Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Int J Mol Sci ; 25(3)2024 Jan 26.
Artigo em Inglês | MEDLINE | ID: mdl-38338792

RESUMO

Tumorigenic assays are used during a clinical translation to detect the transformation potential of cell-based therapies. One of these in vivo assays is based on the separate injection of each cell type to be used in the clinical trial. However, the injection method requires many animals and several months to obtain useful results. In previous studies, we showed the potential of tissue-engineered skin substitutes (TESs) as a model for normal skin in which cancer cells can be included in vitro. Herein, we showed a new method to study tumorigenicity, using cancer spheroids that were embedded in TESs (cTES) and grafted onto athymic mice, and compared it with the commonly used cell injection assay. Tumors developed in both models, cancer cell injection and cTES grafting, but metastases were not detected at the time of sacrifice. Interestingly, the rate of tumor development was faster in cTESs than with the injection method. In conclusion, grafting TESs is a sensitive method to detect tumor cell growth with and could be developed as an alternative test for tumorigenicity.


Assuntos
Neoplasias , Pele Artificial , Animais , Camundongos , Queratinócitos/metabolismo , Engenharia Tecidual/métodos , Neoplasias/metabolismo
2.
Burns Trauma ; 11: tkad043, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37908563

RESUMO

Background: The aim of this in vitro study was to compare side-by-side two models of human bilayered tissue-engineered skin substitutes (hbTESSs) designed for the treatment of severely burned patients. These are the scaffold-free self-assembled skin substitute (SASS) and the human plasma-based skin substitute (HPSS). Methods: Fibroblasts and keratinocytes from three humans were extracted from skin biopsies (N = 3) and cells from the same donor were used to produce both hbTESS models. For SASS manufacture, keratinocytes were seeded over three self-assembled dermal sheets comprising fibroblasts and the extracellular matrix they produced (n = 12), while for HPSS production, keratinocytes were cultured over hydrogels composed of fibroblasts embedded in either plasma as unique biomaterial (Fibrin), plasma combined with hyaluronic acid (Fibrin-HA) or plasma combined with collagen (Fibrin-Col) (n/biomaterial = 9). The production time was 46-55 days for SASSs and 32-39 days for HPSSs. Substitutes were characterized by histology, mechanical testing, PrestoBlue™-assay, immunofluorescence (Ki67, Keratin (K) 10, K15, K19, Loricrin, type IV collagen) and Western blot (type I and IV collagens). Results: The SASSs were more resistant to tensile forces (p-value < 0.01) but less elastic (p-value < 0.001) compared to HPSSs. A higher number of proliferative Ki67+ cells were found in SASSs although their metabolic activity was lower. After epidermal differentiation, no significant difference was observed in the expression of K10, K15, K19 and Loricrin. Overall, the production of type I and type IV collagens and the adhesive strength of the dermal-epidermal junction was higher in SASSs. Conclusions: This study demonstrates, for the first time, that both hbTESS models present similar in vitro biological characteristics. However, mechanical properties differ and future in vivo experiments will aim to compare their wound healing potential.

3.
Int J Mol Sci ; 24(19)2023 Sep 28.
Artigo em Inglês | MEDLINE | ID: mdl-37834159

RESUMO

For the development of advanced therapies, the use of primary cells instead of cell lines is preferred. The manufacture of human tissue-engineered skin substitutes requires efficient isolation and culture protocols allowing a massive expansion of the cells in culture from an initial specimen of a minimal size. This study compared two skin cell isolation protocols, routinely applied in two clinical laboratories. Epithelial (keratinocytes) and dermal (fibroblasts) cells were isolated and cultured from three human skin biopsies (N = 3). The two-step digestion protocol (LOEX-Protocol) firstly used thermolysin to enzymatically disrupt the dermal-epidermal junction while, for the one-step digestion protocol (UPCIT-Protocol), mechanical detachment with scissors was applied. Then, the epidermal and dermal layers were digested, respectively, to achieve cell isolation. The cell size, viability, yield and growth were analyzed over five passages (P). The colony-forming efficiency (CFE) and Keratin 19 (K19) expression of epithelial cells were also assessed after P0 and P1. Regarding the dermal cells, no significant differences were observed in the tested parameters of isolation and culture. However, for the epithelial cells, viability was higher (93% vs. 85%) and the number of cells extracted per cm2 of skin was 3.4 times higher using the LOEX-Protocol compared to the UPCIT-Protocol. No significant difference was observed for any parameter once the keratinocytes were cultured from P1 to P4. The CFE and K19 expression decreased from P0 to P1 in both protocols, probably due to the culture process. This study shows that both protocols enable the efficient isolation of skin dermal and epithelial cells and subsequent culture to produce grafts destined for the treatment of patients.


Assuntos
Pele Artificial , Engenharia Tecidual , Humanos , Engenharia Tecidual/métodos , Pele , Queratinócitos , Separação Celular/métodos , Fibroblastos , Células Cultivadas
4.
Int J Mol Sci ; 24(16)2023 Aug 08.
Artigo em Inglês | MEDLINE | ID: mdl-37628718

RESUMO

Tissue-engineered skin substitutes (TESs) are used as a treatment for severe burn injuries. Their production requires culturing both keratinocytes and fibroblasts. The methods to grow these cells have evolved over the years, but bovine serum is still commonly used in the culture medium. Because of the drawbacks associated with the use of serum, it would be advantageous to use serum-free media for the production of TESs. In a previous study, we developed a serum-free medium (Surge SFM) for the culture of keratinocytes. Herein, we tested the use of this medium, together with a commercially available serum-free medium for fibroblasts (Prime XV), to produce serum-free TESs. Our results show that serum-free TESs are macroscopically and histologically similar to skin substitutes produced with conventional serum-containing media. TESs produced with either culture media expressed keratin 14, Ki-67, transglutaminase 1, filaggrin, type I and IV collagen, and fibronectin comparably. Mechanical properties, such as contraction and tensile strength, were comparable between TESs cultured with and without serum. Serum-free TESs were also successfully grafted onto athymic mice for a six-month period. In conclusion, Surge SFM and Prime XV serum-free media could be used to produce high quality clinical-grade skin substitutes.


Assuntos
Pele Artificial , Animais , Camundongos , Meios de Cultura Livres de Soro , Engenharia Tecidual , Fibroblastos , Queratinócitos , Camundongos Nus
5.
Int J Mol Sci ; 24(3)2023 Jan 17.
Artigo em Inglês | MEDLINE | ID: mdl-36768144

RESUMO

In our experience, keratinocytes cultured in feeder-free conditions and in commercially available defined and serum-free media cannot be as efficiently massively expanded as their counterparts grown in conventional bovine serum-containing medium, nor can they properly form a stratified epidermis in a skin substitute model. We thus tested a new chemically defined serum-free medium, which we developed for massive human primary keratinocyte expansion and skin substitute production. Our medium, named Surge Serum-Free Medium (Surge SFM), was developed to be used alongside a feeder layer. It supports the growth of keratinocytes freshly isolated from a skin biopsy and cryopreserved primary keratinocytes in cultured monolayers over multiple passages. We also show that keratin-19-positive epithelial stem cells are retained through serial passaging in Surge SFM cultures. Transcriptomic analyses suggest that gene expression is similar between keratinocytes cultured with either Surge SFM or the conventional serum-containing medium. Additionally, Surge SFM can be used to produce bilayered self-assembled skin substitutes histologically similar to those produced using serum-containing medium. Furthermore, these substitutes were grafted onto athymic mice and persisted for up to six months. In conclusion, our new chemically defined serum-free keratinocyte culture medium shows great promise for basic research and clinical applications.


Assuntos
Queratinócitos , Engenharia Tecidual , Animais , Camundongos , Humanos , Queratinócitos/metabolismo , Pele/metabolismo , Epiderme/metabolismo , Células Epidérmicas , Meios de Cultura Livres de Soro/farmacologia , Células Cultivadas
6.
Int J Mol Sci ; 23(10)2022 May 14.
Artigo em Inglês | MEDLINE | ID: mdl-35628318

RESUMO

The efficacy of skin substitutes is established for the treatment of burn injuries, but its use is not limited to this condition. This technology has the potential to improve the treatment of various conditions by offering highly advanced and personalized treatments. In vivo studies are challenging but essential to move to clinical use in humans. Mice are the most widely used species in preclinical studies, but the main drawback of this model is the limited surface area of the graft in long-term transplantation studies caused by the displacement and the contraction of the graft. We improved the conventional surgical procedures by stabilizing the chamber covering the graft with intramuscular sutures and by adding a tie-over bolster dressing. The current study was therefore performed to compare outcomes of skin grafts between the conventional and optimized skin graft model. Human self-assembled skin substitutes (SASSs) were prepared and grafted to athymic mice either by the conventional method or by the new grafting method. Graft healing and complications were assessed using digital photographs on postoperative days 7, 14, and 21. Similar structure and organization were observed by histological staining. The new grafting method reduced medium and large displacement events by 1.26-fold and medium and large contraction events by 1.8-fold, leading to a 1.6-fold increase in graft surface area compared to skin substitutes grafted with the usual method. This innovation ensures better reproducibility and consistency of skin substitute transplants on mice.


Assuntos
Pele Artificial , Animais , Bandagens , Xenoenxertos , Humanos , Camundongos , Camundongos Nus , Reprodutibilidade dos Testes
7.
Curr Protoc ; 2(1): e353, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-35085429

RESUMO

Efficient gene transfer into cultured fibroblasts and keratinocytes during retroviral transduction is a critical step toward the treatment of genodermatoses such as epidermolysis bullosa. However, achieving high transduction rates is still a difficult task, particularly for the insertion of large coding sequences for which high viral titers cannot always be obtained. Multiple polycationic molecules, such as polybrene, which has been used in several clinical trials, have the ability to boost ex vivo retroviral gene transfer. However, the use of polybrene has been associated with a reduction of the proliferation and growth potential of human keratinocytes in culture. We developed a method for the efficient retroviral transduction of primary fibroblasts and keratinocytes using EF-c, a polycationic nanofibril-forming peptide. In comparison with polybrene, we found that the retroviral transduction efficiency with EF-c was increased 2.5- to 3.2-fold for fibroblasts, but not for keratinocytes. Moreover, the use of EF-c did not affect fibroblast proliferation and keratinocyte stem cell content, whereas polybrene induced a decrease in both. This method could have a positive impact on the development of ex vivo gene correction of genodermatoses, allowing for more efficient gene transfer into primary skin cells with little to no effect on proliferation and stem cell content. © 2022 Wiley Periodicals LLC. Basic Protocol: Fibroblast and keratinocyte transduction Support Protocol: Assessment of transduction efficiency through flow cytometry analysis.


Assuntos
Vetores Genéticos , Retroviridae , Peptídeo C , Humanos , Queratinócitos , Retroviridae/genética , Pele
8.
Tissue Eng Part C Methods ; 26(3): 180-189, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-32085694

RESUMO

Innovative therapies combining gene-corrected stem cells and the production of bioengineered tissues to treat epidermolysis bullosa are emerging. However, quantitative tests to measure the adhesion forces between two highly viscoelastic substrates such as those found in bilayered bioengineered skin are needed and are still lacking. The objective of this study was to develop a mechanical test to measure the dermal-epidermal adhesion strength of our bilayered tissue-engineered skin substitute (TES) produced with the self-assembly method. We developed a peel test, which allows the displacement of both skin layers in a T configuration, based on the ASTM International standard. A MATLAB program was written to process and analyze raw data. The experimental setup was tested by measuring the dermal-epidermal adhesion strength in TESs produced with normal or collagen VII-deficient cells. Our peel testing method allowed us to detect the impact of the absence of collagen VII in the dermal-epidermal adhesion strength of TESs and also to examine the progression of the dermal-epidermal adhesion strength in relation to culture time in normal TES. Impact statement This study describes a method for assessing the adhesion strength at the dermal-epidermal junction of individual tissue-engineered skin substitute (TES). An ASTM standardized protocol of peel testing was designed to measure this important mechanical property. Our innovative approach will serve as a quality control in the production, improvement, and application of TESs for the treatment of pathologies affecting the dermal-epidermal adhesion such as epidermolysis bullosa. Data presented contribute to research on the interfaces between biological substrates and provide a reference factor for the characterization of products derived from tissue engineering.


Assuntos
Derme/fisiologia , Epiderme/fisiologia , Engenharia Tecidual/métodos , Adesividade , Adolescente , Adulto , Derme/ultraestrutura , Epiderme/ultraestrutura , Feminino , Humanos , Lactente , Masculino , Pessoa de Meia-Idade , Pele Artificial
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...