Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 124
Filtrar
1.
Europace ; 26(5)2024 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-38691562

RESUMO

AIMS: We examined whether thickness of the basal muscular interventricular septum (IVS), as measured by pre-procedural computed tomography (CT), could be used to identify the risk of conduction disturbances following transcatheter aortic valve replacement (TAVR). The IVS is a pivotal region of the electrical conduction system of the heart where the atrioventricular conduction axis is located. METHODS AND RESULTS: Included were 78 patients with severe aortic stenosis who underwent CT imaging prior to TAVR. The thickness of muscular IVS was measured in the coronal view, in systolic phases, at 1, 2, 5, and 10 mm below the membranous septum (MS). The primary endpoint was a composite of conduction disturbance following TAVR. Conduction disturbances occurred in 24 out of 78 patients (30.8%). Those with conduction disturbances were significantly more likely to have a thinner IVS than those without conduction disturbances at every measured IVS level (2.98 ± 0.52 mm vs. 3.38 ± 0.52 mm, 4.10 ± 1.02 mm vs. 4.65 ± 0.78 mm, 6.11 ± 1.12 mm vs. 6.88 ± 1.03 mm, and 9.72 ± 1.95 mm vs. 10.70 ± 1.55 mm for 1, 2, 5 and 10 mm below MS, respectively, P < 0.05 for all). Multivariable logistic regression analysis showed that pre-procedural IVS thickness (<4 mm at 2 mm below the MS) was a significant independent predictor of post-procedural conduction disturbance (adjOR 7.387, 95% CI: 2.003-27.244, P = 0.003). CONCLUSION: Pre-procedural CT assessment of basal IVS thickness is a novel predictive marker for the risk of conduction disturbances following TAVR. The IVS thickness potentially acts as an anatomical barrier protecting the underlying conduction system from mechanical compression during TAVR.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Septo Interventricular , Humanos , Masculino , Feminino , Substituição da Valva Aórtica Transcateter/efeitos adversos , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Septo Interventricular/diagnóstico por imagem , Idoso de 80 Anos ou mais , Fatores de Risco , Idoso , Arritmias Cardíacas/etiologia , Arritmias Cardíacas/fisiopatologia , Arritmias Cardíacas/diagnóstico por imagem , Sistema de Condução Cardíaco/fisiopatologia , Sistema de Condução Cardíaco/diagnóstico por imagem , Resultado do Tratamento , Valor Preditivo dos Testes , Medição de Risco , Índice de Gravidade de Doença , Estudos Retrospectivos , Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Tomografia Computadorizada Multidetectores , Tomografia Computadorizada por Raios X , Potenciais de Ação
4.
Am J Cardiol ; 191: 32-38, 2023 03 15.
Artigo em Inglês | MEDLINE | ID: mdl-36634547

RESUMO

Data are limited regarding the characteristics and outcomes of patients with cancer who are found eligible for primary defibrillator therapy. We performed a single-center retrospective analysis of patients with preexisting cancer diagnoses who become eligible for a primary prevention implantable cardioverter defibrillator (ICD) or cardiac resynchronization therapy (CRT) defibrillator. Multicenter Automatic Defibrillator Implantation Trial-ICD (MADIT-ICD) benefit scores were calculated. The study included 75 cancer patients at a median age of 73 (interquartile range 64, 81) years at heart failure diagnosis. Active cancer was present in 51%. Overall, 55% of the cohort had coronary artery disease and 37% were CRT eligible. We found that 48%, 49%, and 3% of cohorts had low, intermediate, and high MADIT-ICD Benefit scores, respectively. Only 27% of patients underwent primary defibrillator implantation. Using multivariate analysis, indication for CRT and intermediate/high MADIT-ICD Benefit categories were found as independent predictors for implantation (odds ratio 8.42 p <0.001 and odds ratio 3.74 p = 0.040, respectively). During a median follow-up of 5.3 (interquartile range 4.5, 7.2) years, one patient (5%) with a defibrillator had appropriate shock therapy and 2 patients (10%) had bacteremia. Of 13 patients with CRT defibrillator-implants, one patient was admitted for heart failure exacerbation (8%). Using a time-varying covariate model, we did not observe statistically significant differences in the survival of patients with cancer implanted versus those not implanted with primary defibrillators (hazard ratio 0.521, p = 0.127). In conclusion, although primary defibrillator therapy is underutilized in patients with cancer, its relative benefit is limited because of competing risk of nonarrhythmic mortality. These findings highlight the need for personalized cardiologic and oncologic coevaluation.


