Resultados 1 - 20 de 27
Filtrar
1.
Cancers (Basel) ; 14(23)2022 Nov 29.
Artigo em Inglês | MEDLINE | ID: mdl-36497372

RESUMO

Introduction: Delays in the diagnosis and treatment of endometrial cancer negatively impact patient survival. The aim of this study was to establish whether rapid evaporative ionisation mass spectrometry using the iKnife can accurately distinguish between normal and malignant endometrial biopsy tissue samples in real time, enabling point-of-care (POC) diagnoses. Methods: Pipelle biopsy samples were obtained from consecutive women needing biopsies for clinical reasons. A Waters G2-XS Xevo Q-Tof mass spectrometer was used in conjunction with a modified handheld diathermy (collectively called the 'iKnife'). Each tissue sample was processed with diathermy, and the resultant surgical aerosol containing ionic lipid species was then analysed, producing spectra. Principal component analyses and linear discriminant analyses were performed to determine variance in spectral signatures. Leave-one-patient-out cross-validation was used to test the diagnostic accuracy. Results: One hundred and fifty patients provided Pipelle biopsy samples (85 normal, 59 malignant, 4 hyperplasia and 2 insufficient), yielding 453 spectra. The iKnife differentiated between normal and malignant endometrial tissues on the basis of differential phospholipid spectra. Cross-validation revealed a diagnostic accuracy of 89% with sensitivity, specificity, positive predictive value and negative predictive value of 85%, 93%, 94% and 85%, respectively. Conclusions: This study is the first to use the iKnife to identify cancer in endometrial Pipelle biopsy samples. These results are highly encouraging and suggest that the iKnife could be used in the clinic to provide a POC diagnosis.

2.
Metabolites ; 12(11)2022 Nov 17.
Artigo em Inglês | MEDLINE | ID: mdl-36422272

RESUMO

Rapid evaporative ionization mass spectrometry (REIMS) is a direct tissue metabolic profiling technique used to accurately classify tissues using pre-built mass spectral databases. The reproducibility of the analytical equipment, methodology and tissue classification algorithms has yet to be evaluated over multiple sites, which is an essential step for developing this technique for future clinical applications. In this study, we harmonized REIMS methodology using single-source reference material across four sites with identical equipment: Imperial College London (UK); Waters Research Centre (Hungary); Maastricht University (The Netherlands); and Queen's University (Canada). We observed that method harmonization resulted in reduced spectral variability across sites. Each site then analyzed four different types of locally-sourced food-grade animal tissue. Tissue recognition models were created at each site using multivariate statistical analysis based on the different metabolic profiles observed in the m/z range of 600-1000, and these models were tested against data obtained at the other sites. Cross-validation by site resulted in 100% correct classification of two reference tissues and 69-100% correct classification for food-grade meat samples. While we were able to successfully minimize between-site variability in REIMS signals, differences in animal tissue from local sources led to significant variability in the accuracy of an individual site's model. Our results inform future multi-site REIMS studies applied to clinical samples and emphasize the importance of carefully-annotated samples that encompass sufficient population diversity.

3.
J Am Soc Mass Spectrom ; 32(6): 1393-1401, 2021 Jun 02.
Artigo em Inglês | MEDLINE | ID: mdl-33980015

RESUMO

Mass spectrometry has established itself as a powerful tool in the chemical, biological, medical, environmental, and agricultural fields. However, experimental approaches and potential application areas have been limited by a traditional reliance on sample preparation, extraction, and chromatographic separation. Ambient ionization mass spectrometry methods have addressed this challenge but are still somewhat restricted in requirements for sample manipulation to make it suitable for analysis. These limitations are particularly restrictive in view of the move toward high-throughput and automated analytical workflows. To address this, we present what we consider to be the first automated sample-preparation-free mass spectrometry platform utilizing a carbon dioxide (CO2) laser for sample thermal desorption linked to the rapid evaporative ionization mass spectrometry (LA-REIMS) methodology. We show that the pulsatile operation of the CO2 laser is the primary factor in achieving high signal-to-noise ratios. We further show that the LA-REIMS automated platform is suited to the analysis of three diverse biological materials within different application areas. First, clinical microbiology isolates were classified to species level with an accuracy of 97.2%, the highest accuracy reported in current literature. Second, fecal samples from a type 2 diabetes mellitus cohort were analyzed with LA-REIMS, which allowed tentative identification of biomarkers which are potentially associated with disease pathogenesis and a disease classification accuracy of 94%. Finally, we showed the ability of the LA-REIMS system to detect instances of adulteration of cooking oil and determine the geographical area of production of three protected olive oil products with 100% classification accuracy.


Assuntos
Contaminação de Alimentos/análise , Espectrometria de Massas/métodos , Técnicas Microbiológicas/métodos , Manejo de Espécimes/instrumentação , Manejo de Espécimes/métodos , Biomarcadores/análise , Estudos de Casos e Controles , Diabetes Mellitus Tipo 2/metabolismo , Desenho de Equipamento , Fezes , Tecnologia de Fibra Óptica , Análise de Alimentos/métodos , Humanos , Lasers , Metabolômica/métodos , Azeite de Oliva/análise
4.
Proc Natl Acad Sci U S A ; 117(13): 7338-7346, 2020 03 31.
Artigo em Inglês | MEDLINE | ID: mdl-32179675

RESUMO

Clearance of surgical margins in cervical cancer prevents the need for adjuvant chemoradiation and allows fertility preservation. In this study, we determined the capacity of the rapid evaporative ionization mass spectrometry (REIMS), also known as intelligent knife (iKnife), to discriminate between healthy, preinvasive, and invasive cervical tissue. Cervical tissue samples were collected from women with healthy, human papilloma virus (HPV) ± cervical intraepithelial neoplasia (CIN), or cervical cancer. A handheld diathermy device generated surgical aerosol, which was transferred into a mass spectrometer for subsequent chemical analysis. Combination of principal component and linear discriminant analysis and least absolute shrinkage and selection operator was employed to study the spectral differences between groups. Significance of discriminatory m/z features was tested using univariate statistics and tandem MS performed to elucidate the structure of the significant peaks allowing separation of the two classes. We analyzed 87 samples (normal = 16, HPV ± CIN = 50, cancer = 21 patients). The iKnife discriminated with 100% accuracy normal (100%) vs. HPV ± CIN (100%) vs. cancer (100%) when compared to histology as the gold standard. When comparing normal vs. cancer samples, the accuracy was 100% with a sensitivity of 100% (95% CI 83.9 to 100) and specificity 100% (79.4 to 100). Univariate analysis revealed significant MS peaks in the cancer-to-normal separation belonging to various classes of complex lipids. The iKnife discriminates healthy from premalignant and invasive cervical lesions with high accuracy and can improve oncological outcomes and fertility preservation of women treated surgically for cervical cancer. Larger in vivo research cohorts are required to validate these findings.


Assuntos
Espectrometria de Massas/instrumentação , Espectrometria de Massas/métodos , Neoplasias do Colo do Útero/patologia , Adulto , Idoso , Análise Discriminante , Feminino , Cromatografia Gasosa-Espectrometria de Massas/instrumentação , Cromatografia Gasosa-Espectrometria de Massas/métodos , Humanos , Margens de Excisão , Pessoa de Meia-Idade , Papillomaviridae , Infecções por Papillomavirus/patologia , Lesões Pré-Cancerosas/diagnóstico , Lesões Pré-Cancerosas/cirurgia , Sensibilidade e Especificidade , Neoplasias do Colo do Útero/diagnóstico , Neoplasias do Colo do Útero/cirurgia , Displasia do Colo do Útero
5.
Nat Protoc ; 14(11): 3162-3182, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31597965

RESUMO

Rapid, sensitive, precise and accurate analysis of samples in their native in vivo environment is critical to better decipher physiological and physiopathological mechanisms. SpiderMass is an ambient mass spectrometry (MS) system designed for mobile in vivo and real-time surface analyses of biological tissues. The system uses a fibered laser, which is tuned to excite the most intense vibrational band of water, resulting in a process termed water-assisted laser desorption/ionization (WALDI). The water molecules act as an endogenous matrix in a matrix-assisted laser desorption ionization (MALDI)-like scenario, leading to the desorption/ionization of biomolecules (lipids, metabolites and proteins). The ejected material is transferred to the mass spectrometer through an atmospheric interface and a transfer line that is several meters long. Here, we formulate a three-stage procedure that includes (i) a laser system setup coupled to a Waters Q-TOF or Thermo Fisher Q Exactive mass analyzer, (ii) analysis of specimens and (iii) data processing. We also describe the optimal setup for the analysis of cell cultures, fresh-frozen tissue sections and in vivo experiments on skin. With proper optimization, the system can be used for a variety of different targets and applications. The entire procedure takes 1-2 d for complex samples.


Assuntos
Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos , Animais , Linhagem Celular , Cães , Desenho de Equipamento , Secções Congeladas , Humanos , Neoplasias/química , Ratos , Pele/química , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/instrumentação , Água/química
6.
Anal Chem ; 91(15): 9784-9791, 2019 08 06.
Artigo em Inglês | MEDLINE | ID: mdl-31194519

RESUMO

Rapid evaporative ionization mass spectrometry (REIMS) is a highly versatile technique allowing the sampling of a range of biological solid or liquid samples with no sample preparation. The cost of such a direct approach is that certain sample types provide only moderate amounts of chemical information. Here, we introduce a matrix assisted version of the technique (MA-REIMS), where an aerosol of a pure solvent, such as isopropanol, is mixed with the sample aerosol generated by rapid evaporation of the sample, and it is shown to enhance the signal intensity obtained from a REIMS sampling event by over 2 orders of magnitude. Such an increase greatly expands the scope of the technique, while providing additional benefits such as reducing the fouling of the REIMS source and allowing for a simple method of constant introduction of a calibration correction compound for accurate mass measurements. A range of experiments are presented in order to investigate the processes that occur within this modified approach, and applications where such enhancements are critical, such as intrasurgical tissue identification, are discussed.


Assuntos
Espectrometria de Massas/métodos , Solventes/química , Fatores de Tempo , Volatilização
7.
Sci Rep ; 9(1): 6295, 2019 04 18.
Artigo em Inglês | MEDLINE | ID: mdl-31000779

RESUMO

The morphological transformation of beef tissues after various processing treatments facilitates the addition of cheap offal products. Undetectable to the naked eye, analytical techniques are required to identify such scenarios within minced and processed products. DNA methodologies are ill-equipped to detect adulteration of offal cuts from the same species and vibrational spectroscopic studies, although rapid and non-destructive, have proved inconclusive as to whether the specific adulterant can be identified. For the first time we present a mass spectrometric approach employing an ambient ionisation process to eliminate sample preparation and provide near-instantaneous results. Rapid evaporative ionisation mass spectrometry (REIMS) was used to assess its capabilities of detecting minced beef adulteration with beef brain, heart, kidney, large intestine and liver tissues and chemometric analysis enabled unique or significant markers to be identified. The adulteration levels detected with the REIMS technology when analysing raw adulterated beef burgers were; brain (5%); heart (1-10%); kidney (1-5%); large intestine (1-10%) and liver (5-10%). For boiled adulterated samples; brain (5-10%); heart (1-10%); kidney (1-5%); large intestine (1-10%) and liver (5-10%). REIMS allows rapid and specific identification of offal cuts within adulterated beef burgers and could provide a paradigm shift across many authenticity applications.


Assuntos
DNA/genética , Análise de Alimentos/métodos , Contaminação de Alimentos/análise , Carne Vermelha/análise , Animais , Bovinos , DNA/isolamento & purificação , Humanos , Espectrometria de Massas , Carne/análise , Produtos da Carne/análise , Análise de Componente Principal
8.
Cancer Cell ; 34(5): 840-851.e4, 2018 11 12.
Artigo em Inglês | MEDLINE | ID: mdl-30344004

RESUMO

Histopathological diagnosis of biopsy samples and margin assessment of surgical specimens are challenging aspects in sarcoma. Using dog patient tissues, we assessed the performance of a recently developed technology for fast ex vivo molecular lipid-based diagnosis of sarcomas. The instrument is based on mass spectrometry (MS) molecular analysis through a laser microprobe operating under ambient conditions using excitation of endogenous water molecules. Classification models based on cancer/normal/necrotic, tumor grade, and subtypes showed a minimum of 97.63% correct classification. Specific markers of normal, cancer, and necrotic regions were identified by tandem MS and validated by MS imaging. Real-time detection capabilities were demonstrated by ex vivo analysis with direct interrogation of classification models.


Assuntos
Detecção Precoce de Câncer/métodos , Lipídeos/análise , Técnicas de Diagnóstico Molecular/métodos , Sarcoma/diagnóstico , Sarcoma/patologia , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos , Animais , Cães , Gradação de Tumores/métodos
9.
Br J Cancer ; 118(10): 1349-1358, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29670294

RESUMO

BACKGROUND: Survival from ovarian cancer (OC) is improved with surgery, but surgery can be complex and tumour identification, especially for borderline ovarian tumours (BOT), is challenging. The Rapid Evaporative Ionisation Mass Spectrometric (REIMS) technique reports tissue histology in real-time by analysing aerosolised tissue during electrosurgical dissection. METHODS: Aerosol produced during diathermy of tissues was sampled with the REIMS interface. Histological diagnosis and mass spectra featuring complex lipid species populated a reference database on which principal component, linear discriminant and leave-one-patient-out cross-validation analyses were performed. RESULTS: A total of 198 patients provided 335 tissue samples, yielding 3384 spectra. Cross-validated OC classification vs separate normal tissues was high (97·4% sensitivity, 100% specificity). BOT were readily distinguishable from OC (sensitivity 90.5%, specificity 89.7%). Validation with fresh tissue lead to excellent OC detection (100% accuracy). Histological agreement between iKnife and histopathologist was very good (kappa 0.84, P < 0.001, z = 3.3). Five predominantly phosphatidic acid (PA(36:2)) and phosphatidyl-ethanolamine (PE(34:2)) lipid species were identified as being significantly more abundant in OC compared to normal tissue or BOT (P < 0.001, q < 0.001). CONCLUSIONS: The REIMS iKnife distinguishes gynaecological tissues by analysing mass-spectrometry-derived lipidomes from tissue diathermy aerosols. Rapid intra-operative gynaecological tissue diagnosis may improve surgical care when histology is unknown, leading to personalised operations tailored to the individual.


Assuntos
Eletrocirurgia/métodos , Metabolismo dos Lipídeos/genética , Lipídeos/isolamento & purificação , Neoplasias Ovarianas/cirurgia , Feminino , Humanos , Lipídeos/genética , Margens de Excisão , Metabolômica , Monitorização Intraoperatória/métodos , Neoplasias Ovarianas/metabolismo , Neoplasias Ovarianas/fisiopatologia , Análise de Componente Principal , Espectrometria de Massas por Ionização por Electrospray
10.
J Am Soc Mass Spectrom ; 29(1): 26-33, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-29038998

RESUMO

The recently developed automated, high-throughput monopolar REIMS platform is suited for the identification of clinically important microorganisms. Although already comparable to the previously reported bipolar forceps method, optimization of the geometry of monopolar electrodes, at the heart of the system, holds the most scope for further improvements to be made. For this, sharp tip and round shaped electrodes were optimized to maximize species-level classification accuracy. Following optimization of the distance between the sample contact point and tube inlet with the sharp tip electrodes, the overall cross-validation accuracy improved from 77% to 93% in negative and from 33% to 63% in positive ion detection modes, compared with the original 4 mm distance electrode. As an alternative geometry, round tube shaped electrodes were developed. Geometry optimization of these included hole size, number, and position, which were also required to prevent plate pick-up due to vacuum formation. Additional features, namely a metal "X"-shaped insert and a pin in the middle were included to increase the contact surface with a microbial biomass to maximize aerosol production. Following optimization, cross-validation scores showed improvement in classification accuracy from 77% to 93% in negative and from 33% to 91% in positive ion detection modes. Supervised models were also built, and after the leave 20% out cross-validation, the overall classification accuracy was 98.5% in negative and 99% in positive ion detection modes. This suggests that the new generation of monopolar REIMS electrodes could provide substantially improved species level identification accuracies in both polarity detection modes. Graphical abstract.


Assuntos
Bactérias/classificação , Técnicas Bacteriológicas/métodos , Eletrodos , Espectrometria de Massas/instrumentação , Espectrometria de Massas/métodos , Bactérias/isolamento & purificação , Técnicas Bacteriológicas/instrumentação , Desenho de Equipamento , Análise de Componente Principal , Razão Sinal-Ruído , Fluxo de Trabalho
11.
Metabolomics ; 13(12): 153, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29151824

RESUMO

INTRODUCTION: Fish fraud detection is mainly carried out using a genomic profiling approach requiring long and complex sample preparations and assay running times. Rapid evaporative ionisation mass spectrometry (REIMS) can circumvent these issues without sacrificing a loss in the quality of results. OBJECTIVES: To demonstrate that REIMS can be used as a fast profiling technique capable of achieving accurate species identification without the need for any sample preparation. Additionally, we wanted to demonstrate that other aspects of fish fraud other than speciation are detectable using REIMS. METHODS: 478 samples of five different white fish species were subjected to REIMS analysis using an electrosurgical knife. Each sample was cut 8-12 times with each one lasting 3-5 s and chemometric models were generated based on the mass range m/z 600-950 of each sample. RESULTS: The identification of 99 validation samples provided a 98.99% correct classification in which species identification was obtained near-instantaneously (≈ 2 s) unlike any other form of food fraud analysis. Significant time comparisons between REIMS and polymerase chain reaction (PCR) were observed when analysing 6 mislabelled samples demonstrating how REIMS can be used as a complimentary technique to detect fish fraud. Additionally, we have demonstrated that the catch method of fish products is capable of detection using REIMS, a concept never previously reported. CONCLUSIONS: REIMS has been proven to be an innovative technique to help aid the detection of fish fraud and has the potential to be utilised by fisheries to conduct their own quality control (QC) checks for fast accurate results.

12.
Breast Cancer Res ; 19(1): 59, 2017 05 23.
Artigo em Inglês | MEDLINE | ID: mdl-28535818

RESUMO

BACKGROUND: Re-operation for positive resection margins following breast-conserving surgery occurs frequently (average = 20-25%), is cost-inefficient, and leads to physical and psychological morbidity. Current margin assessment techniques are slow and labour intensive. Rapid evaporative ionisation mass spectrometry (REIMS) rapidly identifies dissected tissues by determination of tissue structural lipid profiles through on-line chemical analysis of electrosurgical aerosol toward real-time margin assessment. METHODS: Electrosurgical aerosol produced from ex-vivo and in-vivo breast samples was aspirated into a mass spectrometer (MS) using a monopolar hand-piece. Tissue identification results obtained by multivariate statistical analysis of MS data were validated by histopathology. Ex-vivo classification models were constructed from a mass spectral database of normal and tumour breast samples. Univariate and tandem MS analysis of significant peaks was conducted to identify biochemical differences between normal and cancerous tissues. An ex-vivo classification model was used in combination with bespoke recognition software, as an intelligent knife (iKnife), to predict the diagnosis for an ex-vivo validation set. Intraoperative REIMS data were acquired during breast surgery and time-synchronized to operative videos. RESULTS: A classification model using histologically validated spectral data acquired from 932 sampling points in normal tissue and 226 in tumour tissue provided 93.4% sensitivity and 94.9% specificity. Tandem MS identified 63 phospholipids and 6 triglyceride species responsible for 24 spectral differences between tissue types. iKnife recognition accuracy with 260 newly acquired fresh and frozen breast tissue specimens (normal n = 161, tumour n = 99) provided sensitivity of 90.9% and specificity of 98.8%. The ex-vivo and intra-operative method produced visually comparable high intensity spectra. iKnife interpretation of intra-operative electrosurgical vapours, including data acquisition and analysis was possible within a mean of 1.80 seconds (SD ±0.40). CONCLUSIONS: The REIMS method has been optimised for real-time iKnife analysis of heterogeneous breast tissues based on subtle changes in lipid metabolism, and the results suggest spectral analysis is both accurate and rapid. Proof-of-concept data demonstrate the iKnife method is capable of online intraoperative data collection and analysis. Further validation studies are required to determine the accuracy of intra-operative REIMS for oncological margin assessment.


Assuntos
Neoplasias da Mama/cirurgia , Mama/cirurgia , Eletrocirurgia/instrumentação , Mastectomia Segmentar/instrumentação , Mama/patologia , Neoplasias da Mama/patologia , Eletrocirurgia/métodos , Feminino , Humanos , Espectrometria de Massas por Ionização por Electrospray
13.
Surg Endosc ; 31(3): 1361-1370, 2017 03.
Artigo em Inglês | MEDLINE | ID: mdl-27501728

RESUMO

BACKGROUND: This pilot study assessed the diagnostic accuracy of rapid evaporative ionization mass spectrometry (REIMS) in colorectal cancer (CRC) and colonic adenomas. METHODS: Patients undergoing elective surgical resection for CRC were recruited at St. Mary's Hospital London and The Royal Marsden Hospital, UK. Ex vivo analysis was performed using a standard electrosurgery handpiece with aspiration of the electrosurgical aerosol to a Xevo G2-S iKnife QTof mass spectrometer (Waters Corporation). Histological examination was performed for validation purposes. Multivariate analysis was performed using principal component analysis and linear discriminant analysis in Matlab 2015a (Mathworks, Natick, MA). A modified REIMS endoscopic snare was developed (Medwork) and used prospectively in five patients to assess its feasibility during hot snare polypectomy. RESULTS: Twenty-eight patients were recruited (12 males, median age 71, range 35-89). REIMS was able to reliably distinguish between cancer and normal adjacent mucosa (NAM) (AUC 0.96) and between NAM and adenoma (AUC 0.99). It had an overall accuracy of 94.4 % for the detection of cancer versus adenoma and an adenoma sensitivity of 78.6 % and specificity of 97.3 % (AUC 0.99) versus cancer. Long-chain phosphatidylserines (e.g., PS 22:0) and bacterial phosphatidylglycerols were over-expressed on cancer samples, while NAM was defined by raised plasmalogens and triacylglycerols expression and adenomas demonstrated an over-expression of ceramides. REIMS was able to classify samples according to tumor differentiation, tumor budding, lymphovascular invasion, extramural vascular invasion and lymph node micrometastases (AUC's 0.88, 0.87, 0.83, 0.81 and 0.81, respectively). During endoscopic deployment, colonoscopic REIMS was able to detect target lipid species such as ceramides during hot snare polypectomy. CONCLUSION: REIMS demonstrates high diagnostic accuracy for tumor type and for established histological features of poor prognostic outcome in CRC based on a multivariate analysis of the mucosal lipidome. REIMS could augment endoscopic and imaging technologies for precision phenotyping of colorectal cancer.


Assuntos
Adenoma/patologia , Colonoscopia , Neoplasias Colorretais/patologia , Mucosa Intestinal/metabolismo , Espectrometria de Massas/métodos , Adenoma/metabolismo , Adulto , Idoso , Idoso de 80 Anos ou mais , Ceramidas/metabolismo , Neoplasias Colorretais/metabolismo , Feminino , Humanos , Mucosa Intestinal/patologia , Cuidados Intraoperatórios , Masculino , Pessoa de Meia-Idade , Fosfatidilgliceróis/metabolismo , Fosfatidilserinas/metabolismo , Projetos Piloto , Plasmalogênios/metabolismo , Estudos Prospectivos , Sensibilidade e Especificidade , Triglicerídeos/metabolismo
14.
Sci Rep ; 6: 36788, 2016 11 14.
Artigo em Inglês | MEDLINE | ID: mdl-27841356

RESUMO

Members of the genus Candida, such as C. albicans and C. parapsilosis, are important human pathogens. Other members of this genus, previously believed to carry minimal disease risk, are increasingly recognised as important human pathogens, particularly because of variations in susceptibilities to widely used anti-fungal agents. Thus, rapid and accurate identification of clinical Candida isolates is fundamental in ensuring timely and effective treatments are delivered. Rapid Evaporative Ionisation Mass Spectrometry (REIMS) has previously been shown to provide a high-throughput platform for the rapid and accurate identification of bacterial and fungal isolates. In comparison to commercially available matrix assisted laser desorption ionisation time of flight mass spectrometry (MALDI-ToF), REIMS based methods require no preparative steps nor time-consuming cell extractions. Here, we report on the ability of REIMS-based analysis to rapidly and accurately identify 153 clinical Candida isolates to species level. Both handheld bipolar REIMS and high-throughput REIMS platforms showed high levels of species classification accuracy, with 96% and 100% of isolates classified correctly to species level respectively. In addition, significantly different (FDR corrected P value < 0.05) lipids within the 600 to 1000 m/z mass range were identified, which could act as species-specific biomarkers in complex microbial communities.


