1.
Radiat Oncol ; 9: 273, 2014 Dec 04.
Artigo em Inglês | MEDLINE | ID: mdl-25472838

RESUMO

PURPOSE: The aim of this study is to evaluate the ability of transit dosimetry using commercial treatment planning system (TPS) and an electronic portal imaging device (EPID) with simple calibration method to verify the beam delivery based on detection of large errors in treatment room. METHODS AND MATERIALS: Twenty four fields of intensity modulated radiotherapy (IMRT) plans were selected from four lung cancer patients and used in the irradiation of an anthropomorphic phantom. The proposed method was evaluated by comparing the calculated dose map from TPS and EPID measurement on the same plane using a gamma index method with a 3% dose and 3 mm distance-to-dose agreement tolerance limit. RESULTS: In a simulation using a homogeneous plastic water phantom, performed to verify the effectiveness of the proposed method, the average passing rate of the transit dose based on gamma index was high enough, averaging 94.2% when there was no error during beam delivery. The passing rate of the transit dose for 24 IMRT fields was lower with the anthropomorphic phantom, averaging 86.8% ± 3.8%, a reduction partially due to the inaccuracy of TPS calculations for inhomogeneity. Compared with the TPS, the absolute value of the transit dose at the beam center differed by -0.38% ± 2.1%. The simulation study indicated that the passing rate of the gamma index was significantly reduced, to less than 40%, when a wrong field was erroneously irradiated to patient in the treatment room. CONCLUSIONS: This feasibility study suggested that transit dosimetry based on the calculation with commercial TPS and EPID measurement with simple calibration can provide information about large errors for treatment beam delivery.


Assuntos
Radiometria/métodos , Radioterapia de Intensidade Modulada/métodos , Algoritmos , Calibragem , Estudos de Viabilidade , Humanos , Neoplasias Pulmonares/radioterapia , Imagens de Fantasmas , Garantia da Qualidade dos Cuidados de Saúde , Dosagem Radioterapêutica
2.
Health Phys ; 107(3): 200-5, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25068957

RESUMO

The authors have developed and evaluated a new method that uses transit dose in the treatment room in verification of dose delivery to patients. Five intensity modulated radiotherapy (IMRT) plans were selected from actual cancer patients, and transit dose was measured using MapCHECK 2 and an anthropomorphic phantom. The criteria used as a verification tool for the dose delivery to the patient were gamma-index-based dose comparison between the computed dose and measured dose. When the doses were delivered to an anthropomorphic phantom normally, the average passing rate was 95.2% based on a gamma index analysis. This feasibility study suggested that transit dose-based quality assurance can provide information about the accuracy of an inhomogeneity correction algorithm and patient positioning during treatment, allowing its use as a verification tool for actual dose delivery to patients in the treatment room.


Assuntos
Doses de Radiação , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Estudos de Viabilidade , Humanos , Neoplasias/radioterapia , Imagens de Fantasmas , Radiometria , Dosagem Radioterapêutica