Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-38728067

RESUMO

BACKGROUND: Lesion durability and transmurality are crucial for successful radiofrequency (RF) ablation. This study provides a model of real-time RF lesion visualization and insights into the role of underlying parameters, as local impedance (LI). METHODS: A force-sensing, LI-sensing catheter was used for lesion creation in an ex vivo model involving cross-sections of porcine cardiac preparations. During 60 s of RF application, one measurement per second was performed regarding lesion size and available ablation parameters. In total, 1847 measurements from n = 36 lesions were performed. Power (20-50 W) and contact force (1-5 g, 10-15 g, 20-25 g) were systematically alternated. RESULTS: Lesion formation was most prominent in the first seconds of RF application during which nonlinear lesion growth was observed (max. 1.08 mm/s for lesion depth and 2.71 mm/s for lesion diameter). Power levels determined the extent of lesion formation in the early phase. After 20 s, lesion size growth velocity approaches 0.1 mm/s at all power levels. LI changes were also highest in the first seconds (up to - 12 Ω/s) and decreased to less than - 0.1Ω/s after prolonged application. CONCLUSION: Lesion formation in irrigated RF ablation is a nonlinear process. Final lesion size resulting from an RF application is mainly influenced by high rates of lesion growth in the first seconds of ablation. LI seems to be a good surrogate for differentiating changes in lesion formation.

2.
Artigo em Inglês | MEDLINE | ID: mdl-38775921

RESUMO

BACKGROUND: Pulse field ablation (PFA) is a novel catheter ablation technology with potential safety benefits due to its tissue selectivity. It has the potential to directly damage or interact with the functionality of cardiac implantable electronic devices (CIEDs) in the form of electromagnetic interference (EMI). The aim of our study was to assess the impact of PFA on CIEDs. METHODS: PFA lesions (45 per CIED) were applied from the Farapulse system to CIEDs (< 5 cm from the lead tip and < 15 cm from the generator). All devices were checked before and after PFA application for proper sensing and pacing functionality as well as for integrity of shock circuits in ICDs using a heart simulator. Moreover, devices were then interrogated for any spontaneous reprogramming, mode switching or other EMI effects. RESULTS: In total, 44 CIEDs were tested (16 pacemaker, 21 ICDs, 7 CRT-P/D) with 1980 PFA applications. There was no change in device settings, functionality and electrical parameters, and there was no macroscopic damage to the devices. The risk of damage to the electric components or leads on a patient-based analysis is 0/44 (95% CI 0-8%) and on a PFA pulse-based analysis is 0/1980 (95% CI 0-0.2%). Clinically relevant EMI appeared with oversensing and pacing inhibition but not tachycardia detection. CONCLUSIONS: Bipolar PFA appears safe and does not result in damage to CIEDs or leads. Clinically relevant EMI does occur, but appropriate peri-procedural programming may mitigate this. In vivo studies are needed to confirm our findings.

3.
Clin Res Cardiol ; 2024 Jan 23.
Artigo em Inglês | MEDLINE | ID: mdl-38261026

RESUMO

BACKGROUND: Data regarding uninterrupted oral anticoagulation in patients with chronic kidney disease (CKD) during catheter ablation for left atrial arrhythmias is limited. This study aimed to evaluate the safety and efficacy of periprocedural uninterrupted direct oral anticoagulants (DOAC) compared with uninterrupted phenprocoumon in patients with CKD undergoing left atrial catheter ablation. METHODS AND RESULTS: We conducted a retrospective single-center study of patients who underwent left atrial catheter ablation between 2016 and 2019 with underlying chronic kidney disease (glomerular filtration rate (GFR) between 15 and 45 ml/min). The primary objective of this study was to investigate whether direct oral anticoagulant (DOAC) therapy or warfarin presents a superior safety profile in patients with chronic kidney disease (CKD) undergoing left atrial catheter ablation. We compared periprocedural complications (arteriovenous fistula, aneurysm, significant hematoma (> 5 cm)) and/or bleeding (drop in hemoglobin of >2 g/dl, pericardial effusion, retroperitoneal bleeding, other bleeding, stroke) between patients receiving either uninterrupted DOAC or warfarin therapy. Secondary analysis included patient baseline characteristics as well as procedural data. A total of 188 patients (female n = 108 (57%), mean age 75.3 ± 8.1 years, mean GFR 36.8 ± 6 ml/min) were included in this study. Underlying arrhythmias were atrial fibrillation (n = 104, 55.3%) and atypical atrial flutter (n = 84, 44.7%). Of these, n = 132 patients (70%) were under a DOAC medication, and n = 56 (30%) were under phenprocoumon. Major groin complications including pseudoaneurysm and/or AV fistula occurred in 8.9% of patients in the phenprocoumon group vs. 11.3% of patients in the DOAC group, which was not statistically significant (p = 0.62). Incidence of cardiac tamponade (2.3% vs. 0%; p = 0.55) and stroke (0% vs. 0%) were low in both DOAC and phenprocoumon groups with similar post-procedural drops in hemoglobin levels (1.1±1 g/dl vs 1.1±0.9 g/dl; p = 0.71). CONCLUSION: The type of anticoagulation had no significant influence on bleeding or thromboembolic events as well as groin complications in this retrospective study. Despite observing an increased rate of groin complications, the uninterrupted use of DOAC or phenprocoumon during left atrial catheter ablation in patients with CKD appears to be feasible and effective.

4.
J Cardiovasc Electrophysiol ; 35(3): 406-414, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38197476

RESUMO

INTRODUCTION: Despite advanced ablation strategies and major technological improvements, treatment of persistent atrial fibrillation (AF) remains challenging and the underlying pathophysiology is not fully understood. This study analyzed the multiple procedure outcome and safety of catheter ablation of spatiotemporal dispersions (DISPERS) detected by artificial intelligence (AI)-guided software in patients with long-standing persistent AF. METHODS AND RESULTS: The Volta VX1 software was used for 50 consecutive patients undergoing catheter ablation for persistent AF. First, high-density mapping (78% biatrial) with a multipolar mapping catheter was performed. In addition to pulmonary vein isolation (PVI), ablation of DISPERS was performed aiming at homogenizing, dissecting, isolating, or connecting DISPERS areas to nonconducting anatomical structures. Follow-up contained regular visits at our outpatient clinic at 1, 3, 6, and 12 months including 7-day Holter electrocardiograms. Patients were mainly suffering from long-standing persistent AF (mean AF duration 50.30 ± 54.28 months). Following PVI, ablation of left atrial and right atrial DISPERS areas led to AF cycle length prolongation (mean of 162.0 ± 16.6 to 202.2 ± 21.6 ms after) and AF termination to atrial tachycardia (AT) or sinus rhythm (SR) in 12 patients (24%). No stroke or pericardial effusion occurred; major groin complications (pseudoaneurysm n = 1, atrioventricular fistula n = 1) were detected in two patients. After a blanking period of 6 weeks, recurrence of any atrial arrhythmia was documented in 26 patients (52%). The majority of patients presented with organized AT (n = 15) while AF was present in n = 9 patients and AT/AF was observed in n = 2 patients. Twenty-two patients underwent reablation. During a mean follow-up of 363.14 ± 187.42 days and after an average of 1.46 ± 0.68 procedures, 82% of patients remained in stable SR. CONCLUSION: DISPERS-guided ablation using machine learning software (the Volta VX1 software) in addition to PVI in long-standing persistent AF ablation resulted in high long-term success rates regarding AF and AT elimination. Most arrhythmia recurrences were reentrant AT. After a total of 1.46 ± 0.68 procedures, freedom from AF/AT was 82%. Despite prolonged procedure times complication rates were low. Randomized studies are necessary to evaluate long-term efficacy of dispersion-guided ablation using AI.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Taquicardia Supraventricular , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Inteligência Artificial , Resultado do Tratamento , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Veias Pulmonares/cirurgia , Recidiva
5.
J Cardiovasc Electrophysiol ; 35(2): 317-327, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38105426

RESUMO

INTRODUCTION: Pulmonary vein isolation (PVI) using radiofrequency ablation (RFA) is an established treatment strategy for atrial fibrillation (AF). To improve PVI efficacy and safety, high-power short-duration (HPSD) ablation and pulsed-field ablation (PFA) were recently introduced into clinical practice. This study aimed to determine the extent of myocardial injury and systemic inflammation following PFA, HPSD, and standard RFA using established biomarkers. METHODS: We included 179 patients with paroxysmal AF receiving first-time PVI with different ablation technologies: standard RFA (30-40 W/20-30 s, n = 52), power-controlled HPSD (70 W/5-7 s, n = 60), temperature-controlled HPSD (90 W/4 s, n = 32), and PFA (biphasic, bipolar waveform, n = 35). High-sensitivity cardiac troponin T (hs-cTnT), creatine kinase (CK), CK MB isoform (CK-MB), and white blood cell (WBC) count were determined before and after ablation. RESULTS: Baseline characteristics were well-balanced between groups (age 63.1 ± 10.3 years, 61.5% male). Postablation hs-cTnT release was significantly higher with PFA (1469.3 ± 495.0 ng/L), HPSD-70W (1322.3 ± 510.6 ng/L), and HPSD-90W (1441.2 ± 409.9 ng/L) than with standard RFA (1045.9 ± 369.7 ng/L; p < .001). CK and CK-MB release was increased with PFA by 3.4-fold and 5.8-fold, respectively, as compared to standard RFA (p < .001). PFA was associated with the lowest elevation in WBC (Δ1.5 ± 1.5 × 109 /L), as compared to standard RFA (Δ3.8 ± 2.5 × 109 /L, p < .001), HPSD-70W (Δ2.7 ± 1.7 × 109 /L, p = .037), and HPSD-90W (Δ3.6 ± 2.5 × 109 /L, p < .001). CONCLUSION: Among the four investigated ablation technologies, PFA was associated with the highest myocardial injury and the lowest inflammatory reaction.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Traumatismos Cardíacos , Veias Pulmonares , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Feminino , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Creatina Quinase Forma MB , Inflamação/diagnóstico , Veias Pulmonares/cirurgia , Troponina T , Ablação por Cateter/efeitos adversos , Resultado do Tratamento , Recidiva
7.
J Clin Med ; 12(20)2023 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-37892670

RESUMO

BACKGROUND: The aim of this study was to assess long-term efficacy and safety of empirical slow pathway (ESP) ablation in pediatric and adult patients with a special interest in patients without dual AV nodal physiology (DAVNP). METHODS: A retrospective single-center review of patients who underwent ESP ablation between December 2014 and September 2022 was performed. Follow-up included telephone communication, letter questionnaire and outpatient presentation. Recurrence was based on typical symptoms. RESULTS: 115 patients aged 6-81 years (median age 36.3 years, 59.1% female; 26 pts < 18 years) were included. A typical history was present in all patients (100%), an ECG documentation of narrow complex tachycardia in 97 patients (84%). Patients were divided into three groups: Group 1 without DAVNP (n = 23), Group 2 with AH jump (n = 30) and Group 3 with AH jump and at least one AV nodal echo beat (n = 62). No permanent AV block was observed. During a median follow-up of 23.6 ± 22.7 months, symptom recurrence occurred in 7/115 patients (6.1%) with no significant difference between the groups (p = 0.73, log-rank test). Symptom recurrence occurred significantly more often in patients without (5/18 patients; 27%) as compared to patients with ECG documentation (2/97 patients; 2.1%; p = 0.025). No correlation between age and success rate was found (p > 0.1). CONCLUSIONS: ESP ablation is effective and safe in patients with non-inducible AVNRT. Overall, recurrence of symptoms during long-term follow-up is low, even if no DAVNP is present. Tachycardia documentation before the EP study leads to a significantly lower recurrence rate following ESP ablation.

