1.
EuroIntervention ; 6(5): 630-7, 2010 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-21044918

RESUMO

AIMS: In a rabbit denudation model, assess impact of strut thickness on arterial healing by comparing endothelial cell coverage and strut tissue coverage after implantation of bare metal stents of varying thickness; evaluate the effect of an everolimus-eluting stent. METHODS AND RESULTS: Strut tissue coverage and endothelialisation were assessed 14 and 21 days after implantation with scanning electron microscopy quantitation methods and immunostaining against the endothelial cell marker PECAM-1 (CD-31). At 14 days, strut tissue coverage was higher with the stainless steel Liberté stent (88%, 97 µm) versus Express (77%, 132 µm). The platinum chromium Element stent with the thinnest strut (81 µm) had the highest level (95%). By 21 days endothelialisation was complete for all. The everolimus-eluting Element stent had a 1-week delay in luminal endothelialisation but was >89% by 21 days; strut endothelial coverage was >79% in 80% (4/5) of animals, with total strut tissue coverage >95%. CONCLUSIONS: This study demonstrated that strut thickness affects strut tissue coverage post stent implantation and the addition of an everolimus-eluting polymer introduces a short delay in endothelialisation. The results highlight the need to control for aspects of stent design such as strut thickness when comparing across drug-eluting stent platforms.


Assuntos
Angioplastia Coronária com Balão , Vasos Coronários/patologia , Stents Farmacológicos , Células Endoteliais/patologia , Imunossupressores/administração & dosagem , Sirolimo/análogos & derivados , Stents , Animais , Cromo , Vasos Coronários/ultraestrutura , Células Endoteliais/fisiologia , Everolimo , Feminino , Metais , Microscopia Eletrônica de Varredura , Molécula-1 de Adesão Celular Endotelial a Plaquetas/análise , Platina , Desenho de Prótese , Coelhos , Sirolimo/administração & dosagem
2.
EuroIntervention ; 6(4): 512-9, 2010 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-20884440

RESUMO

AIMS: In a non-injured porcine coronary artery model, the aim was to evaluate vascular compatibility of the novel platinum chromium everolimus-eluting PROMUS Element stent as compared to the following control stents: everolimus-eluting PROMUS (XIENCE V), bare metal Element, and polymer-only Element. METHODS AND RESULTS: Stent pairs (n=228) evenly distributed among the four stent types were implanted in overlap configuration in 79 pigs at a targeted stent-to-artery ratio of 1.1:1. Similar numbers were explanted at each of 7, 30, 90, 180, and 270 days for pathological analysis. No stent-related mortality or morbidity was observed. There were no stent occlusions or strut fractures. The PROMUS Element was more radiopaque than PROMUS (relative densities 9.9 and 9.1, respectively) and demonstrated at all time points vascular compatibility similar to that of the control stents for endothelial cell coverage, inflammatory response, and neointima formation. At 30 days, parastrut fibrin was mild but greater (P<0.0001) for the drug-eluting stents than either for the bare metal or the polymer-only Element; however, by 90 days the fibrin had dissipated. CONCLUSIONS: In the non-injured porcine coronary artery model, the PROMUS Element demonstrated vascular compatibility equivalent to PROMUS and the bare metal and polymer-only stents.


Assuntos
Doença da Artéria Coronariana/terapia , Vasos Coronários/patologia , Stents Farmacológicos , Imunossupressores/administração & dosagem , Sirolimo/análogos & derivados , Animais , Stents Farmacológicos/efeitos adversos , Everolimo , Sirolimo/administração & dosagem , Suínos , Fatores de Tempo
3.
Curr Pharm Des ; 16(36): 3989-4001, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-21208187