Assuntos
Terapia de Ressincronização Cardíaca , Desfibriladores Implantáveis , Insuficiência Cardíaca , Neoplasias , Humanos , Estudos Retrospectivos , Resultado do Tratamento , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/diagnóstico , Terapia de Ressincronização Cardíaca/efeitos adversos , Neoplasias/complicações , Neoplasias/terapia , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Prevenção Primária
5.
Front Cardiovasc Med ; 9: 988951, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36277779

RESUMO

Background: Risk stratification in long QT syndrome (LQTS) patients is important for optimizing patient care and informing clinical decision making. We developed a risk prediction algorithm with prediction of 5-year absolute risk of the first life-threatening arrhythmic event [defined as aborted cardiac arrest, sudden cardiac death, or appropriate implantable cardioverter defibrillator (ICD) shock] in LQTS patients, accounting for individual risk factors and their changes over time. Methods: Rochester-based LQTS Registry included the phenotypic cohort consisting of 1,509 LQTS patients with a QTc ≥ 470 ms, and the genotypic cohort including 1,288 patients with single LQT1, LQT2, or LQT3 mutation. We developed two separate risk prediction models which included pre-specified time-dependent covariates of beta-blocker use, syncope (never, syncope while off beta blockers, and syncope while on beta blockers), and sex by age < and ≥13 years, baseline QTc, and genotype (for the genotypic cohort only). Follow-up started from enrollment in the registry and was censored at patients' 50s birthday, date of death due to reasons other than sudden cardiac death, or last contact, whichever occurred first. The predictive models were externally validated in an independent cohort of 1,481 LQTS patients from Pavia, Italy. Results: In Rochester dataset, there were 77 endpoints in the phenotypic cohort during a median follow-up of 9.0 years, and 47 endpoints in the genotypic cohort during a median follow-up of 9.8 years. The time-dependent extension of Harrell's generalized C-statistics for the phenotypic model and genotypic model were 0.784 (95% CI: 0.740-0.827) and 0.785 (95% CI: 0.721-0.849), respectively, in the Rochester cohort. The C-statistics obtained from external validation in the Pavia cohort were 0.700 (95% CI: 0.610-0.790) and 0.711 (95% CI: 0.631-0.792) for the two models, respectively. Based on the above models, an online risk calculator estimating a 5-year risk of life-threatening arrhythmic events was developed. Conclusion: This study developed two risk prediction algorithms for phenotype and genotype positive LQTS patients separately. The estimated 5-year absolute risk can be used to quantify a LQTS patient's risk of developing life-threatening arrhythmic events and thus assisting in clinical decision making regarding prophylactic ICD therapy.

6.
Front Cardiovasc Med ; 9: 847259, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35355970

RESUMO

Background: Transcatheter heart valve (THV) selection for transcatheter aortic valve implantation (TAVI) is crucial to achieve procedural success. Borderline aortic annulus size (BAAS), which allows a choice between two consecutive valve sizes, is a common challenge during device selection. In the present study, we evaluated TAVI outcomes in patients with BAAS according to THV size selection. Methods: We performed a retrospective study including patients with severe aortic stenosis (AS) and BAAS, measured by multi-detector computed tomography (MDCT), undergoing TAVI with self-expandable (SE) or balloon-expandable (BE) THV from the Israeli multi-center TAVI registry. The aim was to evaluate outcomes of TAVI, mainly paravalvular leak (PVL) and valve hemodynamics, in patients with BAAS (based on MDCT) according to THV sizing selection in between 2 valve sizes. In addition, to investigate the benefit of shifting between different THV types (BE and SE) to avoid valve size selection in BAAS. Results: Out of 2,352 patients with MDCT measurements, 598 patients with BAAS as defined for at least one THV type were included in the study. In BAAS patients treated with SE-THV, larger THV selection was associated with lower rate of PVL, compared to smaller THV (45.3 vs. 64.5%; pv = 0.0038). Regarding BE-THV, larger valve selection was associated with lower post-procedural transvalvular gradients compared to smaller THV (mean gradient: 9.9 ± 3.7 vs. 12.5 ± 7.2 mmHg; p = 0.019). Of note, rates of mortality, left bundle branch block, permanent pacemaker implantation, stroke, annular rupture, and/or coronary occlusion did not differ between groups. Conclusion: BAAS is common among patients undergoing TAVI. Selection of a larger THV in these patients is associated with lower rates of PVL and optimized THV hemodynamics with no effect on procedural complications. Additionally, shift from borderline THV to non-borderline THV modified both THV hemodynamics and post-dilatation rates.

7.
Eur J Cardiothorac Surg ; 62(4)2022 09 02.
Artigo em Inglês | MEDLINE | ID: mdl-35244690

RESUMO

OBJECTIVES: The immunogenicity of two-dose severe acute respiratory syndrome coronavirus 2 vaccine is lower among heart transplant (HTx) recipients, compared with the general population. Our aim was to assess the immunogenicity of a third-dose vaccine in HTx recipients. METHODS: This is a prospective cohort study of HTx recipients who received a third dose of the BNT162b2 vaccine. Immunogenicity was assessed by serum levels of anti-spike immunoglobulin G (S-IgG), taken at baseline and 14-28 days after the third dose. Titres above 50 U/ml were interpreted positive. RESULTS: We Included 42 HTx recipients at a median age of 65 years [interquartile range (IQR) 58-70]. At baseline, the median of 27 days (IQR 13-42) before the third dose and the median titre of the whole group was 18 U/ml (IQR 4-130). Only 14 patients (33%) were S-IgG seropositive. After the third dose, the proportion of seropositive patients increased significantly to 57% (P = 0.05) and the median titre increased significantly to 633 U/ml (IQR 7-6104, P < 0.0001). Younger age at HTx (OR per 1-year decrease 1.07, P = 0.05), low tacrolimus serum level (OR per 1-unit decrease 2.28, P = 0.02), mammalian target of rapamycin use (OR 13.3, P = 0.003), lack of oral steroids use (OR 4.17, P = 0.04) and lack of calcineurin inhibitor use (71% of responders vs 100% non-responders received calcineurin inhibitors, P = 0.01) were predictors of seropositive result after the third dose. However, no significant association was detected following adjustment for baseline S-IgG titre. CONCLUSIONS: Third-dose booster of BNT162b2 vaccine significantly increased immunogenicity among HTx recipients who previously received a two-dose vaccine.


Assuntos
Vacinas contra COVID-19 , COVID-19 , Transplante de Coração , Imunização Secundária , Idoso , Vacina BNT162 , COVID-19/prevenção & controle , Inibidores de Calcineurina , Transplante de Coração/efeitos adversos , Humanos , Imunoglobulina G , Estudos Prospectivos , Serina-Treonina Quinases TOR , Tacrolimo , Transplantados , Vacinas Sintéticas , Vacinas de mRNA
8.
J Clin Med ; 12(1)2022 Dec 29.
Artigo em Inglês | MEDLINE | ID: mdl-36615064

RESUMO

Introduction: Atrial fibrillation (AF) recurrence following pulmonary vein isolation (PVI) ablation has clinical significance. Identifying risk factors for AF recurrence is important. We investigated serum albumin (SA) levels (g/dL) as a prognostic factor for the recurrence of AF following cryoballoon PVI ablation. Methods: We included patients who underwent cryoballoon PVI ablation at our institution between the years 2013 and 2018. The primary outcome was recurrence of AF during follow up. Results: Our cohort consisted of 126 patients (67% males, mean age 61.8 ± 10.0 years). The pattern of AF amongst the cohort was paroxysmal in 62.5%, persistent in 25.4%, and longstanding persistent in 6.3%. Those with lower SA levels had a mean AF duration significantly less than those with higher SA levels (2.81 years, 7.34 years, and 6.37 years for SA levels of <3.8, 3.8−4.1, and ≥4.1, respectively; p = 0.003). Patients with lower SA levels were significantly more likely to have had more previous cardioversions and a larger left atrial area and volume. The mean follow-up was 380 days, in which the AF recurrence rate was 20.6%. Patients with lower SA level had significantly more AF recurrences (47.4%, 16.7%, and 2.2% for SA levels of <3.8, 3.8−4.1, and ≥4.1, respectively; p < 0.001). Upon multivariate analysis, an SA level < 3.8 was associated with a higher risk of AF recurrence (OR = 5.422 95% CI 1.134; 25.910; p < 0.001). Conclusion: SA levels were found to be a strong independent marker for AF recurrence following PVI ablation.

