1.
Phys Med Biol ; 68(22)2023 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-37852274

RESUMO

Metallic nanoparticles, such as gold (Au, Z = 79) and silver (Ag, Z = 47) nanoparticles (AuNPs and AgNPs, respectively), possess strong surface plasmonic resonance (SPR) and high atomic number, which makes them ideal candidates for enhancing dosimeter sensitivity. In this study, we have inserted different mass percentages (from 0 to 0.015 wt%) of AuNPs into a gelatinous Fricke-xylenol-orange (FXO-f) gel matrix and irradiated it with doses ranging from 2 to 32 Gy, using a source of x-ray of low energy with an effective energy of 42 keV. Optical absorption increased significantly; sensitivity gains of up to 50% were achieved for the FXO-f gel matrix containing 0.011 wt% AuNPs. To elucidate the mechanism underlying this increased sensitivity, we also evaluated FXO-f gel matrixes containing AgNPs. AgNPs insertion into the FXO-f gel matrix did not enhance sensitivity, which suggested that the AgNPs plasmonic absorption band and the FXO-f gel matrix absorption band at 441 nm overlapped, to increase absorption even after the gel matrix was irradiated. To visualize the dose distribution, we recorded optical tomography and acquired 3D reconstruction maps. In addition, we analyzed the dose enhancement factor (DEF) by using magnetic resonance images. AuNPs insertion into the FXO-f gel matrix resulted in a DEF gain of 1.37, associated with the photoelectric effect originating from the increased number of free radicals.


Assuntos
Ouro , Nanopartículas Metálicas , Radiometria/métodos , Imageamento por Ressonância Magnética
2.
Biomed Phys Eng Express ; 6(5): 055017, 2020 09 08.
Artigo em Inglês | MEDLINE | ID: mdl-33444248

RESUMO

Polymer gel dosimeters are instrumental for clinical and research applications in radiotherapy. These dosimeters possess the unique ability to record dose distribution in three dimensions. A Polymer gel dosimeter is composed of organic molecules in a gel matrix, which upon irradiation polymerize to form a conjugated polymer with optical absorbance proportional to the irradiated dose. Other required characteristics of a radiotherapy clinical dosimeter are soft-tissue equivalency, linear dose-response in a range of clinical treatments, and long term stability for the duration of the analysis. The dosimeter presented in this paper is based on diacetylene bearing fatty acid aggregates embedded in a soft-tissue equivalent gel matrix, Phytagel™, which upon irradiation polymerize to form a blue phase polydiacetylene with a strong optical absorption. Initial characterization showed that PDA-gel irradiated with 160 kV x-ray responded linearly to the irradiated dose, and the calculated diffusion coefficient is [Formula: see text] what is very low. It was also found that the percentage depth dose (PDD) curve of the PDA-gel in a 4 × 4 cm2 field, irradiated with 6 MV x-rays, was with good agreement with the literature. PDA-gel has the potential to detect absorbed dose in a range of clinical radiological irradiation regimes.


Assuntos
Géis/química , Polímero Poliacetilênico/química , Polímeros/química , Dosímetros de Radiação/estatística & dados numéricos , Radiometria/instrumentação , Humanos , Dosagem Radioterapêutica
3.
Phys Med ; 34: 1-6, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28108100

RESUMO

Intensity modulated radiotherapy (IMRT) is one of the most modern radiation therapy treatment techniques. Although IMRT can deliver high and complex conformational doses to the tumor volume, its implementation requires rigorous quality assurance (QA) procedures that include a dosimetric pre-treatment verification of individual patient planning. This verification usually involves measuring a small volume of absolute dose with an ionization chamber and checking bi-dimensional fluency with an array of detectors. The planning technique has tri-dimensional characteristics, but no tridimensional dosimetry has been established in the clinical routine. One strategy to perform three-dimensional dosimetry is to use polymeric gels associated with magnetic resonance imaging to evaluate dose distribution. Here, we have compared the results of conventional QA procedures involving one- and two-dimensional dosimetry to the results of three-dimensional dosimetry conducted with MAGIC-f gel in 10 cases of prostate cancer IMRT planning. More specifically, we used the gamma index (3%/3mm) to compare the results of three-dimensional dosimetry to the expected dose distributions obtained with the treatment planning system. Except for one IMRT treatment plan, the gel dosimetry results agreed with the conventional quality control and provided an overview of dose distribution in the target volume.


Assuntos
Imageamento Tridimensional , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/radioterapia , Garantia da Qualidade dos Cuidados de Saúde , Radioterapia de Intensidade Modulada , Calibragem , Géis , Humanos , Imageamento por Ressonância Magnética , Masculino , Radiometria , Planejamento da Radioterapia Assistida por Computador
4.
Sci Rep ; 5: 14004, 2015 Sep 14.
Artigo em Inglês | MEDLINE | ID: mdl-26365945

RESUMO

The optical properties of core-shell nanoparticles consisting of a ZnO shell grown on Ag and Au nanoparticle cores by a solution method have been investigated. Both the ZnO/Ag and ZnO/Au particles exhibit strongly enhanced near-band-edge UV emission from the ZnO when excited at 325 nm. Furthermore, the UV intensity increases with the metal nanoparticle concentration, with 60-fold and 17-fold enhancements for the ZnO/Ag and ZnO/Au, core-shell nanoparticles respectively. Accompanying the increase in UV emission, there is a corresponding decrease in the broad band defect emission with nanoparticle concentration. Nonetheless, the broad band luminescence increases with laser power. The results are consistent with enhanced exciton emission in the ZnO shells due to coupling with surface plasmon resonance of the metal nanoparticles. Luminescence measurements during and after exposure to X-rays also exhibit enhanced UV luminescence. These observations suggest that metal nanoparticles may be suitable for enhancing optical detection of ionizing radiation.

5.
Braz. j. med. biol. res ; 48(7): 644-649, 07/2015. tab, graf
Artigo em Inglês | LILACS | ID: lil-751345

RESUMO

Radiotherapy is one of the main approaches to cure prostate cancer, and its success depends on the accuracy of dose planning. A complicating factor is the presence of a metallic prosthesis in the femur and pelvis, which is becoming more common in elderly populations. The goal of this work was to perform dose measurements to check the accuracy of radiotherapy treatment planning under these complicated conditions. To accomplish this, a scale phantom of an adult pelvic region was used with alanine dosimeters inserted in the prostate region. This phantom was irradiated according to the planned treatment under the following three conditions: with two metallic prostheses in the region of the femur head, with only one prosthesis, and without any prostheses. The combined relative standard uncertainty of dose measurement by electron spin resonance (ESR)/alanine was 5.05%, whereas the combined relative standard uncertainty of the applied dose was 3.35%, resulting in a combined relative standard uncertainty of the whole process of 6.06%. The ESR dosimetry indicated that there was no difference (P>0.05, ANOVA) in dosage between the planned dose and treatments. The results are in the range of the planned dose, within the combined relative uncertainty, demonstrating that the treatment-planning system compensates for the effects caused by the presence of femur and hip metal prostheses.


Assuntos
Adulto , Humanos , Masculino , Citocinas/sangue , Infecções por HIV/sangue , Linfoma Relacionado a AIDS/sangue , Linfoma de Células B/sangue , Linfoma de Células B/virologia , Biomarcadores Tumorais/sangue , Bissexualidade , Estudos de Casos e Controles , Infecções por HIV/imunologia , Homossexualidade , Inflamação/sangue , Inflamação/imunologia , Inflamação/virologia , Ativação Linfocitária , Linfoma Relacionado a AIDS/imunologia , Linfoma de Células B/imunologia , Análise Multivariada
6.
Phys Med Biol ; 60(11): 4465-80, 2015 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-25988912