RESUMO

Coronary artery disease is commonly characterized by atherosclerotic obstruction of vessels responsible for providing adequate blood supply to the myocardium. Disruption of atheromatous plaques can promote thrombosis, significant reductions in cardiac perfusion, and devastating acute (i.e, death) or chronic (i.e., congestive heart failure) consequences. Minimally invasive, catheter-based techniques have been implemented throughout the past three decades and include balloon angioplasty and stent implantation, to alleviate occlusive plaque burden in coronary vessels. Yet, these techniques have not come without complication, namely the tendency for vessels to re-occlude, or undergo restenosis. This manifestation is characterized by acute physical and longer-lasting cellular/biochemical components. To maximize clinical effectiveness, researchers and clinicians have exploited recognition that use of a rigid bare metal stent bound to a drug-bearing polymer, or so-called drug-eluting stent (DES), is best to combat the mechanical and biological contributors to restenosis. In this report, we review restenosis factors in detail, the corresponding rationale for drug choice for DES, and the results of trials conducted with such DES agents. Particular emphasis is given to paclitaxel, a natural compound included on a first-generation DES (Taxus® Express(2)®) made available for clinical use by Boston Scientific Corporation. We use paclitaxel as a model to illustrate alternatives for drug delivery to coronary vessels, broad concerns about DES use in the context of disease backgrounds, such as diabetes, and suggestions related to the continuing evolution of DES.


Assuntos
Proliferação de Células/efeitos dos fármacos , Constrição Patológica/prevenção & controle , Doença da Artéria Coronariana/prevenção & controle , Doença da Artéria Coronariana/patologia , Humanos , Paclitaxel/administração & dosagem , Paclitaxel/farmacologia , Stents
4.
J Mater Sci Mater Med ; 20(7): 1553-62, 2009 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-19259791

RESUMO

Functional aspects of the styrene-b-isobutylene-b-styrene triblock copolymer (SIBS) which is incorporated into a drug-eluting stent (DES) coating are described. The SIBS copolymer is employed on the TAXUS Paclitaxel-Eluting Coronary Stent as a carrier for paclitaxel (PTx). Optical and scanning electron microscopic analysis of stents explanted from rabbit and porcine models after 2 years and 6 months, respectively, showed that the SIBS coating maintained physical integrity. Gel permeation chromatography (GPC) of the copolymer extracted from the coating verified that no polymer degradation occurred over the same period of time. The coating on TAXUS Stents was shown to maintain physical integrity after 400 million cycles of pulsatile or mechanical (tensile) fatigue, simulating 10 years real time use. Inspection of the samples compared to untested controls showed no change in the coating under these cyclic simulated conditions. Films prepared with the same formulation found on TAXUS Stents maintained mechanical strength and resistance throughout the time of testing. Intentional defects introduced into the stent coating were shown to have only a minimal impact on PTx release. These data support the suitability of the SIBS copolymer as a drug carrier for DES applications.


Assuntos
Prótese Vascular/efeitos adversos , Vasos Coronários/patologia , Vasos Coronários/cirurgia , Stents Farmacológicos/efeitos adversos , Artéria Ilíaca/patologia , Artéria Ilíaca/cirurgia , Paclitaxel/administração & dosagem , Animais , Reestenose Coronária/etiologia , Reestenose Coronária/patologia , Reestenose Coronária/prevenção & controle , Estabilidade de Medicamentos , Efeitos Colaterais e Reações Adversas Relacionados a Medicamentos , Desenho de Equipamento , Análise de Falha de Equipamento , Segurança de Equipamentos , Masculino , Coelhos , Resultado do Tratamento
5.
Biomaterials ; 29(4): 448-60, 2008 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-17980425