9.
Am J Cardiol ; 159: 87-93, 2021 11 15.
Artigo em Inglês | MEDLINE | ID: mdl-34503821

RESUMO

The use of direct oral anticoagulants for stroke prevention in patients with non-valvular atrial fibrillation (NVAF) is robust. However, the efficacy and safety of different dosage in patients with renal dysfunction is still a clinical challenge. We aimed to evaluate the clinical characteristics and outcomes of patients treated with apixaban in its different doses. A multicenter prospective cohort study, where consecutive eligible apixaban or warfarin treated patients with NVAF and renal impairment, were registered. Patients were followed-up for clinical events over a mean period of 1 year. Analyses were performed according to the dose of apixaban given, with consideration to the standard indications for dose reduction. Primary outcome was a composite of 1-year mortality, stroke or systemic embolism, major bleeding and myocardial infarction, while secondary outcomes included those components separated. Among the study population (n = 2,140), risk of composite outcome was significantly lower in the high dose apixaban group (10%, n = 491) than the low dose group (18%, n = 673) and the warfarin group (18%, n = 976) p <0.001. Results of 1-year mortality were similar. Apixaban dosing analysis revealed 65% of patients were appropriately dosed, while 31% were under-dosed and 4% were over-dosed. Furthermore, 53% of patients treated with low dose apixaban were under-dosed. Propensity score analysis revealed that patients who were appropriately treated with low-dose apixaban had a trend towards better composite outcome and mortality than 1:1 matched warfarin treated patients (18% vs 24%, p = 0.09 and 16% vs 23%, p = 0.06, respectively). Overall, appropriately dosed apixaban treated patients at any dose had significantly better outcomes than matched warfarin treated patients (composite outcome probability of 13.1% vs 18.6%, p = 0.007). In conclusion, apixaban at any dose is a reasonable alternative to warfarin in patients with renal impairment, possibly associated with improved outcomes.


Assuntos
Anticoagulantes/administração & dosagem , Fibrilação Atrial/complicações , Inibidores do Fator Xa/administração & dosagem , Nefropatias/complicações , Pirazóis/administração & dosagem , Piridonas/administração & dosagem , Acidente Vascular Cerebral/prevenção & controle , Varfarina/administração & dosagem , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Israel , Masculino , Estudos Prospectivos , Sistema de Registros , Acidente Vascular Cerebral/etiologia
10.
Cardiology ; 146(5): 641-645, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34120112

RESUMO

INTRODUCTION: In patients with atrial fibrillation (AF) at risk for stroke, dabigatran 150 mg twice a day (DE150) is superior to warfarin for stroke prevention. However, there is paucity of data with respect to bleeding risk at this dose in elderly patients (≥75 years). We aimed to evaluate the safety of DE150 in comparison to warfarin in a real-world population with AF and low bleeding risk (HAS-BLED score ≤2). METHODS: In this prospective observational study, 754 consecutive patients with AF and HAS-BLED score ≤2 were included. We compared outcome of elderly patients (age ≥75 tears) to younger patients (age <75 years). The primary end point was the combined incidence of all-cause mortality, stroke, systemic emboli, and major bleeding event during a mean follow-up of 1 year. RESULTS: There were 230 (30%) elderly patients, 151 patients were treated with warfarin, and 79 were treated with DE150. Fifty-two patients experienced the primary endpoint during the 1-year follow-up. Among the elderly, at 1-year of follow-up, the cumulative event rate of the combined endpoint in the DE150 and warfarin was 8.9 and 15.9% respectively (p = 0.14). After adjustment for age and gender, patients who were treated with DE150 had a nonsignificant difference in the risk for the combined end point as patients treated with warfarin both among the elderly and among the younger population (HR 0.58, 95% C.I = 0.25-1.39 and HR = 1.12, 95% C.I 0.62-2.00, respectively [p for age-group-by-treatment interaction = 0.83). CONCLUSIONS: Our results suggest that Dabigatran 150 mg twice a day can be safely used among elderly AF patients with low bleeding risk.