8.
J Clin Med ; 12(15)2023 Jul 26.
Artigo em Inglês | MEDLINE | ID: mdl-37568301

RESUMO

BACKGROUND: The demand for transvenous lead extraction (TLE) has increased. In line with this, the safety of such procedures has also increased. Traditionally, TLE is performed under resource-intensive general anaesthesia. This study aims to evaluate the safety and outcomes of Cardiologist-lead deep sedation for TLE. METHODS: We retrospectively analysed 328 TLE procedures performed under deep sedation from 2016 to 2019. TLE procedures were performed by experienced electrophysiologists. Sedation was administered by a specifically trained cardiologist (bolus midazolam/fentanyl and propofol infusion). Procedural sedation data including blood pressure, medication administration and sedation time were collected. Complications related to sedation and the operative component of the procedure were analysed retrospectively. RESULTS: The sedation-associated complication rate during TLE was 22.0%. The most common complication (75% of complications) was hypotension requiring noradrenaline, followed by bradycardia requiring atropine (13% of complications). Additionally, the unplanned presence of an anaesthesiologist was needed in one case (0.3%). Deep sedation was achieved with midazolam (mean dose 42.9 ± 26.5 µg/kg), fentanyl (mean dose 0.4 ± 0.6 µg/kg) and propofol (mean dose 3.5 ± 1.2 mg/kg/h). There was no difference in medication dosage between those with a sedation-associated complication and those without. Sedation-associated complications appeared significantly more in patients with reduced LVEF (p = 0.01), renal impairment (p = 0.01) and a higher American Society of Anaesthesiologists (ASA) class (p = 0.01). CONCLUSION: Deep sedation for TLE can be safely performed by a specifically trained cardiologist, with a transition to general anaesthesia required in only 0.3% of cases. We continue to recommend the on-call availability of an anaesthesiologist and cardiac surgeon in case of major complications.

9.
Pacing Clin Electrophysiol ; 46(10): 1170-1181, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37616376

RESUMO

BACKGROUND: The influence of power, duration and contact force (CF) on radiofrequency (RF) lesion formation is well known, whereas data on local impedance (LI) and electrode-tissue-coverage (ETC) is scarce. The objective was to investigate their effect on lesion formation in an ex vivo model. METHODS AND RESULTS: An ex vivo model was developed utilizing cross-sections of porcine heart preparations and a force-sensing, LI-measuring catheter. N = 72 lesion were created systematically varying ETC (minor/full), CF (1-5 g, 10-15 g, 20-25 g) and power (20 W, 30 W, 40 W, 50 W). In minor ETC, the distal tip of the catheter was in electric contact with the tissue, in full ETC the whole catheter tip was embedded within the tissue. Lesion size and all parameters were measured once per second (n = 3320). LI correlated strongly with lesion depth (r = -0.742 for ΔLI; r = 0.781 for %LI-drop). Lesions in full ETC were significantly wider and deeper compared to minor ETC (p < .001) and steam pops were more likely. Baseline LI, ΔLI, and %LI-drop were significantly higher in full ETC (p < .001). In lesions resulting in steam pops, baseline LI, and ΔLI were significantly higher. The influence of CF on lesion size was higher in minor ETC than in full ETC. CONCLUSIONS: ETC is a main determinant of lesion size and occurrence of steam pops. Baseline LI and LI-drop are useful surrogate parameters for real-time assessment of ETC and ΔLI correlates strongly with lesion size.


Assuntos
Ablação por Cateter , Vapor , Suínos , Animais , Impedância Elétrica , Ablação por Cateter/métodos , Eletrodos
10.
Europace ; 25(5)2023 05 19.
Artigo em Inglês | MEDLINE | ID: mdl-37067822

RESUMO

AIMS: Battery electric vehicle (BEV) sales and use are rapidly expanding. Battery electric vehicles, along with their charging stations, are a potential source of electromagnetic interference (EMI) for patients with cardiac implantable electronic devices (CIEDs). The new 'high-power' charging stations have the potential to create strong electromagnetic fields and induce EMI in CIEDs, and their safety has not been evaluated. METHODS AND RESULTS: A total of 130 CIED patients performed 561 charges of four BEVs and a test vehicle (350 kW charge capacity) using high-power charging stations under continuous 6-lead electrocardiogram monitoring. The charging cable was placed directly over the CIED, and devices were programmed to maximize the chance of EMI detection. Cardiac implantable electronic devices were re-interrogated after patients charged all BEVs and the test vehicle for evidence of EMI. There were no incidences of EMI, specifically no over-sensing, pacing inhibition, inappropriate tachycardia detection, mode switching, or spontaneous reprogramming. The risk of EMI on a patient-based analysis is 0/130 [95% confidence interval (CI) 0%-2%], and the risk of EMI on a charge-based analysis is 0/561 (95% CI 0%-0.6%). The effective magnetic field along the charging cable was 38.65 µT and at the charging station was 77.9 µT. CONCLUSIONS: The use of electric cars with high-power chargers by patients with cardiac devices appears to be safe with no evidence of clinically relevant EMI. Reasonable caution, by minimizing the time spent in close proximity with the charging cables, is still advised as the occurrence of very rare events cannot be excluded from our results.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Humanos , Campos Eletromagnéticos/efeitos adversos , Fontes de Energia Elétrica , Coração
11.
Europace ; 25(2): 408-416, 2023 02 16.
Artigo em Inglês | MEDLINE | ID: mdl-36504120