RESUMO

Poly(Styrene-block-IsoButylene-block-Styrene) ("SIBS") is a biostable thermoplastic elastomer with physical properties that overlap silicone rubber and polyurethane. Initial data collected with SIBS stent-grafts and coatings on metallic stents demonstrate hemocompatibility, biocompatibility and long-term stability in contact with metal. SIBS has been used successfully as the carrier for a drug-eluting coronary stent; specifically Boston Scientific's TAXUS stent, and its uses are being investigated for ophthalmic implants to treat glaucoma, synthetic heart valves to possibly replace tissue valves and other applications. At present, researchers developing medical devices utilizing SIBS have found the following: (1) SIBS does not substantially activate platelets in the vascular system; (2) polymorphonuclear leukocytes in large numbers are not commonly observed around SIBS implants in the vascular system or in subcutaneous implants or in the eye; (3) myofibroblasts, scarring and encapsulation are not clinically significant with SIBS implanted in the eye; (4) embrittlement has not been observed in any implant location; (5) calcification within the polymer has not been observed; and (6) degradation has not been observed in any living system to date. Some deficiencies of SIBS that need to be addressed include creep deformation in certain load-bearing applications and certain sterilization requirements. The reason for the excellent biocompatibility of SIBS may be due to the inertness of SIBS and lack of cleavable moieties that could be chemotactic towards phagocytes.


Assuntos
Materiais Biocompatíveis , Tecnologia Biomédica , Poliestirenos , Animais , Valva Aórtica/cirurgia , Materiais Biocompatíveis/química , Materiais Biocompatíveis/metabolismo , Portadores de Fármacos/química , Humanos , Preparações Farmacêuticas , Poliestirenos/química , Poliestirenos/metabolismo
6.
Cell Cycle ; 5(14): 1574-9, 2006 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-16861892

RESUMO

The anti-cancer agent paclitaxel (PTX) is an effective anti-restenosis agent on drug eluting stents, primarily due to growth inhibition of coronary artery smooth muscle cells (CASMC) across a wide dose range. In this study, we compared the effects of PTX on CASMC to apoptotic-prone HL60 leukemia cells and apoptotic-reluctant A549 lung cancer cells to assess cell survival mechanisms. In comparison to HL60 and A549 cells, CASMC had a shorter mitotic arrest and a lower mitotic index. While CASMC and A549 cells did not become apoptotic and displayed a multi-nucleated phenotype, HL60 cells showed prolonged mitotic arrest followed by apoptosis. CASMC exiting mitosis were arrested in G1 as MN tetraploid cells, with decreased levels of cyclin B1 and PCNA. CASMC remained metabolically active, becoming permanently arrested as evidenced by increased levels of beta-galactosidase activity. These cells did not demonstrate elevated levels of inflammatory markers. Our findings suggest that a weak mitotic checkpoint or inhibited apoptotic cascade, or a combination of both, determine cell survival following PTX treatment. These in vitro findings suggest a mechanism for the cytostatic activity of PTX in CASMC for the inhibition of restenosis.


Assuntos
Apoptose/efeitos dos fármacos , Vasos Coronários/citologia , Mitose/efeitos dos fármacos , Miócitos de Músculo Liso/efeitos dos fármacos , Neoplasias/patologia , Paclitaxel/farmacologia , Linhagem Celular Tumoral , Células Cultivadas , Reestenose Coronária/tratamento farmacológico , Fase G1 , Células HL-60 , Humanos , Miócitos de Músculo Liso/citologia , Neoplasias/tratamento farmacológico
7.
Adv Drug Deliv Rev ; 58(3): 412-36, 2006 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-16647782

RESUMO

The advent of drug-eluting stents (DES) has provided the medical community with a technology that is transforming the treatment of coronary artery disease. As the newest treatment modality available to the interventional cardiologist, drug-eluting stents have not only significantly reduced the risk of restenosis, but they are also allowing the interventionalists to treat more complex lesions in patients that would otherwise require more invasive bypass surgery. Development of these drug-device combination products has presented considerable challenges to the device industry because it involves a multi-disciplinary approach that combines conventional device design and manufacturing with the principles of controlled local drug delivery. This review article provides an in-depth discussion of the key elements of drug-eluting stents, focusing on the TAXUS paclitaxel-eluting stent as an example of this new class of product. Specific sections will review the drug and polymer matrix components, formulation development and evaluation, pre-clinical studies and clinical trial results.


