Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Ultrasound Med ; 29(4): 633-8, 2010 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-20375382

RESUMO

OBJECTIVE: The purpose of this series was to report the contribution of 3-dimensional ultrasonographic (3DUS) technologies in performing the prenatal diagnosis of main stem bronchial atresia (BA). METHODS: We report 2 cases in which the prenatal diagnosis of main stem BA was performed using 3DUS technologies. Both fetuses presented with extremely enlarged hyperechoic right lungs, shifting the mediastinum to the left, associated with hydrops and polyhydramnios. A revision of the literature was made, focusing on the prenatal characteristics and perinatal prognosis of main stem BA. RESULTS: In the first case, a congenital type III cystic adenomatoid malformation was suspected initially, but a posterior 3DUS analysis on multiplanar imaging allowed identification of a dilated right bronchus, and a right main stem BA was confirmed at autopsy. In the second case, volume contrast imaging was used during fetal scanning, which also allowed identification of the right main bronchial dilatation. In reviewing the literature, we found a tendency for main stem BA to be more severe than lobar and segmental atresias. CONCLUSIONS: Three-dimensional ultrasonographic technologies may improve the pre-natal diagnosis of main stem BA.


Assuntos
Brônquios/anormalidades , Anormalidades do Sistema Respiratório/diagnóstico por imagem , Ultrassonografia Doppler/métodos , Ultrassonografia Pré-Natal/métodos , Adulto , Feminino , Humanos , Imageamento Tridimensional , Gravidez , Resultado da Gravidez
2.
J Obstet Gynaecol Res ; 35(6): 1031-41, 2009 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-20144168

RESUMO

AIM: To evaluate the potential of different lung measurements using three-dimensional ultrasonography (3D-US) to predict perinatal outcome in isolated congenital diaphragmatic hernia (CDH). METHODS: Twenty-one fetuses presenting isolated CDH were prospectively evaluated by 3D-US between January 2002 and November 2003. Observed/expected total, contralateral and ipsilateral fetal lung volume ratios (o/e-TotFLV, o/e-ContFLV and o/e-IpsiFLV, respectively) were calculated using the rotational technique and ultrasonographic fetal total lung volume to bodyweight ratio (USFLW). These lung measurements were compared to each other and to perinatal outcomes: perinatal deaths, severe pulmonary hypoplasia (PH) and pulmonary arterial hypertension (PAH). RESULTS: Perinatal death occurred in 11 of the 21 infants (52.4%), severe PH in 14 of 21 infants (66.7%) and PAH in 14 of 20 neonates (70%). Severe PH and PAH occurred simultaneously in 12 of 20 (60%) infants. Good correlations between lung ratios were observed. O/e-TotFLV, o/e-IpsiFLV and USFLW correlated statistically with postnatal diagnosis of severe PH, while only o/e-TotFLH correlated statistically with postnatal diagnosis of PAH. The accuracies of o/e-TotFLV, o/e-ContFLV, o/e-IpsiFLV and USFLW in predicting perinatal deaths were 85.7, 76.2, 66.7 and 76.2%, respectively. CONCLUSION: O/e-TotFLV using 3D-US appears to be the most accurate predictor of perinatal mortality because it can predict both PH and PAH.


Assuntos
Doenças Fetais/diagnóstico por imagem , Hérnia Diafragmática/diagnóstico por imagem , Pulmão/diagnóstico por imagem , Pulmão/embriologia , Diagnóstico Pré-Natal/métodos , Feminino , Feto , Hérnias Diafragmáticas Congênitas , Humanos , Recém-Nascido , Gravidez , Estudos Prospectivos , Ultrassonografia
3.
Fetal Diagn Ther ; 24(4): 389-94, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18957853