Assuntos
Dabigatrana , Hemorragia , Idoso , Dabigatrana/efeitos adversos , Hemorragia/induzido quimicamente , Hemorragia/epidemiologia , Humanos
11.
Int J Cardiovasc Imaging ; 37(9): 2785-2790, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33909226

RESUMO

Epicardial and Pericardia fat have been hypothesized to exert local and systemic pathogenic effects on nearby cardiac structures. The present study aimed to evaluate the impact of epicardial and pericardial fat volumes on the outcome of patients that underwent a first pulmonary vein isolation (PVI) with cryoablation. We included 130 consecutive patients with atrial fibrillation (AF) that underwent contrast enhanced ECG-gated cardiac computed tomography (CCT) before a PVI. The control group included 50 patients in normal sinus rhythm that underwent ECG-gated CT to rule out coronary artery disease. Epicardial and pericardial fat volumes were quantified with CCT. Patients with AF compared to patients with normal sinus rhythm (control group) had significantly larger epicardial (140.3 ± 58.1 vs. 55.9 ± 17.7 ml; respectively, P < 0.001) and pericardial (77.0 ± 35.5 ml vs. 27.2 ± 9.5 ml; respectively, P < 0.001) fat volumes. Among patients that underwent PVIs, those with AF recurrence had a greater epicardial (175.0 ± 54.4 ml vs. 130.7 ± SD 54.2 ml; respectively, P < 0.001) and pericardial (93.7 ± SD 42.8 vs. 72.5 ± SD 31.9 ml; respectively, P < 0.001) fat volumes, compared to patients with no AF recurrence. Multivariate analyses revealed that epicardial fat was an independent predictor of recurrence post-ablation (HR = 1.08, 95% CI 1.02-1.16 per 10-ml increase in volume; P = 0.009). Pericardial fat was associated with 7% increase in risk of recurrent AF (HR = 1.07, 95% CI 0.98-1.18; P = 0.117). Epicardial fat, assessed with contrast enhanced CCT, is an independent predictor of AF recurrence after PVI ablation.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Humanos , Valor Preditivo dos Testes , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Recidiva , Tomografia Computadorizada por Raios X , Resultado do Tratamento
12.
PLoS One ; 16(3): e0248306, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33690718

RESUMO

BACKGROUND: The extent of myocardial fibrosis in patients with severe aortic stenosis might have an important prognostic value. Non-invasive imaging to quantify myocardial fibrosis by measuring extracellular volume fraction might have an important clinical utility prior to aortic valve intervention. METHODS: Seventy-five consecutive patients with severe aortic stenosis, and 19 normal subjects were prospectively recruited and underwent pre- and post-contrast computed tomography for estimating myocardial extracellular volume fraction. Serum level of galectin-3 was measured and 2-dimensional echocardiography was performed to characterize the extent of cardiac damage using a recently published aortic stenosis staging classification. RESULTS: Extracellular volume fraction was higher in patients with aortic stenosis compared to normal subjects (40.0±11% vs. 21.6±5.6%; respectively, p<0.001). In patients with aortic stenosis, extracellular volume fraction correlated with markers of left ventricular decompensation including New York Heart Association functional class, left atrial volume, staging classification of aortic stenosis and lower left ventricular ejection fraction. Out of 75 patients in the AS group, 49 underwent TAVI, 6 surgical AVR, 2 balloon valvuloplasty, and 18 did not undergo any type of intervention. At 12-months after aortic valve intervention, extracellular volume fraction predicted the combined outcomes of stroke and hospitalization for heart failure with an area under the curve of 0.77 (95% confidence interval: 0.65-0.88). A trend for correlation between serum galectin-3 and extracellular volume was noted. CONCLUSION: In patients with severe aortic stenosis undergoing computed tomography before aortic valve intervention, quantification of extracellular volume fraction correlated with functional status and markers of left ventricular decompensation, and predicted the 12-months composite adverse clinical outcomes. Implementation of this novel technique might aid in the risk stratification process before aortic valve interventions.


