Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 27
Filtrar
1.
Bone ; 179: 116978, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-37993038

RESUMO

Almost all prior mouse fracture healing models have used needles or K-wires for fixation, unwittingly providing inadequate mechanical stability during the healing process. Our contention is that the reported outcomes have predominantly reflected this instability, rather than the impact of diverse biological conditions, pharmacologic interventions, exogenous growth factors, or genetic considerations. This important issue becomes obvious upon a critical review of the literature. Therefore, the primary aim of this study was to demonstrate the significance of mouse-specific implants designed to provide both axial and torsional stability (Screw and IM Nail) compared to conventional pins (Needle and K-wires), even when used in mice with differently sized marrow canals and diverse genetic backgrounds. B6 (large medullary canal), DBA, and C3H (smaller medullary canals) mice were employed, all of which have different bone morphologies. Closed femoral fractures were created and stabilized with intramedullary implants that provide different mechanical conditions during the healing process. The most important finding of this study was that appropriately designed mouse-specific implants, providing both axial and torsional stability, had the greatest influence on bone healing outcomes regardless of the different bone morphologies encountered. For instance, unstable implants in the B6 strain (largest medullary canal) resulted in significantly greater callus, with a fracture region mainly comprising trabecular bone along with the presence of cartilage 28 days after surgery. The DBA and C3H strains (with smaller medullary canals) instead formed significantly less callus, and only had a small amount of intracortical trabeculation remaining. Moreover, with more stable fracture fixation a higher BV/TV was observed and cortices were largely restored to their original dimensions and structure, indicating an accelerated healing and remodeling process. These observations reveal that the diaphyseal cortical thickness, influenced by the genetic background of each strain, played a pivotal role in determining the amount of bone formation in response to the fracture. These findings are highly important, indicating the rate and type of tissue formed is a direct result of mechanical instability, and this most likely would mask the true contribution of the tested genes, genetic backgrounds, or various therapeutic agents administered during the bone healing process.


Assuntos
Fraturas do Fêmur , Fixação Intramedular de Fraturas , Camundongos , Animais , Consolidação da Fratura/fisiologia , Camundongos Endogâmicos DBA , Camundongos Endogâmicos C3H , Fraturas do Fêmur/cirurgia , Calo Ósseo
2.
Artif Organs ; 47(10): 1581-1591, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37395735

RESUMO

BACKGROUND: Extracorporeal life support (ECLS) has extensive applications in managing patients with acute cardiac and pulmonary failure. Two primary modalities of ECLS, cardiopulmonary bypass (CPB) and extracorporeal membrane oxygenation (ECMO), include several similarities in their composition, complications, and patient outcomes. Both CPB and ECMO pose a high risk of thrombus formation and platelet activation due to the large surface area of the devices and bleeding due to system anticoagulation. Therefore, novel methods of anticoagulation are needed to reduce the morbidity and mortality associated with extracorporeal support. Nitric oxide (NO) has potent antiplatelet properties and presents a promising alternative or addition to anticoagulation with heparin during extracorporeal support. METHODS: We developed two ex vivo models of CPB and ECMO to investigate NO effects on anticoagulation and inflammation in these systems. RESULTS: Sole addition of NO as an anticoagulant was not successful in preventing thrombus formation in the ex vivo setups, therefore a combination of low-level heparin with NO was used. Antiplatelet effects were observed in the ex vivo ECMO model when NO was delivered at 80 ppm. Platelet count was preserved after 480 min when NO was delivered at 30 ppm. CONCLUSION: Combined delivery of NO and heparin did not improve haemocompatibility in either ex vivo model of CPB and ECMO. Anti-inflammatory effects of NO in ECMO systems have to be evaluated further.


Assuntos
Oxigenação por Membrana Extracorpórea , Trombose , Humanos , Oxigenação por Membrana Extracorpórea/efeitos adversos , Oxigenação por Membrana Extracorpórea/métodos , Óxido Nítrico/uso terapêutico , Ponte Cardiopulmonar/efeitos adversos , Ponte Cardiopulmonar/métodos , Anticoagulantes/farmacologia , Anticoagulantes/uso terapêutico , Heparina/farmacologia , Heparina/uso terapêutico , Trombose/etiologia , Trombose/prevenção & controle , Inflamação/etiologia , Inflamação/prevenção & controle
3.
J Heart Lung Transplant ; 42(8): 1015-1029, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37031869

