end of procedure with ARTS was shorter than with CGC (54 vs. 91 min, p = 0.001) and was comparable to the BGC time (54 vs. 67, p = 0.11). Final degree of reperfusion was comparable among the groups (TICI [modified Thrombolysis in Cerebral Infarction] score 2b or higher was 72 vs. 70% for CGC vs. 78% for BGC). Procedural complications, mortality, and good clinical outcome at 90 days were similar between the groups. KEY MESSAGES: The ARTS mechanical thrombectomy in acute ischemic stroke patients appears to yield better results as compared to the use of CGCs with no significant difference when compared to BGC. This early ARTS technique NASA registry data are limited by the earlier generation distal large bore catheters and small sample size. Future studies should focus on the comparison of ARTS and BGC techniques.

10.
Stroke ; 49(3): 660-666, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-29459390

RESUMO

BACKGROUND AND PURPOSE: In acute ischemic stroke, fast and complete recanalization of the occluded vessel is associated with improved outcomes. We describe a novel measure for newer generation devices: the first pass effect (FPE). FPE is defined as achieving a complete recanalization with a single thrombectomy device pass. METHODS: The North American Solitaire Acute Stroke Registry database was used to identify a FPE subgroup. Their baseline features and clinical outcomes were compared with non-FPE patients. Clinical outcome measures included 90-days modified Rankin Scale score, National Institutes of Health Stroke Scale score, mortality, and symptomatic intracranial hemorrhage. Multivariate analyses were performed to determine whether FPE independently resulted in improved outcomes and to identify predictors of FPE. RESULTS: A total of 354 acute ischemic stroke patients underwent thrombectomy in the North American Solitaire Acute Stroke registry. FPE was achieved in 89 out of 354 (25.1%). More middle cerebral artery occlusions (64% versus 52.5%) and fewer internal carotid artery occlusions (10.1% versus 27.7%) were present in the FPE group. Balloon guide catheters were used more frequently with FPE (64.0% versus 34.7%). Median time to revascularization was significantly faster in the FPE group (median 34 versus 60 minutes; P=0.0003). FPE was an independent predictor of good clinical outcome (modified Rankin Scale score ≤2 was seen in 61.3% in FPE versus 35.3% in non-FPE cohort; P=0.013; odds ratio, 1.7; 95% confidence interval, 1.1-2.7). The independent predictors of achieving FPE were use of balloon guide catheters and non-internal carotid artery terminus occlusion. CONCLUSIONS: The achievement of complete revascularization from a single Solitaire thrombectomy device pass (FPE) is associated with significantly higher rates of good clinical outcome. The FPE is more frequently associated with the use of balloon guide catheters and less likely to be achieved with internal carotid artery terminus occlusion.


Assuntos
Isquemia Encefálica , Hemorragias Intracranianas , Sistema de Registros , Acidente Vascular Cerebral , Trombectomia , Idoso , Idoso de 80 Anos ou mais , Isquemia Encefálica/mortalidade , Isquemia Encefálica/cirurgia , Feminino , Humanos , Hemorragias Intracranianas/mortalidade , Hemorragias Intracranianas/cirurgia , Masculino , Pessoa de Meia-Idade , Acidente Vascular Cerebral/mortalidade , Acidente Vascular Cerebral/cirurgia , Trombectomia/instrumentação , Trombectomia/métodos , Estados Unidos/epidemiologia
11.
Circulation ; 136(24): 2311-2321, 2017 Dec 12.
Artigo em Inglês | MEDLINE | ID: mdl-28943516

