Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 39
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Molecules ; 28(16)2023 Aug 16.
Artigo em Inglês | MEDLINE | ID: mdl-37630339

RESUMO

The issue of food fraud has become a significant global concern as it affects both the quality and safety of food products, ultimately resulting in the loss of customer trust and brand loyalty. To address this problem, we have developed an innovative approach that can tackle various types of food fraud, including adulteration, substitution, and dilution. Our methodology utilizes an integrated system that combines laser-induced breakdown spectroscopy (LIBS) and Raman spectroscopy. Although both techniques emerged as valuable tools for food analysis, they have until now been used separately, and their combined potential in food fraud has not been thoroughly tested. The aim of our study was to demonstrate the potential benefits of integrating Raman and LIBS modalities in a portable system for improved product classification and subsequent authentication. In pursuit of this objective, we designed and tested a compact, hybrid Raman/LIBS system, which exhibited distinct advantages over the individual modalities. Our findings illustrate that the combination of these two modalities can achieve higher accuracy in product classification, leading to more effective and reliable product authentication. Overall, our research highlights the potential of hybrid systems for practical applications in a variety of industries. The integration and design were mainly focused on the detection and characterization of both elemental and molecular elements in various food products. Two different sets of solid food samples (sixteen Alpine-style cheeses and seven brands of Arabica coffee beans) were chosen for the authentication analysis. Class detection and classification were accomplished through the use of multivariate feature selection and machine-learning procedures. The accuracy of classification was observed to improve by approximately 10% when utilizing the hybrid Raman/LIBS spectra, as opposed to the analysis of spectra from the individual methods. This clearly demonstrates that the hybrid system can significantly improve food authentication accuracy while maintaining the portability of the combined system. Thus, the successful implementation of a hybrid Raman-LIBS technique is expected to contribute to the development of novel portable devices for food authentication in food as well as other various industries.


Assuntos
Queijo , Análise Espectral Raman , Contaminação de Medicamentos , Fraude , Indústrias
2.
Sensors (Basel) ; 23(7)2023 Mar 27.
Artigo em Inglês | MEDLINE | ID: mdl-37050545

RESUMO

The elastic light-scatter (ELS) technique, which detects and discriminates microbial organisms based on the light-scatter pattern of their colonies, has demonstrated excellent classification accuracy in pathogen screening tasks. The implementation of the multispectral approach has brought further advantages and motivated the design and validation of a hyperspectral elastic light-scatter phenotyping instrument (HESPI). The newly developed instrument consists of a supercontinuum (SC) laser and an acousto-optic tunable filter (AOTF). The use of these two components provided a broad spectrum of excitation light and a rapid selection of the wavelength of interest, which enables the collection of multiple spectral patterns for each colony instead of relying on single band analysis. The performance was validated by classifying microflora of green-leafed vegetables using the hyperspectral ELS patterns of the bacterial colonies. The accuracy ranged from 88.7% to 93.2% when the classification was performed with the scattering pattern created at a wavelength within the 473-709 nm region. When all of the hyperspectral ELS patterns were used, owing to the vastly increased size of the data, feature reduction and selection algorithms were utilized to enhance the robustness and ultimately lessen the complexity of the data collection. A new classification model with the feature reduction process improved the overall classification rate to 95.9%.


Assuntos
Bactérias , Elasticidade , Luz , Fenômenos Fisiológicos Bacterianos , Algoritmos
3.
Sensors (Basel) ; 23(4)2023 Feb 14.
Artigo em Inglês | MEDLINE | ID: mdl-36850732

RESUMO

Real-time detection and disinfection of foodborne pathogens are important for preventing foodborne outbreaks and for maintaining a safe environment for consumers. There are numerous methods for the disinfection of hazardous organisms, including heat treatment, chemical reaction, filtration, and irradiation. This report evaluated a portable instrument to validate its simultaneous detection and disinfection capability in typical laboratory situations. In this challenging study, three gram-negative and two gram-positive microorganisms were used. For the detection of contamination, inoculations of various concentrations were dispensed on three different surface types to estimate the performance for minimum-detectable cell concentration. Inoculations higher than 103~104 CFU/mm2 and 0.15 mm of detectable contaminant size were estimated to generate a sufficient level of fluorescence signal. The evaluation of disinfection efficacy was conducted on three distinct types of surfaces, with the energy density of UVC light (275-nm) ranging from 4.5 to 22.5 mJ/cm2 and the exposure time varying from 1 to 5 s. The study determined the optimal energy dose for each of the microorganisms species. In addition, surface characteristics may also be an important factor that results in different inactivation efficacy. These results demonstrate that the proposed portable device could serve as an in-field detection and disinfection unit in various environments, and provide a more efficient and user-friendly way of performing disinfection on large surface areas.