RESUMO

BACKGROUND: The global shortage of donor hearts available for transplantation is a major problem for the treatment of end-stage heart failure. The ischemic time for donor hearts using traditional preservation by standard static cold storage (SCS) is limited to approximately 4 hours, beyond which the risk for primary graft dysfunction (PGD) significantly increases. Hypothermic machine perfusion (HMP) of donor hearts has been proposed to safely extend ischemic time without increasing the risk of PGD. METHODS: Using our sheep model of 24 hours brain death (BD) followed by orthotopic heart transplantation (HTx), we examined post-transplant outcomes in recipients following donor heart preservation by HMP for 8 hours, compared to donor heart preservation for 2 hours by either SCS or HMP. RESULTS: Following HTx, all HMP recipients (both 2 hours and 8 hours groups) survived to the end of the study (6 hours after transplantation and successful weaning from cardiopulmonary bypass), required less vasoactive support for hemodynamic stability, and exhibited superior metabolic, fluid status and inflammatory profiles compared to SCS recipients. Contractile function and cardiac damage (troponin I release and histological assessment) was comparable between groups. CONCLUSIONS: Overall, compared to current clinical SCS, recipient outcomes following transplantation are not adversely impacted by extending HMP to 8 hours. These results have important implications for clinical transplantation where longer ischemic times may be required (e.g., complex surgical cases, transport across long distances). Additionally, HMP may allow safe preservation of "marginal" donor hearts that are more susceptible to myocardial injury and facilitate increased utilization of these hearts for transplantation.


Assuntos
Transplante de Coração , Animais , Ovinos , Humanos , Preservação de Órgãos/métodos , Doadores de Tecidos , Perfusão/métodos , Coração
4.
Artif Organs ; 47(7): 1122-1132, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36932963

RESUMO

OBJECTIVE: Pulsatile-flow veno-arterial extracorporeal membrane oxygenation (V-A ECMO) has shown encouraging results for microcirculation resuscitation and left ventricle unloading in patients with refractory cardiogenic shock. We aimed to comprehensively assess different V-A ECMO parameters and their contribution to hemodynamic energy production and transfer through the device circuit. METHODS: We used the i-cor® ECMO circuit, which composed of Deltastream DP3 diagonal pump and i-cor® console (Xenios AG), the Hilite 7000 membrane oxygenator (Xenios AG), venous and arterial tubing and a 1 L soft venous pseudo-patient reservoir. Four different arterial cannulae (Biomedicus 15 and 17 Fr, Maquet 15 and 17 Fr) were used. For each cannula, 192 different pulsatile modes were investigated by adjusting flow rate, systole/diastole ratio, pulsatile amplitudes and frequency, yielding 784 unique conditions. A dSpace data acquisition system was used to collect flow and pressure data. RESULTS: Increasing flow rates and pulsatile amplitudes were associated with significantly higher hemodynamic energy production (both p < 0.001), while no significant associations were seen while adjusting systole-to-diastole ratio (p = 0.73) or pulsing frequency (p = 0.99). Arterial cannula represents the highest resistance to hemodynamic energy transfer with 32%-59% of total hemodynamic energy generated being lost within, depending on pulsatile flow settings used. CONCLUSIONS: Herein, we presented the first study to compare hemodynamic energy production with all pulsatile ECLS pump settings and their combinations and widely used yet previously unexamined four different arterial ECMO cannula. Only increased flow rate and amplitude increase hemodynamic energy production as single factors, whilst other factors are relevant when combined.


Assuntos
Oxigenação por Membrana Extracorpórea , Humanos , Cânula , Modelos Cardiovasculares , Desenho de Equipamento , Oxigenadores de Membrana , Hemodinâmica , Fluxo Pulsátil
5.
Sci Rep ; 13(1): 4002, 2023 03 10.
Artigo em Inglês | MEDLINE | ID: mdl-36899029

RESUMO

Differential hypoxaemia (DH) is common in patients supported by femoral veno-arterial extracorporeal membrane oxygenation (V-A ECMO) and can cause cerebral hypoxaemia. To date, no models have studied the direct impact of flow on cerebral damage. We investigated the impact of V-A ECMO flow on brain injury in an ovine model of DH. After inducing severe cardiorespiratory failure and providing ECMO support, we randomised six sheep into two groups: low flow (LF) in which ECMO was set at 2.5 L min-1 ensuring that the brain was entirely perfused by the native heart and lungs, and high flow (HF) in which ECMO was set at 4.5 L min-1 ensuring that the brain was at least partially perfused by ECMO. We used invasive (oxygenation tension-PbTO2, and cerebral microdialysis) and non-invasive (near infrared spectroscopy-NIRS) neuromonitoring, and euthanised animals after five hours for histological analysis. Cerebral oxygenation was significantly improved in the HF group as shown by higher PbTO2 levels (+ 215% vs - 58%, p = 0.043) and NIRS (67 ± 5% vs 49 ± 4%, p = 0.003). The HF group showed significantly less severe brain injury than the LF group in terms of neuronal shrinkage, congestion and perivascular oedema (p < 0.0001). Cerebral microdialysis values in the LF group all reached the pathological thresholds, even though no statistical difference was found between the two groups. Differential hypoxaemia can lead to cerebral damage after only a few hours and mandates a thorough neuromonitoring of patients. An increase in ECMO flow was an effective strategy to reduce such damages.


Assuntos
Lesões Encefálicas , Oxigenação por Membrana Extracorpórea , Animais , Lesões Encefálicas/complicações , Oxigenação por Membrana Extracorpórea/efeitos adversos , Hipóxia/complicações , Modelos Teóricos , Ovinos , Choque Cardiogênico/etiologia
6.
J Heart Lung Transplant ; 41(8): 1032-1043, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35641425

RESUMO

BACKGROUND: Ventricular assist device (VAD) driveline exit site infection is a common complication. 3D scaffolds manufactured with highly homogeneous pores via melt electro-writing (MEW) may generate an improved skin-driveline interface which permits cellular in-growth and creates a barrier to prevent bacterial migration along the driveline tissue tunnel. This study investigated skin integration on segments of Heartmate 3 driveline: smooth polyurethane, velour, and on a custom MEW scaffold in a small animal model. METHODS: Drivelines with surfaces consisting of smooth polyurethane, velour bonded to smooth polyurethane, and smooth polyurethane with a MEW scaffold sleeve were implanted percutaneously in the dorsum of 42 rats. Each rat was implanted with 2 pieces of driveline of 2 cm in length. Skin integration was assessed after 7 and 14 days. RESULTS: Macroscopically, velour and MEW scaffold surfaces were anchored at the driveline-skin interface while smooth polyurethane samples were not attached. The histology analyses showed epidermal migration throughout the thickness of the velour and MEW scaffold groups. Evident tissue growth around single MEW scaffold fibers resulted in full coverage of the pores, while areas of compacted fibers were apparent in the velour group. Tissue ingrowth was significantly higher in the MEW group compared to the velour group after 7 (p < 0.0001) and 14 days (p < 0.0001). Marsupialization was observed in the smooth polyurethane samples. Mechanical pull-out forces were similar between velour and MEW scaffold groups at 7 and 14 days (p > 0.05). CONCLUSIONS: Velour and MEW scaffolds promoted epidermal integration while smooth polyurethane drivelines did not. Fine control of MEW scaffold structure production resulted in full cellular coverage and may reduce driveline infection.


Assuntos
Coração Auxiliar , Infecções Relacionadas à Prótese , Animais , Coração Auxiliar/efeitos adversos , Poliuretanos , Infecções Relacionadas à Prótese/etiologia , Ratos
7.
Acta Biomater ; 138: 92-111, 2022 01 15.
Artigo em Inglês | MEDLINE | ID: mdl-34781026

RESUMO

Current clinical treatment strategies for the bypassing of small diameter (<6 mm) blood vessels in the management of cardiovascular disease frequently fail due to a lack of suitable autologous grafts, as well as infection, thrombosis, and intimal hyperplasia associated with synthetic grafts. The rapid advancement of 3D printing and regenerative medicine technologies enabling the manufacture of biological, tissue-engineered vascular grafts (TEVGs) with the ability to integrate, remodel, and repair in vivo, promises a paradigm shift in cardiovascular disease management. This review comprehensively covers current state-of-the-art biofabrication technologies for the development of biomimetic TEVGs. Various scaffold based additive manufacturing methods used in vascular tissue engineering, including 3D printing, bioprinting, electrospinning and melt electrowriting, are discussed and assessed against the biomechanical and functional requirements of human vasculature, while the efficacy of decellularization protocols currently applied to engineered and native vessels are evaluated. Further, we provide interdisciplinary insight into the outlook of regenerative medicine for the development of vascular grafts, exploring key considerations and perspectives for the successful clinical integration of evolving technologies. It is expected that continued advancements in microscale additive manufacturing, biofabrication, tissue engineering and decellularization will culminate in the development of clinically viable, off-the-shelf TEVGs for small diameter applications in the near future. STATEMENT OF SIGNIFICANCE: Current clinical strategies for the management of cardiovascular disease using small diameter vessel bypassing procedures are inadequate, with up to 75% of synthetic grafts failing within 3 years of implantation. It is this critically important clinical problem that researchers in the field of vascular tissue engineering and regenerative medicine aim to alleviate using biofabrication methods combining additive manufacturing, biomaterials science and advanced cellular biology. While many approaches facilitate the development of bioengineered constructs which mimic the structure and function of native blood vessels, several challenges must still be overcome for clinical translation of the next generation of tissue-engineered vascular grafts.


Assuntos
Bioimpressão , Prótese Vascular , Materiais Biocompatíveis , Humanos , Impressão Tridimensional , Engenharia Tecidual , Alicerces Teciduais
8.
Intensive Care Med Exp ; 9(1): 60, 2021 Dec 24.
Artigo em Inglês | MEDLINE | ID: mdl-34950993

RESUMO

BACKGROUND: Heart transplantation (HTx) from brainstem dead (BSD) donors is the gold-standard therapy for severe/end-stage cardiac disease, but is limited by a global donor heart shortage. Consequently, innovative solutions to increase donor heart availability and utilisation are rapidly expanding. Clinically relevant preclinical models are essential for evaluating interventions for human translation, yet few exist that accurately mimic all key HTx components, incorporating injuries beginning in the donor, through to the recipient. To enable future assessment of novel perfusion technologies in our research program, we thus aimed to develop a clinically relevant sheep model of HTx following 24 h of donor BSD. METHODS: BSD donors (vs. sham neurological injury, 4/group) were hemodynamically supported and monitored for 24 h, followed by heart preservation with cold static storage. Bicaval orthotopic HTx was performed in matched recipients, who were weaned from cardiopulmonary bypass (CPB), and monitored for 6 h. Donor and recipient blood were assayed for inflammatory and cardiac injury markers, and cardiac function was assessed using echocardiography. Repeated measurements between the two different groups during the study observation period were assessed by mixed ANOVA for repeated measures. RESULTS: Brainstem death caused an immediate catecholaminergic hemodynamic response (mean arterial pressure, p = 0.09), systemic inflammation (IL-6 - p = 0.025, IL-8 - p = 0.002) and cardiac injury (cardiac troponin I, p = 0.048), requiring vasopressor support (vasopressor dependency index, VDI, p = 0.023), with normalisation of biomarkers and physiology over 24 h. All hearts were weaned from CPB and monitored for 6 h post-HTx, except one (sham) recipient that died 2 h post-HTx. Hemodynamic (VDI - p = 0.592, heart rate - p = 0.747) and metabolic (blood lactate, p = 0.546) parameters post-HTx were comparable between groups, despite the observed physiological perturbations that occurred during donor BSD. All p values denote interaction among groups and time in the ANOVA for repeated measures. CONCLUSIONS: We have successfully developed an ovine HTx model following 24 h of donor BSD. After 6 h of critical care management post-HTx, there were no differences between groups, despite evident hemodynamic perturbations, systemic inflammation, and cardiac injury observed during donor BSD. This preclinical model provides a platform for critical assessment of injury development pre- and post-HTx, and novel therapeutic evaluation.

9.
Sci Rep ; 11(1): 20458, 2021 10 14.
Artigo em Inglês | MEDLINE | ID: mdl-34650063

RESUMO

Refractory cardiogenic shock (CS) often requires veno-arterial extracorporeal membrane oxygenation (VA-ECMO) to sustain end-organ perfusion. Current animal models result in heterogenous cardiac injury and frequent episodes of refractory ventricular fibrillation. Thus, we aimed to develop an innovative, clinically relevant, and titratable model of severe cardiopulmonary failure. Six sheep (60 ± 6 kg) were anaesthetized and mechanically ventilated. VA-ECMO was commenced and CS was induced through intramyocardial injections of ethanol. Then, hypoxemic/hypercapnic pulmonary failure was achieved, through substantial decrease in ventilatory support. Echocardiography was used to compute left ventricular fractional area change (LVFAC) and cardiac Troponin I (cTnI) was quantified. After 5 h, the animals were euthanised and the heart was retrieved for histological evaluations. Ethanol (58 ± 23 mL) successfully induced CS in all animals. cTnI levels increased near 5000-fold. CS was confirmed by a drop in systolic blood pressure to 67 ± 14 mmHg, while lactate increased to 4.7 ± 0.9 mmol/L and LVFAC decreased to 16 ± 7%. Myocardial samples corroborated extensive cellular necrosis and inflammatory infiltrates. In conclusion, we present an innovative ovine model of severe cardiopulmonary failure in animals on VA-ECMO. This model could be essential to further characterize CS and develop future treatments.


Assuntos
Oxigenação por Membrana Extracorpórea/métodos , Insuficiência Respiratória/terapia , Choque Cardiogênico/terapia , Animais , Modelos Animais de Doenças , Ecocardiografia , Feminino , Miocárdio/patologia , Ovinos , Choque Cardiogênico/diagnóstico por imagem
10.
Physiol Rep ; 9(19): e15048, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34617676

RESUMO

The acute respiratory distress syndrome (ARDS) describes a heterogenous population of patients with acute severe respiratory failure. However, contemporary advances have begun to identify distinct sub-phenotypes that exist within its broader envelope. These sub-phenotypes have varied outcomes and respond differently to several previously studied interventions. A more precise understanding of their pathobiology and an ability to prospectively identify them, may allow for the development of precision therapies in ARDS. Historically, animal models have played a key role in translational research, although few studies have so far assessed either the ability of animal models to replicate these sub-phenotypes or investigated the presence of sub-phenotypes within animal models. Here, in three ovine models of ARDS, using combinations of oleic acid and intravenous, or intratracheal lipopolysaccharide, we investigated the presence of sub-phenotypes which qualitatively resemble those found in clinical cohorts. Principal Component Analysis and partitional clustering identified two clusters, differentiated by markers of shock, inflammation, and lung injury. This study provides a first exploration of ARDS phenotypes in preclinical models and suggests a methodology for investigating this phenomenon in future studies.