Assuntos
Candida/classificação , Candida/crescimento & desenvolvimento , Espectrometria de Massas por Ionização por Electrospray/métodos , Técnicas Bacteriológicas , Candida/isolamento & purificação , Candidíase/diagnóstico , Humanos , Análise de Componente Principal , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos
15.
Anal Chem ; 88(19): 9419-9426, 2016 10 04.
Artigo em Inglês | MEDLINE | ID: mdl-27560299

RESUMO

Rapid evaporative ionization mass spectrometry (REIMS) has been shown to quickly and accurately speciate microorganisms based upon their species-specific lipid profile. Previous work by members of this group showed that the use of a hand-held bipolar probe allowed REIMS to analyze microbial cultures directly from culture plates without any prior preparation. However, this method of analysis would likely be unsuitable for a high-throughput clinical microbiology laboratory. Here, we report the creation of a customized platform that enables automated, high-throughput REIMS analysis that requires minimal user input and operation and is suitable for use in clinical microbiology laboratories. The ability of this high-throughput platform to speciate clinically important microorganisms was tested through the analysis of 375 different clinical isolates collected from distinct patient samples from 25 microbial species. After optimization of our data analysis approach, we achieved substantially similar results between the two REIMS approaches. For hand-held bipolar probe REIMS, a speciation accuracy of 96.3% was achieved, whereas for high-throughput REIMS, an accuracy of 93.9% was achieved. Thus, high-throughput REIMS offers an alternative mass spectrometry based method for the rapid and accurate identification of clinically important microorganisms in clinical laboratories without any preanalysis preparative steps.


Assuntos
Bactérias/isolamento & purificação , Fungos/isolamento & purificação , Espectrometria de Massas/métodos , Modelos Estatísticos , Análise de Componente Principal , Processos Estocásticos
16.
J Agric Food Chem ; 64(23): 4793-800, 2016 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-27167240

RESUMO

Increasingly abundant food fraud cases have brought food authenticity and safety into major focus. This study presents a fast and effective way to identify meat products using rapid evaporative ionization mass spectrometry (REIMS). The experimental setup was demonstrated to be able to record a mass spectrometric profile of meat specimens in a time frame of <5 s. A multivariate statistical algorithm was developed and successfully tested for the identification of animal tissue with different anatomical origin, breed, and species with 100% accuracy at species and 97% accuracy at breed level. Detection of the presence of meat originating from a different species (horse, cattle, and venison) has also been demonstrated with high accuracy using mixed patties with a 5% detection limit. REIMS technology was found to be a promising tool in food safety applications providing a reliable and simple method for the rapid characterization of food products.


Assuntos
Análise de Alimentos/métodos , Produtos da Carne/análise , Animais , Bovinos , Cervos , Análise de Alimentos/instrumentação , Cavalos , Limite de Detecção , Espectrometria de Massas/métodos , Carne Vermelha/análise
17.
Angew Chem Int Ed Engl ; 54(38): 11059-62, 2015 Sep 14.
Artigo em Inglês | MEDLINE | ID: mdl-26248566

RESUMO

Gastrointestinal cancers are a leading cause of mortality, accounting for 23 % of cancer-related deaths worldwide. In order to improve outcomes from these cancers, novel tissue characterization methods are needed to facilitate accurate diagnosis. Rapid evaporative ionization mass spectrometry (REIMS) is a technique developed for the in vivo classification of human tissue through mass spectrometric analysis of aerosols released during electrosurgical dissection. This ionization technique was further developed by utilizing surface induced dissociation and was integrated with an endoscopic polypectomy snare to allow in vivo analysis of the gastrointestinal tract. We tested the classification performance of this novel endoscopic REIMS method in vivo. It was shown to be capable of differentiating between healthy layers of the intestinal wall, cancer, and adenomatous polyps based on the REIMS fingerprint of each tissue type in vivo.


Assuntos
Endoscopia Gastrointestinal , Neoplasias Gastrointestinais/diagnóstico , Espectrometria de Massas/métodos , Humanos
18.
J Am Soc Mass Spectrom ; 26(1): 44-54, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25380777

RESUMO

Here we present a proof of concept cross-platform normalization approach to convert raw mass spectra acquired by distinct desorption ionization methods and/or instrumental setups to cross-platform normalized analyte profiles. The initial step of the workflow is database driven peak annotation followed by summarization of peak intensities of different ions from the same molecule. The resulting compound-intensity spectra are adjusted to a method-independent intensity scale by using predetermined, compound-specific normalization factors. The method is based on the assumption that distinct MS-based platforms capture a similar set of chemical species in a biological sample, though these species may exhibit platform-specific molecular ion intensity distribution patterns. The method was validated on two sample sets of (1) porcine tissue analyzed by laser desorption ionization (LDI), desorption electrospray ionization (DESI), and rapid evaporative ionization mass spectrometric (REIMS) in combination with Fourier transformation-based mass spectrometry; and (2) healthy/cancerous colorectal tissue analyzed by DESI and REIMS with the latter being combined with time-of-flight mass spectrometry. We demonstrate the capacity of our method to reduce MS-platform specific variation resulting in (1) high inter-platform concordance coefficients of analyte intensities; (2) clear principal component based clustering of analyte profiles according to histological tissue types, irrespective of the used desorption ionization technique or mass spectrometer; and (3) accurate "blind" classification of histologic tissue types using cross-platform normalized analyte profiles.