RESUMO

AIMS: This retrospective study sought to compare complication rates and efficacy of power-controlled very high-power short-duration (vHPSD) and conventional catheter ablation in a large cohort of patients with atrial fibrillation (AF). METHODS AND RESULTS: We analyzed 1115 consecutive patients with AF (38.7% paroxysmal, 61.3% persistent) who received first-time catheter ablation at our centre from 2015 to 2021. Circumferential pulmonary vein isolation ± additional substrate ablation using an irrigated-tip catheter was performed with vHPSD (70 W/5-7 s or 60 W/7-10 s) in 574 patients and with conventional power (30-35 W/15-30 s) in 541 patients. Baseline characteristics were well-balanced between groups (mean age 65.1 ± 11.2 years, 63.4% male). The 30-day incidence of cardiac tamponade [2/574 (0.35%) vs. 1/541 (0.18%), P = 0.598], pericardial effusion ≥ 10 mm [2/574 (0.35%) vs. 1/541 (0.18%), P = 0.598] and transient ischaemic attack [1/574 (0.17%) vs. 2/541 (0.37%), P = 0.529] was not significantly different between vHPSD and conventional ablation. No stroke, atrio-esophageal fistula, cardiac arrest or death occurred. Procedure (122.2 ± 46.8 min vs. 155.0 ± 50.5 min, P < 0.001), radiofrequency (22.4 ± 19.3 min vs. 52.9 ± 22.0 min, P < 0.001), and fluoroscopy (8.1 ± 7.2 vs. 9.2 ± 7.4, P = 0.016) duration were significantly shorter in the vHPSD group. At 12 months follow-up, freedom of any atrial arrhythmia was 44.1% vs. 34.2% (P = 0.010) in persistent AF and 78.1% vs. 70.2% in paroxysmal AF (P = 0.068). CONCLUSION: vHPSD ablation is as safe as conventional ablation and is associated with an improved long-term efficacy in persistent AF.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Feminino , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Estudos Retrospectivos , Resultado do Tratamento , Catéteres , Veias Pulmonares/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos
12.
J Clin Med ; 11(22)2022 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-36431243

RESUMO

Background: Femoral vascular access using the standard anatomic landmark-guided method is often limited by peripheral artery disease and obesity. We investigated the effect of ultrasound-guided vascular puncture (UGVP) on the rate of vascular complications in patients undergoing catheter ablation for atrial or ventricular arrhythmias. Methods: The data of 479 patients (59% male, mean age 68 years ± 11 years) undergoing catheter ablation for left atrial (n = 426; 89%), right atrial (n = 28; 6%) or ventricular arrhythmias (n = 28; 6%) were analyzed. All patients were on uninterrupted oral anticoagulants and heparin was administered intravenously during the procedure. Femoral access complications were compared between patients undergoing UGVP (n = 320; 67%) and patients undergoing a conventional approach (n = 159; 33%). Complication rates were also compared between patients with a BMI of >30 kg/m2 (n = 136) and patients with a BMI < 30 kg/m2 (n = 343). Results: Total vascular access complications including mild hematomas were n = 37 (7.7%). In the conventional group n = 17 (10.7%) and in the ultrasound (US) group n = 20 (6.3%) total vascular access complications occurred (OR 0.557, 95% CI 0.283−1.096). UGVP significantly reduced the risk of hematoma > 5 cm (OR 0.382, 95% CI 0.148, 0.988) or pseudoaneurysm (OR 0.160, 95% CI 0.032, 0.804). There was no significant difference between the groups regarding retroperitoneal hematomas or AV fistulas (p > 0.05). In patients with BMI > 30 kg/m2, UGVP led to a highly relevant reduction in the risk of total vascular access complications (OR 0.138, 95% CI 0.027, 0.659), hematomas > 5 cm (OR 0.051, 95% CI 0.000, 0.466) and pseudoaneurysms (OR 0.051, 95% CI 0.000, 0.466). Conclusion: UGVP significantly reduces vascular access complications. Patients with a BMI > 30 kg/m2 seem to particularly profit from a UGVP approach.