Assuntos
Desinfecção , Filtração , Fenômenos Físicos , Surtos de Doenças , Contaminação de Medicamentos
4.
Foods ; 12(2)2023 Jan 14.
Artigo em Inglês | MEDLINE | ID: mdl-36673494

RESUMO

Laser-induced breakdown spectroscopy (LIBS) is an atomic-emission spectroscopy technique that employs a focused laser beam to produce microplasma. Although LIBS was designed for applications in the field of materials science, it has lately been proposed as a method for the compositional analysis of agricultural goods. We deployed commercial handheld LIBS equipment to illustrate the performance of this promising optical technology in the context of food authentication, as the growing incidence of food fraud necessitates the development of novel portable methods for detection. We focused on regional agricultural commodities such as European Alpine-style cheeses, coffee, spices, balsamic vinegar, and vanilla extracts. Liquid examples, including seven balsamic vinegar products and six representatives of vanilla extract, were measured on a nitrocellulose membrane. No sample preparation was required for solid foods, which consisted of seven brands of coffee beans, sixteen varieties of Alpine-style cheeses, and eight different spices. The pre-processed and standardized LIBS spectra were used to train and test the elastic net-regularized multinomial classifier. The performance of the portable and benchtop LIBS systems was compared and described. The results indicate that field-deployable, portable LIBS devices provide a robust, accurate, and simple-to-use platform for agricultural product verification that requires minimal sample preparation, if any.

5.
Sensors (Basel) ; 22(22)2022 Nov 18.
Artigo em Inglês | MEDLINE | ID: mdl-36433525

RESUMO

Demonstration of the Salmonella Typhimurium detection system was shown utilizing a quartz crystal microbalance (QCM) biosensor and signal enhancement by gold nanoparticles. In this study, a benchtop system of a QCM biosensor was utilized for the detection of Salmonella Typhimurium. It was designed with a peristaltic pump system to achieve immobilization of antibodies, detection of Salmonella, and the addition of gold nanoparticles to the sensor. As a series of biochemical solutions were introduced to the surface, the proposed system was able to track the changes in the resonant frequency which were proportional to the variations of mass on the sensor. For antibody immobilization, polyclonal antibodies were immobilized via self-assembled monolayers to detect Salmonella O-antigen. Subsequently, Salmonella Typhimurium was detected by antibodies and the average frequency before and after detecting Salmonella was compared. The highest frequency shifts were −26.91 Hz for 109 CFU/mL while the smallest frequency shift was −3.65 Hz corresponding to 103 CFU/mL. For the specificity tests, non-Salmonella samples such as E. coli, Listeria, and Staphylococcus resulted in low cross-reactivity. For signal amplification, biotinylated antibodies reacted to Salmonella followed by streptavidin­100 nm AuNPs through biotin-avidin interaction. The frequency shifts of 103 CFU/mL showed −28.04 Hz, and consequently improved the limit of detection.


Assuntos
Técnicas Biossensoriais , Nanopartículas Metálicas , Técnicas de Microbalança de Cristal de Quartzo/métodos , Ouro/química , Salmonella typhimurium , Escherichia coli , Nanopartículas Metálicas/química , Técnicas Biossensoriais/métodos
6.
Sensors (Basel) ; 22(7)2022 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-35408260

RESUMO

We present a smartphone-based bacterial colony phenotyping instrument using a reflective elastic light scattering (ELS) pattern and the resolving power of the new instrument. The reflectance-type device can acquire ELS patterns of colonies on highly opaque media as well as optically dense colonies. The novel instrument was built using a smartphone interface and a 532 nm diode laser, and these essential optical components made it a cost-effective and portable device. When a coherent and collimated light source illuminated a bacterial colony, a reflective ELS pattern was created on the screen and captured by the smartphone camera. The collected patterns whose shapes were determined by the colony morphology were then processed and analyzed to extract distinctive features for bacterial identification. For validation purposes, the reflective ELS patterns of five bacteria grown on opaque growth media were measured with the proposed instrument and utilized for the classification. Cross-validation was performed to evaluate the classification, and the result showed an accuracy above 94% for differentiating colonies of E. coli, K. pneumoniae, L. innocua, S. enteritidis, and S. aureus.


