Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Clin Transplant ; 12(1): 56-64, 1998 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-9541424

RESUMO

We have reported that a decline in glucose disappearance rate (kG) in pancreas transplant recipients is associated with pancreatic rejection. The purpose of this study was to determine test-retest reliability of kG monitoring and to establish the kG criteria for diagnosing abnormal graft function. Six healthy non-diabetic volunteers and 14 stable pancreas recipients underwent 2 intravenous glucose tolerance tests 7 d apart. All kG values in non-diabetic volunteers had < 15% variation between the two determinations (r = 0.96, P < or = 0.0006). Similarly, 13/14 recipients experienced < 20% variation in kG with one patients experiencing a 23% variation (r = 0.90, P < or = 0.0001). Using a 20% change from baseline as the reference value, we monitored 28 pancreas recipients for 2-36 months post-transplant. Of 253 kG values, 160 (64%) did not exceed the 20% change from baseline, 65 (26%) declined > 20% and 28 (11%) increased > 20%. Of 160 stable kG values, 154 (96%) were associated with normal graft function while 6 (4%) occurred in the context of rejection. Of 65 kG values declining by > or = 20%, 47 (72%) accurately identified acute rejections diagnosed by biopsy (70%) or response to treatment (30%), 12 (19%) were associated with identifiable causes of increased insulin resistance and only in 6 (9%) cases a cause for the decline was unidentifiable. The kG values with > 20% rise from baseline were, in 15%, associated with identifiable causes of decreased insulin resistance. The sensitivity of the kG as a marker for rejection was 88.7%, specificity 91%, positive predictive value 72.3%, negative predictive value 96.8%, and accuracy 90.5%. These data confirm that a > 20% deterioration of glucose disappearance rate is associated with pancreas allograft rejection, and confirms the utility of kG monitoring in clinical follow-up of pancreas transplant recipients.


Assuntos
Glicemia/metabolismo , Rejeição de Enxerto/diagnóstico , Transplante de Pâncreas/fisiologia , Adulto , Diabetes Mellitus Tipo 1/terapia , Feminino , Teste de Tolerância a Glucose , Humanos , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade , Transplante Homólogo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...