Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 57
Filtrar
1.
J Hand Surg Glob Online ; 6(1): 43-45, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38313602

RESUMO

Purpose: Obtaining a hand surgery fellowship is becoming increasingly competitive, and research is an important factor when assessing applications. Given the competitive nature of the fellowship application process, applicants may feel the need to bolster their application by misrepresenting their research experience. One form of misrepresentation rarely discussed in prior studies is the listing of submitted works under a "Publications" heading in curricula vitae. This study examines the prevalence of misclassification of manuscripts by applicants to a hand surgery fellowship and identifies factors that might be associated with incorrect classification. Methods: A retrospective review of 122 applicants to the 2020-2021 cycle for hand surgery fellowship was performed. Names and identifiable information were redacted prior to review. Demographic data collected included sex, United States Medical Licensing Examination Step 1 score, medical school rank, residency specialty, total publications, presence of submitted manuscripts in the "Publications" section, total number of submitted manuscripts, and total published abstracts and poster presentations. Results: A total of 1,098 listed publications across the 122 applicants were reviewed with a median of five publications per applicant. Submitted manuscripts were listed as publications by 33 applicants (27%). No observable differences by age, United States Medical Licensing Examination Step 1 score, or total number of publications were seen. Misclassification rates were not associated with publication totals. Conclusions: More than one-quarter of applicants incorrectly listed submitted or unaccepted manuscripts as publications. It is our hope that making fellowship applicants aware of this issue will decrease the rates of misrepresentation in future application cycles. Clinical relevance: The competition for hand surgery fellowships has become more intense, and this may explain our finding that 27% of applicants misrepresent the status of research on hand surgery fellowship applications.

2.
J Hand Surg Glob Online ; 6(1): 91-97, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38313617

RESUMO

Management of elbow arthritis in younger and higher demand patients is challenging and may benefit from a distal humerus hemiarthroplasty that employs a noncemented method of implant fixation and stabilizes the elbow through ligament reconstruction. By not replacing both articulating surfaces, hardware longevity may be improved. We describe a novel system that may be indicated for the treatment of posttraumatic or primary osteoarthritis of the distal humerus. The step-by-step technique for surgical implantation of this uncemented distal humerus hemiarthroplasty is described and illustrated.

3.
J Shoulder Elbow Surg ; 33(1): 156-163, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37659704

RESUMO

BACKGROUND: The purpose of this study was to create a model to simulate treatment of unreconstructable distal humerus fractures with hemiarthroplasty. Stability was restored with a latest plate-system that simultaneously tensions medial and lateral collateral ligament grafts. MATERIALS AND METHODS: Static varus and valgus elbow stability was tested in 11 cadaver elbows with intact ligaments and capsule at 5 flexion angles (0°, 30°, 60°, 90°, 120°). The elbows were then destabilized via release of all ligaments and capsular attachments. The distal humerus articular cartilage was excised and replaced with an uncemented hemiarthroplasty. Ligament reconstruction was subsequently performed, and elbow stability was measured and compared to the native state. Dimensions of the hemiarthroplasty component were compared to native elbow dimensions to assess and quantify any existing relationship to elbow stability. RESULTS: A hemiarthroplasty was implanted in all specimens. A size mismatch occurred between the distal humerus trochlea and the olecranon fossa in all specimens and averaged 6.3 mm. Following ligament reconstruction, specimens reproduced the flexion angle-dependent stability of native elbows to both varus and valgus stress. On the medial side, elbow joint stability in mid-flexion was approximately 7% tighter after hemiarthroplasty. Laterally, the elbow was approximately 15% tighter after hemiarthroplasty and demonstrated peak stability in full flexion. The 3 assessed hemiarthroplasty components and bony dimensions did not exhibit any relationship between implant-bone mismatch and elbow stability after ligamentous reconstruction. CONCLUSION: Cadaveric elbow specimens underwent uncemented hemiarthroplasty with soft tissue stabilization with a novel technique for ligament reconstruction. Following hemiarthroplasty and ligament reconstruction, these specimens maintained secure fixation between ligament and bone. Static stability was maintained at varying degrees of elbow flexion regardless of variable mismatch between the hemiarthroplasty component and the native olecranon fossa.


