Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 51
Filtrar
1.
Int J Dermatol ; 2024 Apr 11.
Artigo em Inglês | MEDLINE | ID: mdl-38602089

RESUMO

BACKGROUND: Erythropoietic protoporphyria (EPP) causes painful light sensitivity, limiting quality of life. Our objective was to develop and validate a wearable light exposure device and correlate measurements with light sensitivity in EPP to predict and prevent symptoms. METHODS: A wearable light dosimeter was developed to capture light doses of UVA, blue, and red wavelengths. A prospective observational pilot study was performed in which five EPP patients wore two light dosimeters for 3 weeks, one as a watch, and one as a shirt clip. RESULTS: Standard deviation (SD) increases from the mean in the daily blue light dose increased the odds ratio (OR) for symptom risk more than the self-reported outdoor time (OR 2.76 vs. 2.38) or other wavelengths, and a one SD increase from the mean in the daily blue light wristband device dose increased the OR for symptom risk more than the daily blue light shirt clip (OR 2.45 vs. 1.62). The area under the receiver operator curve for the blue light wristband dose was 0.78, suggesting 78% predictive accuracy. CONCLUSION: These data demonstrate that wearable blue light dosimetry worn as a wristband is a promising method for measuring light exposure and predicting and preventing symptoms in EPP.

2.
Neuron ; 2024 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-38537641

RESUMO

Comprehensive, continuous quantitative monitoring of intricately orchestrated physiological processes and behavioral states in living organisms can yield essential data for elucidating the function of neural circuits under healthy and diseased conditions, for defining the effects of potential drugs and treatments, and for tracking disease progression and recovery. Here, we report a wireless, battery-free implantable device and a set of associated algorithms that enable continuous, multiparametric physio-behavioral monitoring in freely behaving small animals and interacting groups. Through advanced analytics approaches applied to mechano-acoustic signals of diverse body processes, the device yields heart rate, respiratory rate, physical activity, temperature, and behavioral states. Demonstrations in pharmacological, locomotor, and acute and social stress tests and in optogenetic studies offer unique insights into the coordination of physio-behavioral characteristics associated with healthy and perturbed states. This technology has broad utility in neuroscience, physiology, behavior, and other areas that rely on studies of freely moving, small animal models.

3.
Nat Med ; 29(12): 3137-3148, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37973946

RESUMO

The human body generates various forms of subtle, broadband acousto-mechanical signals that contain information on cardiorespiratory and gastrointestinal health with potential application for continuous physiological monitoring. Existing device options, ranging from digital stethoscopes to inertial measurement units, offer useful capabilities but have disadvantages such as restricted measurement locations that prevent continuous, longitudinal tracking and that constrain their use to controlled environments. Here we present a wireless, broadband acousto-mechanical sensing network that circumvents these limitations and provides information on processes including slow movements within the body, digestive activity, respiratory sounds and cardiac cycles, all with clinical grade accuracy and independent of artifacts from ambient sounds. This system can also perform spatiotemporal mapping of the dynamics of gastrointestinal processes and airflow into and out of the lungs. To demonstrate the capabilities of this system we used it to monitor constrained respiratory airflow and intestinal motility in neonates in the neonatal intensive care unit (n = 15), and to assess regional lung function in patients undergoing thoracic surgery (n = 55). This broadband acousto-mechanical sensing system holds the potential to help mitigate cardiorespiratory instability and manage disease progression in patients through continuous monitoring of physiological signals, in both the clinical and nonclinical setting.


Assuntos
Unidades de Terapia Intensiva Neonatal , Recém-Nascido , Humanos , Monitorização Fisiológica
4.
Nat Biomed Eng ; 7(10): 1252-1269, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37106153

RESUMO

Fully implantable wireless systems for the recording and modulation of neural circuits that do not require physical tethers or batteries allow for studies that demand the use of unconstrained and freely behaving animals in isolation or in social groups. Moreover, feedback-control algorithms that can be executed within such devices without the need for remote computing eliminate virtual tethers and any associated latencies. Here we report a wireless and battery-less technology of this type, implanted subdermally along the back of freely moving small animals, for the autonomous recording of electroencephalograms, electromyograms and body temperature, and for closed-loop neuromodulation via optogenetics and pharmacology. The device incorporates a system-on-a-chip with Bluetooth Low Energy for data transmission and a compressed deep-learning module for autonomous operation, that offers neurorecording capabilities matching those of gold-standard wired systems. We also show the use of the implant in studies of sleep-wake regulation and for the programmable closed-loop pharmacological suppression of epileptic seizures via feedback from electroencephalography. The technology can support a broader range of applications in neuroscience and in biomedical research with small animals.

5.
Nat Biomed Eng ; 7(10): 1215-1228, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37037964

RESUMO

Devices for monitoring blood haemodynamics can guide the perioperative management of patients with cardiovascular disease. Current technologies for this purpose are constrained by wired connections to external electronics, and wireless alternatives are restricted to monitoring of either blood pressure or blood flow. Here we report the design aspects and performance parameters of an integrated wireless sensor capable of implantation in the heart or in a blood vessel for simultaneous measurements of pressure, flow rate and temperature in real time. The sensor is controlled via long-range communication through a subcutaneously implanted and wirelessly powered Bluetooth Low Energy system-on-a-chip. The device can be delivered via a minimally invasive transcatheter procedure or it can be mounted on a passive medical device such as a stent, as we show for the case of the pulmonary artery in a pig model and the aorta and left ventricle in a sheep model, where the device performs comparably to clinical tools for monitoring of blood flow and pressure. Battery-less and wireless devices such as these that integrate capabilities for flow, pressure and temperature sensing offer the potential for continuous monitoring of blood haemodynamics in patients.

6.
Adv Healthc Mater ; 12(4): e2202021, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36337006

RESUMO

Accurate measurements of skin hydration are of great interest to dermatological science and clinical practice. This parameter serves as a relevant surrogate of skin barrier function, a key representative benchmark for overall skin health. The skin hydration sensor (SHS) is a soft, skin-interfaced wireless system that exploits a thermal measurement method, as an alternative to conventional impedance-based hand-held probes. This study presents multiple strategies for maximizing the sensitivity and reliability of this previously reported SHS platform. An in-depth analysis of the thermal physics of the measurement process serves as the basis for structural optimizations of the electronics and the interface to the skin. Additional engineering advances eliminate variabilities associated with manual use of the device and with protocols for the measurement. The cumulative effect is an improvement in sensitivity by 135% and in repeatability by 36% over previously reported results. Pilot trials on more than 200 patients in a dermatology clinic validate the practical utility of the sensor for fast, reliable measurements.


Assuntos
Dispositivos Eletrônicos Vestíveis , Humanos , Reprodutibilidade dos Testes , Pele/química , Eletrônica/métodos , Tecnologia sem Fio
7.
Nat Commun ; 13(1): 6518, 2022 10 31.
Artigo em Inglês | MEDLINE | ID: mdl-36316354

RESUMO

Physically transient forms of electronics enable unique classes of technologies, ranging from biomedical implants that disappear through processes of bioresorption after serving a clinical need to internet-of-things devices that harmlessly dissolve into the environment following a relevant period of use. Here, we develop a sustainable manufacturing pathway, based on ultrafast pulsed laser ablation, that can support high-volume, cost-effective manipulation of a diverse collection of organic and inorganic materials, each designed to degrade by hydrolysis or enzymatic activity, into patterned, multi-layered architectures with high resolution and accurate overlay registration. The technology can operate in patterning, thinning and/or cutting modes with (ultra)thin eco/bioresorbable materials of different types of semiconductors, dielectrics, and conductors on flexible substrates. Component-level demonstrations span passive and active devices, including diodes and field-effect transistors. Patterning these devices into interconnected layouts yields functional systems, as illustrated in examples that range from wireless implants as monitors of neural and cardiac activity, to thermal probes of microvascular flow, and multi-electrode arrays for biopotential sensing. These advances create important processing options for eco/bioresorbable materials and associated electronic systems, with immediate applicability across nearly all types of bioelectronic studies.


Assuntos
Implantes Absorvíveis , Eletrônica , Semicondutores , Eletrodos , Lasers
8.
IISE Trans Occup Ergon Hum Factors ; 10(4): 173-181, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36181238

RESUMO

OCCUPATIONAL APPLICATIONSThis case report shares an approach to ergonomics kaizen events, that is, using workplace teams in a concentrated activity to make as many improvements as possible in a few days in a given work area. This report provides an overview of (1) the structure of this particular approach, (2) the average number of improvements implemented, and (3) guidance for smaller organizations on less-elaborate approaches. The value of kaizen events is described regarding cultural change and creating habits of continual improvement in daily life, whether at work or at home. Practitioners may benefit from the details in this report, such as features important for success and the schedule for a four-day event. Researchers may benefit from familiarity with a nontraditional organizational structure. Furthermore, the kaizen approach may lend itself to university-enterprise interactions, including a changing context in which research topics can be formulated and results applied.


Assuntos
Ergonomia , Local de Trabalho , Humanos , Ergonomia/métodos
10.
Nat Commun ; 13(1): 5571, 2022 09 22.
Artigo em Inglês | MEDLINE | ID: mdl-36137999

RESUMO

In vivo optogenetics and photopharmacology are two techniques for controlling neuronal activity that have immense potential in neuroscience research. Their applications in tether-free groups of animals have been limited in part due to tools availability. Here, we present a wireless, battery-free, programable multilateral optofluidic platform with user-selected modalities for optogenetics, pharmacology and photopharmacology. This system features mechanically compliant microfluidic and electronic interconnects, capabilities for dynamic control over the rates of drug delivery and real-time programmability, simultaneously for up to 256 separate devices in a single cage environment. Our behavioral experiments demonstrate control of motor behaviors in grouped mice through in vivo optogenetics with co-located gene delivery and controlled photolysis of caged glutamate. These optofluidic systems may expand the scope of wireless techniques to study neural processing in animal models.


Assuntos
Neurociências , Optogenética , Animais , Encéfalo/fisiologia , Glutamatos , Camundongos , Optogenética/métodos , Tecnologia sem Fio
11.
Front Psychiatry ; 13: 777124, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35722588

RESUMO

Objectives: People with mental illnesses are overrepresented in the U.S. prison population. It is well established that incarceration for this population poses physical and mental health risks including greater likelihood of victimization and suicide compared to the general prison population. Yet, research is less clear about how staff and services shape these prison experiences. The aim of this study was to examine how people with mental illnesses experience incarceration through interactions with correctional officers and treatment staff and their use of physical and mental health care services. Methods: This project utilized a non-experimental design and qualitative research approach to address the research aims. Adults with mental illnesses who were formerly incarcerated were recruited from three different sites in the Midwest and East Coast. Participants completed an in-depth interview and brief survey on health histories. Data were analyzed using descriptive statistics and the framework method for qualitative analysis. Results: Participants (n = 43) identified challenges to utilizing health and mental health care including perceived access and quality of mental health, medical, or substance use treatments obtained during prison as well as participant's willingness to engage in services. Access to health care was marked by cumbersome procedures required for service use requests and inadequate staffing. Participants reported mixed experiences with medical and mental health staff ranging from experiencing kindness to feeling staff did not believe them. Participants perceived most correctional officers as exhibiting professionalism while some enacted stigma and created additional stressors. Conclusion: Interactions with correctional staff and health care services have the potential to buffer the stressors and risks inherent in prisons for people with mental illnesses. Perceptions from participants suggest both individual- and systems-level opportunities for intervention to better support people with mental illnesses in prison.

12.
Science ; 376(6596): 1006-1012, 2022 05 27.
Artigo em Inglês | MEDLINE | ID: mdl-35617386

RESUMO

Temporary postoperative cardiac pacing requires devices with percutaneous leads and external wired power and control systems. This hardware introduces risks for infection, limitations on patient mobility, and requirements for surgical extraction procedures. Bioresorbable pacemakers mitigate some of these disadvantages, but they demand pairing with external, wired systems and secondary mechanisms for control. We present a transient closed-loop system that combines a time-synchronized, wireless network of skin-integrated devices with an advanced bioresorbable pacemaker to control cardiac rhythms, track cardiopulmonary status, provide multihaptic feedback, and enable transient operation with minimal patient burden. The result provides a range of autonomous, rate-adaptive cardiac pacing capabilities, as demonstrated in rat, canine, and human heart studies. This work establishes an engineering framework for closed-loop temporary electrotherapy using wirelessly linked, body-integrated bioelectronic devices.


