Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Nucl Med ; 34(2): 193-8, 1993 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-8429336

RESUMO

Patients with reduced left ventricular function or aneurysms have cavities that appear dark on SPECT thallium scintigrams. We hypothesized that a quantitative index, which relates thallium activity in the left ventricular cavity to that in the myocardium (C/M ratio), could provide information on left ventricular function. A group of 80 patients who had both exercise SPECT thallium imaging and cardiac catheterization were studied. The C/M ratio was obtained from the short-axis tomogram on both exercise and rest images. Counts in a 2 x 2 pixel region of interest in the left ventricular cavity were divided by the number of counts in the "hottest" area of the myocardium. Plotting the angiographically determined ejection fraction against the C/M exercise and rest ratios, we observed a linear correlation between ejection fraction and both C/M ratios, r = 0.65 for C/M exercise and r = 0.67 for C/M rest ratio (p < 0.00001). Using data from 12 normal cardiac catheterization patients, we established the lower limit of normal; 50% for ejection fraction and 0.40 for the C/M ratios. A C/M exercise ratio < or = 0.40 identified 26 of 31 patients with an ejection fraction < or = 50%. A C/M exercise ratio > 0.40 identified 39 of 49 patients with an ejection fraction > 50%. These calculations yielded a sensitivity of 83% and specificity of 78% for the C/M exercise ratio. A similar analysis for C/M rest ratio revealed sensitivity of 61% and specificity of 92%. The present study shows that an abnormal C/M ratio correctly distinguishes patients with abnormal from normal ejection fractions with an accuracy of 81%. The C/M ratio is easily obtained, requires minimal processing time and is highly reproducible. These attributes may enable this index to add supplementary information regarding left ventricular function in addition to perfusion from thallium imaging.


Assuntos
Coração/diagnóstico por imagem , Radioisótopos de Tálio , Tomografia Computadorizada de Emissão de Fóton Único , Adulto , Idoso , Idoso de 80 Anos ou mais , Cateterismo Cardíaco , Doença das Coronárias/diagnóstico por imagem , Doença das Coronárias/fisiopatologia , Teste de Esforço , Feminino , Ventrículos do Coração/diagnóstico por imagem , Humanos , Pulmão/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Volume Sistólico , Função Ventricular Esquerda
2.
Chest ; 100(3): 852-3, 1991 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-1889285

RESUMO

We report a case of pseudo-tricuspid stenosis as a result of extrinsic compression of the tricuspid valve by a large right-sided pericardial effusion. Two-dimensional echocardiography and continuous-wave Doppler enabled accurate noninvasive diagnosis and hemodynamic assessment.


Assuntos
Ecocardiografia , Estenose da Valva Tricúspide/diagnóstico , Adulto , Ecocardiografia Doppler , Soropositividade para HIV/complicações , Humanos , Masculino , Derrame Pericárdico/complicações , Derrame Pericárdico/diagnóstico , Derrame Pericárdico/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Estenose da Valva Tricúspide/etiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA