1.
Ter Arkh ; 93(1): 59-65, 2021 Jan 10.
Artigo em Russo | MEDLINE | ID: mdl-33720627

RESUMO

AIM: Coronary stenting is the evidence-based treatment approach of stable angina. The objective was to determine the incidence of restenosis or atherosclerosis progression which led to the need for coronary angiography according to a single center registry data. MATERIALS AND METHODS: The procedure and clinical data of 3732 (2897 males) consecutive stable coronary artery disease patients undergoing coronary stenting, over five years between March 2010 and September 2014, were subject of this study. Over the next 4 years, 1487 (1173 males) patients were re-evaluated due to angina reoccurrence. 699 patients demonstrated the indications for coronary angiography. RESULTS: The restenosis of the previously stented segment was detected in 84 (12%) cases, the progression of coronary atherosclerosis in 306 (44%), the combination of restenosis and atherosclerosis progression in 63 (9%), and the absence of these complications in 245 (35%) cases. The progression of coronary atherosclerosis was the leading indication for the repeat angiography and revascularization (44 and 58%, respectively); p0.05. The basal level of hsCRP2 mg/l had a prognostic significance for the development of combined event (the restenosis and atherosclerosis progression): AUC 0.65 (0.500.75), OR 3.0 (1.17.9), p0.05. CONCLUSION: The progression of coronary atherosclerosis was the leading indication for the repeat angiography and repeat revascularization during 2 years after coronary stenting. The hsCRP level 2 mg/l at baseline had a prognostic significance for the development of restenosis in previously stented segment and coronary atherosclerosis progression.


Assuntos
Angina Estável , Reestenose Coronária , Estenose Coronária , Angina Estável/diagnóstico por imagem , Angina Estável/epidemiologia , Constrição Patológica , Angiografia Coronária , Reestenose Coronária/diagnóstico por imagem , Reestenose Coronária/epidemiologia , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/cirurgia , Humanos , Masculino , Stents/efeitos adversos , Resultado do Tratamento
2.
Kardiologiia ; 60(2): 10-16, 2020 Mar 04.
Artigo em Russo | MEDLINE | ID: mdl-32345193

RESUMO

OBJECTIVE: Assess time and possible predictors of restenosis after the implantation of first- and second-generation coronary stents and bare metal stents (BMSs) in patients with stable coronary artery disease after elective coronary stenting. MATERIALS AND METHODS: From 2010 to 2014, 3,732 (2,897 males, 60 [53; 68] years old) patients with stable exertional angina of functional class I-III underwent coronary stenting. From 2014 to 2017, 1,487 (1,173 males and 314 females) patients returned. Repeat coronary angiography was performed in 699 patients. RESULTS: A total of 644 first-generation stents, 5,321 second-generation stents, and 473 BMSs were implanted. During the control coronary angiography, contrasting was repeated for 193 first-generation stents, 899 second-generation stents, and 77 BMSs. Restenosis (stenosis of 50 % or more in the previously stented segment) was detected in 28 (14 % of angiographic control) first-generation drug-eluting stents, 94 (10 %) second-generation drug-eluting stents, and 21 (27 %) BMSs. Patients with BMS restenosis returned significantly earlier than patients with restenosis of the first- and second-generation drug-eluting stents (11 [6, 27] months vs. 32 [11; 48]) months and 24 [12; 42] months, respectively; p<0.05). The initial and repeat levels of high-sensitivity C-reactive protein (hs-CRP) were higher in patients with restenosis (2.2 [1.2, 5.0] mg / L vs. 2.1 [1.0, 4.6] mg / L, respectively; p> 0.05) than in patients without restenosis (2.0 [0.9, 4.2] mg / L vs. 1.9 [0.7, 3.5] mg / L respectively, p>0.05). Blood levels of hs-CRP ≥2 mg / L according to receiver operating characteristic curve (ROC) analysis at return visit were used as a predictor to identify restenosis of stents with a diameter <3 mm and a length >25 mm - area under the curve (AUC) 0.67 (95 % confidence interval (CI) 0.51-0.84), p <0.05, odds ratio 3.7 (95 % CI 1.1-12.1), p<0.05. Stent type had a significant effect on the time to restenosis in the survival analysis (p<0.0005). CONCLUSION: The time from coronary stenting to the return visit of patients presenting with restenosis after the implantation of first- and second-generation drug-eluting stents is consistent; median time of the return visit of patients with restenosis of the first-generation stents was 2-3 years after coronary stenting. Blood levels of hs-CRP ≥2 mg / L at the return visit is a predictor of restenosis of stents with a diameter <3 mm and a length >25 mm.


Assuntos
Reestenose Coronária , Stents Farmacológicos , Idoso , Angiografia Coronária , Reestenose Coronária/epidemiologia , Feminino , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Stents , Resultado do Tratamento
3.
Kardiologiia ; 59(8S): 4-14, 2019 Sep 16.
Artigo em Russo | MEDLINE | ID: mdl-31526357

RESUMO

The main clinical manifestation of heart failure with preserved ejection fraction is poor exercise tolerance. In addi-tion to the dysfunction of the left heart chambers, which were presented in the first part of this review, many other disorders are involved in poor exercise tolerance in such patients: impairments of the right heart, vascular system and skeletal muscle. The second part of this review presents the mechanisms for the development of these disorders, as well as possible ways to correct them.


Assuntos
Tolerância ao Exercício , Insuficiência Cardíaca , Humanos , Músculo Esquelético , Consumo de Oxigênio
4.
Kardiologiia ; 59(6S): 4-16, 2019 Jul 24.
Artigo em Russo | MEDLINE | ID: mdl-31340744

RESUMO

During exercise an increase in oxygen delivery to working muscles is achieved through well­coordinated interaction of many organs and systems: the heart, lungs, blood vessels, skeletal muscles, and the autonomic nervous system. In heart failure with preserved left ventricular ejection fraction, all mechanisms involved in the normal exercise tolerance are impaired. In the first part of this review, the impairments of the left heart chambers are considered ­ left ventricular diastolic dysfunction, the weakening of the contractile and chronotropic reserves, left atrium dysfunction; the possible ways of their medical correction are also presented.


Assuntos
Teste de Esforço , Insuficiência Cardíaca , Tolerância ao Exercício , Humanos , Volume Sistólico , Função Ventricular Esquerda