Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Analyst ; 146(9): 2834-2841, 2021 May 04.
Artigo em Inglês | MEDLINE | ID: mdl-33949440

RESUMO

We present a one-step fabrication method for a new multiplexed electrospray emitter with nine parallel micronozzles. The nozzles were formed by wet chemical etching of the end of a microstructured silica fiber containing nine 10 µm flow channels. By carefully adjusting the water flow through the channels while etching, we controlled the shape of the conical micronozzles and were able to obtain conditions under which the micronozzles, together with the flow channels, formed optical micro-axicon lenses. When 1064 nm light was guided through the flow channels and focused by the micro-axicon lenses into the Taylor cones, we were able to increase the desolvation of a model analyte and thereby increased the spray current produced by the emitter. This work paves the way towards a rapidly modulated mass-spectrometry source having a greatly enhanced throughput.

2.
Nanotechnology ; 27(42): 424004, 2016 10 21.
Artigo em Inglês | MEDLINE | ID: mdl-27641834

RESUMO

Several mathematical models exist in the literature to describe the properties of optical resonators. Here, coupled mode theory and coherent superposition theory are compared and their consistency is demonstrated as they are applied to phase-shift cavity ring-down measurements in optical (micro-)cavities. In the particular case of a whispering gallery mode in a microsphere cavity these models are applied to transmission measurements and backscattering measurements through the fiber taper that couples light into the microresonator. It is shown that both models produce identical relations when applied to these traveling wave cavities.

3.
Opt Express ; 24(13): 14086-99, 2016 Jun 27.
Artigo em Inglês | MEDLINE | ID: mdl-27410569

RESUMO

We describe an in-fiber interferometer based on a gas-filled hollow-core photonic crystal fiber. Expressions for the sensitivity, figure of merit and refractive index resolution are derived, and values are experimentally measured and theoretically validated using mode field calculations. The refractive indices of nine monoatomic and molecular gases are measured with a resolution of δns < 10-6.

4.
Soft Matter ; 11(45): 8746-57, 2015 Dec 07.
Artigo em Inglês | MEDLINE | ID: mdl-26458138

RESUMO

The uptake and release of sorbates into films and coatings is typically accompanied by changes of the films' refractive index and thickness. We provide a comprehensive model to calculate the concentration of the sorbate from the average refractive index and the film thickness, and validate the model experimentally. The mass fraction of the analyte partitioned into a film is described quantitatively by the Lorentz-Lorenz equation and the Clausius-Mosotti equation. To validate the model, the uptake kinetics of water and other solvents into SU-8 films (d = 40-45 µm) were explored. Large-angle interferometric refractometry measurements can be used to characterize films that are between 15 µm to 150 µm thick and, Fourier analysis, is used to determine independently the thickness, the average refractive index and the refractive index at the film-substrate interface at one-second time intervals. From these values the mass fraction of water in SU-8 was calculated. The kinetics were best described by two independent uptake processes having different rates. Each process followed one-dimensional Fickian diffusion kinetics with diffusion coefficients for water into SU-8 photoresist film of 5.67 × 10(-9) cm(2) s(-1) and 61.2 × 10(-9) cm(2) s(-1).

5.
Opt Express ; 22(16): 19337-47, 2014 Aug 11.
Artigo em Inglês | MEDLINE | ID: mdl-25321018

RESUMO

A fiber laser using a thulium-doped ZBLAN gain medium was used to generate laser radiation simultaneously at 1461, 1505 and 1874 nm, with > 5 mW output power at each of the wavelengths. The laser was used to quantify the near-infrared absorption of liquid water in acetone. Additionally, near-infrared spectra were recorded using a broad band source and were interpreted using parallel factor (PARAFAC) analysis to rationalize the concentration-dependent peak shifts.

6.
Anal Chem ; 85(9): 4328-34, 2013 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-23480430

RESUMO

Short liquid core waveguides (LCWs) were included into a fiber-loop cavity ring-down absorption spectrometer to reduce the detection limit over, both, single pass absorption in a LCW and cavity-enhanced absorption using a conventional fiber-loop cavity. LCWs of 5 and 10 cm length were interfaced with a pressure-flow system and a multimode fiber-loop cavity using concave fiber lenses with matching numerical apertures and diameters. Two red dyes, Allura Red AC and Congo Red, were detected with a 532 nm pulsed laser at a 5 nM limit of detection in a detection volume of less than 1 µL, corresponding to a minimal detectable absorbance of less than 4 × 10(-4) cm(-1) and a minimal detectable change in absorption cross section, σ(min) = V(det) × Îµ × C(LOD), of about 14 µm(2) (Allura Red AC) and 37 µm(2) (Congo Red).


Assuntos
Cobalto/análise , DNA/análise , Compostos Ferrosos/química , Compostos Orgânicos/análise , Permanganato de Potássio/análise , Lasers , Dióxido de Silício/química , Espectrometria de Fluorescência
7.
Opt Lett ; 38(3): 365-7, 2013 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-23381439

RESUMO

We report a method for real-time monitoring of vapor uptake by simultaneous detection of the refractive index, n, and thickness, d, of thin transparent films with a precision of δn=10(-4) and δd<100 nm. The setup combines total internal reflection (Abbé) refractometry with an interferometric imaging method. A fast Fourier transform and phase fitting method is applied for accurate and independent determination of refractive indices and thicknesses. While the uptake of acetone vapor by polydimethylsiloxane is investigated, the system is also suited for characterization of other solid and liquid films.

8.
Analyst ; 137(12): 2782-90, 2012 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-22479699

RESUMO

Excitation emission matrix (EEM) and cavity ring-down (CRD) spectral signatures have been used to detect and quantitatively assess contamination of jet fuels with aero-turbine lubricating oil. The EEM spectrometer has been fiber-coupled to permit in situ measurements of jet turbine oil contamination of jet fuel. Parallel Factor (PARAFAC) analysis as well as Principal Component Analysis and Regression (PCA/PCR) were used to quantify oil contamination in a range from the limit of detection (10 ppm) to 1000 ppm. Fiber-loop cavity ring-down spectroscopy using a pulsed 355 nm laser was used to quantify the oil contamination in the range of 400 ppm to 100,000 ppm. Both methods in combination therefore permit the detection of oil contamination with a linear dynamic range of about 10,000.

9.
Opt Express ; 19(25): 25057-65, 2011 Dec 05.
Artigo em Inglês | MEDLINE | ID: mdl-22273897

RESUMO

A low-noise transducer based on a fiber Fabry-Perot (FFP) cavity was used as a pickup for an acoustic guitar. A distributed feedback (DFB) laser was locked to a 25 MHz-wide resonance of the FFP cavity using the Pound-Drever-Hall method. The correction signal was used as the audio output and was preamplified and sampled at up to 96 kHz. The pickup system is largely immune against optical noise sources, exhibits a flat frequency response from the infrasound region to about 25 kHz, and has a distortion-free audio output range of about 50 dB.


Assuntos
Acústica/instrumentação , Lasers , Música , Fibras Ópticas , Transdutores , Desenho de Equipamento , Análise de Falha de Equipamento
10.
Sensors (Basel) ; 10(3): 1716-42, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-22294895

RESUMO

Waveguide-based cavity ring-down spectroscopy (CRD) can be used for quantitative measurements of chemical concentrations in small amounts of liquid, in gases or in films. The change in ring-down time can be correlated to analyte concentration when using fiber optic sensing elements that change their attenuation in dependence of either sample absorption or refractive index. Two types of fiber cavities, i.e., fiber loops and fiber strands containing reflective elements, are distinguished. Both types of cavities were coupled to a variety of chemical sensor elements, which are discussed and compared.


Assuntos
Tecnologia de Fibra Óptica , Análise Espectral , Eletroforese Capilar , Técnicas Analíticas Microfluídicas , Refratometria
11.
Sensors (Basel) ; 10(3): 1823-45, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-22294902

RESUMO

An overview on high-resolution and fast interrogation of optical-fiber sensors relying on laser reflection spectroscopy is given. Fiber Bragg-gratings (FBGs) and FBG resonators built in fibers of different types are used for strain, temperature and acceleration measurements using heterodyne-detection and optical frequency-locking techniques. Silica fiber-ring cavities are used for chemical sensing based on evanescent-wave spectroscopy. Various arrangements for signal recovery and noise reduction, as an extension of most typical spectroscopic techniques, are illustrated and results on detection performances are presented.


Assuntos
Tecnologia de Fibra Óptica , Lasers , Fibras Ópticas , Análise Espectral , Birrefringência
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...