Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Plast Reconstr Aesthet Surg ; 88: 196-207, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37988971

RESUMO

BACKGROUND: The recovery of the spontaneous smile has become a primary focus in facial reanimation surgery and its major determinant is the selected neurotizer. We aimed to compare the spontaneity outcomes of the most preferred neurotization methods in free functional muscle transfer for long-standing facial paralysis. METHODS: The Embase, Ovid Medline, and PubMed databases were queried with 21 keywords. All clinical studies from the last 20 years reporting the postoperative spontaneity rate for specified neurotization strategies [cross-face nerve graft (CFNG), contralateral facial nerve (CLFN), motor nerve to the masseter (MNM), and dual innervation (DI)] were included. A meta-analysis of prevalence was performed using Freeman-Tukey double arcsine transformation, I2 statistic, and generic inverse variance with a random-effects model. Risk Of Bias In Non-randomized Studies of Interventions and Newcastle-Ottawa scale were used to assess bias and study quality. RESULTS: The literature search produced 2613 results and 473 unique citations for facial reanimation. Twenty-nine studies including 2046 patients were included in the systematic review. A meta-analysis of eligible data (1952 observations from 23 studies) showed statistically significant differences between the groups (CFNG: 0.94; 95% confidence interval [CI], 0.76-1.00, CLFN: 0.91; 95% CI, 0.49-1.00, MNM: 0.26; 95% CI, 0.05-0.54, DI: 0.98; 95% CI, 0.90-1.00, P < 0.001). In pairwise comparisons, statistically significant differences were found between MNM and other neurotization strategies (P < 0.001 in CFNG compared with MNM, P = 0.013 for CLFN compared with MNM, P < 0.001 for DI compared with MNM). CONCLUSIONS: DI- and CLFN-driven strategies achieved the most promising outcomes, whereas MNM showed the potential to elicit spontaneous smile at a lower extent. Our meta-analysis was limited primarily by incongruency between spontaneity assessment systems. Consensus on a standardized tool would enable more effective comparisons of the outcomes.


Assuntos
Paralisia Facial , Transferência de Nervo , Humanos , Sorriso/fisiologia , Expressão Facial , Paralisia Facial/cirurgia , Nervo Facial/cirurgia , Músculo Masseter/inervação , Transferência de Nervo/métodos
2.
J Plast Reconstr Aesthet Surg ; 86: 48-57, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37696215

RESUMO

BACKGROUND: Identifying relevant perforators is crucial in planning a deep inferior epigastric perforator (DIEP) flap. Color Doppler ultrasonography (CDU) has gained popularity for localizing perforators; however, current evidence on its efficiency is still inconclusive. This study aimed to compare the efficiency of CDU with that of computed tomography angiography (CTA) in localizing and selecting the relevant perforators. METHODS: In this randomized controlled trial, 60 patients undergoing DIEP flap breast reconstruction (uni- or bilateral) were randomly assigned to the CDU group (i.e., CDU was performed to map and select the relevant perforators preoperatively) or the CTA+CDU group (i.e., mapping was based on CTA and supplemented by CDU). CDU was performed by the same surgeon with a well-defined sonography experience from our previous study. The reference XY coordinates of the dissected perforators were measured intraoperatively, and deviations from preoperatively deducted coordinates were calculated (ΔCDU or ΔCTA+CDU). The flaps were categorized according to the number of dissected perforators, and adherence to the preoperative strategy was evaluated. RESULTS: Overall, 22 patients (30 flaps) in the CTA+CDU group and 27 (39 flaps) patients in the CDU group were evaluated. The average ΔCDU (0.6 cm) was significantly lower than the average ΔCTA+CDU (1.0 cm) (p < 0.001). Adherence to the mapping-based dissection strategy was higher in the CDU group; however, the difference was insignificant (p = 0.092). CONCLUSION: CDU is not inferior to CTA + CDU in localizing and selecting relevant DIEA perforators. Therefore, CDU mapping is a possible complementary or substitute modality for CTA mapping.