RESUMO

BACKGROUND: Endovascular treatment with mechanical thrombectomy (MT) is beneficial for patients with acute stroke suffering a large-vessel occlusion, although treatment efficacy is highly time-dependent. We hypothesized that interhospital transfer to endovascular-capable centers would result in treatment delays and worse clinical outcomes compared with direct presentation. METHODS: STRATIS (Systematic Evaluation of Patients Treated With Neurothrombectomy Devices for Acute Ischemic Stroke) was a prospective, multicenter, observational, single-arm study of real-world MT for acute stroke because of anterior-circulation large-vessel occlusion performed at 55 sites over 2 years, including 1000 patients with severe stroke and treated within 8 hours. Patients underwent MT with or without intravenous tissue plasminogen activator and were admitted to endovascular-capable centers via either interhospital transfer or direct presentation. The primary clinical outcome was functional independence (modified Rankin Score 0-2) at 90 days. We assessed (1) real-world time metrics of stroke care delivery, (2) outcome differences between direct and transfer patients undergoing MT, and (3) the potential impact of local hospital bypass. RESULTS: A total of 984 patients were analyzed. Median onset-to-revascularization time was 202.0 minutes for direct versus 311.5 minutes for transfer patients (P<0.001). Clinical outcomes were better in the direct group, with 60.0% (299/498) achieving functional independence compared with 52.2% (213/408) in the transfer group (odds ratio, 1.38; 95% confidence interval, 1.06-1.79; P=0.02). Likewise, excellent outcome (modified Rankin Score 0-1) was achieved in 47.4% (236/498) of direct patients versus 38.0% (155/408) of transfer patients (odds ratio, 1.47; 95% confidence interval, 1.13-1.92; P=0.005). Mortality did not differ between the 2 groups (15.1% for direct, 13.7% for transfer; P=0.55). Intravenous tissue plasminogen activator did not impact outcomes. Hypothetical bypass modeling for all transferred patients suggested that intravenous tissue plasminogen activator would be delayed by 12 minutes, but MT would be performed 91 minutes sooner if patients were routed directly to endovascular-capable centers. If bypass is limited to a 20-mile radius from onset, then intravenous tissue plasminogen activator would be delayed by 7 minutes and MT performed 94 minutes earlier. CONCLUSIONS: In this large, real-world study, interhospital transfer was associated with significant treatment delays and lower chance of good outcome. Strategies to facilitate more rapid identification of large-vessel occlusion and direct routing to endovascular-capable centers for patients with severe stroke may improve outcomes. CLINICAL TRIAL REGISTRATION: URL: https://www.clinicaltrials.gov. Unique identifier: NCT02239640.


Assuntos
Procedimentos Endovasculares , Isquemia/epidemiologia , Transferência de Pacientes/estatística & dados numéricos , Acidente Vascular Cerebral/epidemiologia , Trombectomia , Hospitais , Humanos , Isquemia/mortalidade , Isquemia/cirurgia , Estudos Prospectivos , Sistema de Registros , Acidente Vascular Cerebral/mortalidade , Acidente Vascular Cerebral/cirurgia , Análise de Sobrevida , Fatores de Tempo , Resultado do Tratamento
12.
Stroke ; 48(10): 2760-2768, 2017 10.
Artigo em Inglês | MEDLINE | ID: mdl-28830971

RESUMO

BACKGROUND AND PURPOSE: Mechanical thrombectomy with stent retrievers has become standard of care for treatment of acute ischemic stroke patients because of large vessel occlusion. The STRATIS registry (Systematic Evaluation of Patients Treated With Neurothrombectomy Devices for Acute Ischemic Stroke) aimed to assess whether similar process timelines, technical, and functional outcomes could be achieved in a large real world cohort as in the randomized trials. METHODS: STRATIS was designed to prospectively enroll patients treated in the United States with a Solitaire Revascularization Device and Mindframe Capture Low Profile Revascularization Device within 8 hours from symptom onset. The STRATIS cohort was compared with the interventional cohort of a previously published SEER patient-level meta-analysis. RESULTS: A total of 984 patients treated at 55 sites were analyzed. The mean National Institutes of Health Stroke Scale score was 17.3. Intravenous tissue-type plasminogen activator was administered in 64.0%. The median time from onset to arrival in the enrolling hospital, door to puncture, and puncture to reperfusion were 138, 72, and 36 minutes, respectively. The Core lab-adjudicated modified Thrombolysis in Cerebral Infarction ≥2b was achieved in 87.9% of patients. At 90 days, 56.5% achieved a modified Rankin Scale score of 0 to 2, all-cause mortality was 14.4%, and 1.4% suffered a symptomatic intracranial hemorrhage. The median time from emergency medical services scene arrival to puncture was 152 minutes, and each hour delay in this interval was associated with a 5.5% absolute decline in the likelihood of achieving modified Rankin Scale score 0 to 2. CONCLUSIONS: This largest-to-date Solitaire registry documents that the results of the randomized trials can be reproduced in the community. The decrease of clinical benefit over time warrants optimization of the system of care. CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov. Unique identifier: NCT02239640.