Assuntos
Escherichia coli , Dispositivos Ópticos , Bactérias , Meios de Cultura , Smartphone , Staphylococcus aureus
7.
Sensors (Basel) ; 21(11)2021 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-34200440

RESUMO

Volatile organic compounds (VOCs) are chemicals emitted by various groups, such as foods, bacteria, and plants. While there are specific pathways and biological features significantly related to such VOCs, detection of these is achieved mostly by human odor testing or high-end methods such as gas chromatography-mass spectrometry that can analyze the gaseous component. However, odor characterization can be quite helpful in the rapid classification of some samples in sufficient concentrations. Lower-cost metal-oxide gas sensors have the potential to allow the same type of detection with less training required. Here, we report a portable, battery-powered electronic nose system that utilizes multiple metal-oxide gas sensors and machine learning algorithms to detect and classify VOCs. An in-house circuit was designed with ten metal-oxide sensors and voltage dividers; an STM32 microcontroller was used for data acquisition with 12-bit analog-to-digital conversion. For classification of target samples, a supervised machine learning algorithm such as support vector machine (SVM) was applied to classify the VOCs based on the measurement results. The coefficient of variation (standard deviation divided by mean) of 8 of the 10 sensors stayed below 10%, indicating the excellent repeatability of these sensors. As a proof of concept, four different types of wine samples and three different oil samples were classified, and the training model reported 100% and 98% accuracy based on the confusion matrix analysis, respectively. When the trained model was challenged against new sets of data, sensitivity and specificity of 98.5% and 98.6% were achieved for the wine test and 96.3% and 93.3% for the oil test, respectively, when the SVM classifier was used. These results suggest that the metal-oxide sensors are suitable for usage in food authentication applications.


Assuntos
Nariz Eletrônico , Compostos Orgânicos Voláteis , Cromatografia Gasosa-Espectrometria de Massas , Humanos , Aprendizado de Máquina , Odorantes/análise , Compostos Orgânicos Voláteis/análise
8.
J Microbiol Methods ; 188: 106288, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34280431

RESUMO

Salmonella spp. are a foodborne pathogen frequently found in raw meat, egg products, and milk. Salmonella is responsible for numerous outbreaks, becoming a frequent major public-health concern. Many studies have recently reported handheld and rapid devices for microbial detection. This study explored a smartphone-based lateral-flow assay analyzer which employed machine-learning algorithms to detect various concentrations of Salmonella spp. from the test line images. When cell numbers are low, a faint test line is difficult to detect, leading to misleading results. Hence, this study focused on the development of a smartphone-based lateral-flow assay (SLFA) to distinguish ambiguous concentrations of test line with higher confidence. A smartphone cradle was designed with an angled slot to maximize the intensity, and the optimal direction of the optimal incident light was found. Furthermore, the combination of color spaces and the machine-learning algorithms were applied to the SLFA for classifications. It was found that the combination of L*a*b and RGB color space with SVM and KNN classifiers achieved the high accuracy (95.56%). A blind test was conducted to evaluate the performance of devices; the results by machine-learning techniques reported less error than visual inspection. The smartphone-based lateral-flow assay provided accurate interpretation with a detection limit of 5 × 104 CFU/mL commercially available lateral-flow assays.


Assuntos
Técnicas Bacteriológicas/métodos , Diagnóstico por Imagem/métodos , Aprendizado de Máquina , Salmonella/isolamento & purificação , Smartphone , Animais , Técnicas Biossensoriais/instrumentação , Colorimetria/instrumentação , Diagnóstico por Imagem/instrumentação , Microbiologia de Alimentos , Humanos , Infecções por Salmonella
9.
PLoS One ; 16(2): e0247721, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33630969