RESUMO

OBJECTIVE: To evaluate the precision of three-dimensional ultrasonography (3DUS) in estimating the ipsilateral lung volume and the potential of this measurement to predict neonatal death in congenital diaphragmatic hernia (CDH). METHODS: Between January 2002 and December 2004, the ipsilateral lung volumes were assessed by 3DUS using the technique of rotation of the multiplan imaging in 39 fetuses with CDH. The observed/expected ipsilateral lung volume ratios (o/e-IpsiFLVR) were compared to the lung/head ratios (LHR) and to the observed/expected total fetal lung volume ratios (o/e-TotFLVR) as well as to postnatal death. RESULTS: Ipsilateral lung volumes (median 0.12, range 0.01-0.66) were more reduced than the total lung volumes (median 0.52, range 0.11-0.95, p < 0.001) in CDH. The bias and precision of 3DUS in estimating ipsilateral lung volumes were -0.61 and 0.99 cm(3), respectively, with absolute limits of agreement from -2.56 to +1.33 cm(3). The o/e-IpsiFLVR was lower in neonatal death cases (median 0.09, range 0.01-0.46) than in survivals (median 0.18, range 0.01-0.66), but this difference was not statistically significance (p > 0.05). The sensitivity, specificity, (positive and negative) predictive values and accuracy of o/e-IpsiFLVR in predicting neonatal death was 52.6% (10/19), 83.3% (10/12), 83.3% (10/12), 52.6% (10/19) and 64.5% (20/31), respectively. CONCLUSION: Although the ipsilateral lung volume can be measured by 3DUS, it cannot be used to predict neonatal death when considering it alone. However, it is important to measure it to calculate the total fetal lung volumes as the o/e-TotFLVR has the best efficacy in predicting neonatal death in isolated CDH.


Assuntos
Hérnia Diafragmática/diagnóstico por imagem , Imageamento Tridimensional , Medidas de Volume Pulmonar/métodos , Ultrassonografia Pré-Natal/métodos , Ultrassonografia Pré-Natal/normas , Feminino , Idade Gestacional , Hérnia Diafragmática/mortalidade , Hérnias Diafragmáticas Congênitas , Humanos , Recém-Nascido , Doenças do Recém-Nascido/mortalidade , Medidas de Volume Pulmonar/instrumentação , Valor Preditivo dos Testes , Gravidez , Análise de Regressão , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
4.
J Pediatr Surg ; 43(4): 606-11, 2008 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-18405704

RESUMO

OBJECTIVE: The aim of the study was to evaluate the potential of fetal pulmonary artery (PA) diameters to predict perinatal death and pulmonary arterial hypertension (PAH) in congenital diaphragmatic hernia (CDH). STUDY DESIGN: In this prospective observational study, observed PA (main, right, and left) diameters were measured at the level of the 3 vessels in 21 fetuses with isolated CDH and in 85 controls at 22 to 36 weeks. The observed/expected (o/e) diameters of the main, contralateral, and ipsilateral PAs were calculated by comparing these measurements with reference values obtained in our previous study and correlated with perinatal death and postnatal PAH. RESULTS: The o/e PA diameters were significantly reduced in fetuses with CDH compared to controls (P < .001) and in fetuses with CDH who died (P < .050). However, there was no significant association between PA diameters and PAH (P >or= .050). CONCLUSIONS: The PA diameters might be useful to predict perinatal death in isolated CDH but not postnatal PAH, suggesting that PA diameters are probably related to the severity of pulmonary hypoplasia.


Assuntos
Hérnia Diafragmática/diagnóstico , Hérnias Diafragmáticas Congênitas , Hipertensão Pulmonar/diagnóstico , Artéria Pulmonar/diagnóstico por imagem , Artéria Pulmonar/embriologia , Hérnia Diafragmática/complicações , Humanos , Hipertensão Pulmonar/etiologia , Estudos Prospectivos , Ultrassonografia Pré-Natal , Pesos e Medidas
5.
J Clin Ultrasound ; 36(5): 273-8, 2008 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-18067125