13.
Heart Rhythm O2 ; 3(3): 288-294, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35734291

RESUMO

Background: Catheter ablation for atrial fibrillation (AF) or left atrial tachycardia is well established. To avoid body movement and pain, sedative and analgesic agents are used. Objective: The aim was to investigate safety of sedation/anti-pain protocol administered by electrophysiology (EP) staff. Methods: A total of 3211 consecutive patients (61% male) undergoing left atrial ablation for paroxysmal AF (37.1%), persistent AF (35.3%) or left atrial tachycardia (27.6%) were included. Midazolam, fentanyl, and propofol were administered by EP staff. In case of respiratory depression, endotracheal intubation (eIT) or noninvasive ventilation (NIV) was implemented. Risk factors for eIT or NIV were analyzed. Results: Mean doses of propofol, midazolam, and fentanyl were 33.7 ± 16.7 mg, 3 ± 11.1 mg, and 0.16 ± 2.2 mg, respectively. Norepinephrine was administered in 396 of 3211 patients (12.3%) because of blood pressure drop (mean arterial pressure <60 mm Hg). NIV was necessary in 47 patients (1.5%) and eIT in 1 patient (0.03%). Procedure duration, high body mass index (BMI), high CHADS2-VASC2 score, high age, low glomerular filtration rate, diabetes mellitus, and low baseline oxygen saturation were associated with NIV or eIT. The only independent predictor for NIV/eIT was high BMI (>30.1 ± 9.0 kg/m2). Therefore, patients with a BMI of ≥30 had a 40% higher risk for the need of NIV/eIT during the procedure in our study. Conclusion: Sedation/anti-pain control including midazolam, propofol, and fentanyl administered by EP staff is safe, with only 1.53% requirement of NIV/eIT. High BMI (>30 kg/m2) emerged as an independent predictor for eIT/NIV.

14.
Am J Cardiol ; 176: 51-57, 2022 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-35613955

RESUMO

The rate of transvenous lead extraction (TLE) is increasing, with an increasing rate of complex devices being implanted. TLE is now a routine part of cardiac device management and up-to-date data on the safety and efficacy of TLE with modern tools and techniques is essential to management decisions regarding noninfectious indications for lead extraction. We present a contemporary, prospective review of TLE at our high-volume cardiac center. All patients who underwent TLE from June 2016 to June 2019 were enrolled in our local database, and baseline clinical data, procedural information, and outcome data were collected. In total, 561 leads were explanted (n = 153) or extracted (n = 408) from 341 patients over the study period. Patients were predominantly male (71%), with a mean age of 65 ± 17 years. The most common indication for lead removal was lead failure (45.2%, n = 154), followed by infection of the pocket or device (29.3%, n = 100). In total, complete success was achieved in 96.4% (n = 541) leads, clinical success in a further 2.1% (n = 12), and failure only in 1.4% (n = 8). There was an overall complication rate of 0.9% (3/341) for major complications and 1.5% (5/341) for minor complications. There were no deaths. In conclusion, our data suggest that there are ongoing improvements in the safety profile and success rates of lead extraction undertaken by experienced operators. The major complication rate now is <1%.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Idoso , Idoso de 80 Anos ou mais , Remoção de Dispositivo/métodos , Falha de Equipamento , Feminino , Humanos , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Estudos Retrospectivos , Resultado do Tratamento
15.
J Interv Card Electrophysiol ; 64(2): 417-426, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34373981

RESUMO

BACKGROUND: Complex ablation for persistent atrial fibrillation (AF) aims to modify the arrhythmogenic substrates to become incapable to perpetuate the arrhythmia. Ablation-associated determinants of atrial tachycardia (AT) rather than AF recurrences are unknown. The aim of the study was to evaluate the association between the type of arrhythmia recurrence and electrophysiological findings during redo procedures. METHODS: A total number of 384 consecutive patients with persistent AF underwent complex ablation consisting of PV isolation (PVI), biatrial electrogram-guided ablation, and linear ablation with the desired procedural endpoint of AF termination. Electrophysiological findings during redo procedures and its relation to AR type are the subject of this study. RESULTS: Overall, 177 (46%) patients underwent a second procedure. Patients with AT recurrences had significantly more often persistent PVI (47 vs. 25%; P = 0.002). Moreover, a higher number of recovered PVs were associated with AF recurrence (3 PVs recovered, AF = 16.1% vs. AT = 5.2%; P = 0.02; 4 PVs recovered, AF = 18.5% vs. AT = 6.3%; P = 0.01), regardless of the extent of substrate ablation during the first procedure. CONCLUSIONS: Durable PV isolation but not the extent of atrial substrate ablation determines the type of arrhythmia recurrence. Thus, the PVs may represent dominant perpetuators (and not only triggers) of persistent AF even in the presence of a significantly modified atrial substrate.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Taquicardia Supraventricular , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Humanos , Veias Pulmonares/cirurgia , Recidiva , Taquicardia Supraventricular/cirurgia , Resultado do Tratamento
16.
J Cardiovasc Electrophysiol ; 32(6): 1594-1599, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33928696