Assuntos
Isquemia Encefálica/diagnóstico , Isquemia Encefálica/terapia , Trombólise Mecânica/normas , Sistema de Registros/normas , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/terapia , Idoso , Isquemia Encefálica/epidemiologia , Estudos de Coortes , Feminino , Humanos , Masculino , Trombólise Mecânica/métodos , Pessoa de Meia-Idade , Estudos Prospectivos , Ensaios Clínicos Controlados Aleatórios como Assunto/normas , Acidente Vascular Cerebral/epidemiologia , Tempo para o Tratamento/normas , Ativador de Plasminogênio Tecidual/administração & dosagem , Resultado do Tratamento
13.
J Neurointerv Surg ; 9(4): 366-369, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-27073195

RESUMO

BACKGROUND: Time to reperfusion following endovascular treatment (ET) predicts outcomes after acute ischemic stroke (AIS). OBJECTIVE: To assess the time-outcome relationship within reperfusion grades in the North American Solitaire Acute Stroke registry. METHODS: We identified patients given ET for anterior circulation ischemic stroke within 8 h from onset and in whom reperfusion was achieved. Together with clinical and outcome data, site-adjudicated modified Thrombolysis in Cerebral Ischemia (TICI) was recorded. We assessed the impact of time to reperfusion (onset to procedure completion time) on good outcome (modified Rankin Scale 0-2 at 3 months) in patients who achieved TICI 2 or higher reperfusion in multivariable models. We further assessed this relationship within strata of reperfusion grades. A p<0.05 was considered significant. RESULTS: Independent predictors of good outcome at 3 months among those achieving TICI ≥2a reperfusion (n=188) were initial National Institutes of Health Stroke Scale score (adjusted OR=0.90, 95% CI 0.85 to 0.95), symptomatic hemorrhage (adj. OR=0.16, 95% CI 0.05 to 0.60), TICI grade (TICI 3: adj. OR=11.52, 95% CI 3.34 to 39.77; TICI 2b: adj. OR=5.14, 95% CI 1.61 to 16.39), and time to reperfusion per 30 min interval (adj. OR=0.91, 95% CI 0.82 to 0.99). There was an interaction between final TICI grade and 30 min time to reperfusion intervals (p=0.001) such that the effect of time was strongest in TICI 2a patients. CONCLUSIONS: Time to reperfusion was a strong predictor of outcome following ET for AIS. However, the effect varied by TICI grade such that its greatest effect was in those achieving TICI 2a reperfusion.


Assuntos
Isquemia Encefálica/fisiopatologia , Infarto Cerebral/fisiopatologia , Infarto Cerebral/terapia , Intervenção Médica Precoce , Reperfusão/instrumentação , Reperfusão/métodos , Acidente Vascular Cerebral/fisiopatologia , Acidente Vascular Cerebral/terapia , Trombectomia/instrumentação , Trombectomia/métodos , Atividades Cotidianas/classificação , Idoso , Isquemia Encefálica/terapia , Estudos de Coortes , Avaliação da Deficiência , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Sistema de Registros , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento
14.
Interv Neurol ; 5(3-4): 101-110, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27781037

RESUMO

BACKGROUND: The Interventional Management of Stroke III (IMS-III) trial demonstrated no benefit for intravenous recombinant tissue plasminogen activator (IV rt-PA) followed by endovascular therapy versus IV rt-PA alone. However, IMS-III mostly included earlier generation devices. The recent thrombectomy trials have incorporated the stent-retriever technology, but their generalizability remains unknown. METHODS: The North American Solitaire Acute Stroke (NASA) registry recruited patients treated with the Solitaire FR™ device between March 2012 and February 2013. The NASA-IMS-III-Like Group (NILG baseline NIHSS score ≥10 who received IV rt-PA) was compared to the IV rt-PA and IV + intra-arterial (IA)-IMS-III groups and the MR CLEAN, ESCAPE, SWIFT Prime, and REVASCAT trial controls to assess the stent-retriever treatment in the 'real-world' setting. The NILG was also compared to non-IV rt-PA NASA patients to evaluate the impact of IV rt-PA on thrombectomy. RESULTS: A total of 136 of the 354 NASA patients fulfilled criteria for the NILG. Baseline characteristics were well balanced across groups. Time from onset to puncture was higher in NILG than IV+IA-IMS-III patients (274 ± 112 vs. 208 ± 47 min, p < 0.0001). Occlusions involving the intracranial ICA, MCA-M1, or basilar arteries were more common in NILG than IV+IA-IMS-III patients (91.2 vs. 47.2%, p < 0.00001). Modified thrombolysis in cerebral infarction ≥2b reperfusion was higher in NILG than IV+IA-IMS-III patients (74.3 vs. 39.6%, p < 0.00001). A 90-day modified Rankin Scale score ≤2 was more frequent in the NILG than IV+IA-IMS-III patients (51.9 vs. 40.8%, p = 0.03) and MR CLEAN (51.9 vs. 19.1%, p < 0.00001), ESCAPE (51.9 vs. 29.3%, p = 0.0002), SWIFT Prime (51.9 vs. 35.5%, p = 0.02), and REVASCAT (51.9 vs. 28.2%, p = 0.0003) controls. Symptomatic intracranial hemorrhage definitions varied across the different studies with rates ranging from 2.7% (ESCAPE) to 11.9% (NILG). The NILG 90-day mortality (24.4%) was higher than in SWIFT Prime but comparable to all other groups. IV rt-PA was an independent predictor of good outcome in NASA (OR = 2.3, 95% CI 1.2-4.7). CONCLUSION: Our results support the 'real-world' applicability of the recent thrombectomy trials.

15.
J Neurointerv Surg ; 8(3): 224-9, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25564538

RESUMO

BACKGROUND: Mechanical thrombectomy with stent-retrievers results in higher recanalization rates compared with previous devices. Despite successful recanalization rates (Thrombolysis in Cerebral Infarction (TICI) score ≥2b) of 70-83%, good outcomes by 90-day modified Rankin Scale (mRS) score ≤2 are achieved in only 40-55% of patients. We evaluated predictors of poor outcomes (mRS >2) despite successful recanalization (TICI ≥2b) in the North American Solitaire Stent Retriever Acute Stroke (NASA) registry. METHODS: Logistic regression was used to evaluate baseline characteristics and recanalization outcomes for association with 90-day mRS score of 0-2 (good outcome) vs 3-6 (poor outcome). Univariate tests were carried out for all factors. A multivariable model was developed based on backwards selection from the factors with at least marginal significance (p≤0.10) on univariate analysis with the retention criterion set at p≤0.05. The model was refit to minimize the number of cases excluded because of missing covariate values; the c-statistic was a measure of predictive power. RESULTS: Of 354 patients, 256 (72.3%) were recanalized successfully. Based on 234 recanalized patients evaluated for 90-day mRS score, 116 (49.6%) had poor outcomes. Univariate analysis identified an increased risk of poor outcome for age ≥80 years, occlusion site of internal carotid artery (ICA)/basilar artery, National Institute of Health Stroke Scale (NIHSS) score ≥18, history of diabetes mellitus, TICI 2b, use of rescue therapy, not using a balloon-guided catheter or intravenous tissue plasminogen activator (IV t-PA), and >30 min to recanalization (p≤0.05). In multivariable analysis, age ≥80 years, occlusion site ICA/basilar, initial NIHSS score ≥18, diabetes, absence of IV t-PA, ≥3 passes, and use of rescue therapy were significant independent predictors of poor 90-day outcome in a model with good predictive power (c-index=0.80). CONCLUSIONS: Age, occlusion site, high NIHSS, diabetes, no IV t-PA, ≥3 passes, and use of rescue therapy are associated with poor 90-day outcome despite successful recanalization.


Assuntos
Sistema de Registros , Reperfusão/métodos , Stents , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/cirurgia , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , América do Norte/epidemiologia , Valor Preditivo dos Testes , Análise de Regressão , Reperfusão/instrumentação , Fatores de Risco , Acidente Vascular Cerebral/diagnóstico , Resultado do Tratamento
16.
Stroke ; 46(8): 2305-8, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26159790