RESUMO

A single instrument that includes multiple optical channels was developed to simultaneously measure various optical and associated biophysical characteristics of a bacterial colony. The multi-channel device can provide five distinct optical features without the need to transfer the sample to multiple locations or instruments. The available measurement channels are bright-field light microscopy, 3-D colony-morphology map, 2-D spatial optical-density distribution, spectral forward-scattering pattern, and spectral optical density. The series of multiple morphological interrogations is beneficial in understanding the bio-optical features of a bacterial colony and the correlations among them, resulting in an enhanced power of phenotypic bacterial discrimination. To enable a one-shot interrogation, a confocal laser scanning module was built as an add-on to an upright microscope. Three different-wavelength diode lasers were used for the spectral analysis, and high-speed pin photodiodes and CMOS sensors were utilized as detectors to measure the spectral OD and light-scatter pattern. The proposed instrument and algorithms were evaluated with four bacterial genera, Escherichia coli, Listeria innocua, Salmonella Typhimurium, and Staphylococcus aureus; their resulting data provided a more complete picture of the optical characterization of bacterial colonies.


Assuntos
Bactérias/crescimento & desenvolvimento , Microscopia/instrumentação
10.
Appl Opt ; 59(3): 801-810, 2020 Jan 20.
Artigo em Inglês | MEDLINE | ID: mdl-32225212

RESUMO

The silicon photomultiplier (SiPM) for low light detection has many advantages when compared to existing photon counting detectors, such as high sensitivity, low cost, robustness, and compact hardware. To facilitate the use of SiPM as a portable, field deployable device, an electrical circuit was designed consisting of an amplifier, comparator, and microcontroller. In addition, a 3D printing was used to create a portable cradle for housing the SiPM. To evaluate its detection ability, a laser experiment and bioluminescent experiments, including Pseudomonas fluorescens M3A detection, E. coli O157:H7 PhiV10nluc lysogen detection, and a luminescence-based detection of E. coli O157:H7 in ground meat using the engineered luminescent-based reporter phage PhiV10nluc, were conducted. In the same experimental setting, our previously developed smartphone-based luminometer called the bioluminescent-based analyte quantitation by smartphone and a conventional photomultiplier tube-based benchtop luminometer were used to compare detection levels and applicability for supporting luminescent phage-based pathogen detection. Results showed that the SiPM provides better performance in terms of time to detection and SNR and could be used as the light detection component of the PhiV10nluc phage-based detection format.


Assuntos
Técnicas Biossensoriais/instrumentação , Escherichia coli O157/isolamento & purificação , Medições Luminescentes/instrumentação , Pseudomonas fluorescens/isolamento & purificação , Carne Vermelha/microbiologia , Animais , Técnicas Biossensoriais/métodos , Calibragem , Bovinos , Desenho de Equipamento , Escherichia coli O157/metabolismo , Contaminação de Alimentos , Microbiologia de Alimentos , Lasers , Luz , Luminescência , Medições Luminescentes/métodos , Fótons , Impressão Tridimensional , Pseudomonas fluorescens/metabolismo , Razão Sinal-Ruído , Silício , Smartphone
11.
Anal Bioanal Chem ; 412(6): 1291-1301, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31989196

RESUMO

This study explores the adoption of laser-induced breakdown spectroscopy (LIBS) for the analysis of lateral-flow immunoassays (LFIAs). Gold (Au) nanoparticles are standard biomolecular labels among LFIAs, typically detected via colorimetric means. A wide diversity of lanthanide-complexed polymers (LCPs) are also used as immunoassay labels but are inapt for LFIAs due to lab-bound detection instrumentation. This is the first study to show the capability of LIBS to transition LCPs into the realm of LFIAs, and one of the few to apply LIBS to biomolecular label detection in complete immunoassays. Initially, an in-house LIBS system was optimized to detect an Au standard through a process of line selection across acquisition delay times, followed by determining limit of detection (LOD). The optimized LIBS system was applied to Au-labeled Escherichia coli detection on a commercial LFIA; comparison with colorimetric detection yielded similar LODs (1.03E4 and 8.890E3 CFU/mL respectively). Optimization was repeated with lanthanide standards to determine if they were viable alternatives to Au labels. It was found that europium (Eu) and ytterbium (Yb) may be more favorable biomolecular labels than Au. To test whether Eu-complexed polymers conjugated to antibodies could be used as labels in LFIAs, the conjugates were successfully applied to E. coli detection in a modified commercial LFIA. The results suggest interesting opportunities for creating highly multiplexed LFIAs. Multiplexed, sensitive, portable, and rapid LIBS detection of biomolecules concentrated and labeled on LFIAs is highly relevant for applications like food safety, where in-field food contaminant detection is critical. Graphical abstract.