Assuntos
Fenótipo , Síndrome do Desconforto Respiratório/fisiopatologia , Animais , Citocinas/sangue , Modelos Animais de Doenças , Feminino , Lipopolissacarídeos , Ácido Oleico , Síndrome do Desconforto Respiratório/sangue , Síndrome do Desconforto Respiratório/induzido quimicamente , Ovinos
11.
ACS Biomater Sci Eng ; 7(9): 4402-4419, 2021 09 13.
Artigo em Inglês | MEDLINE | ID: mdl-34436868

RESUMO

Extracorporeal membrane oxygenation (ECMO) is used in critical care to manage patients with severe respiratory and cardiac failure. ECMO brings blood from a critically ill patient into contact with a non-endothelialized circuit which can cause clotting and bleeding simultaneously in this population. Continuous systemic anticoagulation is needed during ECMO. The membrane oxygenator, which is a critical component of the extracorporeal circuit, is prone to significant thrombus formation due to its large surface area and areas of low, turbulent, and stagnant flow. Various surface coatings, including but not limited to heparin, albumin, poly(ethylene glycol), phosphorylcholine, and poly(2-methoxyethyl acrylate), have been developed to reduce thrombus formation during ECMO. The present work provides an up-to-date overview of anti-thrombogenic surface coatings for ECMO, including both commercial coatings and those under development. The focus is placed on the coatings being developed for oxygenators. Overall, zwitterionic polymer coatings, nitric oxide (NO)-releasing coatings, and lubricant-infused coatings have attracted more attention than other coatings and showed some improvement in in vitro and in vivo anti-thrombogenic effects. However, most studies lacked standard hemocompatibility assessment and comparison studies with current clinically used coatings, either heparin coatings or nonheparin coatings. Moreover, this review identifies that further investigation on the thrombo-resistance, stability and durability of coatings under rated flow conditions and the effects of coatings on the function of oxygenators (pressure drop and gas transfer) are needed. Therefore, extensive further development is required before these new coatings can be used in the clinic.


Assuntos
Oxigenação por Membrana Extracorpórea , Trombose , Coagulação Sanguínea , Heparina , Humanos , Oxigenadores de Membrana , Trombose/prevenção & controle
12.
Front Cardiovasc Med ; 8: 647086, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33937360

RESUMO

All human cells are coated by a surface layer of proteoglycans, glycosaminoglycans (GAGs) and plasma proteins, called the glycocalyx. The glycocalyx transmits shear stress to the cytoskeleton of endothelial cells, maintains a selective permeability barrier, and modulates adhesion of blood leukocytes and platelets. Major components of the glycocalyx, including syndecans, heparan sulfate, and hyaluronan, are shed from the endothelial surface layer during conditions including ischaemia and hypoxia, sepsis, atherosclerosis, diabetes, renal disease, and some viral infections. Studying mechanisms of glycocalyx damage in vivo can be challenging due to the complexity of immuno-inflammatory responses which are inextricably involved. Previously, both static as well as perfused in vitro models have studied the glycocalyx, and have reported either imaging data, assessment of barrier function, or interactions of blood components with the endothelial monolayer. To date, no model has simultaneously incorporated all these features at once, however such a model would arguably enhance the study of vasculopathic processes. This review compiles a series of current in vitro models described in the literature that have targeted the glycocalyx layer, their limitations, and potential opportunities for further developments in this field.

13.
Pharmacol Res ; 169: 105631, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33905863

RESUMO

BACKGROUND: Heart failure is an inexorably progressive disease with a high mortality, for which heart transplantation (HTx) remains the gold standard treatment. Currently, donor hearts are primarily derived from patients following brain stem death (BSD). BSD causes activation of the sympathetic nervous system, increases endothelin levels, and triggers significant inflammation that together with potential myocardial injury associated with the transplant procedure, may affect contractility of the donor heart. We examined peri-transplant myocardial catecholamine sensitivity and cardiac contractility post-BSD and transplantation in a clinically relevant ovine model. METHODS: Donor sheep underwent BSD (BSD, n = 5) or sham (no BSD) procedures (SHAM, n = 4) and were monitored for 24h prior to heart procurement. Orthotopic HTx was performed on a separate group of donor animals following 24h of BSD (BSD-Tx, n = 6) or SHAM injury (SH-Tx, n = 5). The healthy recipient heart was used as a control (HC, n = 11). A cumulative concentration-effect curve to (-)-noradrenaline (NA) was established using left (LV) and right ventricular (RV) trabeculae to determine ß1-adrenoceptor mediated potency (-logEC50 [(-)-noradrenaline] M) and maximal contractility (Emax). RESULTS: Our data showed reduced basal and maximal (-)-noradrenaline induced contractility of the RV (but not LV) following BSD as well as HTx, regardless of whether the donor heart was exposed to BSD or SHAM. The potency of (-)-noradrenaline was lower in left and right ventricles for BSD-Tx and SH-Tx compared to HC. CONCLUSION: These studies show that the combination of BSD and transplantation are likely to impair contractility of the donor heart, particularly for the RV. For the donor heart, this contractile dysfunction appears to be independent of changes to ß1-adrenoceptor sensitivity. However, altered ß1-adrenoceptor signalling is likely to be involved in post-HTx contractile dysfunction.