Assuntos
Ligamentos Colaterais , Articulação do Cotovelo , Hemiartroplastia , Instabilidade Articular , Procedimentos de Cirurgia Plástica , Humanos , Cotovelo/cirurgia , Articulação do Cotovelo/cirurgia , Ligamentos Colaterais/cirurgia , Cadáver , Amplitude de Movimento Articular , Fenômenos Biomecânicos , Instabilidade Articular/cirurgia
4.
Instr Course Lect ; 73: 231-245, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38090901

RESUMO

Neuroarthropathy of the foot and ankle presents a series of challenges. The treating physician faces a perfect storm of pathomechanics, deformity, and medical comorbidities. Successful treatment requires a systematic approach in diagnosis, nonsurgical management, surgical management, and long-term maintenance of the affected extremity. Nonsurgical care of the Charcot foot remains the mainstay of treatment and is successful in most cases. Surgery has become more accepted for patients with severe deformity. The concept of a superconstruct has been introduced to describe modern surgical techniques and implants that have been developed since the early 2000s where stability and durability are maximized. A superconstruct is defined by four factors: (1) fusion is extended beyond the zone of injury to bridge the area of bony dissolution; (2) aggressive bone resection is performed to allow for adequate reduction of deformity without undue tension on the soft-tissue envelope; (3) stronger implants are used than for nonneuropathic fusion procedures, including some specifically developed for fixation of the Charcot foot; and (4) the devices are applied in a position that maximizes mechanical stability to allow the implants to become load sharing. It is important to review the current techniques and implants used in fusion of the neuropathic midfoot and discuss the expected outcomes and complications based on the authors' experience.


Assuntos
Artropatia Neurogênica , Pé Diabético , Procedimentos de Cirurgia Plástica , Humanos , Artrodese/métodos , Artropatia Neurogênica/cirurgia , Artropatia Neurogênica/complicações , Pé Diabético/cirurgia , Pé Diabético/complicações
5.
J Hand Surg Am ; 2023 Aug 07.
Artigo em Inglês | MEDLINE | ID: mdl-37552143

RESUMO

PURPOSE: The objective of this study was to determine the structural properties of the cadaver bone-screw interface for cementless intramedullary screw fixation in the context of total elbow arthroplasty. METHODS: The intramedullary canals of seven humerus and seven ulna specimens from fresh-frozen cadavers were drilled using custom drill bits until the inner cortex was reached and then hand tapped for the corresponding thread size. Titanium screws were advanced into the tapped holes until securely seated. The bones were potted and then mounted on a uniaxial material testing machine. A tensile load was applied, and end-of-test elongation, failure load, energy absorbed, and stiffness were determined. End-of-test load and elongation were defined as the elongation and load experienced by the structure at 3,000 N or failure. Each specimen was inspected for evidence of pullout, loosening, or visible fractures. RESULTS: The end-of-test load and elongation for the humerus specimens were 2721 ± 738 N and 3.0 ± 0.9 mm, respectively. The ulna specimens reached 92% of the humerus specimens' end-of-test load at 2,514 ± 678 N and 120% of their end-of-test elongation (3.6 ± 0.6 mm). The stiffness of the humerus specimens was 1,077 ± 336 N/mm, which was 1.3 times greater than the stiffness of the ulna specimens (790 ± 211 N/mm). Lastly, the energy absorbed by the humerus samples was 3.6 ± 1.6 J, which was 92% of the energy absorbed by the ulna samples at 3.9 ± 1.1 J. One humerus and three ulnas failed before the end-of-test load of 3,000 N. Two failures were caused by screw pullout and two by bone fracture. CONCLUSIONS: Our findings demonstrate that intramedullary screw fixation is successful in withstanding forces that are greater than required for osseointegration. CLINICAL RELEVANCE: Uncemented fixation may be beneficial in elbow arthroplasty.

6.
Hand (N Y) ; : 15589447231184894, 2023 Jul 17.
Artigo em Inglês | MEDLINE | ID: mdl-37458253

RESUMO

BACKGROUND: Intramedullary screw fixation of the proximal ulna can be used for fixation of the ulnar component in total elbow arthroplasty. Our purpose was to use computed tomography (CT) to characterize proximal ulna anatomy with respect to intramedullary screw fixation, and then to validate this templating process by inserting intramedullary screws into 3-dimensional (3D)-printed models. METHODS: Thirty elbow CT scans were reformatted in the axis of the proximal ulna. Screw placement was templated by fixing a length at 78 mm distal to the centerline of ulnohumeral rotation and measuring diameter, and then fixing the screw pitch diameter to 5.5 mm and measuring length. Three-dimensional models were printed for 5 patients, and intramedullary screws were advanced as distal as possible until endosteal fit was achieved. RESULTS: All patients had an anatomic limit for intramedullary screw fixation, due to dorsal angulation, varus angulation, or both. At 78 mm distal to the centerline of rotation, mean screw diameter was 5.4 mm (range, 3.2-8.0). When fixing screw diameter to 5.5 mm, the mean screw length was 79.9 mm (range, 64.2-107.9). All intramedullary screws were placed in the 3D models within 3 mm of the templated length, with correlation coefficient 0.992. CONCLUSION: This study characterized proximal ulna anatomy in the context of intramedullary screw fixation. Templating allows surgeons to predict intramedullary screw sizing, and a broad range of screw lengths and diameters is required when attempting intramedullary screw fixation for placement of the ulnar component in uncemented total elbow arthroplasty.