Assuntos
Mamoplastia , Retalho Perfurante , Humanos , Angiografia por Tomografia Computadorizada/métodos , Retalho Perfurante/cirurgia , Artérias Epigástricas/diagnóstico por imagem , Artérias Epigástricas/cirurgia , Mamoplastia/métodos , Ultrassonografia Doppler em Cores
3.
J Plast Reconstr Aesthet Surg ; 76: 105-112, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36512993

RESUMO

BACKGROUND: Perforator mapping using diagnostic methods facilitates deep inferior epigastric perforator (DIEP) flap planning. Computed tomographic angiography (CTA) is a well-proven tool for perforator mapping. However, the benefits of color Doppler ultrasonography (CDU) are as follows: 1) CDU involves dynamic real-time examination and 2) does not use radiation. Comparing the accuracies of both methods in a cohort of patients, this study aimed to evaluate the learning curve of surgeon-conducted CDU perforator mapping. METHODS: Twenty patients undergoing DIEP flap breast reconstruction were enrolled in a cohort study. All patients underwent CTA perforator mapping preoperatively. XY coordinates of significant perforators were subtracted by a radiologist. A single surgeon (sonographer) with minimal experience with CDU performed CDU perforator mapping, including XY coordinates subtraction. The sonographer was blinded to the CTA data. The reference coordinates of dissected perforators were measured during surgery. Deviations from reference coordinates for both methods were compared, and CDU mapping learning curve was assessed using Joinpoint Regression. RESULTS: We included 20 women (32 DIEP flaps and 59 dissected perforators). The mean deviation between mapped and reference coordinates was 1.00 (0.50-1.12) cm for CDU and 0.71 (0.50-1.12) cm for CTA. The learning curve of CDU mapping showed the breaking point after the seventh patient (≈ 21 localized perforators). After the breaking point, no significant differences between the deviations of both methods were found (p = 0.980). CONCLUSION: A limited number of examinations were needed for the surgeon to learn CDU DIEA perforator mapping with accuracy similar to that of CTA mapping.


Assuntos
Mamoplastia , Retalho Perfurante , Cirurgiões , Humanos , Feminino , Estudos de Coortes , Retalho Perfurante/irrigação sanguínea , Curva de Aprendizado , Artérias Epigástricas/diagnóstico por imagem , Artérias Epigástricas/cirurgia , Mamoplastia/métodos , Ultrassonografia Doppler em Cores/métodos
4.
Acta Chir Plast ; 64(1): 39-43, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35397779

RESUMO

BACKGROUND: Reconstruction of upper and lower extremity defects can be challenging. Especially in distal parts, relatively thin flaps are needed not to interfere with the function or aesthetic appearance of the extremity. The superficial circumflex iliac artery perforator (SCIP) flap represents a powerful but still not so commonly used tool for this kind of reconstruction. In this article, we present several cases of the use of the SCIP flap for extremity defect coverage. CASE SERIES: We present five cases (three men and two women) of upper or lower extremities defect coverage with a SCIP flap performed between January and June 2021 at our department. The mean age of the patients was 43 years (28-67 years). The body mass index was 28.6 on average. Two defects were located on hands and three defects on lower extremities. In three cases, the cause of the defect was trauma, and in the remaining two, it was a tumor resection. The mean thickness of the flap was 9.4 mm. We experienced no total flap loss and no revision surgery for ischemia or congestion was needed. One of the patients developed marginal flap necrosis, which was corrected by necrectomy and direct skin closure. CONCLUSION: Our case series demonstrates the possible use of the SCIP flap in the reconstruction of upper and lower extremities. With its thinness, low donor-site morbidity, and ease of harvest, we recommend the SCIP flap to be considered as one of the primary reconstructive options for various extremities defects.


Assuntos
Retalho Perfurante , Procedimentos de Cirurgia Plástica , Adulto , Feminino , Humanos , Artéria Ilíaca/cirurgia , Extremidade Inferior/cirurgia , Masculino , Retalho Perfurante/irrigação sanguínea , Extremidade Superior/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...