RESUMO

BACKGROUND AND PURPOSE: Failure to recanalize predicts mortality in acute ischemic stroke. In the North American Solitaire Acute Stroke registry, we investigated parameters associated with mortality in successfully recanalized patients. METHODS: Logistic regression was used to evaluate baseline characteristics and recanalization parameters for association with 90-day mortality. A multivariable model was developed based on backward selection with retention criteria of P<0.05 from factors with at least marginal significance (P≤0.10), then refit to minimize the number of excluded cases (missing data). RESULTS: Successfully recanalized patients had lower mortality (25.2% [59/234] versus 46.9% [38/81] P<0.001). There was no difference in symptomatic intracranial hemorrhage between patients with successful versus failed recanalization (9% [21/234] versus 14% [11/79]; P=0.205). However, mortality was significantly higher in patients with symptomatic intracranial hemorrhage (72% [23/32] versus 26% [73/281]; P<0.001). Proximal occlusion (internal carotid artery or vertebrobasilar), initial National Institutes of Health Stroke Scale≥18, use of rescue therapy (P<0.05), and 3+ passes (P<0.10) were associated with mortality in recanalized patients. In the multivariate model with good predictive power (c index=0.72), proximal occlusion, initial National Institutes of Health Stroke Scale≥18, and use of rescue therapy remained significant independent predictors of 90-day mortality. CONCLUSIONS: Failure to recanalize and presence of symptomatic intracranial hemorrhage resulted in increased mortality. Despite successful recanalization, proximal occlusion, high National Institutes of Health Stroke Scale, and need for rescue therapy were predictors of mortality.


Assuntos
Revascularização Cerebral/mortalidade , Sistema de Registros , Acidente Vascular Cerebral/mortalidade , Acidente Vascular Cerebral/cirurgia , Idoso , Idoso de 80 Anos ou mais , Revascularização Cerebral/métodos , Revascularização Cerebral/tendências , Feminino , Humanos , Masculino , Mortalidade/tendências , América do Norte/epidemiologia , Valor Preditivo dos Testes , Estudos Retrospectivos , Fatores de Risco , Acidente Vascular Cerebral/diagnóstico , Resultado do Tratamento
17.
Stroke ; 45(12): 3631-6, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25358699

RESUMO

BACKGROUND AND PURPOSE: The Solitaire With the Intention for Thrombectomy (SWIFT) and thrombectomy revascularization of large vessel occlusions in acute ischemic stroke (TREVO 2) trial results demonstrated improved recanalization rates with mechanical thrombectomy; however, outcomes in the elderly population remain poorly understood. Here, we report the effect of age on clinical and angiographic outcome within the North American Solitaire-FR Stent-Retriever Acute Stroke (NASA) Registry. METHODS: The NASA Registry recruited sites to submit data on consecutive patients treated with Solitaire-FR. Influence of age on clinical and angiographic outcomes was assessed by dichotomizing the cohort into ≤80 and >80 years of age. RESULTS: Three hundred fifty-four patients underwent treatment in 24 centers; 276 patients were ≤80 years and 78 were >80 years of age. Mean age in the ≤80 and >80 cohorts was 62.2±13.2 and 85.2±3.8 years, respectively. Of patients >80 years, 27.3% had a 90-day modified Rankin Score ≤2 versus 45.4% ≤80 years (P=0.02). Mortality was 43.9% and 27.3% in the >80 and ≤80 years cohorts, respectively (P=0.01). There was no significant difference in time to revascularization, revascularization success, or symptomatic intracranial hemorrhage between the groups. Multivariate analysis showed age >80 years as an independent predictor of poor clinical outcome and mortality. Within the >80 cohort, National Institutes of Health Stroke Scale (NIHSS), revascularization rate, rescue therapy use, and symptomatic intracranial hemorrhage were independent predictors of mortality. CONCLUSION: Greater than 80 years of age is predictive of poor clinical outcome and increased mortality compared with younger patients in the NASA registry. However, intravenous tissue-type plasminogen activator use, lower NIHSS, and shorter revascularization time are associated with better outcomes. Further studies are needed to understand the endovascular therapy role in this cohort compared with medical therapy.