RESUMO

In this work, we aim to experimentally assess increments of dose due to nanoparticle-radiation interactions via electron spin resonance (ESR) dosimetry performed with a biological-equivalent sensitive material.We employed 2-Methyl-Alanine (2MA) in powder form to compose the radiation sensitive medium embedding gold nanoparticles (AuNPs) 5 nm in diameter. Dosimeters manufactured with 0.1% w/w of AuNPs or no nanoparticles were irradiated with clinically utilized 250 kVp orthovoltage or 6 MV linac x-rays in dosimetric conditions. Amplitude peak-to-peak (App) at the central ESR spectral line was used for dosimetry. Dose-response curves were obtained for samples with or without nanoparticles and each energy beam. Dose increments due to nanoparticles were analyzed in terms of absolute dose enhancements (DEs), calculated as App ratios for each dose/beam condition, or relative dose enhancement factors (DEFs) calculated as the slopes of the dose-response curves.Dose enhancements were observed to present an amplified behavior for small doses (between 0.1-0.5 Gy), with this effect being more prominent with the kV beam. For doses between 0.5-5 Gy, dose-independent trends were observed for both beams, stable around (2.1 ± 0.7) and (1.3 ± 0.4) for kV and MV beams, respectively. We found DEFs of (1.62 ± 0.04) or (1.27 ± 0.03) for the same beams. Additionally, we measured no interference between AuNPs and the ESR apparatus, including the excitation microwaves, the magnetic fields and the paramagnetic radicals.2MA was demonstrated to be a feasible paramagnetic radiation-sensitive material for dosimetry in the presence of AuNPs, and ESR dosimetry a powerful experimental method for further verifications of increments in nanoparticle-mediated doses of biological interest. Ultimately, gold nanoparticles can cause significant and detectable dose enhancements in biological-like samples irradiated at both kilo or megavoltage beams.


Assuntos
Espectroscopia de Ressonância de Spin Eletrônica , Nanopartículas Metálicas/efeitos da radiação , Fótons , Radiometria/métodos , Ácidos Aminoisobutíricos/química , Ácidos Aminoisobutíricos/efeitos da radiação , Ouro/química , Dosagem Radioterapêutica , Raios X
7.
Braz J Med Biol Res ; 48(7): 644-9, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26017344

RESUMO

Radiotherapy is one of the main approaches to cure prostate cancer, and its success depends on the accuracy of dose planning. A complicating factor is the presence of a metallic prosthesis in the femur and pelvis, which is becoming more common in elderly populations. The goal of this work was to perform dose measurements to check the accuracy of radiotherapy treatment planning under these complicated conditions. To accomplish this, a scale phantom of an adult pelvic region was used with alanine dosimeters inserted in the prostate region. This phantom was irradiated according to the planned treatment under the following three conditions: with two metallic prostheses in the region of the femur head, with only one prosthesis, and without any prostheses. The combined relative standard uncertainty of dose measurement by electron spin resonance (ESR)/alanine was 5.05%, whereas the combined relative standard uncertainty of the applied dose was 3.35%, resulting in a combined relative standard uncertainty of the whole process of 6.06%. The ESR dosimetry indicated that there was no difference (P>0.05, ANOVA) in dosage between the planned dose and treatments. The results are in the range of the planned dose, within the combined relative uncertainty, demonstrating that the treatment-planning system compensates for the effects caused by the presence of femur and hip metal prostheses.


Assuntos
Espectroscopia de Ressonância de Spin Eletrônica/instrumentação , Prótese de Quadril , Neoplasias da Próstata/radioterapia , Doses de Radiação , Adulto , Calibragem , Espectroscopia de Ressonância de Spin Eletrônica/métodos , Humanos , Masculino , Modelos Anatômicos , Imagens de Fantasmas , Dosagem Radioterapêutica , Reprodutibilidade dos Testes , Incerteza
9.
Food Chem ; 141(3): 1860-4, 2013 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-23870902

RESUMO

Electron spin resonance (ESR) spectra of irradiated gum Arabic with doses between 0.5 and 5 kGy were studied. A linear relationship between the absorbed dose and the intensities of the ESR spectra was observed. ESR spectra of irradiated gum Arabic showed a decay of relative concentrations of free radicals originated by radiation and the production of at least two species of free radicals with half-times: 3.3 and 125.4 h. The results of spectral simulations for these radical groups were giso=2.0046; A=1.2 mT and gx=gy=2.0062, gz=2.0025. Hydration and dehydration of irradiated gum Arabic returns the ESR spectrum to its initial state before irradiation. The results show that ESR can be used as simple and reliable method to detect irradiated gum Arabic up to 60 days after initial radiation with doses on the order of 5 kGy.


Assuntos
Espectroscopia de Ressonância de Spin Eletrônica/métodos , Goma Arábica/química , Radicais Livres/química , Raios gama , Goma Arábica/efeitos da radiação , Cinética
10.
Neuroscience ; 233: 86-94, 2013 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-23291456

RESUMO

Caffeic acid phenethyl ester (CAPE) is a botanical compound abundant in honeybees' propolis. It has anti-inflammatory, antiviral, antioxidant, immunomodulatory and antitumor properties. Its beneficial effects against neurodegenerative diseases, including Parkinson's disease, have also been suggested and some mechanisms have been proposed. Mitochondrial damage and oxidative stress are critical events in neurodegeneration. Release of cytochrome c from mitochondria to cytosol and the downstream activation of caspase-3 have been suggested as targets of the protective mechanism of CAPE. Most of the studies addressing the protective effect of CAPE have been performed in cell culture. This is the first study to demonstrate the protective effect of CAPE against the dopaminergic neuronal loss induced by 6-hydroxydopamine (6-OHDA) in rats. It also demonstrates, for the first time, the inhibitory effect of CAPE on mitochondrial permeability transition (MPT), a mediator of neuronal death that triggers cytochrome c release and caspase-3 activation. Scavenging of reactive oxygen species (ROS) and metal chelation was demonstrated in the brain-affected areas of the rats treated with 6-OHDA and CAPE. Additionally, we demonstrated that CAPE does not affect brain mitochondrial function. Based on these findings and on its ability to cross the blood-brain barrier, CAPE is a promising compound to treat Parkinson's and other neurodegenerative diseases.


Assuntos
Ácidos Cafeicos/farmacologia , Neurônios Dopaminérgicos/efeitos dos fármacos , Proteínas de Transporte da Membrana Mitocondrial/efeitos dos fármacos , Fármacos Neuroprotetores/farmacologia , Transtornos Parkinsonianos/prevenção & controle , Álcool Feniletílico/análogos & derivados , Adrenérgicos , Animais , Antioxidantes/farmacologia , Morte Celular/efeitos dos fármacos , Modelos Animais de Doenças , Sequestradores de Radicais Livres/farmacologia , Poro de Transição de Permeabilidade Mitocondrial , Oxidopamina , Transtornos Parkinsonianos/induzido quimicamente , Álcool Feniletílico/farmacologia , Ratos , Ratos Wistar
11.
Med Phys ; 39(5): 2877-84, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22559660

RESUMO

PURPOSE: This paper presents the application of MAGIC-f gel in a three-dimensional dose distribution measurement and its ability to accurately measure the dose distribution from a tomotherapy unit. METHODS: A prostate intensity-modulated radiation therapy (IMRT) irradiation was simulated in the gel phantom and the treatment was delivered by a TomoTherapy equipment. Dose distribution was evaluated by the R2 distribution measured in magnetic resonance imaging. RESULTS: A high similarity was found by overlapping of isodoses of the dose distribution measured with the gel and expected by the treatment planning system (TPS). Another analysis was done by comparing the relative absorbed dose profiles in the measured and in the expected dose distributions extracted along indicated lines of the volume and the results were also in agreement. The gamma index analysis was also applied to the data and a high pass rate was achieved (88.4% for analysis using 3%∕3 mm and of 96.5% using 4%∕4 mm). The real three-dimensional analysis compared the dose-volume histograms measured for the planning volumes and expected by the treatment planning, being the results also in good agreement by the overlapping of the curves. CONCLUSIONS: These results show that MAGIC-f gel is a promise for tridimensional dose distribution measurements.


Assuntos
Polímeros/química , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Animais , Géis , Humanos , Masculino , Neoplasias da Próstata/radioterapia , Radiometria , Software
12.
Appl Radiat Isot ; 70(3): 533-7, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22115877

RESUMO

Intensity of the 150°C thermoluminescence peak of beta-irradiated carbonated synthetic A-type hydroxyapatite is approximately 12 times higher than that of the noncarbonated material. Deconvolution of the glow curve showed that this peak is a result of a trap distribution. An attempt was made to relate this thermoluminescence peak enhanced by carbonation with the ESR signal of the CO(2)(-) radical in natural or synthetic hydroxyapatite.

13.
Radiat Res ; 176(2): 259-63, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-21631287

RESUMO

Using an experimental model and PENELOPE Monte Carlo simulations, the effects of resin and amalgam on the absorbed doses in tooth enamel were studied to evaluate the feasibility of using restored teeth in electron spin resonance (ESR) dose reconstruction. The model consisted of a phantom containing a plate of these restorative materials placed between powered enamel layers exposed to X rays and a 6°Co beam. The experimental results and simulations agreed, showing that the attenuation produced by amalgam and resin with a thickness of 1, 2, and 4 mm is similar to that produced by the enamel itself in the case of the radiation sources employed. For X rays and 6°Co γ radiation the attenuation reached almost 100% and 40%, respectively. These results show that for ESR dose reconstruction, the use of all available enamel of a tooth leads to errors in the estimated dose due to attenuation effects in both healthy and restored teeth. Thus the importance of an enamel selection from different sides of the tooth surface to apply ESR dose reconstruction in the case of a practical situation is shown.


Assuntos
Esmalte Dentário/efeitos da radiação , Restauração Dentária Permanente , Radiometria/métodos , Amálgama Dentário , Espectroscopia de Ressonância de Spin Eletrônica , Estudos de Viabilidade , Doses de Radiação , Resinas Sintéticas
14.
Artigo em Inglês | MEDLINE | ID: mdl-19964487

RESUMO

In order to improve the spatial resolution of Biosusceptometry of Alternate Current (BAC), we are suggesting the coupling of a Doppler ultrasonic transducer with the BAC system. The Doppler transducer obtains information from the vibration of ferromagnetic particles immersed in a visco-elastic medium when it is excited by an alternating magnetic field. In this case, the same magnetic particles used as contrast for susceptometric measurement also will work as contrast for the Doppler measurement. In this work, we present the characterization of the hybrid system for susceptometric and acoustic measurements simultaneously. It was observed that the susceptometric and Doppler ultrasound signal have the same profile and maximum amplitude for frequency of magnetizing field about 200 Hz. When using ferrite particles as magnetic contrast mixed with yogurt as based material, the susceptometric and Doppler measurement have sensitivity for concentration of particles as low as 1%. The sensitivity of the Doppler is dependent of the gradient of magnetic field over the sample. In this work, the magnetic field 5 cm far from the face of the transducer was 70 microT/volts.


Assuntos
Magnetismo/instrumentação , Pletismografia de Impedância/instrumentação , Transdutores , Ultrassonografia/instrumentação , Desenho Assistido por Computador , Desenho de Equipamento , Análise de Falha de Equipamento , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
15.
Phys Med Biol ; 54(1): 161-74, 2009 Jan 07.
Artigo em Inglês | MEDLINE | ID: mdl-19075356

RESUMO

Functional magnetic resonance imaging (fMRI) data analysis has been carried out recently in the framework of information theory, by means of the Shannon entropy. As a natural extension, a method based on the generalized Tsallis entropy was developed to the analysis event-related (ER-fMRI), where a brief stimulus is presented, followed by a long period of rest. The new technique aims for spatial localization neuronal activity due to a specific task. This method does not require a priori hypothesis of the hemodynamic response function (HRF) shape and the linear relation between BOLD responses with the presented task. Numerical simulations were performed so as to determine the optimal values of the Tsallis q parameter and the number of levels, L. In order to avoid undesirable divergences of the Tsallis entropy, only positive q values were studied. Results from simulated data (with L = 3) indicated that, for q = 0.8, the active brain areas are detected with the highest performance. Moreover, the method was tested for an in vivo experiment and demonstrated the ability to discriminate active brain regions that selectively responded to a bilateral motor task.


Assuntos
Entropia , Potenciais Evocados , Imageamento por Ressonância Magnética/métodos , Oxigênio/sangue , Adulto , Hemodinâmica , Humanos , Atividade Motora/fisiologia , Curva ROC , Visão Ocular/fisiologia
16.
Photochem Photobiol ; 84(3): 627-31, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18282181

RESUMO

We report an experimental and theoretical study of magnetic properties of synthetic eumelanin. The magnetization curves are determined by using both a vibrating sample magnetometer and a superconducting quantum interferometer device in an extended range of magnetic fields ranging from -10 kOe to 10 kOe at different temperatures. We find that the eumelanin magnetization can be qualitatively explained in terms of a simple model of dipolar spheres with an intrinsic magnetic moment. The latter one is experimentally measured by using X-band electron paramagnetic resonance. Our findings indicate that synthetic melanins are superparamagnetic.


Assuntos
Magnetismo , Melaninas/química , Simulação por Computador , Espectroscopia de Ressonância de Spin Eletrônica , Melaninas/síntese química , Método de Monte Carlo , Temperatura
17.
Neurogastroenterol Motil ; 19(10): 804-11, 2007 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-17883432

RESUMO

Abnormal intragastric distribution of food (IDF) and a phasic contractility in the proximal stomach have been related to dyspeptic symptoms. Thus, the behaviour of the stomach and the proximal region, in particular, continues to attract attention and demand for reliable and comfortable techniques. The aims of this study were to employ AC Biosusceptometry (ACB) and scintigraphy to evaluate IDF and gastric motor activity in humans. Fifteen healthy volunteers ingested 60 mL of yogurt containing 2 mCi of 99mTc and 4 g of ferrite. Each volunteer had gastric motility and IDF evaluated twice on separate days; on one occasion by ACB and another by scintigraphy. Digital signal processing was performed in MatLab (Mathworks Inc., Natick, MA, USA). Results were expressed as mean +/- SD. Similar results of distal accumulation time (P < 0.001) were obtained for scintigraphy (6.93 +/- 3.25 min) and for ACB (7.04 +/- 3.65 min). Fast Fourier Transform revealed two dominant frequencies (P > 0.9). Besides the well-know frequency of 3 cpm, our results showed identical frequencies in proximal stomach recordings (P < 0.001) for scintigraphic (1.01 +/- 0.01 cpm) and ACB (0.98 +/- 0.06 cpm). In summary, our data showed that scintigraphy and ACB are promising techniques to evaluate several aspects of gastric motility. Moreover, ACB is non-invasive, radiation-free and deserves the same importance as conventional methods for this kind of analysis.


Assuntos
Esvaziamento Gástrico/fisiologia , Motilidade Gastrointestinal/fisiologia , Cintilografia/métodos , Estômago/diagnóstico por imagem , Estômago/fisiologia , Adulto , Feminino , Alimentos , Humanos , Masculino , Sensibilidade e Especificidade , Coloide de Enxofre Marcado com Tecnécio Tc 99m
18.
Physiol Meas ; 28(9): 1029-44, 2007 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-17827651

RESUMO

The detection of the basic electric rhythm (BER), composed of a 3 cycles min(-1) oscillation, can be performed using SQUID magnetometers. However, the electric response activity (ERA), which is generated when the stomach is performing a mechanical activity, was detected mainly by invasive electrical measurements and only recently was one report published describing its detection by magnetic measurements. This study was performed with the aim of detecting the ERA noninvasively after a meal. MGG recordings were made with a 74-channel first-order gradiometer (Magnes II, biomagnetic technologies) housed in a shielded room. Seven nonsymptomatic volunteers were measured in the study. Initially a 10 min recording was performed with the subject in the fasted state. A 250 kcal meal was given to the subject without moving out of the magnetometers and two epochs of 10 min each were acquired. The signals were processed to remove cardiac interference by an algorithm based on a variation of independent component analysis (ICA), then autoregressive and wavelet analysis was performed. Preliminary results have shown that there is an increase in the signal power at higher frequencies around (0.6 Hz-1.3 Hz) usually associated with the basic electric rhythm. The center of the frequency band and its width varied from subject to subject, demonstrating the importance of pre-prandial acquisition as a control. Another interesting finding was an increase in power after about 5 min of meal ingestion. This period roughly agrees with the lag phase of gastric emptying, measured by scintigraphy and other techniques. We confirm that MGG can detect the electric response activity in normal volunteers. Further improvements in signal processing and standardization of signal acquisition are necessary to ascertain its possible use in clinical situations.


Assuntos
Potenciais de Ação/fisiologia , Algoritmos , Diagnóstico por Computador/métodos , Eletrofisiologia/métodos , Motilidade Gastrointestinal/fisiologia , Magnetismo , Estômago/fisiologia , Simulação por Computador , Interpretação Estatística de Dados , Humanos , Modelos Biológicos , Músculo Liso/fisiologia , Análise de Componente Principal
19.
Neurogastroenterol Motil ; 18(12): 1078-83, 2006 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-17109691

RESUMO

Motility patterns play a major role in human colonic functions; however, its physiological significance is poorly understood. Several studies have been introducing the Alternating Current Biosusceptometry (ACB) as a valuable tool in gastroenterology and pharmaceutical research. Using gold standard techniques, great effort has been made to validate ACB as a method for measuring gastrointestinal motility in humans and animals. The aim of this study was to evaluate caecocolonic motility and its response to a meal in healthy volunteers. The results showed a dominant frequency of 3.17 +/- 0.13 cycles per minute (mean +/- SD) that remained unchanged even after a standardized meal (P > 0.01). The colonic response to a meal was recorded as a considerable increase in amplitude, reflected by motility index (P < 0.01) and was observed for all the volunteers. The caecocolonic motility could be assessed by the ACB providing new insights into physiological patterns of motility. Moreover, the method is non-invasive, radiation-free, cost-effective and independent of bowel preparation.


Assuntos
Ceco/fisiologia , Colo/fisiologia , Motilidade Gastrointestinal/fisiologia , Magnetismo/instrumentação , Adulto , Ingestão de Alimentos , Análise de Fourier , Humanos
20.
Radiat Prot Dosimetry ; 119(1-4): 446-9, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-16597696

RESUMO

The dating of fossil teeth of an ancient goat (Nesogoral melonii) using the electron spin resonance (ESR) technique is reported. This animal was found in the fossiliferous site at Orosei (Nuoro, Sardinia, Italy) and was endemic in the region. Molar teeth were cleaned and enamel was completely removed from dentine. Enamel was irradiated with a 60Co gamma source and measured with an ESR spectrometer (X-band) to obtain the signal vs. dose curve and fitted with an exponential function. The archeological dose obtained by the fitting was 211 +/- 34 Gy. Uranium and thorium concentrations were determined by neutron activation analysis. With the software ROSY the age estimates were 195 +/- 30 ky for early uptake, 247 +/- 40 ky for linear uptake and 243 +/- 40 ky for a combination of uptake processes.


Assuntos
Espectroscopia de Ressonância de Spin Eletrônica/métodos , Odontologia Legal/métodos , Dente/química , Dente/fisiologia , Animais , Cabras , Itália , Paleontologia/métodos