Assuntos
Preparações de Ação Retardada/uso terapêutico , Paclitaxel/uso terapêutico , Stents , Animais , Antineoplásicos Fitogênicos/uso terapêutico , Humanos , Ensaios Clínicos Controlados Aleatórios como Assunto , Taxus/química
8.
Cardiovasc Intervent Radiol ; 28(3): 331-7, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-15886949

RESUMO

PURPOSE: To evaluate the efficacy of NF-kappa B oligonucleotides (ODN) administered by local administration with the channeled balloon catheter to prevent restenosis after balloon angioplasty in restenotic iliac arteries of New Zealand white rabbits. MATERIALS AND METHODS: In vitro, 8000 rabbit vascular smooth muscle cells (rVSMC) where transfected with a liposomal carrier (TfX50) with 100 ng of decoy and scrambled ODN. Inhibition of proliferation was measured using a MTT assay after 24 hours in comparison to control. In vivo, 22 male New Zealand White rabbits were fed a 1% cholesterol diet and received denudation of both common iliac arteries with a 3 mm balloon catheter to induce an arterial stenosis. Four weeks after stenosis induction, local application of NF-kappa B in two different concentrations (1 mug: n = 14; 10 mug: n = 8) was performed randomly on one common iliac artery. Scrambled oligonucleotides without specific binding capacities were injected into the contralateral side. The channeled balloon catheter allows simultaneous balloon dilation (8 atm) of the stenosis and local application of a drug solution (2 atm). Four weeks after local drug delivery the animals were killed and the vessels were excised and computerized morphometric measurements were performed. RESULTS: NF-kappa B decoy ODN but not scrambled ODN inhibited proliferation of rVSMC in vitro. Following local ODN application in the animals, no acute vascular complications were seen. NF-kappa B ODN resulted in a statistically non significant reduction of neointimal area compared to the control group. The neointimal area was 0.97 mm(2) using 1 mug NF-kappa B ODN compared to 0.98 mm(2) in the control group. The higher dose resulted in a neointimal area of 0.97 mm(2) compared to 1.07 mm(2) at the control side. CONCLUSIONS: Local drug delivery of NF-kappa B ODN using the "channeled balloon" catheter could not reduce neointimal hyperplasia in stenostic rabbit iliac arteries. Application modalities have to be improved to enhance the effect of the local application to prevent restenosis after balloon angioplasty.


Assuntos
Angioplastia com Balão , Arteriopatias Oclusivas/prevenção & controle , Cateterismo , Artéria Ilíaca/efeitos dos fármacos , Oligodesoxirribonucleotídeos/administração & dosagem , Animais , Arteriopatias Oclusivas/patologia , Arteriopatias Oclusivas/terapia , Cateterismo/instrumentação , Proliferação de Células/efeitos dos fármacos , Células Cultivadas , Constrição Patológica/patologia , Constrição Patológica/prevenção & controle , Sistemas de Liberação de Medicamentos , Hiperplasia , Artéria Ilíaca/patologia , Masculino , Músculo Liso Vascular/efeitos dos fármacos , Músculo Liso Vascular/patologia , Coelhos , Distribuição Aleatória , Túnica Íntima/efeitos dos fármacos , Túnica Íntima/patologia
9.
Cell Cycle ; 3(8): 1050-6, 2004 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-15254417

