1.
Am J Ophthalmol ; 173: 76-83, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27702623

RESUMO

PURPOSE: Age-related changes in lens elasticity and ciliary muscle contractility can affect how ocular parameters respond to cycloplegia, and therefore intraocular lens (IOL) power measurements calculated by formulas using anterior chamber depth (ACD), lens thickness (LT), or white-to-white (WtW) for effective lens position prediction can vary. In response, using swept-source optical biometry in prepresbyopic and presbyopic eyes, we investigated changes in ocular parameters and IOL power calculations attributable to cycloplegia. DESIGN: Cross-sectional study. METHODS: In 38 prepresbyopic and 42 presbyopic eyes, we measured pupil diameter, radius of corneal curvature values, central corneal thickness, WtW, ACD, LT, and axial length both before and after cycloplegia. We determined IOL power calculations with the Sanders-Retzlaff-Kraff/theoretical, Holladay 2, and Haigis formulas. To pinpoint the effect of cycloplegia, we recorded refractive predictions in pre- and postdilation conditions according to the same IOL power calculations, even if postdilation IOL power calculations had changed. RESULTS: With cycloplegia, pupil diameter changed significantly more in presbyopic eyes (P < .001). Central corneal thickness decreased in prepresbyopic eyes (P = .048), whereas WtW increased in presbyopic eyes (P = .02). In both groups, ACD and LT changed significantly (P < .001). IOL power calculations according to the Holladay 2 formula differed in prepresbyopic eyes (P = .042), and refractive predictions with the Holladay 2 and Haigis formulas differed significantly in prepresbyopic eyes (P = .043 and P = .022, respectively). CONCLUSION: Surgeons should consider the effect of cycloplegia on refractive prediction errors and IOL power calculations determined with Haigis and Holladay 2 formulas, especially in prepresbyopic ages.


Assuntos
Envelhecimento , Comprimento Axial do Olho/anatomia & histologia , Biometria/métodos , Lentes Intraoculares , Midriáticos/farmacologia , Presbiopia/diagnóstico , Refração Ocular/fisiologia , Adulto , Comprimento Axial do Olho/efeitos dos fármacos , Estudos Transversais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Óptica e Fotônica , Presbiopia/fisiopatologia , Curva ROC , Adulto Jovem
2.
Clin Ophthalmol ; 10: 1351-6, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27555742

RESUMO

AIM: To evaluate the clinical applicability of the water-drinking test in treatment-naive primary open-angle glaucoma patients. METHODS: Twenty newly diagnosed primary open-angle glaucoma patients and 20 healthy controls were enrolled in this prospective study. The water-drinking test was performed at baseline and 6 weeks and 3 months after prostaglandin analog treatment. Peak and fluctuation of intraocular pressure (IOP) measurements obtained with the water-drinking test during follow-up were analyzed. Analysis of variance for repeated measures and paired and unpaired t-tests were used for statistical analysis. RESULTS: The mean baseline IOP values in patients with primary open-angle glaucoma were 25.1±4.6 mmHg before prostaglandin analog treatment, 19.8±3.7 mmHg at week 6, and 17.9±2.2 mmHg at month 3 after treatment. The difference in mean baseline IOP of the water-drinking tests was statistically significant (P<0.001). At 6 weeks of prostaglandin analog treatment, two patients had high peak and fluctuation of IOP measurements despite a reduction in baseline IOP. After modifying treatment, patients had lower peak and fluctuation of IOP values at month 3 of the study. CONCLUSION: Peak and fluctuation of IOP in response to the water-drinking test were lower with prostaglandin analogs compared with before medication. The water-drinking test can represent an additional benefit in the management of glaucoma patients, especially by detecting higher peak and fluctuation of IOP values despite a reduced mean IOP. Therefore, it could be helpful as a supplementary method in monitoring IOP in the clinical practice.

3.
J Pharmacopuncture ; 19(1): 28-36, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-27280047

RESUMO

OBJECTIVES: The purpose of this study is to achieve a vision for autistic children and their parents aimed at generating interest in ideas such as "Sanitas Per Aquam" (SPA), massage and music therapy, which has begun to have widespread use and to attract attention. METHODS: This cross-sectional, descriptive study was carried out with autistic children and their parents from February to April 2015 in Mugla, Turkey. The study was began by interviewing experts in the field and by developing a suitable assessment questionnaire. In order to direct the flow of conversation between the researchers and the autisitc children and their parents, the researchers conducted semi-structured face to face interviews in a form that had been determined by using reports in the literature and the opinions of experts in the field. RESULTS: Forty two boys (84%) and eight girls (16%) with autism participated in our study. Children in the 0 ─ 7 age group spent long time in the bathroom (P = 0.001). Boys liked to be hugged more than girls (P = 0.01). Children ages 0 ─ 7 years liked bright lighting while those 15 years of age and older liked gloomy lighting (P = 0.009). Except for these statistically significant sex- and age-related differences, no other statistically significant differences were noted in the parameters of this study. Although the result was not statistically significant, more children with mild autism disorder obeyed commands like inhale or exhale (P = 0.051). CONCLUSION: Treatment for autism spectrum disorders is not yet fully possible, so many studies are being done to alleviate some symptoms and to improve the quality of life for individuals with autism and their families. As a result of our study, whether touching the areas the children want touched and listening to their favorite music are required to stimulate the brain remain as questions in our minds.

