Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
2.
Clin Ophthalmol ; 15: 591-599, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33623360

RESUMO

PURPOSE: To evaluate intraoperative intraocular lens (IOL) delivery time and total surgical case time using the UltraSert preloaded delivery system (System U) during routine cataract surgeries and to compare with the manually loaded Monarch delivery system (System M). Physician satisfaction with System U was also assessed. PATIENTS AND METHODS: In this prospective observational study, subjects ≥18 years old underwent cataract surgery in 1 eye and received the AcrySof IQ IOL via the manually loaded System M (n=103) or the AcrySof IQ IOL model AU00T0 via the preloaded System U (n=93). Procedures were digitally recorded by an external camera or by a camera within the operating microscope. Device preparation, IOL delivery, and IOL positioning times were evaluated by 2 independent graders. Pearson χ2 test or Fisher exact test was used for categorical variables and Student's t-test or Wilcoxon rank-sum test for continuous variables (all tests were 2-sided and performed at a 5% α-level). Physician satisfaction levels were assessed using questionnaires. RESULTS: Lens delivery time was similar for System U and System M (12.9±5.1 and 12.2±6.3 s; P=0.412). Mean device preparation time for System U was significantly shorter compared with System M (30.3±6.6 versus 59.8±31.0 s; P<0.05). This resulted in a significantly shorter total intraoperative time (device preparation + lens delivery) with System U versus System M (43.0±8.6 versus 72.0±32.5 s; P<0.05). Total surgical case time (device preparation + lens delivery + lens positioning and unfolding) was shorter for System U versus System M (56.6±12.6 versus 89.6±34.6 s; P<0.05). Physicians reported greater satisfaction levels with System U compared with other devices. CONCLUSION: Use of the preloaded delivery system (System U) resulted in faster device preparation and reduced total surgical time compared with the manually loaded system (System M). System U was intuitive to use, and physicians preferred it to other devices.

3.
J Curr Ophthalmol ; 33(4): 485-491, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-35128199

RESUMO

PURPOSE: To describe a case where prophylactic use of nonsteroidal anti-inflammatory drugs (NSAID) eye drops lead to recurrent corneal melt with loss of vision and a brief literature review. METHODS: This is a case report of an 84-year-old diabetic female with chronic dry eye, operated by two different surgeons on each eye at different time intervals. She received topical NSAID prophylaxis after the second surgery only, which led to blindness due to recurrent corneal melt and chronic choroidal effusions. We also present a brief literature review. RESULTS: This lady presented with corneal melt and perforation 5 days following the use of topical NSAIDs prophylaxis after a routine cataract surgery in the second eye. Unfortunately, all efforts to save her vision and eye were unsuccessful as she developed repeated complications in spite of corneal gluing, amniotic membrane, penetrating keratoplasty, and tarsorrhaphy. She also had chronic choroidal effusions. She ended up with an opaque cornea and a subtotal tarsorrhaphy, with no other option to improve her vision as she did not qualify for sedation or general anesthesia due to her poor systemic health. CONCLUSION: Although it is a common practice for diabetic patients to have topical NSAIDs prophylaxis in combination with steroid eye drops to reduce the risk of cystoid macular edema after cataract surgery, the elderly diabetic patients with concomitant dry eyes should be considered high risk for corneal melt and should be closely monitored. This case highlights the rare but serious complication of topical NSAIDs prophylaxis in the vulnerable cornea, which warrants careful consideration.