Assuntos
Implantes Absorvíveis , Estimulação Cardíaca Artificial , Marca-Passo Artificial , Cuidados Pós-Operatórios , Tecnologia sem Fio , Animais , Cães , Frequência Cardíaca , Humanos , Cuidados Pós-Operatórios/instrumentação , Ratos
13.
Nat Protoc ; 17(4): 1073-1096, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-35173306

RESUMO

Wireless battery-free optogenetic devices enable behavioral neuroscience studies in groups of animals with minimal interference to natural behavior. Real-time independent control of optogenetic stimulation through near-field communication dramatically expands the realm of applications of these devices in broad contexts of neuroscience research. Dissemination of these tools with advanced functionalities to the neuroscience community requires protocols for device manufacturing and experimental implementation. This protocol describes detailed procedures for fabrication, encapsulation and implantation of recently developed advanced wireless devices in head- and back-mounted forms. In addition, procedures for standard implementation of experimental systems in mice are provided. This protocol aims to facilitate the application of wireless optogenetic devices in advanced optogenetic experiments involving groups of freely moving rodents and complex environmental designs. The entire protocol lasts ~3-5 weeks.


Assuntos
Neurociências , Optogenética , Animais , Camundongos , Optogenética/métodos , Tecnologia sem Fio
14.
Ann LGBTQ Public Popul Health ; 3(2): 129-134, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37885620

RESUMO

Transgender and gender diverse (TGD) adolescents and young adults (AYA) face heightened risks of cancer due to cissexism and transphobia in healthcare, low cancer screening rates, limited knowledge and awareness of cancer risk and screenings, poor healthcare experiences, and exposure to sexually transmitted infections (STIs). Despite this, TGD AYA cancer risk is relatively unexamined in oncology research. To intervene early and mitigate risk, we require holistic understandings of cancer risk among TGD AYA. This research brief engages with an interdisciplinary knowledge base to identify gaps and limitations warranting critical attention by TGD AYA and cancer scholars. The current literature on TGD AYA risks for cancer are explored with specific attention to the social environment and its impact on cancer risk. The brief ends with a call to action for a paradigmatic shift to promote inclusive, innovative, and interdisciplinary cancer research with TGD AYA.

15.
Nat Mater ; 20(11): 1559-1570, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34326506

RESUMO

Flexible electronic/optoelectronic systems that can intimately integrate onto the surfaces of vital organ systems have the potential to offer revolutionary diagnostic and therapeutic capabilities relevant to a wide spectrum of diseases and disorders. The critical interfaces between such technologies and living tissues must provide soft mechanical coupling and efficient optical/electrical/chemical exchange. Here, we introduce a functional adhesive bioelectronic-tissue interface material, in the forms of mechanically compliant, electrically conductive, and optically transparent encapsulating coatings, interfacial layers or supporting matrices. These materials strongly bond both to the surfaces of the devices and to those of different internal organs, with stable adhesion for several days to months, in chemistries that can be tailored to bioresorb at controlled rates. Experimental demonstrations in live animal models include device applications that range from battery-free optoelectronic systems for deep-brain optogenetics and subdermal phototherapy to wireless millimetre-scale pacemakers and flexible multielectrode epicardial arrays. These advances have immediate applicability across nearly all types of bioelectronic/optoelectronic system currently used in animal model studies, and they also have the potential for future treatment of life-threatening diseases and disorders in humans.