Assuntos
Morte Encefálica/patologia , Tronco Encefálico/patologia , Transplante de Coração/efeitos adversos , Disfunção Ventricular Direita/etiologia , Animais , Modelos Animais de Doenças , Feminino , Contração Miocárdica , Ovinos , Disfunção Ventricular Direita/patologia
14.
ASAIO J ; 67(4): 416-422, 2021 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-33769996

RESUMO

This study investigated the accuracy of the HeartWare HVAD flow estimator for left ventricular assist device (LVAD) support and biventricular assist device (BiVAD) support for modes of reduced speed (BiVAD-RS) and banded outflow (BiVAD-B). The HVAD flow estimator was evaluated in a mock circulatory loop under changes in systemic and pulmonary vascular resistance, heart rate, central venous pressure, and simulated hematocrit (correlated to viscosity). A difference was found between mean estimated and mean measured flow for LVAD (0.1 ± 0.3 L/min), BiVAD-RS (-0.1 ± 0.2 L/min), and BiVAD-B (0 ± 0.2 L/min). Analysis of the flow waveform pulsatility showed good correlation for LVAD (r2 = 0.98) with a modest spread in error (0.7 ± 0.1 L/min), while BiVAD-RS and BiVAD-B showed similar spread in error (0.7 ± 0.3 and 0.7 ± 0.2 L/min, respectively), with much lower correlation (r2 = 0.85 and r2 = 0.60, respectively). This study demonstrated that the mean flow error of the HVAD flow estimator is similar when the device is used in LVAD, BiVAD-RS, or BiVAD-B configuration. However, the instantaneous flow waveform should be interpreted with caution, particularly in the cases of BiVAD support.


Assuntos
Coração Auxiliar , Hemodinâmica/fisiologia , Modelos Cardiovasculares , Disfunção Ventricular Esquerda/fisiopatologia , Feminino , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/terapia , Ventrículos do Coração/fisiopatologia , Humanos , Masculino , Estudos Retrospectivos , Disfunção Ventricular Esquerda/terapia , Disfunção Ventricular Direita/fisiopatologia , Disfunção Ventricular Direita/terapia
15.
Intensive Care Med Exp ; 9(1): 5, 2021 Jan 04.
Artigo em Inglês | MEDLINE | ID: mdl-33502631

RESUMO

BACKGROUND: Extracorporeal membrane oxygenation (ECMO), an invasive mechanical therapy, provides cardio-respiratory support to critically ill patients when maximal conventional support has failed. ECMO is delivered via large-bore cannulae which must be effectively secured to avoid complications including cannula migration, dislodgement and accidental decannulation. Growing evidence suggests tissue adhesive (TA) may be a practical and safe method to secure vascular access devices, but little evidence exists pertaining to securement of ECMO cannulae. The aim of this study was to determine the safety and efficacy of two TA formulations (2-octyl cyanoacrylate and n-butyl-2-octyl cyanoacrylate) for use in peripherally inserted ECMO cannula securement, and compare TA securement to 'standard' securement methods. METHODS: This in vitro project assessed: (1) the tensile strength and flexibility of TA formulations compared to 'standard' ECMO cannula securement using a porcine skin model, and (2) the chemical resistance of the polyurethane ECMO cannulae to TA. An Instron 5567 Universal Testing System was used for strength testing in both experiments. RESULTS: Securement with sutures and n-butyl-2-octyl cyanoacrylate both significantly increased the force required to dislodge the cannula compared to a transparent polyurethane dressing (p = 0.006 and p = 0.003, respectively) and 2-octyl cyanoacrylate (p = 0.023 and p = 0.013, respectively). Suture securement provided increased flexibility compared to TA securement (p < 0.0001), and there was no statistically significant difference in flexibility between 2-octyl cyanoacrylate and n-butyl-2-octyl cyanoacrylate (p = 0.774). The resistance strength of cannula polyurethane was not weakened after exposure to either TA formulation after 60 min compared to control. CONCLUSIONS: Tissue adhesive appears to be a promising adjunct method of ECMO cannula insertion site securement. Tissue adhesive securement with n-butyl-2-octyl cyanoacrylate may provide comparable securement strength to a single polypropylene drain stitch, and, when used as an adjunct securement method, may minimise the risks associated with suture securement. However, further clinical research is still needed in this area.