7.
J Hand Surg Glob Online ; 5(3): 318-324, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37323975

RESUMO

Purpose: The treatment of bidirectional ligament instability is proposed using a method that simultaneously tensions medial and lateral ligaments. Graft tension is maintained via plates that apply compression between the graft and bone. Methods: We tested static varus and valgus elbow stability in six cadaver elbows with intact ligaments and capsules at five positions, and then created gross instability by dividing all soft tissue attachments. A ligament reconstruction was subsequently performed with and without nonabsorbable ligament augmentation. Elbow stability was measured and compared with the native state. Results: The augmented and the nonaugmented ligament reconstructions provided stability to the lateral side with only 1.0 mm of increased deflection recorded for the augmented ligaments and 0.6 mm for the nonaugmented when compared with the native state. On the medial side, the deflection was greater after reconstruction compared with the native state with the augmented ligaments ranging between 1.0 and 1.8 mm and the nonaugmented ligament reconstruction ranging between 2.4 and 3.3 mm. Conclusions: This novel ligament reconstruction maintained secure fixation between ligament and bone and allowed for maintenance of static stability at different degrees of elbow flexion. Clinical Relevance: Restoring elbow stability using a method that minimizes ligament graft and which may not need to be removed could benefit management of bidirectionally unstable elbows, such as following interposition arthroplasty or substantial trauma.

8.
J Shoulder Elbow Surg ; 32(4): 738-743, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36584867

RESUMO

BACKGROUND: The role of the coronoid process in elbow instability has been established. When necessary, coronoid fixation can be challenging. Placing fixation perpendicular to the fracture requires achieving a trajectory as close as possible to the midline axis of the proximal ulna, either from anterior to posterior or vice versa. The aim of this study was to determine whether coronoid exposure-and the ability to place fixation from anterior to posterior-is improved via a lateral extensor-splitting approach with forearm supination, that is, the "spin move," with progressive stages of lateral elbow instability. METHODS: The lateral extensor-splitting approach was performed on 9 cadaveric upper extremities. A 0.157-mm (0.062-inch) wire was drilled perpendicularly into the lateral aspect of the humerus just proximal to the lateral epicondyle. A second wire was drilled into the tip of the coronoid, aiming for a drill trajectory as close as possible to the midline axis. The angle between the 2 wires was measured as the initial angle. Three stages of progressive lateral elbow instability were produced by sequential release of the lateral ulnar collateral ligament (LUCL), common extensor origin (CEO), and posterior capsule. At each stage, the spin move was performed and the angle between the 2 wires was measured. The difference between this angle and the initial angle was calculated, with the average value reported as the Δ angle for each stage. The average difference between each stage and the next stage was reported. RESULTS: The spin move resulted in Δ angles of 10.3° with the LUCL released, 20° with the CEO released, and 29.1° with the posterior capsule released. Progressing from LUCL release to CEO release to posterior capsule release, the Δ angle between the K-wires increased an average of 9.6° from the LUCL stage to the CEO stage and 9.1° from the CEO stage to the posterior capsule stage. CONCLUSION: The spin move is a simple maneuver that can improve exposure of the coronoid process regardless of the degree of elbow instability. This may facilitate a more perpendicular screw, bone tunnel, or suture anchor trajectory via the lateral approach, reducing the need for posterior-to-anterior fixation. The improved exposure is inferred from the differences in the K-wire angles with and without the spin move. This study has also quantified the change in coronoid exposure using the angles of the wires with progressive release of the LUCL, CEO, and posterior capsule. If necessary, releasing the CEO or posterior capsule with eventual repair may allow improved coronoid fixation from the lateral approach.