Assuntos
Implantes Absorvíveis , Adesivos , Animais , Condutividade Elétrica , Eletrônica
16.
Nat Biotechnol ; 39(10): 1228-1238, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34183859

RESUMO

Temporary cardiac pacemakers used in periods of need during surgical recovery involve percutaneous leads and externalized hardware that carry risks of infection, constrain patient mobility and may damage the heart during lead removal. Here we report a leadless, battery-free, fully implantable cardiac pacemaker for postoperative control of cardiac rate and rhythm that undergoes complete dissolution and clearance by natural biological processes after a defined operating timeframe. We show that these devices provide effective pacing of hearts of various sizes in mouse, rat, rabbit, canine and human cardiac models, with tailored geometries and operation timescales, powered by wireless energy transfer. This approach overcomes key disadvantages of traditional temporary pacing devices and may serve as the basis for the next generation of postoperative temporary pacing technology.


Assuntos
Implantes Absorvíveis , Marca-Passo Artificial , Animais , Bloqueio Atrioventricular/terapia , Modelos Animais de Doenças , Cães , Desenho de Equipamento , Humanos , Camundongos , Coelhos , Ratos , Tecnologia sem Fio
17.
JMIR Mhealth Uhealth ; 9(5): e25895, 2021 05 06.
Artigo em Inglês | MEDLINE | ID: mdl-33955844

RESUMO

BACKGROUND: Melanoma is attributable to predisposing phenotypical factors, such as skin that easily sunburns and unprotected exposure to carcinogenic UV radiation. Reducing the proportion of young adults who get sunburned may reduce the incidence of melanoma, a deadly form of skin cancer. Advances in technology have enabled the delivery of real-time UV light exposure and content-relevant health interventions. OBJECTIVE: This study aims to examine the feasibility of young adults performing the following tasks daily: wearing a UV dosimeter, receiving text messages and real-time UV-B doses on their smartphone, and responding to daily web-based surveys about sunburn and sun protection. METHODS: Young adults aged 18-39 years (n=42) were recruited in the United States in June 2020 via social media. Participants received the UV Guard sun protection system, which consisted of a UV dosimeter and a smartphone app. During 3 consecutive periods, intervention intensity increased as follows: real-time UV-B dose; UV-B dose and daily behavioral facilitation text messages; and UV-B dose, goal setting, and daily text messages to support self-efficacy and self-regulation. Data were self-reported through daily web-based surveys for 28 days, and UV-B doses were transmitted to cloud-based storage. RESULTS: Patients' median age was 22 years (IQR 20, 29), and all patients had sun-sensitive skin. Sunburns were experienced during the study by fewer subjects (n=18) than those in the preceding 28 days (n=30). In July and August, the face was the most commonly sunburned area among 13 body locations; 52% (22/42) of sunburns occurred before the study and 45% (19/42) occurred during the study. The mean daily UV-B dose decreased during the 3 periods; however, this was not statistically significant. Young adults were most often exercising outdoors from 2 to 6 PM, walking from 10 AM to 6 PM, and relaxing from noon to 2 PM. Sunburn was most often experienced during exercise (odds ratio [OR] 5.65, 95% CI 1.60-6.10) and relaxation (OR 3.69, 95% CI 1.03-4.67) relative to those that did not exercise or relax in each category. The self-reported exit survey indicated that participants felt that they spent less time outdoors this summer compared to the last summer because of the COVID-19 pandemic and work. In addition, 38% (16/42) of the participants changed their use of sun protection based on their app-reported UV exposure, and 48% (20/42) shifted the time they went outside to periods with less-intense UV exposure. A total of 79% (33/42) of the participants were willing to continue using the UV Guard system outside of a research setting. CONCLUSIONS: In this proof-of-concept research, young adults demonstrated that they used the UV Guard system; however, optimization was needed. Although some sun protection behaviors changed, sunburn was not prevented in all participants, especially during outdoor exercise. TRIAL REGISTRATION: ClinicalTrials.gov NCT03344796; http://clinicaltrials.gov/ct2/show/NCT03344796.