RESUMO

Paclitaxel (PTX), a microtubule-active drug, causes mitotic arrest leading to apoptosis in certain tumor cell lines. Here we investigated the effects of PTX on human arterial smooth muscle cell (SMC) cells. In SMC, PTX caused both (a) primary arrest in G(1) and (b) post-mitotic arrest in G(1). Post-mitotic cells were multinucleated (MN) with either 2C (near-diploid) or 4C (tetraploid) DNA content. At PTX concentrations above 12 ng/ml, MN cells had 4C DNA content consistent with the lack of cytokinesis during abortive mitosis. Treatment with 6-12 ng/ml PTX yielded MN cells with 2C DNA content. Finally, 1-6 ng/ml of PTX, the lowest concentrations that affected cell proliferation, caused G(1) arrest without multinucleation. It is important that PTX did not cause apoptosis in SMC. The absence of apoptosis could be explained by mitotic exit and G(1) arrest as well as by low constitutive levels of caspase expression and by p53 and p21 induction. Thus, following transient mitotic arrest, SMC exit mitosis to form MN cells. These post-mitotic cells were subsequently arrested in G(1) but maintained normal elongated morphology and were viable for at least 21 days. We conclude that in SMC PTX causes post-mitotic cell cycle arrest rather than cell death.


Assuntos
Fase G1/efeitos dos fármacos , Músculo Liso Vascular/citologia , Miócitos de Músculo Liso/efeitos dos fármacos , Paclitaxel/farmacologia , Aorta/citologia , Apoptose/efeitos dos fármacos , Contagem de Células , Linhagem Celular , Proliferação de Células/efeitos dos fármacos , Sobrevivência Celular/efeitos dos fármacos , Sobrevivência Celular/fisiologia , Vasos Coronários/citologia , Células HL-60/química , Células HL-60/metabolismo , Células HL-60/patologia , Humanos , Células Jurkat/química , Células Jurkat/metabolismo , Células Jurkat/patologia , Mitose/efeitos dos fármacos , Músculo Liso Vascular/efeitos dos fármacos , Ploidias , Proteínas Proto-Oncogênicas p21(ras)/metabolismo
10.
Atherosclerosis ; 172(1): 71-8, 2004 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-14709359

RESUMO

BACKGROUND: Efficient local gene or drug therapy requires optimized application modalities to avoid vessel damage, which might lead to increased neointimal hyperplasia. Aim of the study was to evaluate different application parameters for local delivery using the channeled balloon catheter in order to minimize vessel trauma induced by local application. METHODS AND RESULTS: Sixty cholesterol fed rabbits were randomly enrolled into twelve groups of different local application parameters: group I, application pressure 2atm/application volume 1ml physiologic saline; group II, 2atm/2ml; group III, 2atm/5ml; group IV, 4atm/1ml; group V, 4atm/2ml; group VI, 4atm/5ml. The other six groups received Ringer's solution instead of saline. Administration of the solution was randomly performed in one iliac artery using the channeled balloon catheter with simultaneous balloon angioplasty (8atm). The contralateral iliac artery served as a control and was treated with balloon angioplasty only. Four weeks after local therapy, calibrated angiography was performed; the animals were sacrificed, vessel segments were excised and quantitative morphometric measurements were obtained. In none of the animals acute complications, e.g. dissection, thrombosis or perforation of the vessel, was noted. Up to an application pressure of 4atm and an application volume of 5ml, no significant neointima formation was seen compared to arteries which underwent angioplasty only. Additionally, no significant differences between saline and Ringer's solution were detected. In a multivariate analysis, neither application pressure nor volume were found to have a statistically significant influence on the amount of neointimal hyperplasia. CONCLUSIONS: Local application of "drugs" using the channeled balloon catheter is safe and feasible without significant induction of neointimal hyperplasia compared to angioplasty, if an application volume of 5ml and a pressure of 4atm is not exceeded.


Assuntos
Sistemas de Liberação de Medicamentos/métodos , Túnica Íntima/patologia , Angiografia , Angioplastia com Balão , Animais , Cateterismo , Sistemas de Liberação de Medicamentos/efeitos adversos , Hipercolesterolemia/patologia , Hiperplasia , Artéria Ilíaca , Masculino , Análise Multivariada , Coelhos , Distribuição Aleatória
11.
Cardiovasc Radiat Med ; 5(3): 136-41, 2004.
Artigo em Inglês | MEDLINE | ID: mdl-15721849

RESUMO

BACKGROUND: The advent of drug-eluting stents has provided the interventional cardiologist an effective new tool in treating coronary restenosis. There remains, however, a small group of patients that still require intervention following drug-eluting stent therapy. Currently, intravascular brachytherapy (IVBT) is approved for use in the treatment of in-stent restenosis (ISR). This study investigated the effect of gamma and beta radiation doses typically used in IVBT on the performance of the TAXUS Express(2) paclitaxel-eluting stent. METHODS AND RESULTS: It was determined that there were no statistically significant changes to in vitro paclitaxel release from stent exposed to radiation compared to controls subjected to the same conditions except for the radiation exposure. The molecular weight of the Translute polymer carrier matrix and the level of paclitaxel degradants were not changed following exposure to radiation doses up to twice what is typically used in IVBT. Beta and gamma radiation doses typically used in IVBT had no significant effect on the Translute polymer carrier, paclitaxel degradation, or paclitaxel release in this in vitro model. CONCLUSION: The data are encouraging and support further evaluation of the use of IVBT in the treatment of ISR in the presence of drug-eluting stents.


Assuntos
Braquiterapia , Reestenose Coronária/tratamento farmacológico , Reestenose Coronária/radioterapia , Portadores de Fármacos/efeitos da radiação , Paclitaxel/administração & dosagem , Polímeros/efeitos da radiação , Stents , Análise de Variância , Terapia Combinada , Humanos , Técnicas In Vitro , Modelos Lineares , Radiação Ionizante
12.
Catheter Cardiovasc Interv ; 55(3): 392-7, 2002 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-11870950

RESUMO

Direct intramyocardial injection may permit local delivery of protein and gene therapy agents for myocardial and coronary artery disease. Little is known about the immediate fate of materials administered via percutaneous endomyocardial catheters or via surgical epicardial injection. In this study, we use a novel method to evaluate the acute retention of agents injected directly into the myocardium, compare epicardial with the percutaneous endocardial and postmortem delivery, and evaluate the influence of injectate volume on myocardial retention. Fifteen 40-50 kg pigs underwent overlapping myocardial injections using a percutaneous endomyocardial catheter, an epicardial needle via an open chest, and epicardial needle postmortem. Multiple distinct 15 micro neutron-activated microsphere species were used as tracers. Two or three myocardial walls were injected in each animal using 3.5 mm, 27-28 gauge needles at varying injectate volumes. Animals were sacrificed immediately. Myocardial walls were divided and multiple microsphere species were quantified. In an additional study, nine 70 kg pigs underwent percutaneous endomyocardial injections with replication-deficient adenovirus encoding for the production of lac-Z. The injectate volume was varied, while the viral particle number remained constant. The animals were sacrificed 5 days after the percutaneous injections; the heart, liver, and spleen were collected for beta-galactosidase activity. Endomyocardial injection was associated with 43% +/- 15% microsphere retention, compared with 15% +/- 21% (P < 0.01) retention of open chest epicardial injection and 89% +/- 60% (P < 0.01) for postmortem injection. Reducing the injectate volume from 100 to 10 microL improved microsphere retention (P = 0.01). There was a trend toward improved viral transfection associated with smaller injection volumes. Despite direct intramyocardial administration, a significant fraction of injectate is not retained locally. Catheter-based needle endomyocardial injection is associated with equivalent or superior injectate retention compared with open chest epicardial injection. Proportionately, more injectate may be retained at lower volumes. Loss may involve a combination of channel leakage, venous, and lymphatic return.


Assuntos
Injeções/métodos , Miocárdio/metabolismo , Adenoviridae , Animais , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/métodos , Sistemas de Liberação de Medicamentos , Fluoroscopia , Técnicas de Transferência de Genes , Terapia Genética , Microesferas , Agulhas , Suínos , Transfecção/métodos , beta-Galactosidase/metabolismo