Assuntos
Lesões no Cotovelo , Articulação do Cotovelo , Fraturas Ósseas , Luxações Articulares , Instabilidade Articular , Fraturas da Ulna , Humanos , Articulação do Cotovelo/cirurgia , Instabilidade Articular/cirurgia , Cotovelo/cirurgia , Luxações Articulares/cirurgia , Fixação Interna de Fraturas/métodos , Fraturas da Ulna/cirurgia
9.
Hand (N Y) ; : 15589447221120843, 2022 Sep 27.
Artigo em Inglês | MEDLINE | ID: mdl-36168734

RESUMO

BACKGROUND: Epinephrine use during hand surgery has been stigmatized due to a fear of digital necrosis. Clinical experience in the past 2 decades has shown epinephrine in local anesthetic to be safe. We sought to analyze the use of epinephrine among hand surgeons and identify variables associated with it. METHODS: A deidentified 21-question survey was distributed via email to the 914 and 415 members of the American Association for Hand Surgery and the Canadian Society for Surgery of the Hand, respectively. Questions included residency type, years of practice, practice setup/ownership, practice leadership, usage of epinephrine, availability of reversal agents, and reasons for or against usage. RESULTS: Of 188 responders, 170 (90%) used epinephrine in local anesthetic for hand surgery procedures. By nationality, 100% (43) of Canadian surgeons and 89% (108) of US surgeons use epinephrine (P = .01). Among surgeons with practice ownership, 88% (102) used epinephrine compared with 93% (85) of those surgeons that we employed (P = .28). Comparing surgeons with teaching responsibilities versus those without training responsibilities showed that surgeons who did not teach used epinephrine at a higher rate (87% vs 98%, P = .04). In addition, plastic surgery-trained surgeons (111) used epinephrine in 97.2% of cases while orthopedic surgery-trained surgeons (57) used epinephrine in 80.2% of cases (P = .0003). No difference was found when examining the use of epinephrine and surgeon age (P = .28). CONCLUSIONS: Most respondents believe that epinephrine is safe. Training background, location, and practice setup are significant factors in the use of epinephrine, whereas practice ownership and physician age are not major factors.

10.
Oper Tech Orthop ; 32(4): 100998, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36164488

RESUMO

Covid-19 has led to an increase in the use of PPE, gowns, masks, sanitizers, air circulators, and much more, all contributing to an increase in medical waste. Waste generation is one issue. Emissions are another. The two are linked because waste and emissions are both indicators of consumption. However, waste is not the biggest driver of environmental emissions for healthcare. It is the production of medical equipment, particularly disposables that have a bigger impact. Energy use during care, including heating and cooling our facilities, is another. Environmental emissions like greenhouse gases may not correlate with waste generation, especially if the waste is plastic. Carbon is stored in plastic. Unless you're burning plastic, you're not emitting carbon. Healthcare has a waste issue and healthcare has an emissions issue. They are not necessarily the same thing, however, the strategies to mitigate each overlap. Life cycle assessment quantifies emissions from the creation to disposal of medical supplies. This allows the medical community to make informed choices with respect to the methods and materials that are used in providing care. As other specialties take the lead in reducing their environmental footprint, so too, must orthopedic surgery.

11.
Hand Clin ; 36(4): 495-510, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-33040962

RESUMO

Elbow dislocations represent common injuries. A quarter of these injuries involve at least 1 fracture. The sequel of elbow fracture-dislocations can be fraught with complications, including recurrent instability, posttraumatic arthritis, elbow contracture, and poor functional results. The 3 main patterns of injury are valgus posterolateral rotatory instability, varus posteromedial rotatory instability, and transolecranon fracture-dislocation. This article discusses each pattern individually, including the anatomy, the typical injury pattern, and treatment strategies. It also discusses common complications that can occur.


Assuntos
Lesões no Cotovelo , Articulação do Cotovelo/cirurgia , Fratura-Luxação/terapia , Ligamento Colateral Ulnar/lesões , Ligamento Colateral Ulnar/cirurgia , Articulação do Cotovelo/diagnóstico por imagem , Serviço Hospitalar de Emergência , Fratura-Luxação/diagnóstico , Fixação Interna de Fraturas/métodos , Humanos , Instabilidade Articular/diagnóstico , Instabilidade Articular/terapia , Olécrano/lesões , Olécrano/cirurgia , Cuidados Pós-Operatórios , Complicações Pós-Operatórias , Fraturas do Rádio/diagnóstico , Fraturas do Rádio/terapia , Fraturas da Ulna/diagnóstico , Fraturas da Ulna/terapia
12.
Instr Course Lect ; 69: 291-316, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32017734

RESUMO

In this chapter, the authors describe hand conditions that can be "bad actors" and provide specific clues to identify these problems, and strategies to assess and successfully treat them. We will review pediatric and adult hand fractures, fractures of the distal radius, and trigger digits.