Assuntos
Revascularização Cerebral/mortalidade , Acidente Vascular Cerebral/cirurgia , Adulto , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Angiografia Cerebral , Revascularização Cerebral/métodos , Feminino , Humanos , Masculino , Trombólise Mecânica/métodos , Trombólise Mecânica/mortalidade , Pessoa de Meia-Idade , América do Norte , Sistema de Registros , Estudos Retrospectivos , Acidente Vascular Cerebral/mortalidade , Resultado do Tratamento , Adulto Jovem
18.
Stroke ; 45(5): 1396-401, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24668201

RESUMO

BACKGROUND AND PURPOSE: Previous work that predated the availability of the safer stent-retriever devices has suggested that general anesthesia (GA) may have a negative impact on outcomes in patients with acute ischemic stroke undergoing endovascular therapy. METHODS: We reviewed demographic, clinical, procedural (GA versus local anesthesia [LA], etc), and site-adjudicated angiographic and clinical outcomes data from consecutive patients treated with the Solitaire FR device in the investigator-initiated North American SOLITAIRE Stent-Retriever Acute Stroke (NASA) Registry. The primary outcomes were 90-day modified Rankin Scale, mortality, and symptomatic intracranial hemorrhage. RESULTS: A total of 281 patients from 18 centers were enrolled. GA was used in 69.8% (196/281) of patients. Baseline demographic and procedural factors were comparable between the LA and GA groups, except the former demonstrated longer time-to-groin puncture (395.4±254 versus 337.4±208 min; P=0.04), lower National Institutes of Health Stroke Scale (NIHSS; 16.2±5.8 versus 18.8±6.9; P=0.002), lower balloon-guide catheter usage (22.4% versus 49.2%; P=0.0001), and longer fluoroscopy times (39.5±33 versus 28±22.8 min; P=0.008). Recanalization (thrombolysis in cerebral infarction ≥2b; 72.94% versus 73.6%; P=0.9) and rate of symptomatic intracranial hemorrhage (7.1% versus 11.2%; P=0.4) were similar but modified Rankin Scale ≤2 was achieved in more LA patients, 52.6% versus 35.6% (odds ratio, 1.4 [1.1-1.8]; P=0.01). In multivariate analysis, hypertension, NIHSS, unsuccessful revascularization, and GA use (odds ratio, 3.3 [1.6-7.1]; P=0.001) were associated with death. When only anterior circulation and elective GA patients were included, there was a persistent difference in good outcomes in favor of LA patients (50.7% versus 35.5%; odds ratio, 1.3 [1.01-1.6]; P=0.04). CONCLUSIONS: The NASA Registry has demonstrated that clinical outcomes and survival are significantly better in patients treated with LA, without increased symptomatic intracranial hemorrhage risk. Future trials should prospectively evaluate the effect of GA on outcomes.


Assuntos
Anestesia Geral/estatística & dados numéricos , Anestesia Local/estatística & dados numéricos , Isquemia Encefálica/terapia , Procedimentos Endovasculares/estatística & dados numéricos , Sistema de Registros/estatística & dados numéricos , Stents/estatística & dados numéricos , Acidente Vascular Cerebral/terapia , Idoso , Idoso de 80 Anos ou mais , Anestesia Geral/efeitos adversos , Anestesia Geral/mortalidade , Anestesia Local/efeitos adversos , Anestesia Local/mortalidade , Isquemia Encefálica/mortalidade , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/mortalidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , América do Norte , Estudos Retrospectivos , Índice de Gravidade de Doença , Acidente Vascular Cerebral/mortalidade , Resultado do Tratamento
19.
Stroke ; 45(1): 141-5, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24302483

RESUMO

BACKGROUND AND PURPOSE: Efficient and timely recanalization is an important goal in acute stroke endovascular therapy. Several studies demonstrated improved recanalization and clinical outcomes with the stent retriever devices compared with the Merci device. The goal of this study was to evaluate the role of the balloon guide catheter (BGC) and recanalization success in a substudy of the North American Solitaire Acute Stroke (NASA) registry. METHODS: The investigator-initiated NASA registry recruited 24 clinical sites within North America to submit demographic, clinical, site-adjudicated angiographic, and clinical outcome data on consecutive patients treated with the Solitaire Flow Restoration device. BGC use was at the discretion of the treating physicians. RESULTS: There were 354 patients included in the NASA registry. BGC data were reported in 338 of 354 patients in this subanalysis, of which 149 (44%) had placement of a BGC. Mean age was 67.3±15.2 years, and median National Institutes of Health Stroke Scale score was 18. Patients with BGC had more hypertension (82.4% versus 72.5%; P=0.05), atrial fibrillation (50.3% versus 32.8%; P=0.001), and were more commonly administered tissue plasminogen activator (51.6% versus 38.8%; P=0.02) compared with patients without BGC. Time from symptom onset to groin puncture and number of passes were similar between the 2 groups. Procedure time was shorter in patients with BGC (120±28.5 versus 161±35.6 minutes; P=0.02), and less adjunctive therapy was used in patients with BGC (20% versus 28.6%; P=0.05). Thrombolysis in cerebral infarction 3 reperfusion scores were higher in patients with BGC (53.7% versus 32.5%; P<0.001). Distal emboli and emboli in new territory were similar between the 2 groups. Discharge National Institutes of Health Stroke Scale score (mean, 12±14.5 versus 17.5±16; P=0.002) and good clinical outcome at 3 months were superior in patients with BGC compared with patients without (51.6% versus 35.8%; P=0.02). Multivariate analysis demonstrated that the use of BGC was an independent predictor of good clinical outcome (odds ratio, 2.5; 95% confidence interval, 1.2-4.9). CONCLUSIONS: Use of a BGC with the Solitaire Flow Restoration device resulted in superior revascularization results, faster procedure times, decreased need for adjunctive therapy, and improved clinical outcome.


