Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Diagnostics (Basel) ; 14(2)2024 Jan 08.
Artigo em Inglês | MEDLINE | ID: mdl-38248025

RESUMO

The aim of our study was to establish and compare the diagnostic accuracy and clinical applicability of published chest CT severity scoring systems used for COVID-19 pneumonia assessment and to propose the most efficient CT scoring system with the highest diagnostic performance and the most accurate prediction of disease severity. This retrospective study included 218 patients with PCR-confirmed SARS-CoV-2 infection and chest CT. Two radiologists blindly evaluated CT scans and calculated nine different CT severity scores (CT SSs). The diagnostic validity of CT SSs was tested by ROC analysis. Interobserver agreement was excellent (intraclass correlation coefficient: 0.982-0.995). The predominance of either consolidations or a combination of consolidations and ground-glass opacities (GGOs) was a predictor of more severe disease (both p < 0.005), while GGO prevalence alone was not. Correlation between all CT SSs was high, ranging from 0.848 to 0.971. CT SS 30 had the highest diagnostic accuracy (AUC = 0.805) in discriminating mild from severe COVID-19 disease compared to all the other proposed scoring systems (AUC range 0.755-0.788). In conclusion, CT SS 30 achieved the highest diagnostic accuracy in predicting the severity of COVID-19 disease while maintaining simplicity, reproducibility, and applicability in complex clinical settings.

2.
Neuroradiol J ; 35(3): 337-345, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34550827

RESUMO

BACKGROUND: Virtual monoenergetic (VM) dual-energy computed tomography (DE-CT) enables grey-to-white matter contrast-to-noise ratio optimization, potentially increasing ischaemic brain oedema visibility. The aim of this study was to compare the diagnostic accuracy of VM and standard DE-CT reconstructions for early stroke detection. METHODS: Consecutive patients with non-contrast DE-CT of the brain scanned within 12 h of stroke symptom onset were prospectively included in the study. Patients with other significant brain pathology were excluded. Two radiologists jointly evaluated standard and VM reconstructions (from 40 to 190 keV at increments of 10 keV) for early stroke signs on a four-point Likert scale: (a) stroke definitely present, (b) stroke probably present, (c) probably no stroke, and (d) definitely no stroke. Follow-up imaging and clinical data served as the standard of reference. Diagnostic accuracy was evaluated by receiver operating characteristic analysis. RESULTS: Stroke incidence among 184 patients was 76%. In 64 patients follow-up imaging served as the standard of reference: ischemic brain oedema detection was significantly more accurate on VM reconstructions at 80 keV compared with standard DE-CT reconstructions (area under the curve (AUC) = 0.821 vs. AUC = 0.672, p = 0.002). The difference was most prominent within the first 3 h after symptom onset (at 11%, AUC = 0.819 vs. AUC = 0.709, p = 0.17) and in patients with National Institutes of Health Stroke Scale above 16 (at 37.5%, AUC = 1 vs. AUC = 0.625, p = 0.14). CONCLUSION: VM DE-CT reconstructions at 80 keV appear to be the optimal non-contrast CT technique for diagnosing early ischaemic stroke, particularly within the first 3 h after symptom onset and in severely ill patients.


Assuntos
Edema Encefálico , Isquemia Encefálica , Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Acidente Vascular Cerebral , Isquemia Encefálica/diagnóstico por imagem , Humanos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Estudos Retrospectivos , Acidente Vascular Cerebral/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...