Assuntos
Fraturas do Rádio , Traumatismos do Punho , Articulação do Punho , Adulto , Criança , Fixação Interna de Fraturas , Humanos , Punho
13.
Orthop Clin North Am ; 50(3): 357-366, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31084838

RESUMO

Subungual melanoma is a rare form of melanoma that presents a unique set of challenges largely based on the complex anatomy of the nail unit. Subungual melanoma often first appears with longitudinal melanonychia. Thus, practitioners must have a high clinical suspicion in any patient with longitudinal melanonychia and a low threshold for a biopsy. The "ABCDEF" guide can be a useful tool to aid in screening any lesion of the nail bed. The authors recommend that biopsies of the nail unit be performed by a surgeon with an in-depth understanding of the pathoanatomy of subungual melanoma.


Assuntos
Melanoma , Doenças da Unha , Neoplasias Cutâneas , Biópsia , Dermoscopia , Detecção Precoce de Câncer , Humanos , Sarda Melanótica de Hutchinson/patologia , Incidência , Linfonodos/patologia , Margens de Excisão , Melanoma/diagnóstico , Melanoma/epidemiologia , Melanoma/patologia , Melanoma/cirurgia , Doenças da Unha/diagnóstico , Doenças da Unha/epidemiologia , Doenças da Unha/patologia , Doenças da Unha/cirurgia , Transtornos da Pigmentação/patologia , Cuidados Pós-Operatórios , Prevalência , Neoplasias Cutâneas/diagnóstico , Neoplasias Cutâneas/epidemiologia , Neoplasias Cutâneas/patologia , Neoplasias Cutâneas/cirurgia , Resultado do Tratamento
14.
BMC Musculoskelet Disord ; 20(1): 135, 2019 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-30927912

RESUMO

BACKGROUND: Dupuytren's disease (DD) is a progressive, debilitating condition of the hand that can eventually cause contractures of the affected fingers. Transforming growth factor- ß1 (TGF-ß1) has been reported to play a key role in DD pathology. Increased expression of TGF-ß1 has shown to be the main stimulator of myofibroblast activity and in DD contractures. Pirfenidone (PFD), a small active molecule possess the ability to inhibit TGF-ß1-mediated action in various fibrotic disorders. Our recent published findings show that PFD reduced TGF-ß1-mediated cellular functions implicated in DD through SMAD signaling pathways. In the present study, the effect of PFD on TGF-ß1-mediated non-SMAD signaling pathways were investigated in both carpal tunnel (CT) - and DD-derived fibroblasts. METHODS: Fibroblasts harvested from Dupuytren's disease (DD) and carpal tunnel (CT) tissues were cultured in the presence or absence of TGF-ß1 (10 ng/ml) and/or PFD (800 µg/ml). Cell lysates were analyzed using Western blots. Equal amounts of proteins were loaded to determine the phosphorylation levels of phosphatidylinositol-3 kinase (PI3K/AKT), extracellular regulated kinases (ERK1/2), p38 mitogen-activated protein kinase and Rho family related myosin light chain (MLC). RESULTS: We show that the TGF-ß1-induced phosphorylation of AKT was significantly decreased by the addition of PFD (800 µg/mL) in both CT- and DD-derived fibroblasts. Interestingly, there was no significant difference in the phosphorylation levels of both ERK and p38 on TGF-ß1- induced cells in both CT-and DD-derived fibroblasts. But, PFD significantly decreased the TGF- ß1-induced phosphorylation levels of ERK1/2 in both CT- and DD- cells. In contrast, PFD significantly decreased the basal and TGF- ß1-induced phosphorylation levels of p38 in DD-derived fibroblasts. TGF- ß1-induced phosphorylation levels of MLC was decreased by PFD in DD-derived fibroblasts. CONCLUSIONS: These in-vitro results indicate for the first time that PFD has the potential to inhibit TGF-ß1-induced non-SMAD signaling pathways in both CT- and DD-derived fibroblasts but pronounced statistically significant inhibition on all molecules was observed only in DD-derived fibroblasts. Our previous studies show that PFD can inhibit TGF-ß1- induced SMAD signaling pathway proteins, namely p- SMAD2/SMAD3. These broad and complementary actions suggest PFD as a promising candidate to inhibit the TGF-ß1- mediated molecular mechanisms leading to DD fibrosis.


