Artigo em Inglês | MEDLINE | ID: mdl-36197419

RESUMO

We described a MRSA bloodstream infection outbreak that was rapidly identified and controlled in a Neonatal Intensive Care Unit after implementation of a bundle of measures, including PCR-screening and HCW decolonization. We found 35% of healthcare workers(HCW) colonized with S. aureus by PCR, one of them that presented skin lesion positive for MSSA (same clone and spa type than two patients). Our findings raise the hypothesis that the outbreak could be related to HCW colonization.


Assuntos
Infecção Hospitalar , Staphylococcus aureus Resistente à Meticilina , Infecções Estafilocócicas , Infecção Hospitalar/diagnóstico , Infecção Hospitalar/epidemiologia , Infecção Hospitalar/prevenção & controle , Países Desenvolvidos , Surtos de Doenças/prevenção & controle , Humanos , Recém-Nascido , Controle de Infecções , Unidades de Terapia Intensiva Neonatal , Staphylococcus aureus Resistente à Meticilina/genética , Infecções Estafilocócicas/diagnóstico , Infecções Estafilocócicas/epidemiologia , Staphylococcus aureus
2.
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1406887

RESUMO

ABSTRACT We described a MRSA bloodstream infection outbreak that was rapidly identified and controlled in a Neonatal Intensive Care Unit after implementation of a bundle of measures, including PCR-screening and HCW decolonization. We found 35% of healthcare workers(HCW) colonized with S. aureus by PCR, one of them that presented skin lesion positive for MSSA (same clone and spa type than two patients). Our findings raise the hypothesis that the outbreak could be related to HCW colonization.

3.
Am J Infect Control ; 49(4): 512-515, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33080363

RESUMO

This study assessed the disinfection using 70% ethanol; H2O2-quaternary ammonium salt mixture; 0.1% sodium hypochlorite and autoclaving of four 3D-printed face shields with different designs, visor materials; and visor thickness (0.5-0.75 mm). We also investigated their clinical suitability by applying a questionnaire to health workers (HW) who used them. Each type of disinfection was done 40 times on each type of mask without physical damage. In contrast, autoclaving led to appreciable damage.


Assuntos
COVID-19/prevenção & controle , Desinfetantes/farmacologia , Desinfecção/métodos , Equipamento de Proteção Individual/virologia , Impressão Tridimensional , SARS-CoV-2 , COVID-19/epidemiologia , Coleta de Dados , Desenho de Equipamento , Etanol/farmacologia , Pessoal de Saúde , Humanos , Peróxido de Hidrogênio/farmacologia , Hipoclorito de Sódio/farmacologia