Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
J Matern Fetal Neonatal Med ; 36(1): 2170749, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36710393

RESUMO

OBJECTIVE: To describe the prevalence and predictors of postpartum sleep disorders. DESIGN: A retrospective cohort study. SETTING: Postpartum. POPULATION: Commercially insured women delivering in California (USA) between 2011 and 2014. METHODS: Using the Optum Clinformatics Datamart Database. MAIN OUTCOME MEASURES: Prevalence of a postpartum sleep disorder diagnosis with and without a depression diagnosis up to 12 months following hospital discharge for inpatient delivery. We also identified predictors of a postpartum sleep disorder diagnosis using multivariable logistic regression. RESULTS: We identified 3535 (1.9%) women with a postpartum sleep disorder diagnosis. The prevalence of sleep disorder diagnoses was insomnia (1.3%), sleep apnea (0.25%), and other sleep disorder (0.25%). The odds of a postpartum sleep disorder were highest among women with a history of drug abuse (adjusted odds ratio (aOR): 2.70, 95% confidence interval (CI): 1.79-4.09); a stillbirth delivery (aOR: 2.15, 95% CI: 1.53-3.01); and chronic hypertension (aOR: 1.82; 95% CI: 1.57-2.11). A comorbid diagnosis of a postpartum sleep disorder and depression occurred in 1182 women (0.6%). These women accounted for 33.4% of all women with a postpartum sleep disorder. The strongest predictors of a comorbid diagnosis were a history of drug abuse (aOR: 4.13; 95% CI: 2.37-7.21) and a stillbirth delivery (aOR: 2.93; 95% CI: 1.74-4.92). CONCLUSIONS: Postpartum sleep disorders are underdiagnosed conditions, with only 2% of postpartum women in this cohort receiving a sleep diagnosis using International Classification of Diseases, 9th Revision, Clinical Modification (ICD-9-CM) codes. Insomnia was the most common disorder and one-third of women diagnosed with a postpartum sleep disorder had a co-morbid diagnosis of depression. Future studies are needed to improve the screening and diagnostic accuracy of postpartum sleep disorders.


Assuntos
Depressão Pós-Parto , Transtornos Puerperais , Distúrbios do Início e da Manutenção do Sono , Transtornos do Sono-Vigília , Transtornos Relacionados ao Uso de Substâncias , Gravidez , Humanos , Feminino , Masculino , Prevalência , Estudos Retrospectivos , Natimorto , Período Pós-Parto , Transtornos do Sono-Vigília/epidemiologia , Transtornos Relacionados ao Uso de Substâncias/complicações , Transtornos Relacionados ao Uso de Substâncias/epidemiologia , Sono , Depressão Pós-Parto/diagnóstico , Depressão Pós-Parto/epidemiologia
2.
Sleep ; 44(10)2021 10 11.
Artigo em Inglês | MEDLINE | ID: mdl-34013345

RESUMO

STUDY OBJECTIVES: We performed a systematic review to identify the best patient-reported outcome measure (PROM) of postpartum sleep in women. METHODS: We searched four databases for validated PROMs used to assess postpartum sleep. Studies were considered if they evaluated at least one psychometric measurement property of a PROM. An overall performance rating was assigned for each psychometric measurement property of each PROM based upon COSMIN criteria. A modified GRADE approach was used to assess the level of evidence and recommendations were then made for each PROM. RESULTS: We identified 15 validation studies of eight PROMs, in 9,070 postpartum women. An adequate number of sleep domains was assessed by five PROMs: Bergen Insomnia Scale (BIS), Pittsburgh Sleep Quality Index (PSQI), General Sleep Disturbance Scale (GSDS), Athens Insomnia Scale (AIS), and the Sleep Symptom Checklist (SSC). BIS and GSDS were the only PROMs to demonstrate adequate content validity and at least a low level of evidence of sufficient internal consistency, resulting in Class A recommendations. The BIS was the only PROM, which is easily accessible and free to use for noncommercial research, that achieved a Class A recommendation. CONCLUSION: The BIS is the best currently available PROM of postpartum sleep. However, this PROM fails to assess several important domains such as sleep duration (and efficiency), chronotype, sleep-disordered breathing and medication usage. Future studies should focus on evaluating the psychometric measurement properties of BIS in the North American setting and in different cultural groups, or to develop a more specific PROM of postpartum sleep.


Assuntos
Medidas de Resultados Relatados pelo Paciente , Sono , Consenso , Feminino , Humanos , Período Pós-Parto , Psicometria , Qualidade de Vida , Inquéritos e Questionários
3.
Mult Scler ; 14(1): 140-2, 2008 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-18089672

RESUMO

The present study examined the relationship between the worsening of symptoms across a 3-5-year period of time and self-reported physical activity in a sample of 51 individuals with multiple sclerosis (MS). Of the 51 participants, 35 reported a worsening of symptoms over the 3-5-year period of time. The worsening of symptoms was associated with significantly and moderately lower levels of self-reported physical activity independent of depression and EDSS scores and MS-disease course (P=0.04). This study provides novel evidence that a worsening of symptoms is associated with lower levels of physical activity in individuals with MS.


Assuntos
Avaliação da Deficiência , Exercício Físico , Atividade Motora , Esclerose Múltipla/fisiopatologia , Adulto , Depressão/psicologia , Progressão da Doença , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Esclerose Múltipla/psicologia , Testes Neuropsicológicos , Inquéritos e Questionários
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...