Assuntos
Contratura de Dupuytren/tratamento farmacológico , Fibroblastos/efeitos dos fármacos , Piridonas/farmacologia , Transdução de Sinais/efeitos dos fármacos , Fator de Crescimento Transformador beta1/metabolismo , Síndrome do Túnel Carpal/patologia , Células Cultivadas , Contratura de Dupuytren/patologia , Contratura de Dupuytren/cirurgia , Fáscia/citologia , Fibroblastos/metabolismo , Humanos , Proteínas Quinases Ativadas por Mitógeno/metabolismo , Fosforilação/efeitos dos fármacos , Cultura Primária de Células , Proteínas Proto-Oncogênicas c-akt/metabolismo , Piridonas/uso terapêutico , Fator de Crescimento Transformador beta1/antagonistas & inibidores
15.
J Shoulder Elbow Surg ; 28(5): e150-e155, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-30713062

RESUMO

HYPOTHESIS: This study's purpose was to provide a reproducible way for surgeons to intraoperatively assess the elbow's lateral ulnar collateral ligament origin and determine whether there is posterolateral rotatory instability (PLRI) despite an intact common extensor origin (CEO). We hypothesized that we could re-create clinically relevant disruption of lateral supporting structures despite an intact CEO and illustrate progressive elbow PLRI. METHODS: The relationship of the lateral capsule to the capitellum articular surface was noted in 8 cadaveric upper extremities. The lateral capsule and extensor origin were sequentially sectioned at 4 stages: intact, release to the lateral epicondyle, release of the posterior capsular insertion, and release of the CEO. Posterior and lateral translation of the radial head (RH) relative to the capitellum was measured with the forearm in extension and supination. RESULTS: The average specimen age was 78.9 years. The lateral capsule originated within 1 to 2 mm of the capitellum articular surface. Lateral capsular sectioning to the 6-o'clock position of the lateral epicondyle created an unstable elbow with posterior and lateral RH translation. Sequential sectioning of the posterior capsular insertion created significant additional RH translation posteriorly (P < .05). With release of the capsule and the extensor origin, the elbow was grossly unstable. CONCLUSIONS: The elbow's lateral capsuloligamentous complex plays an important role in preventing PLRI. Larger degrees of elbow laxity are associated with further peel back of the capsuloligamentous complex despite an intact CEO. The surgeon must retract the extensor origin intraoperatively to assess for lateral ulnar collateral ligament and/or lateral capsule disruption to prevent a missed case of PLRI.


Assuntos
Ligamento Colateral Ulnar/anatomia & histologia , Ligamento Colateral Ulnar/cirurgia , Articulação do Cotovelo/cirurgia , Instabilidade Articular/diagnóstico , Idoso , Idoso de 80 Anos ou mais , Cadáver , Ligamento Colateral Ulnar/lesões , Feminino , Humanos , Período Intraoperatório , Instabilidade Articular/cirurgia , Masculino , Lesões no Cotovelo
16.
J Hand Ther ; 32(1): 35-40, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-29150383

RESUMO

STUDY DESIGN: Clinical measurement. INTRODUCTION: Common provocative maneuvers to differentiate thumb carpometacarpal (CMC) osteoarthritis from other sources of pain are the grind, metacarpal (MC) flexion, and MC extension tests. A maneuver known as the pressure-shear test is described here. PURPOSE OF THE STUDY: To compare the diagnostic value of the grind, metacarpal flexion, metacarpal extension, and pressure-shear tests for CMC osteoarthritis of the thumb. METHODS: The diagnostic accuracy of each test was compared in 127 thumbs from 104 patients. Sensitivity, specificity, and predictive values of each test were calculated. In a secondary analysis, polychoric correlation coefficients were used to assess the correlation of each test with severity defined by Eaton-Littler stage. RESULTS: The overall diagnostic accuracy of the thumb MC grind, pressure-shear, flexion, and extension tests were 70%, 98%, 47%, and 55%, respectively. The sensitivities were 64%, 99%, 36%, and 46%, respectively, and specificities were 100%, 95%, 100%, and 100%, respectively. For the diagnosis of Thumb CMC arthritis, the MC pressure-shear test was superior overall in terms of overall diagnostic accuracy and sensitivity, while having comparable specificity to the other maneuvers. CONCLUSION: The pressure-shear test was found to be superior to the commonly used grind maneuver and the provocative maneuvers of MC flexion and extension tests to confirm diagnosis of CMC osteoarthritis.