4.
Clin Genitourin Cancer ; 14(4): e387-91, 2016 08.
Artigo em Inglês | MEDLINE | ID: mdl-27036974

RESUMO

INTRODUCTION: The aim of this study was to determine the minimal core length to be taken per cc of prostate volume for an effective prostate biopsy. PATIENTS AND METHODS: A retrospective analysis was performed on the records of 379 patients who underwent a first prostate biopsy with 12 to 16 cores under transrectal ultrasound guidance between September 2012 and April 2015. For each patient, the core length per cc of the prostate and the percentage of sampled prostate volume were calculated, and these values were compared between the patients with and without prostate cancer. RESULTS: A total of 348 patients were included in the study. Cancer was determined in 26.4% of patients. The mean core length taken per cc of prostate and the percentage of sampled prostate volume were determined to be 3.40 ± 0.15 mm/cc (0.26%; range, 0.08-0.63 cc) in patients with cancer and 2.75 ± 0.08 mm/cc (0.20%; range, 0.04-0.66 cc) in patients without cancer (P = .000 and P = .000), respectively. Core length taken per cc of prostate of > 3.31 mm/cc was found to be related to an increase in the rates of prostate cancer diagnosis (odds ratio, 2.84; 95% confidence interval, 1.68-4.78). The rate of cancer determination for core length taken per cc of prostate of < 3.31 mm/cc was 19.9% and of > 3.31 mm/cc, 41.1%. CONCLUSIONS: Core length taken per cc of prostate and the percentage of sampled prostate volume are important morphometric parameters in the determination of prostate cancer. The results of study suggest a core length per cc of the prostate of > 3.31 mm/cc as a cutoff value for quality assurance.


Assuntos
Próstata/patologia , Neoplasias da Próstata/diagnóstico , Idoso , Biópsia com Agulha de Grande Calibre , Humanos , Masculino , Pessoa de Meia-Idade , Razão de Chances , Estudos Retrospectivos , Sensibilidade e Especificidade , Carga Tumoral , Ultrassonografia
5.
Acta Ophthalmol ; 94(7): e528-e533, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27040022

RESUMO

PURPOSE: To analyse the effect of cataract surgery on diurnal intra-ocular pressure (IOP) fluctuation in primary angle-closure glaucoma (PACG) eyes. METHODS: Thirty-nine eyes of 24 patients with PACG scheduled for cataract surgery were enrolled to this prospective study. A record was made which included mean IOP measurement, anterior chamber depth (ACD), anterior chamber angle (ACA), number of antiglaucomatous medications, visual field analysis (mean deviation - MD and pattern standard deviation - PSD) and responses to the Glaucoma Quality of Life-15 (GQL-15) questionnaires. The eyes were re-evaluated at 2 and 3 months of cataract surgery. RESULTS: IOP fluctuation was decreased from 4.58 ± 2.07 mmHg to 2.84 ± 1.5 mmHg (p < 0.001). The decrease in mean IOP, the number of glaucoma eye drops required (p < 0.001, p = 0.012, respectively) and the increase in mean ACD, ACA grading and SITA-standard MD (p < 0.001, p < 0.001, and p = 0.01, respectively) were statistically significant. The mean GQL-15 score was also improved (p < 0.001). The change in IOP fluctuation correlated positively with the preoperative IOP fluctuation (r = 0.56 p = 0.00), the change in ACD (r = 0.703, p < 0.001) and the change in ACA (r = 0.664, p < 0.001). In multivariate analysis, preoperative IOP fluctuation and postoperative increase in ACD were significantly associated with a reduction in IOP fluctuation of an average of 1.1 mmHg per unit change (p = 0.00 and p = 0.019, respectively). CONCLUSIONS: Cataract surgery in PACG provides the opportunity to address many pathologies with one intervention; improving vision, diminishing IOP, blunting IOP fluctuation, reducing need for medications, eliminating a narrow angle and improving GQL-15 scores.


Assuntos
Anti-Hipertensivos/administração & dosagem , Glaucoma de Ângulo Fechado/fisiopatologia , Glaucoma de Ângulo Fechado/terapia , Pressão Intraocular/fisiologia , Iridectomia , Terapia a Laser , Facoemulsificação , Idoso , Idoso de 80 Anos ou mais , Segmento Anterior do Olho/patologia , Ritmo Circadiano/fisiologia , Feminino , Glaucoma de Ângulo Fechado/diagnóstico , Humanos , Iris/cirurgia , Implante de Lente Intraocular , Masculino , Soluções Oftálmicas , Estudos Prospectivos , Pseudofacia/fisiopatologia , Qualidade de Vida/psicologia , Tonometria Ocular , Campos Visuais