4.
Int J Ophthalmol ; 11(8): 1308-1316, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30140634

RESUMO

AIM: To compare intraoperative phacoemulsification parameters and its effect on the corneal endothelium of eyes undergoing femtosecond laser-assisted cataract surgery (FLACS) versus conventional phacoemulsification (CP) cataract surgery. METHODS: Two hundred eyes from one hundred patients were included in a prospective, non-blinded, randomized, controlled, intraindividual clinical study. One hundred eyes underwent FLACS while their one hundred fellow eyes underwent CP. All surgeries were performed using the Victus® femtosecond laser platform and Infinity® Vision System phacoemulsification machine. Primary outcome measure was endothelial cell density 6mo after surgery. Secondary outcome measures included central corneal thickness (CCT), average cell area, standard deviation, coefficient of variation and hexagonality before surgery and 6mo after surgery and endothelial cell density loss during this period were also evaluated. Intraoperative efficiency parameters [cumulative dissipated energy (CDE), total intraocular surgery time, total ultrasound time, total phacoemulsification time, total torsional energy time, total aspiration time, ultrasound energy, torsional amplitude and fluid required during surgery] were also collated. RESULTS: Data from these patients was not considered for analysis. Data from 92 patients were analysed. Postoperative endothelial cell density (cells/mm2) between groups (2211.88±392.49 CP; 2246.31±403.48 FLACS) was not statistically significant (P=0.869). Total ultrasound time, torsional energy time, CDE and fluid requirements were significantly lower the FLACS group (P<0.05). Other parameters did not show statistically significant difference between FLACS and CP. CONCLUSION: FLACS displays significant improvements in phacoemulsification parameters in comparison to CP. There are no significant differences in corneal endothelium measures between FLACS and CP.

5.
Int J Ophthalmol ; 11(4): 623-628, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29675381

RESUMO

AIM: To analyze and compare five different variables over one year follow-up (1wk, 1, 3, 6 and 12mo): anterior capsule (AC), and posterior capsule (PC) area densitometry values, AC and PC linear densitometry values, and AC opening area reduction ratio after femtosecond laser-assisted cataract surgery. METHODS: This was a prospective comparative study. Seventy-one patients underwent femtosecond laser-assisted cataract surgery on single eye between June 2014 and December 2015. A 5.0 mm diameter laser assisted anterior capsulotomy was performed on all eyes. In every post-surgery evaluation, AC opacificaction (ACO) and PC opacification (PCO) density levels were provided by Oculus Pentacam®HR using area and linear densitometry methods. Digital images were captured with a slit-lamp Topcon photographic camera and IMAGEnet® 5 software. The AC opening area on the digital images was measured using the Sketchandcalc area calculator and converted to reduction ratio levels. RESULTS: Using Pearson correlation coefficient (PCC), we found no correlation (r=-0.091, P=0.46) in the twelfth month assessment between the evolution of ACO area densitometry values and PCO area densitometry values considered as independent variables. We found no correlation, using PCC (r=-0.096, P=0.43) between the evolution of ACO linear densitometry values and PCO linear densitometry values, in the twelfth month visit, working both as independent variables. AC linear densitometry levels and AC area densitometry levels continued to grow strongly from sixth to twelfth months. Analysis of the values of AC opening area reduction ratio (1wk, 1, 3, 6, 12mo) revealed statistically significant differences between the values of successive examinations but the magnitude of the change decreased. In the final period of monitoring between six and twelve months the magnitude of change was low. CONCLUSION: Our results show strong increases of Scheimpflug ACO densitometry values from the sixth to the twelfth month while capsulorhexis area reduction ratio levels displayed a considerable decrease. We found no correlation between ACO area and linear densitometry values and PCO area and linear densitometry values, in the twelfth month examination, working as independent variables.

6.
Biochim Biophys Acta ; 1862(10): 2015-21, 2016 10.
Artigo em Inglês | MEDLINE | ID: mdl-27497833

RESUMO

In this work we have analyzed the expression levels of the main aquaporins (AQPs) expressed in human lens epithelial cells (HLECs) using 112 samples from patients treated with cataract surgery and 36 samples from individuals treated with refractive surgery, with transparent lenses as controls. Aquaporin-1 (AQP1) is the main AQP, representing 64.1% of total AQPs in HLECs, with aquaporin-5 (AQP5) representing 35.9% in controls. A similar proportion of each AQP in cataract was found. Although no differences were found at the mRNA level compared to controls, a significant 1.65-fold increase (p=0.001) in AQP1protein expression was observed in HLECs from cataract patients, with the highest differences being found for nuclear cataracts (2.1-fold increase; p<0.001). A similar trend was found for AQP5 (1.47-fold increase), although the difference was not significant (p=0.161). Moreover we have shown increased membrane AQP5 protein expression in HLECs of patients with cataracts. No association of AQP1 or AQP5 expression levels with age or sex was observed in either group. Our results suggest regulation of AQP1 and AQP5 at the post-translational level and support previous observations on the implication of AQP1 and 5 in maintenance of lens transparency in animal models. Our results likely reflect a compensatory response of the crystalline lens to delay cataract formation by increasing the water removal rate.


Assuntos
Aquaporina 1/biossíntese , Aquaporina 5/biossíntese , Catarata/metabolismo , Células Epiteliais/metabolismo , Regulação da Expressão Gênica , Cápsula do Cristalino/metabolismo , Adulto , Idoso , Idoso de 80 Anos ou mais , Catarata/patologia , Células Epiteliais/patologia , Feminino , Humanos , Cápsula do Cristalino/patologia , Masculino , Pessoa de Meia-Idade , RNA Mensageiro/metabolismo
7.
J Cataract Refract Surg ; 42(6): 826-32, 2016 06.
Artigo em Inglês | MEDLINE | ID: mdl-27373388

RESUMO

PURPOSE: To compare the clinical classification of anterior capsule opacification (ACO) after femtosecond laser-assisted cataract surgery with the mean density values of ACO provided by rotating Scheimpflug device (Pentacam HR) densitometry software and to determine which densitometry method correlates best with the clinical classification. SETTING: Ophthalmology Department, Donostia University Hospital, Donostia-San Sebastian, Spain. DESIGN: Prospective comparative study. METHODS: Femtosecond laser-assisted cataract surgery was performed using the Victus platform between June 2014 and March 2015. Inclusion criteria were age between 55 years and 85 years, a pupil diameter larger than 6.0 mm in full mydriasis, no intraoperative complications, a curvilinear anterior capsulotomy without tears, and an intraocular lens in the correct intracapsular position at the end surgery. The ACO was measured by a clinical classification ranging from 0 to 4. In addition, ACO density was measured with the Scheimpflug device using 3 densitometry methods (area, linear, and peak). RESULTS: The study comprised 32 eyes of 32 patients. Area and linear densitometry values provided by the Scheimpflug device had a strong correlation with the values obtained by clinical classification, whereas peak densitometry values had a very weak correlation at 6 months (area densitometry: Spearman ρ = 0.78; P < .0005; linear densitometry: ρ = 0.73; P < .0005; peak densitometry ρ = 0.21; P = .2). CONCLUSION: The Scheimpflug device provided an objective measurement of ACO after cataract surgery. FINANCIAL DISCLOSURE: None of the authors has a financial or proprietary interest in any material or method mentioned.


Assuntos
Opacificação da Cápsula , Extração de Catarata , Densitometria , Idoso , Idoso de 80 Anos ou mais , Catarata , Feminino , Humanos , Implante de Lente Intraocular , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Software , Espanha
8.
J Cataract Refract Surg ; 41(4): 790-9, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25840303

RESUMO

PURPOSE: To determine astigmatic changes by vector analysis and postoperative refractive and visual outcomes after implantation of the monofocal aspheric bitoric AT Torbi 709M toric intraocular lens (IOL). SETTING: Three centers in Salzburg, Austria, and Alicante and San Sebastián, Spain. DESIGN: Prospective interventional case series. METHODS: Preoperative and postoperative visual acuity, subjective and objective refractions, and corneal radii using a topographer were examined in all patients. All patients had postoperative examinations within the first week and at 6 to 12 weeks. Astigmatic changes were evaluated using the Alpins vector method based on 3 fundamental vectors as follows: target induced astigmatism (TIA), surgically induced astigmatism (SIA), and difference vector. The various relationships between these 3 vectors were calculated, providing an extensive description of the astigmatic correction achieved. RESULTS: Eighty-eight eyes (71 patients) were included. Postoperatively, refractive cylinder was reduced significantly (P < .001), concurrent with visual improvement. The mean magnitude of the SIA vector (2.54 diopters [D] ± 1.21 [SD]) was slightly higher than the mean magnitude of the TIA vector (2.37 ± 1.15 D) at the last follow-up. The mean difference vector was 0.46 ± 0.46 D, the mean magnitude of error was 0.16 ± 0.46 D, and the mean correction index was 1.09 ± 0.21, all indicating minimal overcorrection at 3 months that remained stable during the follow-up. CONCLUSION: Implantation of the toric IOL was safe and effective for the treatment of eyes with cataract in combination with preexisting regular corneal astigmatism over a short-term follow-up. FINANCIAL DISCLOSURE: No author has a financial or proprietary interest in any material or method mentioned.