Assuntos
Cateterismo Venoso Central/métodos , Revascularização Cerebral/métodos , Procedimentos Endovasculares/métodos , Stents , Acidente Vascular Cerebral/cirurgia , Idoso , Angiografia Cerebral , Circulação Cerebrovascular/fisiologia , Feminino , Humanos , Trombose Intracraniana/complicações , Masculino , Sistema de Registros , Fatores de Risco , Resultado do Tratamento
20.
J Neurointerv Surg ; 6(8): 584-8, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24062252

RESUMO

BACKGROUND: Limited post-marketing data exist on the use of the Solitaire FR device in clinical practice. The North American Solitaire Stent Retriever Acute Stroke (NASA) registry aimed to assess the real world performance of the Solitaire FR device in contrast with the results from the SWIFT (Solitaire with the Intention for Thrombectomy) and TREVO 2 (Trevo versus Merci retrievers for thrombectomy revascularization of large vessel occlusions in acute ischemic stroke) trials. METHODS: The investigator initiated NASA registry recruited North American sites to submit retrospective angiographic and clinical outcome data on consecutive acute ischemic stroke (AIS) patients treated with the Solitaire FR between March 2012 and February 2013. The primary outcome was a Thrombolysis in Myocardial Ischemia (TIMI) score of ≥2 or a Treatment in Cerebral Infarction (TICI) score of ≥2a. Secondary outcomes were 90 day modified Rankin Scale (mRS) score, mortality, and symptomatic intracranial hemorrhage. RESULTS: 354 patients underwent treatment for AIS using the Solitaire FR device in 24 centers. Mean time from onset to groin puncture was 363.4±239 min, mean fluoroscopy time was 32.9±25.7 min, and mean procedure time was 100.9±57.8 min. Recanalization outcome: TIMI ≥2 rate of 83.3% (315/354) and TICI ≥2a rate of 87.5% (310/354) compared with the operator reported TIMI ≥2 rate of 83% in SWIFT and TICI ≥2a rate of 85% in TREVO 2. CLINICAL OUTCOME: 42% (132/315) of NASA patients demonstrated a 90 day mRS ≤2 compared with 37% (SWIFT) and 40% (TREVO 2). 90 day mortality was 30.2% (95/315) versus 17.2% (SWIFT) and 29% (TREVO 2). CONCLUSIONS: The NASA registry demonstrated that the Solitaire FR device performance in clinical practice is comparable with the SWIFT and TREVO 2 trial results.


Assuntos
Isquemia Encefálica , Circulação Cerebrovascular/fisiologia , Trombólise Mecânica , Avaliação de Resultados em Cuidados de Saúde , Sistema de Registros/estatística & dados numéricos , Acidente Vascular Cerebral , Idoso , Idoso de 80 Anos ou mais , Isquemia Encefálica/diagnóstico , Isquemia Encefálica/mortalidade , Isquemia Encefálica/cirurgia , Feminino , Humanos , Masculino , Trombólise Mecânica/instrumentação , Trombólise Mecânica/mortalidade , Trombólise Mecânica/estatística & dados numéricos , Pessoa de Meia-Idade , América do Norte , Stents/estatística & dados numéricos , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/mortalidade , Acidente Vascular Cerebral/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...