Assuntos
COVID-19 , Queimadura Solar , Adolescente , Adulto , Comportamentos Relacionados com a Saúde , Humanos , Pandemias , Estudos Prospectivos , SARS-CoV-2 , Queimadura Solar/tratamento farmacológico , Queimadura Solar/epidemiologia , Queimadura Solar/prevenção & controle , Protetores Solares/uso terapêutico , Raios Ultravioleta/efeitos adversos , Estados Unidos , Adulto Jovem
18.
Sci Adv ; 7(20)2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33980495

RESUMO

Soft, skin-integrated electronic sensors can provide continuous measurements of diverse physiological parameters, with broad relevance to the future of human health care. Motion artifacts can, however, corrupt the recorded signals, particularly those associated with mechanical signatures of cardiopulmonary processes. Design strategies introduced here address this limitation through differential operation of a matched, time-synchronized pair of high-bandwidth accelerometers located on parts of the anatomy that exhibit strong spatial gradients in motion characteristics. When mounted at a location that spans the suprasternal notch and the sternal manubrium, these dual-sensing devices allow measurements of heart rate and sounds, respiratory activities, body temperature, body orientation, and activity level, along with swallowing, coughing, talking, and related processes, without sensitivity to ambient conditions during routine daily activities, vigorous exercises, intense manual labor, and even swimming. Deployments on patients with COVID-19 allow clinical-grade ambulatory monitoring of the key symptoms of the disease even during rehabilitation protocols.


Assuntos
Acelerometria/instrumentação , Acelerometria/métodos , Eletrocardiografia Ambulatorial/instrumentação , Eletrocardiografia Ambulatorial/métodos , Dispositivos Eletrônicos Vestíveis , Temperatura Corporal , COVID-19 , Exercício Físico/fisiologia , Frequência Cardíaca , Humanos , Monitorização Fisiológica/instrumentação , Monitorização Fisiológica/métodos , SARS-CoV-2
19.
Nat Neurosci ; 24(7): 1035-1045, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33972800

RESUMO

Advanced technologies for controlled delivery of light to targeted locations in biological tissues are essential to neuroscience research that applies optogenetics in animal models. Fully implantable, miniaturized devices with wireless control and power-harvesting strategies offer an appealing set of attributes in this context, particularly for studies that are incompatible with conventional fiber-optic approaches or battery-powered head stages. Limited programmable control and narrow options in illumination profiles constrain the use of existing devices. The results reported here overcome these drawbacks via two platforms, both with real-time user programmability over multiple independent light sources, in head-mounted and back-mounted designs. Engineering studies of the optoelectronic and thermal properties of these systems define their capabilities and key design considerations. Neuroscience applications demonstrate that induction of interbrain neuronal synchrony in the medial prefrontal cortex shapes social interaction within groups of mice, highlighting the power of real-time subject-specific programmability of the wireless optogenetic platforms introduced here.


Assuntos
Optogenética/instrumentação , Comportamento Social , Tecnologia sem Fio/instrumentação , Animais , Camundongos
20.
Nat Protoc ; 16(6): 3072-3088, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-34031611

RESUMO

The use of optogenetics to regulate neuronal activity has revolutionized the study of the neural circuitry underlying a number of complex behaviors in rodents. Advances have been particularly evident in the study of brain circuitry and related behaviors, while advances in the study of spinal circuitry have been less striking because of technical hurdles. We have developed and characterized a wireless and fully implantable optoelectronic device that enables optical manipulation of spinal cord circuitry in mice via a microscale light-emitting diode (µLED) placed in the epidural space (NeuroLux spinal optogenetic device). This protocol describes how to surgically implant the device into the epidural space and then analyze light-induced behavior upon µLED activation. We detail optimized optical parameters for in vivo stimulation and demonstrate typical behavioral effects of optogenetic activation of nociceptive spinal afferents using this device. This fully wireless spinal µLED system provides considerable versatility for behavioral assays compared with optogenetic approaches that require tethering of animals, and superior temporal and spatial resolution when compared with other methods used for circuit manipulation such as chemogenetics. The detailed surgical approach and improved functionality of these spinal optoelectronic devices substantially expand the utility of this approach for the study of spinal circuitry and behaviors related to mechanical and thermal sensation, pruriception and nociception. The surgical implantation procedure takes ~1 h. The time required for the study of behaviors that are modulated by the light-activated circuit is variable and will depend upon the nature of the study.


Assuntos
Implantes Experimentais , Optogenética , Procedimentos Ortopédicos , Animais , Espaço Epidural/cirurgia , Feminino , Masculino , Camundongos , Técnicas de Patch-Clamp , Medula Espinal/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...