Assuntos
Anticorpos Antibacterianos/química , Escherichia coli/isolamento & purificação , Lasers , Metais/química , Análise Espectral/métodos
12.
J Microbiol Methods ; 168: 105800, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31809829

RESUMO

We report an application for the smartphone as an accurate and unbiased reading platform of a lateral flow immunoassays for food safety application. In particular, this report focuses on detection of food-borne bacteria in samples extracted from food matrices such as ground beef and spinach. The lateral flow assay is a widely accepted methodology owing to its on-site results, low-cost analysis, and ease of use with minimum user inputs, even though sensitivity is not quite equivalent to that of standard laboratory equipment. An antibody-antigen relationship is transduced into a color change on a nitrocellulose pad while visual interpretation of this color change can result in uncertainty, particularly near the detection limit of the assay. Employing the high resolution integrated camera, constant illumination from light source, and computing power of a smartphone, we provide an objective and accurate method to determine the bacterial cell concentration in a food matrix based on the regression model from the color intensity of test lines. A 3D-printed sample holder was designed for representative commercial lateral flow assays and an in-house application was developed in Android Studio to solve the inverse problem to provide cell concentration information from the color intensity. Test results with E.coli O157:H7 as a model organism suggests that smartphone-based reader can detect 104-105 CFU/ml from ground beef and spinach food matrices.


Assuntos
Escherichia coli O157/isolamento & purificação , Microbiologia de Alimentos/métodos , Imunoensaio/métodos , Imagem Óptica/instrumentação , Imagem Óptica/métodos , Smartphone , Animais , Bovinos , Contagem de Colônia Microbiana , Cor , Contaminação de Alimentos/análise , Microbiologia de Alimentos/instrumentação , Imunoensaio/instrumentação , Aplicativos Móveis , Estudo de Prova de Conceito , Carne Vermelha/microbiologia , Spinacia oleracea/microbiologia
13.
J Biophotonics ; 12(12): e201900149, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31386275

RESUMO

An optical forward-scatter model was generalized to encompass the diverse nature of bacterial colony morphologies and the spectral information. According to the model, the colony shape and the wavelength of incident light significantly affect the characteristics of a forward elastic-light-scattering pattern. To study the relationship between the colony morphology and the scattering pattern, three-dimensional colony models were generated in various morphologies. The propagation of light passing through the colony model was then simulated. In validation of the theoretical modeling, the scattering patterns of three bacterial genera, Staphylococcus, Exiguobacterium and Bacillus, which grow into colonies having convex, crateriform and flat elevations, respectively, were qualitatively compared to the simulated scattering patterns. The strong correlations observed between simulated and experimental patterns validated the scatter model. In addition, spectral effect on the scattering pattern was studied using the scatter model, and experimentally investigated using Staphylococcus, whose colony has circular form and convex elevation. Both simulation and experiment showed that changes in wavelength affected the overall pattern size and the number of rings.


Assuntos
Bactérias/crescimento & desenvolvimento , Bactérias/efeitos da radiação , Luz , Modelos Biológicos , Espalhamento de Radiação
14.
Appl Spectrosc ; 73(6): 698-708, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30990055

RESUMO

A compact spark-induced plasma spectroscopic device was developed to detect elements used in a variety of applications. The system consists of a spark generator connected to tungsten electrodes, a custom-built delay generator, and two spectrometers that together cover the ultraviolet visible (UV-Vis) range (214-631 nm). The system was evaluated by qualitatively and quantitatively sampling copper standards. Prominent spectral peaks were identified using the NIST database for atomic emissions. The effectiveness of the proposed system was also tested with a lanthanide sample (gadolinium) and provided qualitative identification of the characteristic peaks. A semi-quantitative measurement for silicon and gold was performed using variable amounts of each particulate. Silica microbeads in solution were applied to paper wafers, while gold nanoparticles were sputter-coated onto silicon wafers. Results showed a positive correlation between the intensity of the signal and the concentration of each type of particulate. The variation of signal intensity was investigated to determine the repeatability, and the coefficient of variation was lowered from 60% to 25% after averaging measurements of multiple ablations per observation.

