Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 30
Filtrar
1.
J Am Vet Med Assoc ; : 1-9, 2024 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-38599232

RESUMO

This report describes a comprehensive framework for applying artificial intelligence (AI) in veterinary medicine. Our framework draws on existing research on AI implementation in human medicine and addresses the challenges of limited technology expertise and the need for scalability. The critical components of this framework include assembling a diverse team of experts in AI, promoting a foundational understanding of AI among veterinary professionals, identifying relevant use cases and objectives, ensuring data quality and availability, creating an effective implementation plan, providing team training, fostering collaboration, considering ethical and legal obligations, integrating AI into existing workflows, monitoring and evaluating performance, managing change effectively, and staying up-to-date with technological advancements. Incorporating AI into veterinary medicine requires addressing unique ethical and legal considerations, including data privacy, owner consent, and the impact of AI outputs on decision-making. Effective change management principles aid in avoiding disruptions and building trust in AI technology. Furthermore, continuous evaluation of AI's relevance in veterinary practice ensures that the benefits of AI translate into meaningful improvements in patient care.

2.
Med Phys ; 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38626571

RESUMO

Since 2010, there has been little published data on the state of equipment and infrastructure in veterinary radiation oncology clinical practice. These data are important not only to identify the status and use of technology within the veterinary radiation oncology community but also to help identify the extent of medical physics support. The purpose of our study is to report findings from a survey of veterinary radiation oncologists in the USA, Canada, and select centers outside of North America in 2022. A 40-question survey covering topics such as type of radiotherapy equipment, techniques offered, treatment planning systems and dose calculation algorithms, special techniques, board-certified radiation oncologists and residents, and extent of medical physics support was distributed through an online survey tool. Results from 40 veterinary radiation oncology institutions, with equipment explicitly used for veterinary care, suggest that the current state of practice is not dissimilar to what currently exists in human radiation oncology facilities; techniques and technologies commonly employed include flattening filter-free mode megavoltage beams, volumetric arc therapy, daily cone-beam computed tomography, image-guided radiation therapy, and sophisticated dose calculation algorithms. These findings suggest the need for modern radiation oncology acceptance testing, commissioning, and quality assurance programs within the veterinary community. The increase in veterinary radiation oncology residency positions and increasing sophistication of equipment suggests that increased levels of standardized medical physics support would benefit the veterinary radiation oncology community.

3.
Vet Radiol Ultrasound ; 64(5): 890-903, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37394240

RESUMO

This retrospective analytical observational cohort study aimed to model and predict the classification of feline intestinal diseases from segmentations of a transverse section from small intestine ultrasound (US) image, complete blood count (CBC), and serum biochemical profile data using a variety of machine-learning approaches. In 149 cats from three institutions, images were obtained from cats with biopsy-confirmed small cell epitheliotropic lymphoma (lymphoma), inflammatory bowel disease (IBD), no pathology ("healthy"), and other conditions (warrant a biopsy for further diagnosis). CBC, blood serum chemistry, small intestinal ultrasound, and small intestinal biopsy were obtained within a 2-week interval. CBC and serum biomarkers and radiomic features were combined for modeling. Four classification schemes were investigated: (1) normal versus abnormal; (2) warranting or not warranting a biopsy; (3) lymphoma, IBD, healthy, or other conditions; and (4) lymphoma, IBD, or other conditions. Two feature selection methods were used to identify the top 3, 5, 10, and 20 features, and six machine learning models were trained. The average (95% CI) performance of models for all combinations of features, numbers of features, and types of classifiers was 0.886 (0.871-0.912) for Model 1 (normal vs. abnormal), 0.751 (0.735-0.818) for Model 2 (biopsy vs. no biopsy), 0.504 (0.450-0.556) for Model 3 (lymphoma, IBD, healthy, or other), and 0.531 (0.426-0.589), for Model 4 (lymphoma, IBD, or other). Our findings suggest model accuracies above 0.85 can be achieved in Model 1 and 2, and that including CBC and biochemistry data with US radiomics data did not significantly improve accuracy in our models.


Assuntos
Doenças do Gato , Doenças Inflamatórias Intestinais , Linfoma , Animais , Gatos , Biomarcadores , Contagem de Células Sanguíneas/veterinária , Doenças do Gato/diagnóstico por imagem , Doenças Inflamatórias Intestinais/diagnóstico por imagem , Doenças Inflamatórias Intestinais/veterinária , Linfoma/veterinária , Aprendizado de Máquina , Estudos Retrospectivos , Soro
4.
Vet Comp Oncol ; 21(3): 378-390, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37068761

RESUMO

Palliative-intent radiation therapy can alleviate pain and clinical signs in dogs with cancer, but optimal fractionation scheme is unknown. The objective of this retrospective case series is to evaluate clinical benefit, objective response, adverse effects, and outcomes in 108 dogs with macroscopic solid tumours treated with a cyclical "QUAD" hypofractionated palliative-intent radiation therapy protocol. Median QUAD dose was 14 Gy (14-16 Gy). Median total dose was 28 Gy (14-48 Gy). Clinical benefit rate was 93%, with median onset of subjective palliation 21 days after the first QUAD, lasting a median of 134 days. Tumour volumetric objective response was assessed with CT prior to the third QUAD in 36 dogs, with stable disease in 24 dogs (67%) and partial response in 9 dogs (25%). Sinonasal and oral were the most common tumour locations in 32 and 30 dogs, respectively. Median progression-free survival was 153 days (95% CI 114-200). Median overall survival was 212 days (95% CI 152-259). Number of QUAD cycles completed, clinical benefit achieved, anti-inflammatory received, total radiation dose, time to maximum clinical benefit, and response duration were positively associated with progression-free and overall survival. Acute toxicities were observed in 15 dogs (14%) with 3 high-grade (grade 3) toxicities (3%). Low-grade (grade 1 and 2) late skin and ocular toxicities were observed in 31 dogs (29%), predominantly leukotrichia, alopecia, keratoconjunctivitis sicca, and cataracts. This report demonstrates that QUAD radiation is an alternative protocol to be considered for palliation of dogs with inoperable or advanced stage solid tumours.


Assuntos
Doenças do Cão , Neoplasias , Cães , Animais , Estudos Retrospectivos , Doenças do Cão/patologia , Neoplasias/radioterapia , Neoplasias/veterinária , Hipofracionamento da Dose de Radiação , Fracionamento da Dose de Radiação
5.
Animals (Basel) ; 13(5)2023 Feb 24.
Artigo em Inglês | MEDLINE | ID: mdl-36899684

RESUMO

Proximal sesamoid bone (PSB) fracture is the leading cause of fatal musculoskeletal injury in Thoroughbred racehorses in Hong Kong and the US. Efforts are underway to investigate diagnostic modalities that could help identify racehorses at increased risk of fracture; however, features associated with PSB fracture risk are still poorly understood. The objectives of this study were to (1) investigate third metacarpal (MC3) and PSB density and mineral content using dual-energy X-ray absorptiometry (DXA), computed tomography (CT), Raman spectroscopy, and ash fraction measurements, and (2) investigate PSB quality and metacarpophalangeal joint (MCPJ) pathology using Raman spectroscopy and CT. Forelimbs were collected from 29 Thoroughbred racehorse cadavers (n = 14 PSB fracture, n = 15 control) for DXA and CT imaging, and PSBs were sectioned for Raman spectroscopy and ash fraction measurements. Bone mineral density (BMD) was greater in MC3 condyles and PSBs of horses with more high-speed furlongs. MCPJ pathology, including palmar osteochondral disease (POD), MC3 condylar sclerosis, and MC3 subchondral lysis were greater in horses with more high-speed furlongs. There were no differences in BMD or Raman parameters between fracture and control groups; however, Raman spectroscopy and ash fraction measurements revealed regional differences in PSB BMD and tissue composition. Many parameters, including MC3 and PSB bone mineral density, were strongly correlated with total high-speed furlongs.

6.
Vet Radiol Ultrasound ; 64(1): 131-139, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36049073

RESUMO

Measurements of intestinal wall thicknesses from ultrasound imaging (US) are routinely used to support diagnoses of intestinal disorders in cats, however published studies describing observer agreement are currently lacking. The aim of this retrospective, observer agreement study was to quantify inter- and intraobserver repeatability and agreement in the measurement of intestinal wall layer thicknesses and the segmentation of transverse sections of small intestines in US images of 20 cats. Intestinal wall layer thickness measurements of the mucosa, submucosa, muscularis, serosa layer, and total thickness of these layers were performed on five cats with small cell epitheliotropic lymphoma, five with inflammatory bowel disease, and 10 with other conditions. Thickness measurements and the segmentation encompassing the serosa layer were obtained from five observers four times non-sequentially. The average standard deviation in thickness measurements (95% confidence interval) in the mucosa, submucosa, muscularis, serosa, and total thickness were 0.35 (0.07-0.95), 0.24 (0.07-0.52), 0.22 (0.06-0.49), 0.20 (0.05-0.49), and 0.57 (0.11-1.60) mm, respectively. The average intraclass correlation coefficients, which estimates the degree of consistency in thickness measurements and segmentation areas for each observer, ranged from 0.355 to 0.870 and 0.850 to 0.993, respectively. The interclass correlation coefficient, which estimates the degree of consistency when measuring a thickness or segmentation area over all observers ranged from 0.115 to 0.753, and 0.811 to 0.902, respectively. The overall average Dice Coefficient, which estimates the extent of overlap of the segmentations for all observers was 0.957 (0.933 to 0.972). Our results suggest segmentations of small intestines have a higher interobserver agreement than measurements of intestinal wall thicknesses.


Assuntos
Intestino Delgado , Intestinos , Gatos , Animais , Estudos Retrospectivos , Intestinos/diagnóstico por imagem , Intestino Delgado/diagnóstico por imagem , Intestino Delgado/patologia , Ultrassonografia/veterinária , Ultrassonografia/métodos , Variações Dependentes do Observador , Reprodutibilidade dos Testes
7.
Vet Radiol Ultrasound ; 63 Suppl 1: 828-839, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36514226

RESUMO

Radiomics, or quantitative image analysis from radiographic image data, borrows the suffix from other emerging -omics fields of study, such as genomics, proteomics, and metabolomics. This report provides an overview of the general principles of how radiomic features are computed, describes major types of morphological, first order, and texture features, and the applications, challenges, and opportunities of radiomics as applied in veterinary medicine. Some advantages radiomics has over traditional semantic radiological features include standardized methodology in computing semantic features, the ability to compute features in multi-dimensional images, their newfound associations with genomic and pathological abnormalities, and the number of perceptible and imperceptible features available for regression or classification modeling. Some challenges in deploying radiomics in a clinical setting include sensitivity to image acquisition settings and image artifacts, pre- and post-image reconstruction and calculation settings, variability in feature estimates stemming from inter- and intra-observer contouring errors, and challenges with software and data harmonization and generalizability of findings given the challenges of small sample size and patient selection bias in veterinary medicine. Despite this, radiomics has enormous potential in patient-centric diagnostics, prognosis, and theragnostics. Fully leveraging the utility of radiomics in veterinary medicine will require inter-institutional collaborations, data harmonization, and data sharing strategies amongst institutions, transparent and robust model development, and multi-disciplinary efforts within and outside the veterinary medical imaging community.


Assuntos
Processamento de Imagem Assistida por Computador , Radiologia , Animais , Processamento de Imagem Assistida por Computador/métodos , Diagnóstico por Imagem , Software
8.
Vet Radiol Ultrasound ; 63 Suppl 1: 817-827, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36514230

RESUMO

The prevalence and pervasiveness of artificial intelligence (AI) with medical images in veterinary and human medicine is rapidly increasing. This article provides essential definitions of AI with medical images with a focus on veterinary radiology. Machine learning methods common in medical image analysis are compared, and a detailed description of convolutional neural networks commonly used in deep learning classification and regression models is provided. A brief introduction to natural language processing (NLP) and its utility in machine learning is also provided. NLP can economize the creation of "truth-data" needed when training AI systems for both diagnostic radiology and radiation oncology applications. The goal of this publication is to provide veterinarians, veterinary radiologists, and radiation oncologists the necessary background needed to understand and comprehend AI-focused research projects and publications.