Assuntos
Estenose da Valva Aórtica/diagnóstico por imagem , Ventrículos do Coração/diagnóstico por imagem , Miocárdio , Tomografia Computadorizada por Raios X , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/sangue , Proteínas Sanguíneas , Feminino , Fibrose , Galectinas/sangue , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Índice de Gravidade de Doença
13.
Am J Cardiol ; 141: 72-78, 2021 02 15.
Artigo em Inglês | MEDLINE | ID: mdl-33217350

RESUMO

Transcatheter aortic-valve implantation (TAVI) is an established treatment option in patients with severe symptomatic aortic stenosis. Intermediate and long-term follow up data of these patients is limited. Data was taken from a large all-comer single center prospective registry (2008 to 2019). The primary end point was all-cause mortality. The secondary endpoints were long-term valve hemodynamic performance; paravalvular leak (PVL) at 5-year follow-up. We also report on temporal trends in this cohort. Our cohort included 998 patients with a mean age of 82.3 ± 7.2 years and 52.2% females. TAVI was performed via the transfemoral, trans-apical, subclavian and other access routes in 93.9%, 3.6%, 2.5%, and 0.6% of patients, respectively. A self-expandable device was used in 69.4% of cases, balloon expandable device in 28.1% and in 2.5% other devices. The cumulative risk for all-cause mortality at 5 years was 43.4% (95% CI 39.1 to 47.7). The immediate and long-term valve gradients were low and maintained. On durability analysis at 5 years, severe structural valve deterioration was present in 1.6% of cases. At 5-year follow-up, PVL was moderate in 3.3% and no patients has severe PVL. On temporal trends analysis, we found that the procedural aspects of TAVI improved over time with lower rates of significant PVL and significantly lower procedural mortality. In conclusion, TAVI patients have a favorable long-term outcome, with excellent valve hemodynamic parameters and good clinical outcomes. Over time and with increasing experience, procedural and patient outcomes have improved.


Assuntos
Estenose da Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas , Mortalidade , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Idoso de 80 Anos ou mais , Valvopatia Aórtica/epidemiologia , Causas de Morte , Feminino , Hemodinâmica , Humanos , Estudos Longitudinais , Masculino , Complicações Pós-Operatórias/epidemiologia , Falha de Prótese , Sistema de Registros
14.
J Cardiovasc Comput Tomogr ; 15(4): 339-347, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33153946

RESUMO

BACKGROUND: Distinct anatomical features predispose bicuspid AS patients to conduction disturbances after TAVR. This study sought to evaluate whether the incidence of permanent pacemaker implantation (PPMI) and left bundle branch block (LBBB) in patients with bicuspid aortic stenosis (AS) following transcatheter aortic valve replacement (TAVR) is related to an anatomical association between bicuspid AS and short membranous septal (MS) length. METHODS: Sixty-seven consecutive patients with bicuspid AS from a Bicuspid AS TAVR multicenter registry and 67 propensity-matched patients with tricuspid AS underwent computed tomography before TAVR. RESULTS: MS length was significantly shorter in bicuspid AS compared with tricuspid AS (6.2 ± 2.5 mm vs. 8.4 ± 2.7 mm, respectively; p < 0.001). In patients with bicuspid AS, MS length and aortic valve calcification were the most powerful pre-procedural independent predictors of PPMI or LBBB (odds ratio [OR]: 1.38, 95% confidence interval [CI]: 1.15 to 1.55, p = 0.003 and OR: 1.92, 95% CI: 1.1 to 3.34, p = 0.022, respectively). When taking into account pre- and post-procedural parameters, aortic valve calcification and the difference between MS length and implantation depth were the most powerful independent predictors of PPMI or LBBB in patients with bicuspid AS (OR: 1.82, 95%: 1.1 to 3.1, p = 0.027; OR: 1.25, 95% CI: 1.10 to 1.38, p = 0.003). CONCLUSION: MS length, which was significantly shorter in bicuspid AS compared with tricuspid AS, aortic valve calcification, and device implantation deeper than MS length predict PPMI or LBBB in bicuspid AS after TAVR.