Assuntos
Astigmatismo/fisiopatologia , Astigmatismo/cirurgia , Implante de Lente Intraocular , Facoemulsificação , Adulto , Idoso , Idoso de 80 Anos ou mais , Catarata/fisiopatologia , Topografia da Córnea , Feminino , Humanos , Lentes Intraoculares , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Desenho de Prótese , Pseudofacia/fisiopatologia , Refração Ocular/fisiologia , Acuidade Visual/fisiologia
9.
J Refract Surg ; 29(3): 194-9, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23446016

RESUMO

PURPOSE: To describe the intraocular rotational stability and refractive results of the toric AT TORBI 709 M (former AT.Comfort 464 TLC) intraocular lens (IOL) (Carl Zeiss Meditec AG, Jena, Germany). METHODS: Forty-eight eyes of 32 consecutive patients with cataract and greater than 1 diopter of corneal astigmatism were included. Implantation of the toric IOL was performed after phacoemulsification. Uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), residual refractive sphere, residual keratometric and refractive cylinders, and toric IOL axis were measured before and 1, 3, and 6 months after surgery. RESULTS: Mean logMAR UDVA and CDVA improved significantly after surgery (P < .05). UDVA was 20/40 or better in 88.1% of eyes and 20/25 or better in 61.9%. CDVA was 20/40 or better in 100% of eyes and 20/25 or better in 90.2%. Mean refractive cylinder decreased significantly from -2.23 ± 1.72 before to -0.43 ± 0.53 after surgery (P < .05). Vector analysis of attempted versus achieved correction showed 100% of eyes within ± 1.00 D and 95.2% within ± 0.50 D for J and 100% of eyes were within ± 1.00 D and 95.2% within ± 0.50 D for J. Mean toric IOL axis rotation was 4.42 ± 4.31 degrees (range: 0 to 16 degrees) and 86% of the lenses rotated less than 10 degrees. CONCLUSIONS: The AT TORBI 709 M IOL has proved to be a predictable and effective device with good rotational stability for the correction of preexisting astigmatism during cataract surgery.


Assuntos
Astigmatismo/cirurgia , Implante de Lente Intraocular , Lentes Intraoculares , Facoemulsificação , Adulto , Idoso , Idoso de 80 Anos ou mais , Astigmatismo/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Desenho de Prótese , Pseudofacia/fisiopatologia , Refração Ocular/fisiologia , Resultado do Tratamento , Acuidade Visual/fisiologia
10.
J Refract Surg ; 28(10): 696-701, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23061999

RESUMO

PURPOSE: To assess astigmatic reduction and rotational stability of Rayner T-flex toric intraocular lenses (IOL) (573T and 623T; Rayner Intraocular Lenses Ltd) in a series of cataract surgery patients with corneal astigmatism >1.50 diopters (D). METHODS: This prospective, observational study included 27 eyes from 22 consecutive patients with pre-operative regular corneal astigmatism ≥1.50 D in which Rayner T-flex toric IOL implantation was performed after phacoemulsification. Uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), residual refractive sphere, residual keratometric and refractive cylinder, and deviation from attempted toric IOL axis were measured. RESULTS: Mean UDVA 3 months after surgery was 0.1042±0.1290 with 20/40 or better in 96% of eyes and 20/25 or better in 52% of eyes. Mean refractive postoperative sphere was 0.25±0.37 D and mean refractive postoperative cylinder was 0.52±0.63 D. Vector analysis of attempted versus achieved visual correction showed that 100% of eyes were within ±1.00 D and 87% of eyes were within ±0.50 D. Mean change in keratometric astigmatism was 0.54±1.33 for J(0) and -0.24±1.17 for J(45) (P>.05). Twenty-five (92.6%) eyes had IOL rotation <10°. CONCLUSIONS: Rayner T-flex toric IOL implantation is an effective and reliable option to correct preexisting astigmatism in cataract surgery.


Assuntos
Migração do Implante de Lente Intraocular , Astigmatismo/terapia , Implante de Lente Intraocular , Facoemulsificação , Refração Ocular/fisiologia , Rotação , Acuidade Visual/fisiologia , Idoso , Idoso de 80 Anos ou mais , Astigmatismo/complicações , Astigmatismo/fisiopatologia , Catarata/complicações , Feminino , Humanos , Lentes Intraoculares , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...