Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Ophthalmol Sci ; 4(4): 100463, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38591050

RESUMO

Purpose: To determine the correlation between blood flow metrics measured by intravenous fluorescein angiography (IVFA) and the blood flow velocity index (BFVi) obtained by laser speckle contrast imaging (LSCI) in infants with retinopathy of prematurity (ROP). Design: Prospective comparative pilot study. Subjects: Seven eyes from 7 subjects with ROP. Methods: Unilateral LSCI and IVFA data were obtained from each subject in the neonatal intensive care unit. Five LSCI-based metrics and 5 IVFA-based metrics were extracted from images to quantify blood flow patterns in the same region of interest. Correlation between LSCI-based and IVFA-based blood flow metrics was compared between 2 subgroups of ROP severity: moderate ROP (defined as stage ≤ 2 without Plus disease) and severe ROP (defined as stage ≥3 or Plus disease). Main Outcome Measures: Pearson and Kendall rank correlation coefficients between IVFA and LSCI metrics; Student t test P values comparing LSCI metrics between "severe" and "moderate" ROP groups. Results: Pearson correlations between IVFA and LSCI included arterial-venous transit time (AVTT) and peak BFVi (pBFVi; r = -0.917; P = 0.004), AVTT and dip BFVi (dBFVi; r = -0.920; P = 0.003), AVTT and mean BFVi (r = -0.927- P = 0.003), and AVTT and volumetric rise index (r = -0.779; P = 0.039). Kendall rank correlation between AVTT and dBFVi was r = -0.619 (P = 0.051). pBFVi was higher in severe ROP than in moderate ROP (8.4 ± 0.6 and 4.4 ± 1.8, respectively; P = 0.0045 using the 2-sample t test with pooled variance and P = 0.0952 using the Wilcoxon rank-sum test). Conclusions: Correlation was found between blood flow metrics obtained by IVFA and noninvasive LSCI techniques. We demonstrate the feasibility of obtaining quantitative metrics using LSCI in infants with ROP in this pilot study; however, further investigation is needed to evaluate its potential use in clinical assessment of ROP severity. Financial Disclosures: Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.

2.
Res Sq ; 2024 Feb 22.
Artigo em Inglês | MEDLINE | ID: mdl-38464120

RESUMO

This prospective study evaluated the relationship between laser speckle contrast imaging (LSCI) ocular blood flow velocity (BFV) and five birth parameters: gestational age (GA), postmenstrual age (PMA), and chronological age (CA) at the time of measurement, birth weight (BW), and current weight (CW) in preterm neonates at risk for retinopathy of prematurity (ROP).38 Neonates with BW < 2 kg, GA < 32 weeks, and PMA between 27-47 weeks underwent 91 LSCI sessions. Correlation tests and regression analysis were performed to quantify relationships between birth parameters and ocular BFV. Mean ocular BFV index in this cohort was 8.8 +/- 4.0 IU. BFV positively correlated with PMA (r = 0.3, p = 0.01), CA (r = 0.3, p = 0.005), and CW (r = 0.3, p = 0.02). BFV did not correlate with GA nor BW (r=-0.2 and r=-0.05, p > 0.05). Regression analysis with mixed models demonstrated that BFV increased by 1.2 for every kilogram of CW, by 0.34 for every week of CA, and by 0.36 for every week of PMA (p = 0.03, 0.004, 0.007, respectively). Our findings indicate that increased age and weight are associated with increased ocular BFV measured using LSCI in premature infants. Future studies investigating the associations between ocular BFV and ROP clinical severity must control for age and/or weight of the infant.

3.
Int Ophthalmol ; 43(9): 3321-3328, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37217809

RESUMO

PURPOSE: We developed model eyes using six polymer materials to determine which materials were most appropriate in simulating real human sclera and extraocular muscle (EOM). METHODS: Five three-dimensional (3-D) printed polymers (FlexFill, PolyFlex, PCTPE, Soft PLA, and NinjaFlex) and one silicone material were systematically tested by board-certified ophthalmologists and senior ophthalmology residents. Material testing included scleral passes with 6-0 Vicryl sutures through each eye model. Participants completed a survey designed to collect demographic data, subjective assessment of each material's accuracy in simulating real human sclera and EOM, and a ranking for each polymer material to identify which would be most suitable for an ophthalmic surgery training tool. The Wilcoxon signed-rank test was conducted to determine if there was a statistically significant difference in the distribution of ranks between the polymer materials. RESULTS: The distribution of ranks for silicone material's "sclera" and "EOM" components were statistically significantly higher than that of all other polymer materials (all p < 0.05). Silicone material received the highest rank for both "sclera" and "EOM" components. Survey results indicated that the silicone material effectively simulated real human tissue. CONCLUSION: Silicone model eyes performed better than 3-D printed polymers as an educational tool for incorporation into a microsurgical training curriculum. Silicone models provide a low-cost teaching tool that allows for independent practice of microsurgical techniques without requiring a wet-laboratory facility.


Assuntos
Internato e Residência , Oftalmologia , Humanos , Polímeros , Competência Clínica , Oftalmologia/educação , Silicones
4.
Hear Res ; 407: 108292, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-34214947

RESUMO

The use of explosive devices in war and terrorism has increased exposure to concussive blasts among both military personnel and civilians, which can cause permanent hearing and balance deficits that adversely affect survivors' quality of life. Significant knowledge gaps on the underlying etiology of blast-induced hearing loss and balance disorders remain, especially with regard to the effect of blast exposure on the vestibular system, the impact of multiple blast exposures, and long-term recovery. To address this, we investigated the effects of blast exposure on the inner ear using a mouse model in conjunction with a high-fidelity blast simulator. Anesthetized animals were subjected to single or triple blast exposures, and physiological measurements and tissue were collected over the course of recovery for up to 180 days. Auditory brainstem responses (ABRs) indicated significantly elevated thresholds across multiple frequencies. Limited recovery was observed at low frequencies in single-blasted mice. Distortion Product Otoacoustic Emissions (DPOAEs) were initially absent in all blast-exposed mice, but low-amplitude DPOAEs could be detected at low frequencies in some single-blast mice by 30 days post-blast, and in some triple-blast mice at 180 days post-blast. All blast-exposed mice showed signs of Tympanic Membrane (TM) rupture immediately following exposure and loss of outer hair cells (OHCs) in the basal cochlear turn. In contrast, the number of Inner Hair Cells (IHCs) and spiral ganglion neurons was unchanged following blast-exposure. A significant reduction in IHC pre-synaptic puncta was observed in the upper turns of blast-exposed cochleae. Finally, we found no significant loss of utricular hair cells or changes in vestibular function as assessed by vestibular evoked potentials. Our results suggest that (1) blast exposure can cause severe, long-term hearing loss which may be partially due to slow TM healing or altered mechanical properties of healed TMs, (2) traumatic levels of sound can still reach the inner ear and cause basal OHC loss despite middle ear dysfunction caused by TM rupture, (3) blast exposure may result in synaptopathy in humans, and (4) balance deficits after blast exposure may be primarily due to traumatic brain injury, rather than damage to the peripheral vestibular system.


Assuntos
Perda Auditiva , Emissões Otoacústicas Espontâneas , Animais , Limiar Auditivo , Potenciais Evocados Auditivos do Tronco Encefálico , Células Ciliadas Auditivas Externas , Qualidade de Vida , Sistema Vestibular
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...