15.
Sci Rep ; 7: 40203, 2017 01 09.
Artigo em Inglês | MEDLINE | ID: mdl-28067287

RESUMO

We report a smartphone-based device and associated imaging-processing algorithm to maximize the sensitivity of standard smartphone cameras, that can detect the presence of single-digit pW of radiant flux intensity. The proposed hardware and software, called bioluminescent-based analyte quantitation by smartphone (BAQS), provides an opportunity for onsite analysis and quantitation of luminescent signals from biological and non-biological sensing elements which emit photons in response to an analyte. A simple cradle that houses the smartphone, sample tube, and collection lens supports the measuring platform, while noise reduction by ensemble averaging simultaneously lowers the background and enhances the signal from emitted photons. Five different types of smartphones, both Android and iOS devices, were tested, and the top two candidates were used to evaluate luminescence from the bioluminescent reporter Pseudomonas fluorescens M3A. The best results were achieved by OnePlus One (android), which was able to detect luminescence from ~106 CFU/mL of the bio-reporter, which corresponds to ~107 photons/s with 180 seconds of integration time.


Assuntos
Medições Luminescentes/instrumentação , Medições Luminescentes/métodos , Fótons , Smartphone , Algoritmos , Técnicas Biossensoriais/instrumentação , Técnicas Biossensoriais/métodos , Processamento de Imagem Assistida por Computador/instrumentação , Processamento de Imagem Assistida por Computador/métodos , Razão Sinal-Ruído
16.
J Biophotonics ; 10(5): 634-644, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-27412151

RESUMO

We report a multispectral elastic-light-scatter instrument that can simultaneously detect three-wavelength scatter patterns and associated optical densities from individual bacterial colonies, overcoming the limits of the single-wavelength predecessor. Absorption measurements on liquid bacterial samples revealed that the spectroscopic information can indeed contribute to sample differentiability. New optical components, including a pellicle beam splitter and an optical cage system, were utilized for robust acquisition of multispectral images. Four different genera and seven shiga toxin producing E. coli serovars were analyzed; the acquired images showed differences in scattering characteristics among the tested organisms. In addition, colony-based spectral optical-density information was also collected. The optical model, which was developed using diffraction theory, correctly predicted wavelength-related differences in scatter patterns, and was matched with the experimental results. Scatter-pattern classification was performed using pseudo-Zernike (GPZ) polynomials/moments by combining the features collected at all three wavelengths and selecting the best features via a random-forest method. The data demonstrate that the selected features provide better classification rates than the same number of features from any single wavelength. Three wavelength-merged scatter pattern from E. coli.


Assuntos
Escherichia coli/crescimento & desenvolvimento , Luz , Dispositivos Ópticos , Análise Espectral , Algoritmos
17.
J Biomed Opt ; 21(10): 107004, 2016 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-27775748

RESUMO

A phenotyping of bacterial colonies on agar plates using forward-scattering diffraction-pattern analysis provided promising classification of several different bacteria such as Salmonella, Vibrio, Listeria, and E. coli. Since the technique is based on forward-scattering phenomena, light transmittance of both the colony and the medium is critical to ensure quality data. However, numerous microorganisms and their growth media allow only limited light penetration and render the forward-scattering measurement a challenging task. For example, yeast, Lactobacillus, mold, and several soil bacteria form colorful and dense colonies that obstruct most of the incoming light passing through them. Moreover, blood agar, which is widely utilized in the clinical field, completely blocks the incident coherent light source used in forward scatterometry. We present a newly designed reflection scatterometer and validation of the resolving power of the instrument. The reflectance-type instrument can acquire backward elastic scatter patterns for both highly opaque media and colonies and has been tested with three different bacterial genera grown on blood agar plates. Cross-validation results show a classification rate above 90% for four genera.