RESUMO

PURPOSE: To use 3-dimensional sonography (3DUS) to measure contralateral lung volume and evaluate the potential of this measurement to predict neonatal outcome in isolated congenital diaphragmatic hernia (CDH). METHODS: Between January 2002 and December 2004, the contralateral lung volumes of 39 fetuses with isolated CDH were measured via 3DUS using rotational multiplanar imaging. The observed/expected contralateral fetal lung volume ratios (o/e-ContFLVR) were compared with the lung/head ratio (LHR), observed/expected total fetal lung volume ratio (o/e-TotFLVR), and postnatal outcome. RESULTS: Contralateral lung volumes are less reduced than total lung volumes in CDH. The bias and precision of 3DUS in estimating contralateral lung volumes were 0.99 cm(3) and 1.11 cm(3), respectively, with absolute limits of agreement ranging from -1.19 cm(3) to +3.17 cm(3). The o/e-ContFLVR was significantly lower in neonatal death cases (median, 0.49 cm(3); range, 0.22-0.99 cm(3)) than in survival cases (median, 0.58 cm(3); range, 0.42-0.92 cm(3) [p < 0.01]). Overall accuracy of the o/e-ContFLVR, o/e-TotFLVR, and LHR in predicting neonatal death were 67.7% (21/31), 80.7% (25/31), and 77.4% (24/31), respectively. CONCLUSION: Although o/e-ContFLVR can be precisely measured with 3DUS and can be used to predict neonatal death in CDH, it is less accurate than LHR and o/e-TotFLVR for that purpose.


Assuntos
Doenças Fetais/diagnóstico por imagem , Hérnia Diafragmática/diagnóstico por imagem , Imageamento Tridimensional/métodos , Medidas de Volume Pulmonar/métodos , Pulmão/diagnóstico por imagem , Ultrassonografia Pré-Natal/métodos , Diagnóstico Diferencial , Feminino , Hérnia Diafragmática/embriologia , Hérnias Diafragmáticas Congênitas , Humanos , Pulmão/embriologia , Pulmão/fisiopatologia , Gravidez , Reprodutibilidade dos Testes , Estudos Retrospectivos
6.
Am J Obstet Gynecol ; 195(6): 1720-8, 2006 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-16769020

RESUMO

OBJECTIVE: The purpose of this study was to evaluate the potential of 3-dimensional (3D) power Doppler imaging to predict neonatal outcome and pulmonary arterial hypertension (PAH) in congenital diaphragmatic hernia (CDH). STUDY DESIGN: In this prospective observational study, 3D-power Doppler ultrasonography was performed in 21 cases with isolated CDH between 23 and 33 weeks of gestation and in 58 controls between 20 and 40 weeks. Using the same preestablished settings for all cases, power Doppler was applied to each lung, and fetal lung volumes (FLV) were estimated using the rotational technique. The 3D power Doppler histogram was used to determine the vascular indices, which were plotted against gestational age and compared with neonatal outcome, PAH, gestational age, and FLV. RESULTS: Fetal pulmonary vascular indices showed a constant distribution throughout gestation, being significantly lower in cases with CDH than in controls (P < .001). Among CDH cases, the vascular indices were significantly lower in fetuses who died (P < .05), and in fetuses with neonatal PAH (P < .05). The severity of neonatal PAH was also associated with a progressive reduction in prenatal vascular indices (P < .05). All vascular indices correlated with o/e-FLV, but not with gestational age. CONCLUSION: All vascular indices seem to be constant throughout gestation. In isolated CDH, perinatal outcome and postnatal PAH can be predicted using the vascular indices assessed by 3D power Doppler histogram.


Assuntos
Feto/irrigação sanguínea , Hérnia Diafragmática/diagnóstico por imagem , Imageamento Tridimensional , Pulmão/embriologia , Ultrassonografia Doppler , Ultrassonografia Pré-Natal , Vasos Sanguíneos/diagnóstico por imagem , Feminino , Morte Fetal , Idade Gestacional , Cabeça/diagnóstico por imagem , Hérnia Diafragmática/complicações , Hérnias Diafragmáticas Congênitas , Humanos , Hipertensão Pulmonar/etiologia , Hipertensão Pulmonar/mortalidade , Hipertensão Pulmonar/fisiopatologia , Recém-Nascido , Pulmão/diagnóstico por imagem , Pulmão/fisiopatologia , Medidas de Volume Pulmonar , Valor Preditivo dos Testes , Gravidez , Estudos Prospectivos , Índice de Gravidade de Doença
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA