Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Appl Spectrosc ; 78(3): 268-276, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38112337

RESUMO

Surface-enhanced Raman spectroscopy (SERS) is a highly sensitive technique that can assist in trace analysis for biomedical, diagnostic, and environmental applications. However, a major limitation of SERS is surface contamination of the substrates used, which can complicate the spectral reproducibility, limits of detection, and detection of unknown analytes. This is especially prevalent with commercially available substrates as shipping under a controlled and clean environment is difficult. Here we report a method using dilute bleach solutions to remove surface contamination from commercially available substrates consisting of gold-coated nanopillar arrays that maintains functionality. The results show that this method can be used to remove background signals associated with typical surface contamination in commercially available substrates as well as remove thiolated self-assembled monolayers (SAMs). Results indicate the bleach oxidizes the surface contaminants, which can then be easily washed away. Although the metallic surface also becomes oxidized in this process, the surface can be reduced without loss of SERS activity. The SERS intensity of SAMs improved following bleach treatment across all concentrations studied.

2.
Anal Methods ; 14(14): 1387-1395, 2022 04 07.
Artigo em Inglês | MEDLINE | ID: mdl-35274114

RESUMO

Lentiviruses are commonly used to deliver genetic code into host cells for biomedical applications, such as gene therapy, pharmaceuticals, and vaccine development. Knowing the infectious titer of these virus particles is critical for development in these areas. Current methods of determining viral titer often require cell culture, where a cell is infected and the inserted genetic code is expressed in a known number of cells, which can require days or weeks to prepare and analyze samples. To provide a more rapid method of determining viral titer, the use of surface enhanced Raman spectroscopy (SERS) was explored. SERS provides both chemical and structural information by using plasmonic metallic nanostructures to amplify the Raman signal. Two different lentiviruses, one with a vector encoding a GFP gene and the same virus without the GFP gene included, were analyzed by SERS in viral production media at various concentrations. The SERS response was demonstrated to be sensitive to the incorporation of the GFP gene into the viral vector. Chemometric analysis using multivariate curve resolution (MCR) was able to identify a component in the observed SERS spectra that correlated with the concentration of GFP containing virus particles. Using the MCR model and the SERS response, the viral titer of lentivirus encoding for GFP was determined. The viral titer determined by SERS agreed well with expression of the GFP in infected cells. The SERS response using different metals and excitation wavelengths was also explored. Overall, this work demonstrates the utility of SERS for rapid determination of lentiviral titer.


Assuntos
Nanoestruturas , Análise Espectral Raman , Vetores Genéticos , Lentivirus/genética , Vírion
3.
J Pharm Sci ; 110(12): 3786-3793, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34364901

RESUMO

Application of Raman spectroscopy as a T cell characterization tool supporting cell therapy drug product development has been evaluated. Statistically significant correlations between a set of Raman signals and established flow cytometry markers associated with apoptosis of T cells detected during drug product cryopreservation are presented in this study. Our study results demonstrate the potential of Raman spectroscopy for label-free measurements of T cell characteristics relevant to cell therapy product design and process control.


Assuntos
Preparações Farmacêuticas , Análise Espectral Raman , Apoptose , Morte Celular , Terapia Baseada em Transplante de Células e Tecidos , Projetos Piloto , Análise Espectral Raman/métodos , Linfócitos T
4.
Bioprocess Biosyst Eng ; 43(8): 1415-1429, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32303846

RESUMO

Multiple process analytical technology (PAT) tools are now being applied in tandem for cell culture. Research presented used two in-line probes, capacitance for a dynamic feeding strategy and Raman spectroscopy for real-time monitoring. Data collected from eight batches at the 15,000 L scale were used to develop process models. Raman spectroscopic data were modelled using Partial Least Squares (PLS) by two methods-(1) use of the full dataset and (2) split the dataset based on the capacitance feeding strategy. Root mean square error of prediction (RMSEP) for the first model method of capacitance was 1.54 pf/cm and the second modelling method was 1.40 pf/cm. The second Raman method demonstrated results within expected process limits for capacitance and a 0.01% difference in total nutrient feed compared to the capacitance probe. Additional variables modelled using Raman spectroscopy were viable cell density (VCD), viability, average cell diameter, and viable cell volume (VCV).


Assuntos
Técnicas de Cultura Celular por Lotes , Modelos Biológicos , Análise Espectral Raman
5.
Biotechnol Prog ; 36(4): e2977, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32012476

RESUMO

The Food and Drug Administration (FDA) initiative of Process Analytical Technology (PAT) encourages the monitoring of biopharmaceutical manufacturing processes by innovative solutions. Raman spectroscopy and the chemometric modeling tool partial least squares (PLS) have been applied to this aim for monitoring cell culture process variables. This study compares the chemometric modeling methods of Support Vector Machine radial (SVMr), Random Forests (RF), and Cubist to the commonly used linear PLS model for predicting cell culture components-glucose, lactate, and ammonia. This research is performed to assess whether the use of PLS as standard practice is justified for chemometric modeling of Raman spectroscopy and cell culture data. Model development data from five small-scale bioreactors (2 × 1 L and 3 × 5 L) using two Chinese hamster ovary (CHO) cell lines were used to predict against a manufacturing scale bioreactor (2,000 L). Analysis demonstrated that Cubist predictive models were better for average performance over PLS, SVMr, and RF for glucose, lactate, and ammonia. The root mean square error of prediction (RMSEP) of Cubist modeling was acceptable for the process concentration ranges of glucose (1.437 mM), lactate (2.0 mM), and ammonia (0.819 mM). Interpretation of variable importance (VI) results theorizes the potential advantages of Cubist modeling in avoiding interference of Raman spectral peaks. Predictors/Raman wavenumbers (cm-1 ) of interest for individual variables are X1139-X1141 for glucose, X846-X849 for lactate, and X2941-X2943 for ammonia. These results demonstrate that other beneficial chemometric models are available for use in monitoring cell culture with Raman spectroscopy.


Assuntos
Técnicas de Cultura Celular por Lotes , Meios de Cultura/metabolismo , Metaboloma/genética , Análise Espectral Raman , Animais , Células CHO/química , Células CHO/metabolismo , Cricetinae , Cricetulus , Meios de Cultura/química
6.
Biotechnol Bioeng ; 117(1): 146-156, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31631327

RESUMO

Raman spectroscopy is a robust, well-established tool utilized for measuring important cell culture process variables for example, feed, metabolites, and biomass in real-time. This study further expands the functionality of in-line Raman spectroscopy coupled with partial least squares (PLS) regression modelling to develop a pH measurement tool. Cell line specific models were developed to enhance the robustness for processes with different pH setpoints, deadbands, and cellular metabolism. The modelling strategy further improved robustness by reducing the temporal complexity of pH shifts by splitting data sets into two time zones reflective of major changes in pH. In addition, models were developed to assess if lactate and partial pressure of carbon dioxide (pCO2 ) could be used in a PLS model for pH. Splitting the data sets into early and late for the process resulted in errors of 0.035 pH and 0.034 pH for the two respective Raman cell lines models which was within acceptance criteria. The lactate and pCO2 PLS model with values provided by Raman models had a further 0.001 pH error reduction. This study illustrates the potential to eliminate off-line samples to correct for in-line measurements of pH and further illustrates the capabilities of Raman to measure additional process variables.


