Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
1.
Phys Rev Lett ; 128(25): 250402, 2022 Jun 24.
Artigo em Inglês | MEDLINE | ID: mdl-35802452

RESUMO

We probe local phase fluctuations of trapped two-dimensional Bose gases using matter-wave interferometry. This enables us to measure the phase correlation function, which changes from an algebraic to an exponential decay when the system crosses the Berezinskii-Kosterlitz-Thouless (BKT) transition. We determine the temperature dependence of the BKT exponent η and find the critical value η_{c}=0.17(3) for our trapped system. Furthermore, we measure the local vortex density as a function of the local phase-space density, which shows a scale-invariant behavior across the transition. Our experimental investigation is supported by Monte Carlo simulations and provides a comprehensive understanding of the BKT transition in a trapped system.

2.
Ann Biomed Eng ; 45(12): 2921-2932, 2017 12.
Artigo em Inglês | MEDLINE | ID: mdl-28905268

RESUMO

We present a comprehensive and original framework for the biomechanical analysis of patients affected by ascending thoracic aorta aneurysm and aortic insufficiency. Our aim is to obtain crucial indications about the role played by deranged hemodynamics on the ATAAs risk of rupture. Computational fluid dynamics analysis was performed using patient-specific geometries and boundary conditions derived from 4D MRI. Blood flow helicity and wall shear stress descriptors were assessed. A bulge inflation test was carried out in vitro on the 4 ATAAs after surgical repair. The healthy volunteers showed no eccentric blood flow, a mean TAWSS of 1.5 ± 0.3 Pa and mean OSI of 0.325 ± 0.025. In 3 aneurismal patients, jet flow impingement on the aortic wall resulted in large TAWSS values and low OSI which were amplified by the AI degree. However, the tissue strength did not appear to be significantly reduced. The fourth patient, which showed the lowest TAWSS due to the absence of jet flow, had the smallest strength in vitro. Interestingly this patient presented a bovine arch abnormality. Jet flow impingement with high WSS values is frequent in ATAAs and our methodology seems to be appropriate for determining whether it may increase the risk of rupture or not.


Assuntos
Aorta Torácica/fisiopatologia , Aneurisma da Aorta Torácica/fisiopatologia , Estenose da Valva Aórtica/fisiopatologia , Velocidade do Fluxo Sanguíneo , Pressão Sanguínea , Modelos Cardiovasculares , Adulto , Idoso , Aneurisma da Aorta Torácica/complicações , Aneurisma da Aorta Torácica/diagnóstico por imagem , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/etiologia , Simulação por Computador , Feminino , Humanos , Angiografia por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Resistência ao Cisalhamento , Estresse Mecânico
3.
Int J Cardiovasc Imaging ; 33(8): 1213-1221, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28299607

RESUMO

Bicuspid aortic valve (BAV) disease is heterogeneous and related to valve dysfunction and aortopathy. Appropriate follow up and surveillance of patients with BAV may depend on correct phenotypic categorization. There are multiple classification schemes, however a need exists to comprehensively capture commissure fusion, leaflet asymmetry, and valve orifice orientation. Our aim was to develop a BAV classification scheme for use at MRI to ascertain the frequency of different phenotypes and the consistency of BAV classification. The BAV classification scheme builds on the Sievers surgical BAV classification, adding valve orifice orientation, partial leaflet fusion and leaflet asymmetry. A single observer successfully applied this classification to 386 of 398 Cardiac MRI studies. Repeatability of categorization was ascertained with intraobserver and interobserver kappa scores. Sensitivity and specificity of MRI findings was determined from operative reports, where available. Fusion of the right and left leaflets accounted for over half of all cases. Partial leaflet fusion was seen in 46% of patients. Good interobserver agreement was seen for orientation of the valve opening (κ = 0.90), type (κ = 0.72) and presence of partial fusion (κ = 0.83, p < 0.0001). Retrospective review of operative notes showed sensitivity and specificity for orientation (90, 93%) and for Sievers type (73, 87%). The proposed BAV classification schema was assessed by MRI for its reliability to classify valve morphology in addition to illustrating the wide heterogeneity of leaflet size, orifice orientation, and commissural fusion. The classification may be helpful in further understanding the relationship between valve morphology, flow derangement and aortopathy.