Assuntos
Estenose da Valva Aórtica , Doença da Válvula Aórtica Bicúspide , Próteses Valvulares Cardíacas , Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estimulação Cardíaca Artificial , Constrição Patológica , Humanos , Valor Preditivo dos Testes , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
15.
Circ Arrhythm Electrophysiol ; 13(9): e008499, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32701367
17.
Catheter Cardiovasc Interv ; 96(7): E695-E702, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32022390

RESUMO

BACKGROUND: Transcatheter aortic valve implantation (TAVI) for aortic stenosis (AS) risk assessment is still developing and mostly concerned with mortality in the periprocedural period. We therefore sought to develop and then validate a score to predict 1-year adverse outcome. METHODS: Patients that underwent TAVI for severe AS in the Israeli registry. Patients with unsuccessful/suboptimal implantation were excluded. The cohort was split to derivation/validation cohorts by a ratio of 70:30. The outcome was defined as 1-year composite of mortality, stroke, and no improvement in NYHA class (vs. baseline). Logistic regression was used to fit the prediction model. RESULTS: Out of 2,440 patients meeting inclusion criteria, 276 were excluded, leaving 2,160 patients for both cohorts. At 1 year, 299 (14%) patients experienced the adverse ("futile") outcome. The derived prediction model included mean aortic valve (AV) gradient, previous pacemaker, previous oncological disease, need for diuretics, baseline NYHA class, hemoglobin and creatinine levels, and nonfemoral access site. The model's area under the curve (AUC) was 0.69 in the derivation and 0.70 in the validation cohort. Performance of other scores in the validation cohort were lower (0.60 for STS, 0.55 for Euroscore2, 0.56 for TVT score, and 0.53 for TAVI2-score, p = .03). Based on three risk tiers, patients had a low risk (20/306, 7% futility), a medium risk (50/304, 17%), and high risk (18/37, 49%) for futility. CONCLUSIONS: The TAVI futility risk model can be used to provide further insight regarding prediction measures and/or patients' outcomes outside of the periprocedural period (NCT02023060).


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Regras de Decisão Clínica , Futilidade Médica , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Feminino , Hemodinâmica , Humanos , Israel , Masculino , Valor Preditivo dos Testes , Sistema de Registros , Reprodutibilidade dos Testes , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/mortalidade , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
18.
Int J Cardiol ; 304: 23-28, 2020 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-32008849

RESUMO

AIMS: We aimed to validate a new scoring system based on extent of cardiac damage for risk stratification in patients undergoing transcatheter aortic valve replacement (TAVR) in a real-world cohort and to examine the addition of baseline albumin in risk assessment. METHODS AND RESULTS: We investigated 2608 patients undergoing TAVR. Subjects were divided into five groups based on their echocardiography findings. Patients were further assessed by incorporating baseline albumin. Multivariable analysis demonstrated that each increase in stage was associated with significant increased risk of 1-year mortality (HR 1.37, 95%CI 1.23-1.54, p < .001). Among patients at increased stage (3-4), incorporation of baseline of albumin identified the highest risk group, such that each 1 decrement in albumin levels was associated with more than triple increase in mortality among patients at stage 3 and 4 (HR 2.77, 95% CI 1.48-5.18, p-value = .001). CONCLUSIONS: Cardiac damage classification is validated in a real-world cohort of patients undergoing TAVR. Incorporation of low baseline albumin may further identify patients at the highest risk group. CONDENSTED ABSTRACT: We evaluated 2608 patients undergoing transcatheter aortic valve replacement (TAVR) in order to validate a new scoring system dividing patients in to 5 stages (0-4) based on extent of cardiac damage. Patients were further assessed by incorporating baseline albumin. Multivariable analysis demonstrated that each increase in stage was associated with significant increased risk of 1-year mortality. Furthermore, among patients at increased stage (3-4), incorporation of baseline of albumin identified the highest risk group, such that each 1 decrement in albumin levels was associated with more than triple increase in mortality among patients at stage 3 and 4.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Albuminas , Valva Aórtica , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Humanos , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Resultado do Tratamento
19.
J Interv Card Electrophysiol ; 58(1): 113-118, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-31227978