16.
Am J Respir Crit Care Med ; 202(3): 383-392, 2020 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-32293914

RESUMO

Rationale: Mesenchymal stromal cell (MSC) therapy is a promising intervention for acute respiratory distress syndrome (ARDS), although trials to date have not investigated its use alongside extracorporeal membrane oxygenation (ECMO). Recent preclinical studies have suggested that combining these interventions may attenuate the efficacy of ECMO.Objectives: To determine the safety and efficacy of MSC therapy in a model of ARDS and ECMO.Methods: ARDS was induced in 14 sheep, after which they were established on venovenous ECMO. Subsequently, they received either endobronchial induced pluripotent stem cell-derived human MSCs (hMSCs) (n = 7) or cell-free carrier vehicle (vehicle control; n = 7). During ECMO, a low Vt ventilation strategy was employed in addition to protocolized hemodynamic support. Animals were monitored and supported for 24 hours. Lung tissue, bronchoalveolar fluid, and plasma were analyzed, in addition to continuous respiratory and hemodynamic monitoring.Measurements and Main Results: The administration of hMSCs did not improve oxygenation (PaO2/FiO2 mean difference = -146 mm Hg; P = 0.076) or pulmonary function. However, histological evidence of lung injury (lung injury score mean difference = -0.07; P = 0.04) and BAL IL-8 were reduced. In addition, hMSC-treated animals had a significantly lower cumulative requirement for vasopressor. Despite endobronchial administration, animals treated with hMSCs had a significant elevation in transmembrane oxygenator pressure gradients. This was accompanied by more pulmonary artery thromboses and adherent hMSCs found on explanted oxygenator fibers.Conclusions: Endobronchial hMSC therapy in an ovine model of ARDS and ECMO can impair membrane oxygenator function and does not improve oxygenation. These data do not recommend the safe use of hMSCs during venovenous ECMO.


Assuntos
Lesão Pulmonar Aguda/patologia , Oxigenação por Membrana Extracorpórea , Pulmão/patologia , Transplante de Células-Tronco Mesenquimais , Síndrome do Desconforto Respiratório/terapia , Lesão Pulmonar Aguda/imunologia , Animais , Líquido da Lavagem Broncoalveolar/imunologia , Adesão Celular , Modelos Animais de Doenças , Humanos , Células-Tronco Pluripotentes Induzidas , Interleucina-8/imunologia , Pulmão/imunologia , Oxigenadores de Membrana , Artéria Pulmonar , Distribuição Aleatória , Respiração Artificial , Síndrome do Desconforto Respiratório/imunologia , Síndrome do Desconforto Respiratório/patologia , Ovinos , Carneiro Doméstico , Trombose/patologia , Vasoconstritores/uso terapêutico
17.
Transplantation ; 104(11): 2272-2289, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32150037

RESUMO

Despite advances in mechanical circulatory devices and pharmacologic therapies, heart transplantation (HTx) is the definitive and most effective therapy for an important proportion of qualifying patients with end-stage heart failure. However, the demand for donor hearts significantly outweighs the supply. Hearts are sourced from donors following brain death, which exposes donor hearts to substantial pathophysiological perturbations that can influence heart transplant success and recipient survival. Although significant advances in recipient selection, donor and HTx recipient management, immunosuppression, and pretransplant mechanical circulatory support have been achieved, primary graft dysfunction after cardiac transplantation continues to be an important cause of morbidity and mortality. Animal models, when appropriate, can guide/inform medical practice, and fill gaps in knowledge that are unattainable in clinical settings. Consequently, we performed a systematic review of existing animal models that incorporate donor brain death and subsequent HTx and assessed studies for scientific rigor and clinical relevance. Following literature screening via the U.S National Library of Medicine bibliographic database (MEDLINE) and Embase, 29 studies were assessed. Analysis of included studies identified marked heterogeneity in animal models of donor brain death coupled to HTx, with few research groups worldwide identified as utilizing these models. General reporting of important determinants of heart transplant success was mixed, and assessment of posttransplant cardiac function was limited to an invasive technique (pressure-volume analysis), which is limitedly applied in clinical settings. This review highlights translational challenges between available animal models and clinical heart transplant settings that are potentially hindering advancement of this field of investigation.


Assuntos
Morte Encefálica , Insuficiência Cardíaca/cirurgia , Transplante de Coração/efeitos adversos , Disfunção Primária do Enxerto/etiologia , Doadores de Tecidos , Animais , Insuficiência Cardíaca/fisiopatologia , Hemodinâmica , Humanos , Modelos Animais , Disfunção Primária do Enxerto/fisiopatologia , Especificidade da Espécie , Função Ventricular Esquerda , Função Ventricular Direita
18.
J Biomed Mater Res B Appl Biomater ; 108(3): 738-749, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-31169980

RESUMO

The interface between synthetic percutaneous devices and skin is a common area for bacterial infection, which may ultimately result in failure of the device. Better integration of percutaneous devices with skin may help reduce infection rates due to the creation of a dermal seal. However, the mismatch in material and chemical properties of devices and skin presents a challenge for closing the dermal gap at the skin-device interface. Here, we have used a tissue engineering approach to tissue integration by creating a highly fibrous poly(ε-caprolactone) scaffold using melt electrowriting and seeding this with dermal fibroblasts, followed by maturation and insertion into a full-thickness defect made in an ex vivo skin model. The integration of seeded scaffolds was compared with controls including a non-seeded scaffold and a polymer tube with a smooth surface. Dermal fibroblast inclusion in the scaffold and epidermal upgrowth versus downgrowth/marsupialization around the device were used as measures of integration. Based on these measures, almost all pre-seeded scaffolds performed better than both the non-seeded scaffolds and smooth tubes. The hypothesis is that the fibroblasts act as a barrier to epithelial downward migration, and provide healthy tissue for nascent epidermal development.