Assuntos
Articulações Carpometacarpais/fisiopatologia , Ossos Metacarpais/fisiopatologia , Osteoartrite/diagnóstico , Exame Físico/métodos , Polegar/fisiopatologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Osteoartrite/classificação , Osteoartrite/fisiopatologia , Valor Preditivo dos Testes , Sensibilidade e Especificidade , Adulto Jovem
17.
J Orthop Trauma ; 32(3): e86-e91, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-29065040

RESUMO

OBJECTIVE: To biomechanically assess the angular stability provided by 3 techniques for reconstruction of the lateral ulnar collateral ligament. METHODS: Eight cadaveric elbows were tested with the lateral collateral ligament complex intact, disrupted from the origin at the lateral epicondyle, and reconstructed with 3 different techniques using ulnar bone tunnels: a suture "lasso" or palmaris longus tendon "lasso" both docked with a metal button at the origin, and a doubled-over palmaris longus tendon docked with metal buttons at both the origin and ulnar insertion. Elbows were tested with a physiologic elbow simulator, and varus angular position was quantified with an optical tracking system. Statistical analysis was performed using a repeated measures analysis of variance test to determine whether significance existed, and a Tukey post hoc analysis to compare statistical difference between native, disrupted, and repair states. RESULTS: There was a statistically significant difference between all repairs and the disrupted state (P < 0.05). The varus angulation after the repairs showed that the suture reconstruction was closest to the native case. The tendon reconstructions were similar to each other but less similar to the native elbow. Quantitatively, the suture reconstruction was within an average of 0.86 degrees of the native elbow throughout range of motion. CONCLUSIONS: A suture reconstruction was most similar to a native elbow, but both tendon reconstructions significantly improved angular stability under varus gravitational loads.


Assuntos
Ligamento Colateral Ulnar/fisiopatologia , Ligamento Colateral Ulnar/cirurgia , Articulação do Cotovelo/fisiopatologia , Articulação do Cotovelo/cirurgia , Instabilidade Articular/fisiopatologia , Reconstrução do Ligamento Colateral Ulnar/métodos , Idoso , Fenômenos Biomecânicos , Cadáver , Ligamento Colateral Ulnar/lesões , Feminino , Humanos , Instabilidade Articular/cirurgia , Masculino , Tendões/transplante , Lesões no Cotovelo
18.
BMC Musculoskelet Disord ; 17(1): 469, 2016 11 11.
Artigo em Inglês | MEDLINE | ID: mdl-27835939

RESUMO

BACKGROUND: Dupuytren's disease (DD) is a complex fibro-proliferative disorder of the hand that is often progressive and eventually can cause contractures of the affected fingers. Transforming growth factor beta (TGF-ß1) has been implicated as a key stimulator of myofibroblast activity and fascial contraction in DD. Pirfenidone (PFD) is an active small molecule shown to inhibit TGF-ß1-mediated action in other fibrotic disorders. This study investigates the efficacy of PFD in vitro in inhibiting TGF-ß1-mediated cellular functions leading to Dupuytren's fibrosis. METHODS: Fibroblasts harvested from (DD) and carpal tunnel (CT)- tissues were treated with or without TGF-ß1 and/or PFD and were subjected to cell migration, cell proliferation and cell contraction assays. ELISA; western blots and real time RT-PCR assays were performed to determine the levels of fibronectin; p-Smad2/Smad3; alpha-smooth muscle actin (α-SMA), α2 chain of type I collagen and α1 chain of type III collagen respectively. RESULTS: Our results show that PFD effectively inhibits TGF-ß1-induced cell migration, proliferation and cell contractile properties of both CT- and DD-derived fibroblasts. TGF-ß1-induced α-SMA mRNA and protein levels were inhibited at the higher concentration of PFD (800 µg/ml). Interestingly, TGF-ß1 induction of type I and type III collagens and fibronectin was inhibited by PFD in both CT- and DD- derived fibroblasts, but the effect was more prominent in DD cells. PFD down-regulated TGF-ß1-induced phosphorylation of Smad2/Smad3, a key factor in the TGF-ß1 signaling pathway. CONCLUSION: Taken together these results suggest the PFD can potentially prevent TGF-ß1-induced fibroblast to myofibroblast transformation and inhibit ECM production mainly Type I- and Type III- collagen and fibronectin in DD-derived fibroblasts. Further in-vivo studies with PFD may lead to a novel therapeutic application in preventing the progression or recurrence of Dupuytren's disease.


Assuntos
Anti-Inflamatórios não Esteroides/uso terapêutico , Contratura de Dupuytren/tratamento farmacológico , Fibroblastos/efeitos dos fármacos , Piridonas/uso terapêutico , Anti-Inflamatórios não Esteroides/farmacologia , Movimento Celular/efeitos dos fármacos , Proliferação de Células/efeitos dos fármacos , Colágeno Tipo I/metabolismo , Colágeno Tipo III/metabolismo , Avaliação Pré-Clínica de Medicamentos , Fibroblastos/metabolismo , Fibronectinas/metabolismo , Humanos , Fosforilação/efeitos dos fármacos , Cultura Primária de Células , Piridonas/farmacologia , Proteína Smad2/metabolismo , Proteína Smad3/metabolismo , Fator de Crescimento Transformador beta1/metabolismo
19.
J Bone Joint Surg Am ; 98(21): 1814-1820, 2016 Nov 02.
Artigo em Inglês | MEDLINE | ID: mdl-27807114

RESUMO

BACKGROUND: Extra-articular ulnar shortening osteotomy is a common procedure for the surgical treatment of ulnar impaction syndrome. Several techniques for this osteotomy have been developed to avoid the morbidity associated with a standard transverse osteotomy. However, these techniques require special instrumentation and are expensive. The purpose of this study was to evaluate the outcome of step-cut ulnar shortening osteotomy without special jigs for ulnar impaction syndrome. METHODS: A retrospective study of 164 consecutive patients who underwent step-cut ulnar shortening osteotomy between 2000 and 2010 was performed. The long arm of the step-cut osteotomy was oriented in the coronal plane parallel to the long axis of the ulna. The short arms of the osteotomy were perpendicular to the long axis in the axial plane. Fixation was performed with a palmar 3.5-mm standard neutralization plate and a lag screw. The goal of the osteotomy was to reduce ulnar variance, which was assessed in all patients with pronated grip-view radiographs preoperatively and postoperatively. Preoperative ulnar variance ranged from +1 to +6 mm. RESULTS: All patients were followed for at least 24 months. Union of the osteotomy site was achieved at a mean of 8.2 weeks. The union rate was 98.8%. There were 2 cases of nonunion, which required additional surgery. The mean postoperative ulnar variance was +0.2 mm (range, -1 to +1.5 mm) after a mean overall ulnar shortening of 2.5 mm. All patients returned to their previous work, in a mean of 4 months. The plate was removed from 12 patients because of plate-related symptoms. No other complications were encountered. CONCLUSIONS: The step-cut ulnar shortening osteotomy provides ample bone-to-bone contact and simplifies control of rotation. Stable internal fixation with standard techniques allowed an early return to functional activities. Palmar placement of the plate diminishes the need for plate removal. This is a simple and less expensive technique for ulnar shortening that does not require the use of special instrumentation in patients with ulnar impaction syndrome. LEVEL OF EVIDENCE: Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.


Assuntos
Doenças Ósseas/cirurgia , Osteotomia/métodos , Ulna/cirurgia , Adolescente , Adulto , Artroscopia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento , Articulação do Punho/cirurgia , Adulto Jovem
20.
Hand (N Y) ; 11(4): 433-437, 2016 12.
Artigo em Inglês | MEDLINE | ID: mdl-28149210

RESUMO

Background: Closed reduction with percutaneous Kirschner wires (K-wires) is the most minimally invasive surgical option for stabilizing phalanx fractures. This study examines the effect of K-wire placement on proximal interphalangeal (PIP) joint motion. Methods: PIP joint flexion was measured in the digits of 4 fresh-frozen cadaver hands after placing a suture loop through the flexor tendons and placing tension on the flexors via a mechanical scale. The load necessary to flex the PIP joint to 90° or to maximum flexion was recorded. The load was removed and K-wires were inserted in 3 locations about the metacarpophalangeal joint (MPJ): through the extensor tendon and across the MPJ, adjacent to the extensor tendon insertion site and across the MPJ, and through the sagittal band and into the base of the proximal phalanx (P1). The load on the tendons was reapplied, and angles of PIP joint flexion were recorded for each of the 3 conditions. Results: The mean angle of PIP joint flexion prior to K-wire insertion was 87°, and the mean load applied was 241 g. The angles of flexion were 53° when the K-wire was placed through the extensor tendon, 70° when the K-wire was placed adjacent to the tendon, and 75° when the K-wire was placed into the base of P1 by going through the sagittal band, midway between the volar plate and the extensor tendon. Conclusions: K-wires placed remote from the extensor tendon create less of an immediate tether to PIP joint flexion than those placed through or adjacent to the extensor tendon.


Assuntos
Fios Ortopédicos , Falanges dos Dedos da Mão/lesões , Fixação Intramedular de Fraturas/métodos , Fraturas Ósseas/cirurgia , Amplitude de Movimento Articular , Suturas , Tendões/fisiopatologia , Cadáver , Feminino , Falanges dos Dedos da Mão/fisiopatologia , Falanges dos Dedos da Mão/cirurgia , Fixação Intramedular de Fraturas/instrumentação , Humanos , Masculino , Articulação Metacarpofalângica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...