RESUMO

BACKGROUND: Cardiovascular implantable electronic device (CIED) replacement is increasingly common. It has been proposed that capsule removal at the time of CIED replacement may reduce infection rates. In this study, we aimed to assess how pocket capsule removal impacted infection rates in patients undergoing CIED replacement. METHODS: We retrospectively reviewed the medical records of patients who underwent CIED replacement from 2006 to 2016 at a single centre. We retrieved patient data, procedure details, and clinical outcomes. To evaluate the relationship between capsule removal and CIED infection, we used the Cox proportional hazard model, with adjustment for multiple variables. RESULTS: During the study period, 773 patients underwent device replacement. Of these patients, 194 (25%) underwent capsule debridement during the replacement procedure. The mean patient age was 75 ± 15 years, and 281 (36.3%) were females. The replaced CIEDs included DDD pacemakers (32%), VDD pacemakers (15%), VVI/AAI pacemakers (13%), defibrillators (22%), and cardiac resynchronization therapy devices (CRT-D/P) (17%). During an average follow-up of 3.6 years, 42 (5%) patients experienced a CIED infection. Multivariate analysis revealed that patients who underwent capsule removal had a significantly lower risk of CIED infection, with a hazard ratio of 0.32 (95% confidence interval, 0.12-0.83; P = 0.019). CONCLUSIONS: Capsule debridement during CIED replacement was associated with a significant reduction of CIED infection risk. There is a need for randomized controlled studies to confirm these findings.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Infecções Relacionadas à Prótese , Desbridamento , Desfibriladores Implantáveis/efeitos adversos , Remoção de Dispositivo , Eletrônica , Feminino , Humanos , Recém-Nascido , Marca-Passo Artificial/efeitos adversos , Infecções Relacionadas à Prótese/epidemiologia , Estudos Retrospectivos , Fatores de Risco
20.
Isr Med Assoc J ; 21(12): 817-822, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31814346

RESUMO

BACKGROUND: Current guidelines for choosing between revascularization modalities may not be appropriate for young patients. OBJECTIVES: To compare outcomes and guide treatment options for patients < 40 years of age, who underwent percutaneous coronary intervention (PCI) or coronary artery bypass grafting (CABG) between 2008 and 2018. METHODS: Outcomes were compared for 183 consecutive patients aged < 40 years who underwent PCI or CABG between 2008 and 2018, Outcomes were compared as time to first event and as cumulative events for non-fatal outcomes. RESULTS: Mean patient age was 36.3 years and 96% were male. Risk factors were similar for both groups. Drug eluting stents were implemented in 71% of PCI patients and total arterial revascularization in 74% of CABG patients. During a median follow-up of 6.5 years, 16 patients (8.6%) died. First cardiovascular events occurred in 35 (38.8%) of the PCI group vs. 29 (31.1%) of the CABG group (log rank P = 0.022), repeat events occurred in 96 vs. 51 (P < 0.01), respectively. After multivariate adjustment, CABG was associated with a significantly reduced risk for first adverse event (hazard ratio [HR] 0.305, P < 0.01) caused by a reduction in repeat revascularization. CABG was also associated with a reduction in overall repeat events (HR 0.293, P < 0.01). There was no difference in overall mortality between CABG and PCI. CONCLUSIONS: Young patients with coronary disease treated by CABG showed a reduction in the risk for non-fatal cardiac events. Mortality was similar with CABG and PCI.


Assuntos
Ponte de Artéria Coronária , Doença da Artéria Coronariana , Stents Farmacológicos , Efeitos Adversos de Longa Duração , Intervenção Coronária Percutânea , Reoperação , Adulto , Fatores Etários , Pesquisa Comparativa da Efetividade , Ponte de Artéria Coronária/efeitos adversos , Ponte de Artéria Coronária/métodos , Ponte de Artéria Coronária/mortalidade , Doença da Artéria Coronariana/mortalidade , Doença da Artéria Coronariana/cirurgia , Feminino , Humanos , Israel/epidemiologia , Efeitos Adversos de Longa Duração/diagnóstico , Efeitos Adversos de Longa Duração/etiologia , Efeitos Adversos de Longa Duração/mortalidade , Efeitos Adversos de Longa Duração/cirurgia , Masculino , Mortalidade , Avaliação de Processos e Resultados em Cuidados de Saúde , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/instrumentação , Intervenção Coronária Percutânea/métodos , Intervenção Coronária Percutânea/mortalidade , Reoperação/métodos , Reoperação/estatística & dados numéricos , Fatores de Risco , Fatores Sexuais
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...