Assuntos
Bactérias/química , Bactérias/classificação , Técnicas Bacteriológicas/métodos , Espalhamento de Radiação , Algoritmos , Técnicas Bacteriológicas/instrumentação , Desenho de Equipamento , Processamento de Imagem Assistida por Computador , Luz , Processamento de Sinais Assistido por Computador
18.
Appl Environ Microbiol ; 82(11): 3256-3268, 2016 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-26994085

RESUMO

UNLABELLED: In this study, we investigated whether a laser scatterometer designated BARDOT (bacterial rapid detection using optical scattering technology) could be used to directly screen colonies of Listeria monocytogenes, a model pathogen, with mutations in several known virulence genes, including the genes encoding Listeria adhesion protein (LAP; lap mutant), internalin A (ΔinlA strain), and an accessory secretory protein (ΔsecA2 strain). Here we show that the scatter patterns of lap mutant, ΔinlA, and ΔsecA2 colonies were markedly different from that of the wild type (WT), with >95% positive predictive values (PPVs), whereas for the complemented mutant strains, scatter patterns were restored to that of the WT. The scatter image library successfully distinguished the lap mutant and ΔinlA mutant strains from the WT in mixed-culture experiments, including a coinfection study using the Caco-2 cell line. Among the biophysical parameters examined, the colony height and optical density did not reveal any discernible differences between the mutant and WT strains. We also found that differential LAP expression in L. monocytogenes serotype 4b strains also affected the scatter patterns of the colonies. The results from this study suggest that BARDOT can be used to screen and enumerate mutant strains separately from the WT based on differential colony scatter patterns. IMPORTANCE: In studies of microbial pathogenesis, virulence-encoding genes are routinely disrupted by deletion or insertion to create mutant strains. Screening of mutant strains is an arduous process involving plating on selective growth media, replica plating, colony hybridization, DNA isolation, and PCR or immunoassays. We applied a noninvasive laser scatterometer to differentiate mutant bacterial colonies from WT colonies based on forward optical scatter patterns. This study demonstrates that BARDOT can be used as a novel, label-free, real-time tool to aid researchers in screening virulence gene-associated mutant colonies during microbial pathogenesis, coinfection, and genetic manipulation studies.


Assuntos
Proteínas de Bactérias/metabolismo , Técnicas Bacteriológicas/métodos , Lasers , Listeria monocytogenes/classificação , Proteínas de Membrana/deficiência , Propriedades de Superfície , Fatores de Virulência/deficiência , Proteínas de Bactérias/análise , Fenômenos Biofísicos , Listeria monocytogenes/química , Proteínas de Membrana/análise , Fatores de Virulência/análise
19.
Expert Rev Anti Infect Ther ; 14(2): 207-18, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26582139

RESUMO

Despite the advancement of recent molecular technologies, culturing is still considered the gold standard for microbial sample analysis. Here we review three different bacterial colony-based screening modalities that provide significant information beyond the simple shape and color of the colony. The plate imaging technique provides numeration and quantitative spectral reflectance information for each colony, while Raman spectroscopic analysis of bacteria colonies relates the Raman-shifted peaks to specific chemical bonding. Finally, the elastic-light-scatter technique provides a volumetric interaction of the whole colony through laser-bacteria interactions, instantly capturing the morphological traits of the colony and allowing quantitative classifications.


Assuntos
Bactérias/crescimento & desenvolvimento , Técnicas Bacteriológicas/métodos , Bactérias/química , Contagem de Colônia Microbiana , Processamento de Imagem Assistida por Computador , Fotografação/métodos , Análise Espectral Raman/métodos
20.
Appl Opt ; 54(31): 9183-9, 2015 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-26560572

RESUMO

A simple device and associated analytical methods are reported. We provide objective and accurate determination of saliva alcohol concentrations using smartphone-based colorimetric imaging. The device utilizes any smartphone with a miniature attachment that positions the sample and provides constant illumination for sample imaging. Analyses of histograms based on channel imaging of red-green-blue (RGB) and hue-saturation-value (HSV) color space provide unambiguous determination of blood alcohol concentration from color changes on sample pads. A smartphone-based sample analysis by colorimetry was developed and tested with blind samples that matched with the training sets. This technology can be adapted to any smartphone and used to conduct color change assays.


Assuntos
Colorimetria/instrumentação , Etanol/análise , Aplicativos Móveis , Fitas Reagentes , Saliva/química , Smartphone/instrumentação , Algoritmos , Colorimetria/métodos , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Iluminação/instrumentação , Iluminação/métodos , Aprendizado de Máquina , Miniaturização , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Manejo de Espécimes/instrumentação , Manejo de Espécimes/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...