Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Gastrointest Endosc ; 71(4): 835-41, 2010 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-19942215

RESUMO

BACKGROUND: Current devices for hemostasis in flexible endoscopy are inferior to methods used during open or laparoscopic surgery and might be ineffective for natural orifice transluminal endoscopic surgery. OBJECTIVE: To compare new flexible bipolar forceps (FBF), designed principally for natural orifice transluminal endoscopic surgery, with laparoscopic bipolar forceps (LBF) for hemostasis of intra-abdominal porcine arteries. SETTING: Surgical laboratories in Europe and the United States. DESIGN AND INTERVENTIONS: New FBF for hemostasis (3.7-mm diameter), featuring electrode isolation, were compared with rigid 5-mm LBF (ERBE BiClamp LAP forceps) at recommended settings. A porcine model of acute hemostasis was prepared by suturing the uterine horns and cecum to the abdominal wall, exposing uterine arteries, ovarian pedicles, cecal mesenteric bundles, and the inferior mesenteric artery. This allowed access to 10 vessels in each pig by transabdominal laparoscopic devices or a transgastric double-channel gastroscope. Vessels were measured, coagulated at 4 and more points, and transected. Blood pressure was increased to more than 200 mm Hg for 10 minutes by administering phenylephrine. Delayed bleeding was identified. MAIN OUTCOME MEASUREMENTS: In 7 pigs, a total of 65 vessels (1.5-6.0 mm) were randomly allocated to FBF (n = 32) or LBF (n = 33). Successful hemostasis both before and after blood pressure increase was equivalent between the 2 groups (before: 88% FBF vs 88% LBF, not significant [NS]; after: 97% FBF vs 94% LBF, NS). With FBF, the number of seals per vessel was 4.8 vs 4.4 with LBF (NS). The energy used to create FBF seals was 19.8 J vs 38.2 J for LBF (P < .05). LIMITATIONS: Results from porcine studies may not reflect patient outcomes. CONCLUSIONS: In a porcine model, transgastric FBF endoscopic hemostasis was as effective as conventional laparoscopic hemostasis using LBF across a wide range of vessels.


Assuntos
Eletrocoagulação/instrumentação , Gastroscópios , Hemostasia Cirúrgica/instrumentação , Laparoscópios , Procedimentos Cirúrgicos Minimamente Invasivos/instrumentação , Instrumentos Cirúrgicos , Animais , Ceco/irrigação sanguínea , Desenho de Equipamento , Feminino , Artérias Mesentéricas/cirurgia , Artéria Mesentérica Inferior/cirurgia , Ovário/irrigação sanguínea , Suínos , Estudos de Tempo e Movimento , Artéria Uterina/cirurgia , Veias/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA