Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 152
Filtrar
2.
Arq Bras Cardiol ; 121(4): e20230544, 2024.
Artigo em Português, Inglês | MEDLINE | ID: mdl-38695471

RESUMO

BACKGROUND: Ablation Index (AI) software has allowed better atrial fibrillation (AF) ablation results, but recurrence rates remain significant. Specific serum biomarkers have been associated with this recurrence. OBJECTIVES: To evaluate whether certain biomarkers could be used (either individually or combined) to predict arrhythmia recurrence after AI-guided AF ablation. METHODS: Prospective multicenter observational study of consecutive patients referred for AF ablation from January 2018 to March 2021. Hemoglobin, brain natriuretic peptide (BNP), C-reactive protein, high sensitivity cardiac troponin I, creatinine clearance, thyroid-stimulating hormone (TSH) and free thyroxine (FT4) were assessed for their ability to predict arrhythmia recurrence during follow-up. Statistical significance was accepted for p values of<0.05. RESULTS: A total of 593 patients were included - 412 patients with paroxysmal AF and 181 with persistent AF. After a mean follow-up of 24±6 months, overall single-procedure freedom from atrial arrhythmia was 76.4%. Individually, all biomarkers had no or only modest predictive power for recurrence. However, a TSH value >1.8 µUI/mL (HR=1.82 [95% CI, 1.89-2.80], p=0.006) was an independent predictor of arrhythmia recurrence. When assessing TSH, FT4 and BNP values in combination, each additional "abnormal" biomarker value was associated with a lower freedom from arrhythmia recurrence (87.1 % for no biomarker vs. 83.5% for one vs. 75.1% for two vs. 43.3% for three biomarkers, p<0.001). Patients with three "abnormal" biomarkers had a threefold higher risk of AF recurrence compared with no "abnormal" biomarker (HR=2.88 [95% CI, 1.39-5.17], p=0.003). CONCLUSIONS: When used in combination, abnormal TSH, FT4 and BNP values can be a useful tool for predicting arrhythmia recurrence after AI-guided AF ablation.


FUNDAMENTO: O software ablation index (AI) permitiu melhorar os resultados da ablação de fibrilação atrial (FA), mas as taxas de recorrência permanecem significativas. Biomarcadores séricos específicos têm sido associados a essa recorrência. OBJETIVOS: Avaliar se certos biomarcadores podem ser utilizados (individualmente ou combinados) para predizer a recorrência de FA pós ablação guiada pelo AI. MÉTODOS: Estudo multicêntrico, observacional, prospectivo de pacientes consecutivos, encaminhados para ablação de FA de janeiro de 2018 a março de 2021. Hemoglobina, peptídeo natriurético cerebral (BNP), proteína C reativa, troponina I ultrassensível, clearance de creatinina, Hormônio Tireoestimulante (TSH), e Tiroxina livre (T4) foram avaliados quanto à capacidade de prever a recorrência de arritmias durante o acompanhamento. Valores de p <0,05 foram aceitos como estatisticamente significativos. RESULTADOS: Um total de 593 pacientes foram incluídos ­ 412 com FA paroxística e 181 com FA persistente. Durante o seguimento médio de 24±6 meses, 76,4% não apresentaram recidiva após ablação. Individualmente, os biomarcadores demonstraram um valor preditivo baixo ou nulo para recorrência. No entanto, TSH >1,8 µUI/mL [HR=1,82 (IC95%, 1,89-2,80), p=0,006] foi um preditor independente de recorrência. Avaliando-se a combinação de TSH, FT4 e BNP, a adição de cada valor "anormal" foi associada a uma menor sobrevida livre de recorrência (87,1% se nenhum vs. 83,5% se um vs. 75,1% se dois vs. 43,3% se três biomarcadores, p<0,001). Doentes com três biomarcadores "anormais" apresentaram três vezes maior probabilidade de recorrência de FA, comparativamente aos que não apresentaram nenhum biomarcador "anormal" (HR=2,88 [IC95%, 1,39-5,17], p=0,003). CONCLUSÕES: Quando combinados, valores anormais de TSH, FT4 e BNP podem ser uma ferramenta útil para prever a recorrência de FA pós ablação guiada pelo AI.


Assuntos
Fibrilação Atrial , Biomarcadores , Ablação por Cateter , Recidiva , Tireotropina , Humanos , Fibrilação Atrial/cirurgia , Fibrilação Atrial/sangue , Biomarcadores/sangue , Masculino , Feminino , Estudos Prospectivos , Pessoa de Meia-Idade , Ablação por Cateter/métodos , Idoso , Tireotropina/sangue , Peptídeo Natriurético Encefálico/sangue , Valor Preditivo dos Testes , Proteína C-Reativa/análise , Resultado do Tratamento , Tiroxina/sangue , Fatores de Risco , Troponina I/sangue
5.
J Am Coll Cardiol ; 82(7): 590-599, 2023 08 15.
Artigo em Inglês | MEDLINE | ID: mdl-37558371

RESUMO

BACKGROUND: Very few data have been published on the use of subcutaneous implantable cardioverter-defibrillators (S-ICDs) in patients with congenital heart disease (CHD). OBJECTIVES: The aim of this study was to analyze outcomes associated with S-ICDs in patients with CHD. METHODS: This nationwide French cohort including all patients with an S-ICD was initiated in 2020 by the French Institute of Health and Medical Research. Characteristics at implantation and outcomes were analyzed in patients with CHD. RESULTS: From October 12, 2012, to December 31, 2019, among 4,924 patients receiving an S-ICD implant in 150 centers, 101 (2.1%) had CHD. Tetralogy of Fallot, univentricular heart, and dextro-transposition of the great arteries represented almost one-half of the population. Patients with CHD were significantly younger (age 37.1 ± 15.4 years vs 50.1 ± 14.9 years; P < 0.001), more frequently female (37.6% vs 23.0%; P < 0.001), more likely to receive an S-ICD for secondary prevention (72.3% vs 35.9%; P < 0.001), and less likely to have severe systolic dysfunction of the systemic ventricle (28.1% vs 53.1%; P < 0.001). Over a mean follow-up period of 1.9 years, 16 (15.8%) patients with CHD received at least 1 appropriate shock, with all shocks successfully terminating the ventricular arrhythmia. The crude risk of appropriate S-ICD shock was twice as high in patients with CHD compared with non-CHD patients (annual incidences of 9.0% vs 4.4%; HR: 2.1; 95% CI: 1.3-3.4); however, this association was no longer significant after propensity matching (especially considering S-ICD indication, P = 0.12). The burden of all complications (HR: 1.2; 95% CI: 0.7-2.1; P = 0.4) and inappropriate shocks (HR: 0.9; 95% CI: 0.4-2.0; P = 0.9) was comparable in both groups. CONCLUSIONS: In this nationwide study, patients with CHD represented 2% of all S-ICD implantations. Our findings emphasize the effectiveness and safety of S-ICD in this particularly high-risk population. (S-ICD French Cohort Study [HONEST]; NCT05302115).


Assuntos
Desfibriladores Implantáveis , Cardiopatias Congênitas , Transposição dos Grandes Vasos , Humanos , Feminino , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Desfibriladores Implantáveis/efeitos adversos , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/prevenção & controle , Morte Súbita Cardíaca/etiologia , Estudos de Coortes , Resultado do Tratamento , Estudos Retrospectivos , Cardiopatias Congênitas/complicações , Cardiopatias Congênitas/terapia
6.
Lancet ; 402(10405): 883-936, 2023 09 09.
Artigo em Inglês | MEDLINE | ID: mdl-37647926

RESUMO

Despite major advancements in cardiovascular medicine, sudden cardiac death (SCD) continues to be an enormous medical and societal challenge, claiming millions of lives every year. Efforts to prevent SCD are hampered by imperfect risk prediction and inadequate solutions to specifically address arrhythmogenesis. Although resuscitation strategies have witnessed substantial evolution, there is a need to strengthen the organisation of community interventions and emergency medical systems across varied locations and health-care structures. With all the technological and medical advances of the 21st century, the fact that survival from sudden cardiac arrest (SCA) remains lower than 10% in most parts of the world is unacceptable. Recognising this urgent need, the Lancet Commission on SCD was constituted, bringing together 30 international experts in varied disciplines. Consistent progress in tackling SCD will require a completely revamped approach to SCD prevention, with wide-sweeping policy changes that will empower the development of both governmental and community-based programmes to maximise survival from SCA, and to comprehensively attend to survivors and decedents' families after the event. International collaborative efforts that maximally leverage and connect the expertise of various research organisations will need to be prioritised to properly address identified gaps. The Commission places substantial emphasis on the need to develop a multidisciplinary strategy that encompasses all aspects of SCD prevention and treatment. The Commission provides a critical assessment of the current scientific efforts in the field, and puts forth key recommendations to challenge, activate, and intensify efforts by both the scientific and global community with new directions, research, and innovation to reduce the burden of SCD worldwide.


Assuntos
Fármacos Cardiovasculares , Morte Súbita Cardíaca , Humanos , Morte Súbita Cardíaca/prevenção & controle , Governo , Instalações de Saúde , Estudos Interdisciplinares
7.
Rev Port Cardiol ; 42(10): 821-829, 2023 10.
Artigo em Inglês, Português | MEDLINE | ID: mdl-37268266

RESUMO

INTRODUCTION AND OBJECTIVES: Cardioneuroablation (CNA), a technique based on radiofrequency ablation of cardiac vagal ganglia, was developed to treat recurrent vasovagal syncope (VVS) with a predominant cardioinhibitory component, as an alternative to pacemaker implantation. The aim of our study was to evaluate the safety and success rate of CNA guided by extracardiac vagal stimulation in patients with highly symptomatic cardioinhibitory VVS. METHODS: Prospective study of patients who underwent anatomically guided CNA at two cardiology centers. All patients had a history of recurrent syncope with a predominant cardioinhibitory component and refractory to conventional measures. Acute success was determined by the absence or significant reduction of cardiac parasympathetic response to extracardiac vagal stimulation. The primary endpoint was the recurrence of syncope during follow-up. RESULTS: In total, 19 patients (13 males; mean age 37.8±12.9 years) were included. Ablation was acutely successful in all patients. One patient had a convulsive episode after the procedure, which was deemed unrelated to the ablation, requiring admission to intensive care but without sequelae. No other complications occurred. At a mean follow-up of 21.0±13.2 months (range 3-42 months), 17 patients remained free of syncope. The remaining two patients had recurrence of syncope and, despite undergoing a new ablation procedure, required pacemaker implantation during follow-up. CONCLUSION: Cardioneuroablation, confirmed by extracardiac vagal stimulation, appears to be an effective and safe treatment option for highly symptomatic patients with refractory VVS with a predominant cardioinhibitory component, providing a new potential approach as an alternative to pacemaker implantation.


Assuntos
Marca-Passo Artificial , Síncope Vasovagal , Masculino , Humanos , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Síncope Vasovagal/cirurgia , Estudos Prospectivos , Coração , Progressão da Doença
8.
Europace ; 25(6)2023 06 02.
Artigo em Inglês | MEDLINE | ID: mdl-37345859

RESUMO

AIMS: Pulmonary vein isolation (PVI) guided by the Ablation Index (AI) has shown high acute and mid-term efficacy in the treatment of paroxysmal atrial fibrillation (AF). Previous data before the AI-era had suggested that wide-area circumferential ablation (WACA) was preferable to ostial ablation. However, with the use of AI, we hypothesize that ostial circumferential ablation is non-inferior to WACA and can improve outcomes in paroxysmal AF. METHODS AND RESULTS: Prospective, multicentre, non-randomized, non-inferiority study of consecutive patients were referred for paroxysmal AF ablation from January 2020 to September 2021. All procedures were performed using the AI software, and patients were separated into two different groups: WACA vs. ostial circumferential ablation. Acute reconnection, procedural data, and 1-year arrhythmia recurrence were assessed. During the enrolment period, 162 patients (64% males, mean age of 60 ± 11 years) fulfilled the study inclusion criteria-81 patients [304 pulmonary vein (PV)] in the WACA group and 81 patients (301 PV) in the ostial group. Acute PV reconnection was identified in 7.9% [95% confidence interval (CI), 4.9-11.1%] of PVs in the WACA group compared with 3.3% (95% CI, 1.8-6.1%) of PVs in the ostial group [P < 0.001 for non-inferiority; adjusted odds ratio 0.51 (95% CI, 0.23-0.83), P = 0.05]. Patients in the WACA group had longer ablation (35 vs. 29 min, P = 0.001) and procedure (121 vs. 102 min, P < 0.001) times. No significant difference in arrhythmia recurrence was seen at 1-year of follow-up [11.1% in WACA vs. 9.9% in ostial, hazard ratio 1.13 (95% CI, 0.44-1.94), P = 0.80 for superiority]. CONCLUSION: In paroxysmal AF patients treated with tailored AI-guided PVI, ostial circumferential ablation is not inferior to WACA with regard to acute PV reconnection, while allowing quicker procedures with less ablation time.


Assuntos
Fibrilação Atrial , Veias Pulmonares , Masculino , Humanos , Pessoa de Meia-Idade , Idoso , Feminino , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Estudos Prospectivos , Razão de Chances , Veias Pulmonares/cirurgia , Software
9.
Europace ; 25(5)2023 05 19.
Artigo em Inglês | MEDLINE | ID: mdl-37140046

RESUMO

AIMS: The aim of this study was to identify potential regional disparities in characteristics of implantable cardioverter-defibrillator (ICD) recipients, patient perceptions and perspectives after implantation and level of information provided to patients. METHODS AND RESULTS: The prospective, multicentre, and multinational European Heart Rhythm Association patient Survey 'Living with an ICD' included patients already implanted with an ICD (median ICD dwell time - 5 years, interquartile range 2-10). An online questionnaire was filled-in by patients invited from 10 European countries. A total of 1809 patients (the majority in their 40s to 70s, 65.5% men) were enrolled, with 877 (48.5%) from Western Europe (group 1), followed by 563 from Central/Eastern Europe (group 2, 31.1%), and 369 from Southern Europe (group 3, 20.4%). A total of 52.9% of Central/Eastern Europe patients reported increased satisfaction after ICD placement compared with 46.6% from Western and 33.1% from Southern Europe (1 vs. 2 P = 0.047, 1 vs. 3 P < 0.001, 2 vs. 3 P < 0.001). About 79.2% of Central/Eastern and 76.0% of Southern Europe patients felt optimally informed at the time of device implantation compared with just 64.6% from Western Europe (1 vs. 2 P < 0.001, 1 vs. 3 P < 0.001, 2 vs. 3 P = ns). CONCLUSIONS: While physicians in Southern Europe should address the patients' concerns about the impact of the ICD on quality of life, physicians from Western Europe should focus on improving the quality of information provided to their prospective ICD patients. Novel strategies to address regional differences in patients' quality of life and provision of information are warranted.


Assuntos
Desfibriladores Implantáveis , Masculino , Humanos , Feminino , Qualidade de Vida , Estudos Prospectivos , Inquéritos e Questionários , Europa (Continente)/epidemiologia
10.
Int J Cardiol ; 383: 33-39, 2023 07 15.
Artigo em Inglês | MEDLINE | ID: mdl-37116756

RESUMO

PURPOSE: We aim to evaluate whether the use of a multielectrode mapping catheter could lead to higher efficacy of premature ventricular contraction (PVC) ablation. METHODS: Prospective, multicenter nonrandomized study of consecutive patients referred for PVC ablation from January 2018 to June 2021. Patients were separated into two groups: activation map performed with the PentaRay catheter (Study group) or with the ablation catheter (Control group). PMF software was used in both groups. Procedural endpoints and 1-year freedom from ventricular arrhythmia were assessed. RESULTS: During the enrollment period 136 patients (60% males, mean age of 55 ± 17 years, 60% left-sided origin) fulfilled the inclusion criteria - 68 patients in each group. Patients in the Study Group had a sevenfold higher number of acquired activation points (768 ± 728 vs. 110 ± 79, p < 0.01), a shorter mapping time (28 ± 19 min vs. 49 ± 32 min, p < 0.01) and a quicker procedure time (110 ± 33 min vs. 134 ± 50 min, p < 0.01), compared to patients in the Control Group. While there were no significant differences in the acute success (95.6% in the Study Group vs. 90.1% in Control group, p = 0.49), or adverse events (4% in the Study group vs. 7% in the Control group, p = 0.72), patients in the Study group had a higher freedom from ventricular arrhythmia at 1-year (89.7% vs. 70.6%, p = 0.01). The use of the PentaRay catheter was an independent predictor of success (HR = 6.20 [95% CI, 1.08-35.47], p = 0.003). CONCLUSIONS: The use of the PentaRay catheter may improve the outcome of PVC ablation while reducing procedure time.


Assuntos
Ablação por Cateter , Complexos Ventriculares Prematuros , Masculino , Humanos , Adulto , Pessoa de Meia-Idade , Idoso , Feminino , Complexos Ventriculares Prematuros/diagnóstico , Complexos Ventriculares Prematuros/cirurgia , Estudos Prospectivos , Catéteres , Software , Fatores de Tempo , Ablação por Cateter/métodos , Resultado do Tratamento
11.
Artigo em Inglês | MEDLINE | ID: mdl-36981953

RESUMO

BACKGROUND: The aim of this study was to compare differences between Polish ICD recipients and ICD recipients from other European countries in terms of quality of life, information provision before ICD implantation, and end-of-life issues. METHODS: This is a sub-analysis of the "Living with an ICD" patient survey (25-item questionnaire) organized by the European Heart Rhythm Association between 12 April 2021 and 5 July 2021 in ten European countries. RESULTS: There were 410 (22.7%) patients from Poland and 1399 (77.3%) from other European countries. A total of 51.0% of Polish patients reported improvement in their quality of life compared with 44.3% in other countries (p = 0.041). Remote monitoring was three times more often utilized in other countries than in Poland (66.8% vs. 21.0%, p < 0.001). While 78.1% of Poles felt well informed before ICD implantation compared with 69.6% of subjects from other countries (p = 0.001), they were less familiar with the ICD deactivation process than others (38.9% vs. 52.5%, p < 0.001). CONCLUSIONS: Despite the less frequent use of remote monitoring and gaps in end-of-life issues, Polish ICD recipients reported more favorable quality of life and a higher level of information received before device placement than patients in other European countries.


Assuntos
Desfibriladores Implantáveis , Humanos , Polônia , Qualidade de Vida , Europa (Continente) , Inquéritos e Questionários
12.
Europace ; 25(3): 1144-1151, 2023 03 30.
Artigo em Inglês | MEDLINE | ID: mdl-36691111

RESUMO

AIMS: Information provided to patients prior to implantable cardioverter-defibrillator (ICD) insertion and their participation in the decision-making process are crucial for understanding ICD function and accepting this lifelong therapy. The aim of this study is to evaluate the extent to which different aspects related to ICD and quality of life were transmitted to patients prior to ICD implantation. METHODS AND RESULTS: Prospective, multicenter European study with an online questionnaire initiated by the European Heart Rhythm Association. The questionnaire was filled-in directly and personally by the ICD patients who were invited to participate. A total of 1809 patients (majority in their 40s-70s, with 624 women, 34.5%) from 10 European countries participated in the study. The median time from first ICD implantation was 5 years (interquartile range 2-10). Overall, 1155 patients (71.5%) felt optimally informed at the time of device implantation, however many respondents received no information about ICD-related complications (n = 801, 49.6%), driving restrictions (n = 718, 44.5%), and possibility of end-of-life ICD deactivation (n = 408, 25.4%). Of note, women were less frequently involved in the decision-making process than men (47.3% vs. 55.9%, P = 0.003) and reported to be less often optimally informed before ICD implantation than men (61.2% vs. 76.8%, P < 0.001). More women mentioned the desire to have learned more about ICD therapy and the benefit/risk balance (45.4% vs. 33.7% of men; P < 0.001). CONCLUSIONS: This patient-based evaluation provides alarming findings on the lack of information provided to patients prior ICD implantation, particularly for women.


Assuntos
Desfibriladores Implantáveis , Qualidade de Vida , Masculino , Humanos , Feminino , Estudos Prospectivos , Cardioversão Elétrica/efeitos adversos , Desfibriladores Implantáveis/efeitos adversos , Europa (Continente) , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle
14.
Europace ; 25(2): 627-633, 2023 02 16.
Artigo em Inglês | MEDLINE | ID: mdl-36256586

RESUMO

AIMS: Data on sports-related sudden cardiac arrest (SrSCA) among young adults in the general population are scarce. We aimed to determine the overall SrSCA incidence, characteristics, and outcomes in young adults. METHODS AND RESULTS: Prospective cohort study of all cases of SrSCA between 2012 and 2019 in Germany and Paris area, France, involving subjects aged 18-35 years. Detection of SrSCA was achieved via multiple sources, including emergency medical services (EMS) reporting and web-based screening of media releases. Cases and aetiologies were centrally adjudicated. Overall, a total of 147 SrSCA (mean age 28.1 ± 4.8 years, 95.2% males) occurred, with an overall burden of 4.77 [95% confidence interval (CI) 2.85-6.68] cases per million-year, including 12 (8.2%) cases in young competitive athletes. While bystander cardiopulmonary resuscitation (CPR) was initiated in 114 (82.6%), automated external defibrillator (AED) use by bystanders occurred only in a minority (7.5%). Public AED use prior to EMS arrival (odds ratio 6.25, 95% CI 1.48-43.20, P = 0.02) was the strongest independent predictor of survival at hospital discharge (38.1%). Among cases that benefited from both immediate bystander CPR and AED use, survival rate was 90.9%. Coronary artery disease was the most frequent aetiology (25.8%), mainly through acute coronary syndrome (86.9%). CONCLUSION: Sports-related sudden cardiac arrest in the young occurs mainly in recreational male sports participants. Public AED use remains disappointingly low, although survival may reach 90% among those who benefit from both bystander CPR and early defibrillation. Coronary artery disease is the most prevalent cause of SrSCA in young adults.


Assuntos
Reanimação Cardiopulmonar , Doença da Artéria Coronariana , Serviços Médicos de Emergência , Parada Cardíaca , Parada Cardíaca Extra-Hospitalar , Humanos , Masculino , Adulto Jovem , Adulto , Feminino , Reanimação Cardiopulmonar/métodos , Cardioversão Elétrica , Estudos Prospectivos , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores , Serviços Médicos de Emergência/métodos , Parada Cardíaca Extra-Hospitalar/diagnóstico , Parada Cardíaca Extra-Hospitalar/epidemiologia , Parada Cardíaca Extra-Hospitalar/terapia
15.
Int J Cardiol ; 370: 209-214, 2023 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-36228764

RESUMO

AIMS: To compare the two different ablation strategies, both guided by the Ablation Index (AI), in the setting of atrial fibrillation (AF) ablation: high-power short-duration (HPSD) ablation using 40 W on the posterior wall and 50 W elsewhere versus low-power long-duration (LPLD) using 25 W posteriorly and 35 W elsewhere. METHODS: Prospective, multicenter nonrandomized, noninferiority study of consecutive patients referred for paroxysmal AF ablation from January 2018 to July 2019. Ablation was guided by the AI (≥500 for anterior segments, ≥450 for the roof and inferior segments and 400 posteriorly) and an interlesion distance (ILD) ≤ 6 mm. Patients were separated into two groups: HPSD vs LPLD. Acute reconnection (after adenosine trial) and 2-year outcomes were assessed. RESULTS: 160 patients (61% males, median age of 62 [IQR 51-69] years), fulfilled the study inclusion criteria - 80 patients (316 pulmonary veins [PV]) in the HPSD group and 80 patients (314 PV) in the LPLD. The probability of acute PV reconnection was similar between both groups: 2.2% in HPSD, 95%CI 0.6% to 3.8% vs. 3.4% in LPLD, 95%CI 1.4% to 5.4%; p < 0.001 for noninferiority. Median PV ablation time (20 min vs 30 min, p < 0.01) and procedure duration (80 min vs 100 min, p < 0.001) were shorter in the HPSD group. After a median follow-up of 26 months, arrhythmia recurrence was similar between groups (17.5% in HPSD group vs. 18.8% in LPLD group, p = 0.79). CONCLUSIONS: In paroxysmal AF patients treated with the Ablation Index, a HPSD strategy is noninferior to the more standard LPLD ablation, while allowing for quicker procedures with shorter ablation times.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Masculino , Humanos , Pessoa de Meia-Idade , Idoso , Feminino , Estudos Prospectivos , Resultado do Tratamento , Veias Pulmonares/cirurgia , Ablação por Cateter/métodos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/etiologia , Recidiva
16.
Rev Port Cardiol ; 41(9): 783-789, 2022 Sep.
Artigo em Inglês, Português | MEDLINE | ID: mdl-36066275

RESUMO

Amiodarone is the most potent antiarrhythmic drug available and is commonly prescribed to treat and prevent not only life-threatening ventricular arrhythmias but also atrial fibrillation (AF). The latest European Society of Cardiology AF guidelines state that amiodarone is recommended for long-term rhythm control in all AF patients but that other antiarrhythmic drugs should be considered first whenever possible, due to its extracardiac toxicity. In patients without significant or with only minimal structural heart disease, amiodarone is not listed as a possibility in their therapeutic scheme. Still, amiodarone is widely and liberally used, and is the most prescribed antiarrhythmic drug for patients with AF despite its high toxicity profile. Non-cardiovascular death was more frequent with amiodarone treatment than with a rate control strategy in AFFIRM, while meta-analyses suggest an association between amiodarone use in patients without structural heart disease and increased non-cardiovascular mortality. Severe or even fatal outcomes due to amiodarone may occur years after treatment initiation and are often not acknowledged by the prescribing physician, who may no longer be following the patient. The lack of widely accepted diagnostic criteria and symptom definitions may lead to underestimation of the incidence of severe side effects and of its toxicity. Unlike the underestimated risk of toxicity with amiodarone, severe complications associated with catheter ablation are usually directly ascribed to the treatment even by non-medical personnel, possibly resulting in overestimation of risks. This brief review will address the issue of amiodarone overuse and the frequent underestimation of its toxicity, while suggesting scenarios in which its use is entirely reasonable, and compare it with catheter ablation.

17.
Europace ; 24(10): 1684-1690, 2022 10 13.
Artigo em Inglês | MEDLINE | ID: mdl-35942585

RESUMO

The use of a blanking period (BP) after an atrial fibrillation (AF) ablation procedure is a common practice, but recent data questions the benign nature of early recurrences of atrial tachyarrhythmias (ERATs). A physician-based survey was carried out by the European Heart Rhythm Association (EHRA) to investigate the current definition and applicability of BP and ERAT management. An online questionnaire was sent to clinical and interventional electrophysiologists. A total of 436 respondents (88% interventional electrophysiologists) reported observing ERATs in 25% (interquartile range 15-35) of patients, less commonly in paroxysmal AF (PAF) compared with persistent AF (persAF). The median reported duration of BP used by respondents was 90 days, with 22% preferring a shorter BP duration for PAF patients compared with persAF. Half of the patients with ERATs are expected to also experience late recurrences (LR). Isolated episodes of ERATs are treated conservatively by 99% of the respondents, but repeat ablation during the BP is preferred by 20% of electrophysiologists for multiple ERATs and by 16% in patients with organized atrial tachyarrhythmias. In conclusion, ERATs are commonly observed after AF ablation, particularly in persAF patients, and are perceived as predictors of LR by half of the respondents. A general adherence to a 90-day BP duration was observed. During this time period, ERAT is mainly treated conservatively, but repeat ablation during the BP is occasionally offered to patients with multiple ERATs and those with organized atrial tachyarrhythmias.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Criocirurgia/métodos , Humanos , Veias Pulmonares/cirurgia , Recidiva , Inquéritos e Questionários , Resultado do Tratamento
18.
J Cardiovasc Electrophysiol ; 33(8): 1725-1733, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35637604

RESUMO

PURPOSE: Since the widespread availability of contact-force sensing catheters, the need for a waiting period after pulmonary vein isolation (PVI) has not been reassessed. We aim to evaluate whether a waiting period is still necessary after PVI guided by the ablation Index (AI). METHODS: Prospective, multicenter, randomized study of consecutive patients referred for paroxysmal atrial fibrillation (AF) ablation from May 2019 to February 2020. Patients were randomized in a 1:1 ratio to PVI with versus without a waiting period of 20 min. Acute pulmonary vein (PV) reconnection after adenosine challenge was the primary endpoint. A per-protocol analysis was designed to determine whether a strategy of dismissing the waiting period after PVI was noninferior to waiting for 20 min for identifying acute PV reconnection. PVI was guided by tailored AI values and an interlesion distance ≤6 mm. RESULTS: During the enrollment period, 167 patients (56% males, mean age of 57 ± 14 years) fulfilled the study inclusion criteria - 84 patients (308 PV) in the waiting period group (Group A) and 83 patients (314 PV) in the group without a waiting period (Group B). Acute PV reconnection was identified in 3.8% (95% confidence interval [CI], 1.7%-5.9%) of PVs in the study group B compared to 2.9% (95% CI, 1.0%-4.8%) of PVs in the Group A (p = .002 for non-inferiority). At 1-year follow-up, there was no significant difference in arrhythmia recurrence between groups (9.5% in Group A vs. 9.6% in Group B, hazard ratio: 1.03 [95% CI, 0.39-2.73], p = .98). CONCLUSION: In paroxysmal AF patients submitted to ablation, a tailored PVI guided by the AI rendered a 20-min waiting period unnecessary.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Adulto , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Veias Pulmonares/cirurgia , Recidiva , Software , Resultado do Tratamento
19.
J Interv Card Electrophysiol ; 65(1): 115-121, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35469051

RESUMO

BACKGROUND: There are conflicting data regarding the relationship between high-sensitivity cardiac Troponin I (Hs-cTnI) and the ablation effectiveness quotient (AEQ) with arrhythmia recurrence following atrial fibrillation (AF) ablation. Our goals were to evaluate the impact of the Ablation Index (AI) software on Hs-cTnI and AEQ levels and to assess whether these markers are predictors of arrhythmia recurrence. METHODS: Prospective single-center study of 75 consecutive patients referred for paroxysmal AF ablation from October 2017 to January 2019. Procedural endpoints and 2-year outcomes were assessed and compared to those of 75 propensity score-matched patients submitted to non-AI-guided pulmonary vein isolation (PVI) [control group]. RESULTS: Compared to the control group, patients having AI-guided PVI had lower Hs-cTnI values (1580 [IQR 1180-2140] ng/L vs. 2600 [IQR 1840 - 3900], p < 0.001) and a lower AEQ (0.9 [IQR 0.6-1.2] ng/L/s vs. 1.4 [0.8-1.6] ng/L/s, p < 0.001). After a median follow-up of 26 (IQR 20-32) months, there was a significant reduction in arrhythmia recurrence in the AI group (15% vs. 31%, HR 0.67 [95% CI, 0.32-1.40], p = 0.02). However, neither Hs-cTnI nor AEQ was predictors of arrhythmia recurrence in AI-guided PVI. CONCLUSIONS: The use of the AI software led to reduced levels of Hs-cTnI and lower AEQ in AF patients submitted to PVI. However, none of these markers predicted arrhythmia recurrence.


Assuntos
Arritmias Cardíacas , Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Arritmias Cardíacas/cirurgia , Fibrilação Atrial/cirurgia , Biomarcadores , Humanos , Estudos Prospectivos , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento , Troponina I
20.
Europace ; 24(7): 1179-1185, 2022 07 21.
Artigo em Inglês | MEDLINE | ID: mdl-35348646

RESUMO

Conduction disorders such as left bundle branch block (LBBB) are common after transcatheter aortic valve implantation (TAVI). Consensus regarding a reasonable strategy to manage conduction disturbances after TAVI has been elusive. The European Heart Rhythm Association (EHRA) conducted a survey to capture contemporary clinical practice for conduction disorders after TAVI. A 25-item online questionnaire was developed and distributed among the EHRA electrophysiology (EP) research network centres. Of 117 respondents, 44% were affiliated with university hospitals. A standardized management protocol for advanced conduction disorders such as LBBB or atrioventricular block (AVB) after TAVI was available in 63% of participating centres. Telemetry after TAVI was chosen as the most frequent management strategy for patients with new-onset or pre-existing LBBB (79% and 70%, respectively). Duration of telemetry in patients with new-onset LBBB varied, with a 48-h period being the most frequently chosen, but almost half monitoring continued for at least 72 h. Similarly, in patients undergoing EP study due to new-onset LBBB, the HV interval cut-off point leading to pacemaker implantation was heterogeneous among European centres, although an HV >75 ms threshold was the most common. Conduction system pacing was chosen as a preferred approach by 3.7% of respondents for patients with LBBB and normal left ventricular ejection fraction (LVEF), and by 5.6% for patients with LBBB and reduced LVEF. This survey suggests some heterogenity in the management of conduction disorders after TAVI across European centres. The risk stratification strategies vary substantially. Conduction system pacing in patients with LBBB after TAVI is still underused.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter , Valva Aórtica , Estenose da Valva Aórtica/cirurgia , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/epidemiologia , Arritmias Cardíacas/etiologia , Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/epidemiologia , Bloqueio de Ramo/etiologia , Doença do Sistema de Condução Cardíaco/diagnóstico , Doença do Sistema de Condução Cardíaco/epidemiologia , Doença do Sistema de Condução Cardíaco/terapia , Humanos , Volume Sistólico , Inquéritos e Questionários , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento , Função Ventricular Esquerda
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...