Assuntos
Espectrometria de Massas/métodos , Processamento de Sinais Assistido por Computador , Algoritmos , Animais , Neoplasias Colorretais/química , Rim/química , Fígado/química , Análise de Componente Principal , Reprodutibilidade dos Testes , Suínos
19.
Anal Chem ; 86(13): 6555-62, 2014 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-24896667

RESUMO

Rapid evaporative ionization mass spectrometry (REIMS) was investigated for its suitability as a general identification system for bacteria and fungi. Strains of 28 clinically relevant bacterial species were analyzed in negative ion mode, and corresponding data was subjected to unsupervised and supervised multivariate statistical analyses. The created supervised model yielded correct cross-validation results of 95.9%, 97.8%, and 100% on species, genus, and Gram-stain level, respectively. These results were not affected by the resolution of the mass spectral data. Blind identification tests were performed for strains cultured on different culture media and analyzed using different instrumental platforms which led to 97.8-100% correct identification. Seven different Escherichia coli strains were subjected to different culture conditions and were distinguishable with 88% accuracy. In addition, the technique proved suitable to distinguish five pathogenic Candida species with 98.8% accuracy without any further modification to the experimental workflow. These results prove that REIMS is sufficiently specific to serve as a culture condition-independent tool for the identification and characterization of microorganisms.


Assuntos
Bactérias/química , Infecções Bacterianas/microbiologia , Candidíase/microbiologia , Espectrometria de Massas/instrumentação , Leveduras/química , Aerossóis/química , Bactérias/classificação , Humanos , Espectrometria de Massas/economia , Fatores de Tempo , Volatilização , Leveduras/classificação
20.
Sci Transl Med ; 5(194): 194ra93, 2013 Jul 17.
Artigo em Inglês | MEDLINE | ID: mdl-23863833

RESUMO

Rapid evaporative ionization mass spectrometry (REIMS) is an emerging technique that allows near-real-time characterization of human tissue in vivo by analysis of the aerosol ("smoke") released during electrosurgical dissection. The coupling of REIMS technology with electrosurgery for tissue diagnostics is known as the intelligent knife (iKnife). This study aimed to validate the technique by applying it to the analysis of fresh human tissue samples ex vivo and to demonstrate the translation to real-time use in vivo in a surgical environment. A variety of tissue samples from 302 patients were analyzed in the laboratory, resulting in 1624 cancerous and 1309 noncancerous database entries. The technology was then transferred to the operating theater, where the device was coupled to existing electrosurgical equipment to collect data during a total of 81 resections. Mass spectrometric data were analyzed using multivariate statistical methods, including principal components analysis (PCA) and linear discriminant analysis (LDA), and a spectral identification algorithm using a similar approach was implemented. The REIMS approach differentiated accurately between distinct histological and histopathological tissue types, with malignant tissues yielding chemical characteristics specific to their histopathological subtypes. Tissue identification via intraoperative REIMS matched the postoperative histological diagnosis in 100% (all 81) of the cases studied. The mass spectra reflected lipidomic profiles that varied between distinct histological tumor types and also between primary and metastatic tumors. Thus, in addition to real-time diagnostic information, the spectra provided additional information on divergent tumor biochemistry that may have mechanistic importance in cancer.


Assuntos
Cuidados Intraoperatórios/métodos , Espectrometria de Massas/métodos , Especificidade de Órgãos , Análise Discriminante , Humanos , Cuidados Intraoperatórios/instrumentação , Espectrometria de Massas/instrumentação , Análise Multivariada , Metástase Neoplásica , Neoplasias/metabolismo , Neoplasias/cirurgia , Fosfolipídeos/análise , Fosfolipídeos/química , Análise de Componente Principal , Reprodutibilidade dos Testes , Volatilização