Assuntos
Materiais Biocompatíveis/química , Nanofibras/química , Poliésteres/química , Alicerces Teciduais/química , Materiais Biocompatíveis/metabolismo , Células Cultivadas , Fibroblastos/citologia , Humanos , Testes Mecânicos , Poliésteres/metabolismo , Implantação de Prótese , Pele , Propriedades de Superfície , Engenharia Tecidual
19.
Int J Mol Sci ; 20(15)2019 Aug 05.
Artigo em Inglês | MEDLINE | ID: mdl-31387264

RESUMO

Cardiovascular disease is the largest contributor to worldwide mortality, and the deleterious impact of heart failure (HF) is projected to grow exponentially in the future. As heart transplantation (HTx) is the only effective treatment for end-stage HF, development of mechanical circulatory support (MCS) technology has unveiled additional therapeutic options for refractory cardiac disease. Unfortunately, despite both MCS and HTx being quintessential treatments for significant cardiac impairment, associated morbidity and mortality remain high. MCS technology continues to evolve, but is associated with numerous disturbances to cardiac function (e.g., oxidative damage, arrhythmias). Following MCS intervention, HTx is frequently the destination option for survival of critically ill cardiac patients. While effective, donor hearts are scarce, thus limiting HTx to few qualifying patients, and HTx remains correlated with substantial post-HTx complications. While MCS and HTx are vital to survival of critically ill cardiac patients, cardioprotective strategies to improve outcomes from these treatments are highly desirable. Accordingly, this review summarizes the current status of MCS and HTx in the clinic, and the associated cardiac complications inherent to these treatments. Furthermore, we detail current research being undertaken to improve cardiac outcomes following MCS/HTx, and important considerations for reducing the significant morbidity and mortality associated with these necessary treatment strategies.


Assuntos
Estado Terminal , Cardiopatias/prevenção & controle , Insuficiência Cardíaca/prevenção & controle , Suporte Vital Cardíaco Avançado/métodos , Animais , Cardiopatias/diagnóstico , Cardiopatias/etiologia , Cardiopatias/terapia , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/terapia , Transplante de Coração/métodos , Humanos , Terapia de Imunossupressão/métodos
20.
Perfusion ; 34(1_suppl): 15-21, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30966907

RESUMO

INTRODUCTION: Mesenchymal stem cells exhibit immunomodulatory properties which are currently being investigated as a novel treatment option for Acute Respiratory Distress Syndrome. However, the feasibility and efficacy of mesenchymal stem cell therapy in the setting of extracorporeal membrane oxygenation is poorly understood. This study aimed to characterise markers of innate immune activation in response to mesenchymal stem cells during an ex vivo simulation of extracorporeal membrane oxygenation. METHODS: Ex vivo extracorporeal membrane oxygenation simulations (n = 10) were conducted using a commercial extracorporeal circuit with a CO2-enhanced fresh gas supply and donor human whole blood. Heparinised circuits (n = 4) were injected with 40 × 106-induced pluripotent stem cell-derived human mesenchymal stem cells, while the remainder (n = 6) acted as controls. Simulations were maintained, under physiological conditions, for 240 minutes. Circuits were sampled at 15, 30, 60, 120 and 240 minutes and assessed for levels of interleukin-1ß, interleukin-6, interleukin-8, interleukin-10, tumour necrosis factor-α, transforming growth factor-ß1, myeloperoxidase and α-Defensin-1. In addition, haemoglobin, platelet and leukocyte counts were performed. RESULTS: There was a trend towards reduced levels of pro-inflammatory cytokines in mesenchymal stem cell-treated circuits and a significant increase in transforming growth factor-ß1. Blood cells and markers of neutrophil activation were reduced in mesenchymal stem cell circuits during the length of the simulation. As previously reported, the addition of mesenchymal stem cells resulted in a reduction of flow and increased trans-oxygenator pressures in comparison to controls. CONCLUSIONS: The addition of mesenchymal stem cells during extracorporeal membrane oxygenation may cause an increase in transforming growth factor-ß1. This is despite their ability to adhere to the membrane oxygenator. Further studies are required to confirm these findings.


Assuntos
Oxigenação por Membrana Extracorpórea/métodos , Imunidade Inata/imunologia , Inflamação/metabolismo , Células-Tronco Mesenquimais/metabolismo , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...