Assuntos
Valva Aórtica/anormalidades , Doenças das Valvas Cardíacas/diagnóstico por imagem , Imagem Cinética por Ressonância Magnética , Terminologia como Assunto , Adulto , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Doença da Válvula Aórtica Bicúspide , Técnicas de Imagem de Sincronização Cardíaca , Eletrocardiografia , Estudos de Viabilidade , Feminino , Doenças das Valvas Cardíacas/classificação , Doenças das Valvas Cardíacas/fisiopatologia , Humanos , Angiografia por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Fenótipo , Valor Preditivo dos Testes , Reprodutibilidade dos Testes
4.
Clin Radiol ; 71(8): 779-95, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26944696

RESUMO

Magnetic resonance imaging (MRI) techniques provide non-invasive and non-ionising methods for the highly accurate anatomical depiction of the heart and vessels throughout the cardiac cycle. In addition, the intrinsic sensitivity of MRI to motion offers the unique ability to acquire spatially registered blood flow simultaneously with the morphological data, within a single measurement. In clinical routine, flow MRI is typically accomplished using methods that resolve two spatial dimensions in individual planes and encode the time-resolved velocity in one principal direction, typically oriented perpendicular to the two-dimensional (2D) section. This review describes recently developed advanced MRI flow techniques, which allow for more comprehensive evaluation of blood flow characteristics, such as real-time flow imaging, 2D multiple-venc phase contrast MRI, four-dimensional (4D) flow MRI, quantification of complex haemodynamic properties, and highly accelerated flow imaging. Emerging techniques and novel applications are explored. In addition, applications of these new techniques for the improved evaluation of cardiovascular (aorta, pulmonary arteries, congenital heart disease, atrial fibrillation, coronary arteries) as well as cerebrovascular disease (intra-cranial arteries and veins) are presented.


Assuntos
Doenças Cardiovasculares/diagnóstico por imagem , Transtornos Cerebrovasculares/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Angiografia por Ressonância Magnética/métodos , Imagem Cinética por Ressonância Magnética/métodos , Humanos , Aumento da Imagem/métodos
5.
Magn Reson Med ; 71(4): 1542-53, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23716466

RESUMO

PURPOSE: Changes in aortic geometry or presence of aortic valve (AoV) disease can result in substantially altered aortic hemodynamics. Dilatation of the ascending aorta or AoV abnormalities can result in an increase in helical flow. METHODS: 4D flow magnetic resonance imaging was used to test the feasibility of quantitative helicity analysis using equidistantly distributed 2D planes along the entire aorta. The evaluation of the method included three parts: (1) the quantification of helicity in 12 healthy subjects, (2) an evaluation of observer variability and test-retest reliability, and (3) the quantification of helical flow in 16 patients with congenitally altered bicuspid AoVs. RESULTS: Helicity quantification in healthy subjects revealed consistent directions of flow rotation along the entire aorta with high clockwise helicity in the aortic arch and an opposite rotation sense in the ascending and descending aorta. The results demonstrated good scan-rescan and inter- and intraobserver agreement of the helicity parameters. Helicity quantification in patients revealed a significant increase in absolute peak relative helicity during systole and a considerably greater heterogeneous distribution of mean helicity in the aorta. CONCLUSION: The method has the potential to serve as a reference distribution for comparisons of helical flow between healthy subjects and patients or between different patient groups.


Assuntos
Aorta/patologia , Aorta/fisiopatologia , Valva Aórtica/anormalidades , Doenças das Valvas Cardíacas/patologia , Doenças das Valvas Cardíacas/fisiopatologia , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Angiografia por Ressonância Magnética/métodos , Adulto , Valva Aórtica/patologia , Valva Aórtica/fisiopatologia , Doença da Válvula Aórtica Bicúspide , Velocidade do Fluxo Sanguíneo , Técnicas de Imagem de Sincronização Cardíaca/métodos , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
6.
Eur Radiol ; 23(12): 3361-9, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23812310

RESUMO

OBJECTIVES: To test the feasibility of four-dimensional (4D) flow MRI to quantify the systolic wall shear stress (WSSsystole) and oscillatory shear index (OSI) in high-grade internal carotid artery (ICA) stenosis before and after endarterectomy (CEA). METHODS: Twenty patients with ≥60 % ICA stenosis were prospectively and consequently included. Four-dimensional flow MRI was used to measure individual time-resolved 3D blood flow velocities. Segmental WSSsystole and OSI were derived at eight wall segments in analysis planes positioned along the ICA, common (CCA) and external carotid artery (ECA). RESULTS: Regional WSSsystole of all patients decreased after CEA (P < 0.05). Changes were most prominent at the ICA bulb but remained unchanged in the CCA and ECA. OSI was significantly lower after CEA in the lateral vessel walls (P < 0.05). For analysis planes at the stenosis in- and outlet, a reduction of mean WSSsystole by 32 % and 52 % (P < 0.001) and OSI distal to the stenosis (40 %, P = 0.01) was found after CEA. CONCLUSIONS: Our findings show the potential of in vivo 4D flow MRI to quantify haemodynamic changes in wall shear stress even in patients with complex flow conditions.


Assuntos
Artéria Carótida Interna/fisiopatologia , Estenose das Carótidas/fisiopatologia , Estenose das Carótidas/cirurgia , Endarterectomia das Carótidas , Hemodinâmica , Imageamento por Ressonância Magnética , Idoso , Velocidade do Fluxo Sanguíneo , Artéria Carótida Interna/patologia , Artéria Carótida Interna/cirurgia , Estenose das Carótidas/diagnóstico , Estudos de Viabilidade , Feminino , Humanos , Masculino , Estudos Prospectivos , Estresse Mecânico , Sístole
7.
Rev. mex. ing. bioméd ; 34(3): 243-259, abr. 2013. ilus, tab
Artigo em Inglês | LILACS-Express | LILACS | ID: lil-740158

RESUMO

Cardiovascular magnetic resonance (CMR) has become a valuable tool to corroborate aortic stenosis (AS) severity when echocardiography assessment is discordant. Moreover, CMR can provide useful complementary information about AS severity and hemodynamic markers. In particular, the use of advanced 4D flow CMR allows a comprehensive assessment of complex flow alterations produced by AS. This review provides an overview of the added value obtained by standard 2D flow and advanced 4D flow quantification for AS severity assessment and discusses the advantages and disadvantages of current clinical metrics. This includes an introduction of promising new hemodynamic markers, and discusses how these novel makers may identify potential complications and disease progression in patients with AS.


La imagenología de resonancia magnética cardiovascular (RMC) se ha establecido como una importante herramienta para corroborar la severidad de la estenosis aórtica (EA) cuando el examen por ecocardiografía es contradictorio. Además, la RMC puede proveer importante información complementaria con respecto a la severidad de la EA y diversos indicadores hemodinámicos. En particular, el uso de técnicas avanzadas de flujo en 4D por RMC permite una extensiva evaluación de las complejas alteraciones de flujo provocadas por la presencia de la EA. Este artículo de revisión describe de manera detallada el valor agregado obtenido en la práctica clínica con el uso de las técnicas de medición de flujo bidimensionales, así como las técnicas avanzadas de flujo en 4D para la cuantificación y evaluación de la severidad de la EA. De igual modo, se discuten las ventajas y desventajas de los parámetros clínicos comúnmente utilizados para la estratificación de la severidad de la EA. Además, incluye una introducción a nuevos y prometedores índices hemodinámicos, discute su utilidad para la identificación de potenciales complicaciones y de progresión de la EA in vivo.

8.
Bioorg Med Chem Lett ; 11(14): 1911-4, 2001 Jul 23.
Artigo em Inglês | MEDLINE | ID: mdl-11459659

RESUMO

This paper describes the development of the epidermal growth factor receptor tyrosine kinase inhibitor ZD1839 from a lead series of 4-anilinoquinazoline compounds. ZD1839 has suitable properties for use as a clinically effective drug and shows activity against human tumours. In particular, the use of pharmacokinetic data in the development of ZD1839 is discussed.


Assuntos
Antineoplásicos/síntese química , Antineoplásicos/farmacologia , Receptores ErbB/antagonistas & inibidores , Quinazolinas/farmacologia , Administração Oral , Carcinoma de Células Escamosas/metabolismo , Gefitinibe , Humanos , Células KB/citologia , Quinazolinas/síntese química , Sensibilidade e Especificidade , Células Tumorais Cultivadas/citologia , Células Tumorais Cultivadas/metabolismo
9.
Breast Cancer Res Treat ; 38(1): 67-73, 1996.
Artigo em Inglês | MEDLINE | ID: mdl-8825124

RESUMO

Since the mitogenic action of EGF is mediated by ligand-induced autophosphorylation of the EGF receptor (EGFR), and EGFR is commonly overexpressed in solid human tumours, inhibitors of receptor tyrosine kinase activity (RTK) could prove to be effective antitumour agents. Screening of a compound library using an EGF-RTK enzyme prepared from human tumour derived A431 cells identified a series of potent (IC50 < 1 microM) enzyme inhibitors. These inhibitors are quinazolines bearing a variety of substituted anilines at the 4-position. The most potent 4-anilinoquinazolines (IC50 approximately equal to 20 nM) have small non-polar meta substituents on the aniline ring, and are competitive with ATP and non-competitive with substrate. The growth inhibitory activity of these agents was assessed in vitro using KB cells (human oral squamous tumour) grown in the absence or presence of EGF. A selected compound, 4-(3-chloroanilino)quinazoline (CAQ), inhibited EGF-stimulated growth in a concentration dependent manner and complete blockade was observed at concentrations (1-10 microM) which had no effect on basal growth. Selectivity of growth inhibition by CAQ was further exemplified in IGF1-stimulated KB cells where no effect was detected at concentrations which completely blocked EGF-stimulated growth. Similarly, CAQ blocked TGF alpha-stimulated growth in MCF-7 human breast cancer cells without affecting insulin-stimulated growth. These studies define a novel class of EGF-RTK inhibitors which are also potent and selective inhibitors of EGF-stimulated human tumour cell growth in vitro.


Assuntos
Antineoplásicos/farmacologia , Inibidores Enzimáticos/farmacologia , Receptores ErbB/antagonistas & inibidores , Quinazolinas/farmacologia , Humanos , Células KB , Relação Estrutura-Atividade , Células Tumorais Cultivadas
11.
J Med Chem ; 38(6): 994-1004, 1995 Mar 17.
Artigo em Inglês | MEDLINE | ID: mdl-7699716

RESUMO

The synthesis of a series of analogues of the potent thymidylate synthase (TS) inhibitor N-[4-[N-[(3,4-dihydro-2-methyl-4-oxo-6- quinazolinyl)methyl]-N-prop-2-ynylamino]benzoyl]-L-glutamic acid (ICI 198583, 1) is described in which the glutamic acid residue has been replaced by other alpha-amino acids. Most of these analogues were prepared by coupling of tert-butyl-4-(prop-2-ynylamino)benzoate (37) with 6-(bromomethyl)-3,4-dihydro-2-methyl-4-oxoquinazoline (34) followed by deprotection of the tert-butyl ester to the acid and azide-mediated coupling to the appropriate amino acid or amino acid ester. In cases where the amino acid ester was unreactive with the acid azide, a modification was used in which the quinazolinone moiety was protected as its 3-(pivaloyloxy)methyl derivative. This permitted the generation of the more reactive acid chloride of the p-aminobenzoate unit. In general these modifications result in compounds that have equivalent potency to 1 as inhibitors of isolated TS except where the amino acid lacks a lipophilic alpha-substituent. These compounds appear to require the reduced folate carrier (RFC) for transport into cells, but since they are not converted intracellularly into polyglutamated forms, they have a lower level of cytotoxicity compared to 1. The removal of the alpha-carboxylic acid has given a second set of analogues of 1 which contain simple alkyl amide, benzyl, substituted benzyl, and heterocyclic benzyl amide derivatives. These are considerably less potent than 1 as TS inhibitors but display 1-10 microM cytotoxicities due to the fact that they do not require RFC transport and can presumably readily enter cells by passive diffusion through the cell membrane. Molecular modeling and NMR studies indicated that the incorporation of, respectively, 7-methyl and 2'-fluoro substituents would favor the optimum conformation of these molecules for interaction with the TS enzyme. Accordingly, these substituents were incorporated into selected examples to give the series of analogues 47-55. These all show enhanced (approximately 10-fold) inhibition of TS compared to their unsubstituted counterparts. In the substituted benzylamides (51, 52) and heterocyclic benzyl amides (53-55) the ability to enter cells by passive diffusion results in highly potent (< 1 microM) cytotoxic agents.


Assuntos
Antineoplásicos/síntese química , Antineoplásicos/farmacologia , Antagonistas do Ácido Fólico/síntese química , Antagonistas do Ácido Fólico/farmacologia , Ácido Glutâmico/química , Quinazolinas/síntese química , Quinazolinas/farmacologia , Timidilato Sintase/antagonistas & inibidores , Animais , Antineoplásicos/química , Ácido Fólico/análogos & derivados , Ácido Fólico/farmacologia , Antagonistas do Ácido Fólico/química , Leucemia L1210/tratamento farmacológico , Leucemia L1210/enzimologia , Camundongos , Quinazolinas/química , Relação Estrutura-Atividade , Células Tumorais Cultivadas
12.
Mil Med ; 159(12): 723-9, 1994 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-7723994

RESUMO

The U.S. Coast Guard rescued 525 Chinese nationals and ten Indonesian crewmen from the disabled motor vessel East Wood. They were participating in a human smuggling operation. Subjected to a trying ordeal at sea, these individuals were at great risk to life and health but survived remarkably well because of their good health, age, and mutual cooperation. The U.S. military organized the joint task force, Operation Provide Refuge, to provide humanitarian aid. The task force rapidly mobilized resources to support camp development on Kwajalein Island and provide nutrition and health care to the stranded travelers. Preventive Medicine personnel, called in at the beginning of the operation, helped develop a healthy campsite, which contributed to a relatively uneventful refugee experience. Close liaison with the local medical resources on Kwajalein was essential to the success of the operation.


Assuntos
Militares , Refugiados , Trabalho de Resgate/organização & administração , China , Feminino , Havaí , Nível de Saúde , Humanos , Masculino
13.
J Med Chem ; 35(15): 2761-8, 1992 Jul 24.
Artigo em Inglês | MEDLINE | ID: mdl-1495009

RESUMO

Modifications to the bicyclic ring system of the potent thymidylate synthase (TS) inhibitor N-[4-[N-[(2-amino-3,4-dihydro-4-oxo-6- quinazolinyl)methyl]-N-prop-2-ynylamino]benzoyl]-L-glutamic acid (1, CB3717) have led to the synthesis of a series of quinoline antifolates bearing a variety of substituents at the C2 and C4 positions. In general the synthetic route involved the coupling of the appropriate diethyl N-[4-(prop-2-ynylamino)benzoyl]-L-glutamate with a disubstituted 6-(bromomethyl)quinoline followed by deprotection using mild alkali. The compounds were tested as inhibitors of partially purified L1210 TS. As a measure of cytotoxicity, the compounds were tested for their inhibition of the growth of L1210 cells in culture. Good enzyme inhibition and cytotoxicity were found for compounds containing chloro, amino, or methyl substituents at the C2 position with chloro or bromo substituents at C4. The effect on enzyme inhibition of varying the N10 substituent of 2h was similar to that observed in the quinazolinone-containing antifolates, indicating that the quinoline compounds may be interacting with the enzyme in a similar way to the quinazolinones. Also, the introduction of a 2'-fluoro substituent into the benzoyl ring of several of the quinoline antifolates led to an increase in both TS inhibition and the inhibition of L1210 cell growth. These data demonstrate that the N3-H of the pyrimidine ring of the quinazolinone antifolates is not required for binding to TS if appropriate substituents are placed at the C2 and C4 positions of the bicyclic ring system.


Assuntos
Antagonistas do Ácido Fólico/farmacologia , Ácido Fólico/análogos & derivados , Quinazolinas/farmacologia , Timidilato Sintase/antagonistas & inibidores , Animais , Sobrevivência Celular/efeitos dos fármacos , Ácido Fólico/química , Ácido Fólico/farmacologia , Antagonistas do Ácido Fólico/química , Leucemia L1210/enzimologia , Camundongos , Quinazolinas/química , Relação Estrutura-Atividade , Células Tumorais Cultivadas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...