Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Sensors (Basel) ; 20(5)2020 Mar 06.
Artigo em Inglês | MEDLINE | ID: mdl-32155699

RESUMO

Love wave sensors with silver-modified polypyrrole nanoparticles are developed in this work. These systems prove functional at room temperature with enhanced response, sensitivity and response time, as compared to other state-of-the-art surface acoustic wave (SAW) sensors, towards volatile organic compounds (VOCs). Results demonstrate the monitoring of hundreds of ppb of compounds such as acetone, ethanol and toluene with low estimated limits of detection (~3 ppb for acetone). These results are attributed to the use of silver-modified polypyrrole as a second guiding/sensitive layer in the Love wave sensor structure, which provides further chemically active sites for the gas-solid interactions. The sensing of low VOCs concentrations by micro sensing elements as those presented here could be beneficial in future systems for air quality control, food quality control or disease diagnosis via exhaled breath as the limits of detection obtained are within those required in these applications.


Assuntos
Técnicas Biossensoriais/instrumentação , Nanopartículas/química , Polímeros/química , Pirróis/química , Prata/química , Compostos Orgânicos Voláteis/análise , Calibragem , Eletricidade , Gases/química , Nanopartículas/ultraestrutura
2.
Biosensors (Basel) ; 9(1)2018 Dec 26.
Artigo em Inglês | MEDLINE | ID: mdl-30587840

RESUMO

In the present work, a novel, portable and innovative eNose composed of a surface acoustic wave (SAW) sensor array based on zeolitic imidazolate frameworks, ZIF-8 and ZIF-67 nanocrystals (pure and combined with gold nanoparticles), as sensitive layers has been tested as a non-invasive system to detect different disease markers, such as acetone, ethanol and ammonia, related to the diagnosis and control of diabetes mellitus through exhaled breath. The sensors have been prepared by spin coating, achieving continuous sensitive layers at the surface of the SAW device. Low concentrations (5 ppm, 10 ppm and 25 ppm) of the marker analytes were measured, obtaining high sensitivities, good reproducibility, short time response and fast signal recovery.


Assuntos
Testes Respiratórios , Diabetes Mellitus/diagnóstico , Diabetes Mellitus/metabolismo , Nariz Eletrônico , Nanopartículas/química , Som , Zeolitas/química , Acetona/análise , Amônia/análise , Biomarcadores/análise , Etanol/análise , Humanos , Sensibilidade e Especificidade , Propriedades de Superfície