Assuntos
Reatores Biológicos , Técnicas de Cultura de Células , Concentração de Íons de Hidrogênio , Análise Espectral Raman/métodos , Animais , Células CHO , Dióxido de Carbono/metabolismo , Técnicas de Cultura de Células/instrumentação , Técnicas de Cultura de Células/métodos , Cricetinae , Cricetulus , Ácido Láctico/metabolismo
7.
Langmuir ; 28(21): 8238-43, 2012 May 29.
Artigo em Inglês | MEDLINE | ID: mdl-22533814

RESUMO

Drug release from and coating morphology on a CYPHER sirolimus-eluting coronary stent (SES) during in vitro elution were studied by correlated confocal Raman and atomic force microscopy (CRM and AFM, respectively). Chemical surface and subsurface maps of the SES were generated in the same region of interest by CRM and were correlated with surface topography measured by AFM at different elution times. For the first time, a direct correlation between drug-rich regions and the coating morphology was made on a drug-eluting medical device, linking drug release with pore formation, pore throats, and pore networks. Drug release was studied on a drug-eluting stent (DES) system with a multicomponent carrier matrix (poly(n-butyl methacrylate) [PBMA] and poly(ethylene-co-vinyl acetate) [PEVA]). The polymer was found to rearrange postelution because confluence of the carrier polymer matrix reconstituted the voids created by drug release.


Assuntos
Stents Farmacológicos , Metacrilatos/química , Polivinil/química , Microscopia de Força Atômica , Análise Espectral Raman
8.
Proc Natl Acad Sci U S A ; 105(25): 8513-8, 2008 Jun 24.
Artigo em Inglês | MEDLINE | ID: mdl-18559857

RESUMO

Collagens are integral structural proteins in animal tissues and play key functional roles in cellular modulation. We sought to discover collagen model peptides (CMPs) that would form triple helices and self-assemble into supramolecular fibrils exhibiting collagen-like biological activity without preorganizing the peptide chains by covalent linkages. This challenging objective was accomplished by placing aromatic groups on the ends of a representative 30-mer CMP, (GPO)(10), as with l-phenylalanine and l-pentafluorophenylalanine in 32-mer 1a. Computational studies on homologous 29-mers 1a'-d' (one less GPO), as pairs of triple helices interacting head-to-tail, yielded stabilization energies in the order 1a' > 1b' > 1c' > 1d', supporting the hypothesis that hydrophobic aromatic groups can drive CMP self-assembly. Peptides 1a-d were studied comparatively relative to structural properties and ability to stimulate human platelets. Although each 32-mer formed stable triple helices (CD) spectroscopy, only 1a and 1b self-assembled into micrometer-scale fibrils. Light microscopy images for 1a depicted long collagen-like fibrils, whereas images for 1d did not. Atomic force microscopy topographical images indicated that 1a and 1b self-organize into microfibrillar species, whereas 1c and 1d do not. Peptides 1a and 1b induced the aggregation of human blood platelets with a potency similar to type I collagen, whereas 1c was much less effective, and 1d was inactive (EC(50) potency: 1a/1b >> 1c > 1d). Thus, 1a and 1b spontaneously self-assemble into thrombogenic collagen-mimetic materials because of hydrophobic aromatic interactions provided by the special end-groups. These findings have important implications for the design of biofunctional CMPs.


Assuntos
Colágenos Fibrilares/química , Peptídeos/química , Trombina/metabolismo , Biomimética , Dicroísmo Circular , Colágenos Fibrilares/metabolismo , Humanos , Interações Hidrofóbicas e Hidrofílicas , Microscopia de Força Atômica , Modelos Moleculares , Peptídeos/síntese química , Trombina/química
9.
Anal Chem ; 80(13): 4853-9, 2008 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-18510342

RESUMO

Multivariate data analysis was applied to confocal Raman measurements on stents coated with the polymers and drug used in the CYPHER Sirolimus-eluting Coronary Stents. Partial least-squares (PLS) regression was used to establish three independent calibration curves for the coating constituents: sirolimus, poly(n-butyl methacrylate) [PBMA], and poly(ethylene-co-vinyl acetate) [PEVA]. The PLS calibrations were based on average spectra generated from each spatial location profiled. The PLS models were tested on six unknown stent samples to assess accuracy and precision. The wt % difference between PLS predictions and laboratory assay values for sirolimus was less than 1 wt % for the composite of the six unknowns, while the polymer models were estimated to be less than 0.5 wt % difference for the combined samples. The linearity and specificity of the three PLS models were also demonstrated with the three PLS models. In contrast to earlier univariate models, the PLS models achieved mass balance with better accuracy. This analysis was extended to evaluate the spatial distribution of the three constituents. Quantitative bitmap images of drug-eluting stent coatings are presented for the first time to assess the local distribution of components.


Assuntos
Stents Farmacológicos , Metacrilatos/análise , Microscopia Confocal/métodos , Polivinil/análise , Sirolimo/análise , Análise Espectral Raman/métodos , Calibragem , Processamento de Imagem Assistida por Computador/métodos , Modelos Estatísticos , Análise Multivariada , Análise de Regressão
10.
J Biomed Mater Res A ; 87(1): 272-81, 2008 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-18306306

RESUMO

An atomic force microscopy (AFM) method was developed to quantify the adhesion forces between and cohesive forces within the layers of a drug-eluting stent (DES). Surface pairs representing both the individual components and the complete chemistry of each layer within the DES were prepared. As a model, the CYPHER Sirolimus-eluting Coronary Stent was studied. This DES consists of a stainless steel stent substrate, a parylene C primer layer, and a drug-eluting layer that contains poly(ethylene-co-vinyl acetate), poly(n-butyl methacrylate), and sirolimus (rapamycin). Coated AFM tips and two-dimensional substrates or coupons, which act as surrogates to the CYPHER Stent, were prepared and characterized. The force-displacement measurements were conducted to evaluate the adhesion between the middle parylene C layer and the 316L stainless steel substrate, the adhesion between the parylene C layer and the outer drug-eluting layer, and the cohesion between the three constituents of the drug-eluting layer. The average adhesion forces between the parylene C to drug layer varied from 88 to 167 nN, and the drug layer-to-drug layer interactions were between 194 and 486 nN within the model CYPHER Stent coating. All the adhesion forces measured were larger than those observed for gold-gold interactions, which yielded a pull of force of 19 nN (Zong et al., J Appl Phys 2006;100:104313-104323).


Assuntos
Materiais Revestidos Biocompatíveis/química , Stents Farmacológicos , Polímeros/química , Sirolimo/química , Aço Inoxidável/química , Xilenos/química , Adesividade , Antibacterianos/química , Teste de Materiais , Microscopia de Força Atômica
11.
Anal Chem ; 78(20): 7186-90, 2006 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-17037919

RESUMO

Temperature gradient focusing (TGF) is a recently developed technique for the simultaneous concentration and electrophoretic separation of ionic analytes in microfluidic channels. One drawback to TGF as it has previously been described is the limited peak capacity; only a small number of analyte peaks (approximately 2-3) can be simultaneously focused and separated. In this paper, we report on a variation of the TGF method whereby the bulk flow rate is varied over time so that a large number of analytes can be sequentially focused, moved past a fixed detection point, and flushed to waste. In addition to improved peak capacity, the detection limits of the scanning TGF method can be adjusted on-the-fly, as needed for different samples. Finally, scanning TGF provides a technique by which high-resolution, high-peak-capacity electrophoretic separations can be performed in simple, straight, and short microfluidic channels.

12.
Langmuir ; 21(23): 10459-67, 2005 Nov 08.
Artigo em Inglês | MEDLINE | ID: mdl-16262306

RESUMO

Fast transient microboiling has been characterized on modified gold microheaters using a novel laser strobe microscopy technique. Microheater surfaces of different hydrophobicity were prepared using self-assembled monolayers of hexadecane thiol (hydrophobic) and 16-mercaptohexadecanol (hydrophilic) as well as the naturally hydrophilic bare gold surface. The microheater was immersed in a pool of water, and a 5-micros voltage pulse to the heater was applied, causing superheating of the water and nucleation of a vapor bubble on the heater surface. Light from a pulsed Nd:Yag laser was configured to illuminate and image the sample through a microscope assembly. The timing of the short duration (7.5 ns) laser flash was varied with respect to the voltage pulse applied to the heater to create a series of images illuminated by the flash of the laser. These images were correlated with the transient resistance change of the heater both during and after the voltage pulse. It was found that hydrophobic surfaces produced a bubble that nucleated at an earlier time, grew more slowly to a smaller maximum size, and collapsed more rapidly than bubbles formed on hydrophilic surfaces.

13.
Anal Chem ; 76(24): 7243-9, 2004 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-15595865

RESUMO

A new technique is demonstrated for the simultaneous concentration and high-resolution separation of chiral compounds. With temperature gradient focusing, a combination of a temperature gradient, an applied electric field, and a buffer with a temperature-dependent ionic strength is used to cause analytes to move to equilibrium, zero-velocity points along a microchannel or capillary. Different analytes are thus separated spatially and concentrated in a manner that resembles isoelectric focusing but that is applicable to a greater variety of analytes including small chiral drug molecules. Chiral separations are accomplished by the addition of a chiral selector, which causes the different enantiomers of an analyte to focus at different positions along a microchannel or capillary. This new technique is demonstrated to provide high performance in a number of areas desirable for chiral separations including rapid separation optimization and method development, facile reversal of peak order (desirable for analysis of trace enantiomeric impurities), and high resolving power (comparable to capillary electrophoresis) in combination with greater than 1000-fold concentration enhancement enabling improved detection limits. In addition, chiral temperature gradient focusing allows for real-time monitoring of the interaction of chiral analyte molecules with chiral selectors that could potentially be applied to the study of other molecular interactions. Finally, unlike CE, which requires long channels or capillaries for high-resolution separations, separations of equivalent resolution can be performed with TGF in very short microchannels (mm); thus, TGF is inherently much more suited to miniaturization and integration into lab-on-a-chip-devices.


Assuntos
Eletroforese Capilar/métodos , Soluções Tampão , Focalização Isoelétrica , Miniaturização , Preparações Farmacêuticas/isolamento & purificação , Estereoisomerismo , Temperatura
14.
J Am Chem Soc ; 126(41): 13474-9, 2004 Oct 20.
Artigo em Inglês | MEDLINE | ID: mdl-15479104

RESUMO

Two types of DNA hybridization assays are demonstrated with temperature gradient focusing (TGF) and peptide nucleic acids (PNAs). In TGF, the application of a controlled temperature gradient along the length of a microchannel filled with an appropriate temperature-dependent buffer results in the formation of a gradient in both the electric field and electrophoretic velocity. Ionic species move in this gradient and concentrate at a unique point where the total velocity sums to zero. The first assay is a mixing assay in which PNA is allowed to flow through spatially focused DNA targets within a capillary. The second assay detects single base pair mutations (SBPM) by monitoring the fluorescence intensity of PNA/DNA duplexes as a function of temperature within the capillary. The SBPM analysis can be performed in less than 5 min with 100-fold more dilute analyte compared to conventional UV melting measurements.


Assuntos
DNA de Cadeia Simples/química , Hibridização de Ácido Nucleico/métodos , Ácidos Nucleicos Peptídicos/química , Soluções Tampão , Análise Mutacional de DNA/métodos , Microscopia de Fluorescência , Temperatura
15.
J Am Chem Soc ; 126(7): 1936-7, 2004 Feb 25.
Artigo em Inglês | MEDLINE | ID: mdl-14971917

RESUMO

This report describes a new method for the concentration and separation of neutral and/or hydrophobic analytes based on a combination of the analytes' electrophoretic mobility, and affinity for partitioning into a micellar phase. Micellar affinity gradient focusing (MAGF) works by creating a gradient in the micellar retention factor. An electric field is applied along the channel to cause the (negatively charged) micelles to move from the region of high retention to the region of low retention, and the mobile phase is forced to move from the region of low retention to the region of high retention. Consequently, the analyte moves into the gradient region from both directions where it is concentrated at a point where its total velocity is zero. Different analytes, which interact differently with the micelles, will have zero total velocity at different points along the gradient, and will thereby be simultaneously concentrated and separated.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...