RESUMO

BACKGROUND: Steam pops are a rare complication associated with radiofrequency (RF) ablation and are hard to predict. The aim of this study was to assess the influence of coverage between the RF ablation electrode and cardiac tissue on steam pop incidence and lesion size. METHODS AND RESULTS: An ex vivo model using porcine cardiac preparations and contact force sensing catheters was designed to perform RF ablations at different coverage levels between the RF electrode and cardiac tissue. During coverage level I, only the distal part of the ablation electrode was in contact with tissue. During coverage level II half of the ablation electrode, and during coverage level III the entire ablation electrode was embedded in tissue. RF applications (n = 60) at different coverage levels I-III were systematically performed using the same standardized ablation protocol. Ablations during coverage level III resulted in a significantly higher rate of steam pops (100%) when compared to ablations during coverage level II (10%) and coverage level I (0%), log rank p < .001. Coverage level I ablations resulted in significantly smaller lesion depths, diameters, and impedance drops when compared to higher coverage level ablations, p < .001. In the controlled ex vivo model, there was no difference in applied contact force or energy between different coverage levels. CONCLUSIONS: The level of coverage between RF electrode, cardiac tissue, and the surrounding fluid significantly influenced the incidence of steam pops in an ex vivo setup. Larger coverage between RF electrode and tissue resulted in significantly larger lesion dimensions.


Assuntos
Ablação por Cateter , Ablação por Radiofrequência , Animais , Ablação por Cateter/efeitos adversos , Eletrodos , Desenho de Equipamento , Incidência , Vapor , Suínos
17.
J Cardiovasc Electrophysiol ; 30(7): 1026-1035, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-30977168

RESUMO

INTRODUCTION: Procedural atrial fibrillation (AF) termination is considered as a predictor of long-term success after catheter ablation for persistent AF (persAF). However, some patients remain free of arrhythmia recurrences despite failure to achieve AF termination. The objective of this study was to assess long-term outcome and prognostic factors in patients undergoing complex ablation without procedural AF termination. METHODS AND RESULTS: This study comprised 419 patients (63.8 ± 10.2 years, 63.4% male) undergoing complex ablation for persAF. Patients without procedural AF termination (n = 137, 64.2 ± 9.7 years, 63.5% male) were categorized into patients who remained in sinus rhythm (SR) in long-term outcome (SR-group) and patients with recurrence of AF or atrial tachycardia (AT) (AR-group). During a follow-up (FU) of 19.6 ± 14.6 months, the SR-group consisted of 65 (47.5%) and the AR-group of 69 (50.4%) patients. Three patients (2.2%) were lost to FU. Left atrial appendage (LAA) flow velocity and left atrium volume index (LAVI) could be identified as predictors for long-term success. LAA flow velocity and baseline AF cycle length (AFCL) were significantly associated with the type of arrhythmia recurrence (AF vs AT), ie, higher values of both are predictive for AT rather than AF recurrences. Patients with a LAVI < 34.4 mL/m² and significant AFCL increase during the ablation procedure had rather AT than AF recurrences. CONCLUSION: Patients with an arrhythmia-free outcome despite failure of procedural AF termination during complex ablation for persAF are characterized by specific morphological and functional properties that are easy to obtain.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter , Potenciais de Ação , Idoso , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/fisiopatologia , Função do Átrio Esquerdo , Ablação por Cateter/efeitos adversos , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Intervalo Livre de Progressão , Recidiva , Fatores de Risco , Taquicardia Supraventricular/etiologia , Taquicardia Supraventricular/fisiopatologia , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...