Assuntos
Aprendizado Profundo , Radiologia , Animais , Humanos , Inteligência Artificial , Diagnóstico por Imagem , Aprendizado de Máquina
9.
Vet Radiol Ultrasound ; 63 Suppl 1: 903-912, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36514233

RESUMO

Veterinary radiation oncology regularly deploys sophisticated contouring, image registration, and treatment planning optimization software for patient care. Over the past decade, advances in computing power and the rapid development of neural networks, open-source software packages, and data science have been realized and resulted in new research and clinical applications of artificial intelligent (AI) systems in radiation oncology. These technologies differ from conventional software in their level of complexity and ability to learn from representative and local data. We provide clinical and research application examples of AI in human radiation oncology and their potential applications in veterinary medicine throughout the patient's care-path: from treatment simulation, deformable registration, auto-segmentation, automated treatment planning and plan selection, quality assurance, adaptive radiotherapy, and outcomes modeling. These technologies have the potential to offer significant time and cost savings in the veterinary setting; however, since the range of usefulness of these technologies have not been well studied nor understood, care must be taken if adopting AI technologies in clinical practice. Over the next several years, some practical and realizable applications of AI in veterinary radiation oncology include automated segmentation of normal tissues and tumor volumes, deformable registration, multi-criteria plan optimization, and adaptive radiotherapy. Keys in achieving success in adopting AI in veterinary radiation oncology include: establishing "truth-data"; data harmonization; multi-institutional data and collaborations; standardized dose reporting and taxonomy; adopting an open access philosophy, data collection and curation; open-source algorithm development; and transparent and platform-independent code development.


Assuntos
Radioterapia (Especialidade) , Humanos , Animais , Inteligência Artificial , Algoritmos
10.
Animals (Basel) ; 12(21)2022 Nov 04.
Artigo em Inglês | MEDLINE | ID: mdl-36359157

RESUMO

Proximal sesamoid bone (PSB) fractures are the most common musculoskeletal injury in race-horses. X-ray CT imaging can detect expressed radiological features in horses that experienced catastrophic fractures. Our objective was to assess whether expressed radiomic features in the PSBs of 50 horses can be used to develop machine learning models for predicting PSB fractures. The µCTs of intact contralateral PSBs from 50 horses, 30 of which suffered catastrophic fractures, and 20 controls were studied. From the 129 intact µCT images of PSBs, 102 radiomic features were computed using a variety of voxel resampling dimensions. Decision Trees and Wrapper methods were used to identify the 20 top expressed features, and six machine learning algorithms were developed to model the risk of fracture. The accuracy of all machine learning models ranged from 0.643 to 0.903 with an average of 0.754. On average, Support Vector Machine, Random Forest (RUS Boost), and Log-regression models had higher performance than K-means Nearest Neighbor, Neural Network, and Random Forest (Bagged Trees) models. Model accuracy peaked at 0.5 mm and decreased substantially when the resampling resolution was greater than or equal to 1 mm. We find that, for this in vitro dataset, it is possible to differentiate between unfractured PSBs from case and control horses using µCT images. It may be possible to extend these findings to the assessment of fracture risk in standing horses.

11.
Vet Surg ; 51(6): 952-962, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35672916

RESUMO

OBJECTIVE: To determine whether proximal sesamoid bone (PSB) microdamage and fracture toughness differ between Thoroughbred racehorses sustaining PSB fracture and controls. STUDY DESIGN: Cadaveric case-control. ANIMALS: Twenty-four Thoroughbred racehorses (n = 12 PSB fracture, n = 12 control). METHODS: Proximal sesamoid bones were dissected, and gross pathological changes and morphological measurements were documented. High-speed exercise history data were evaluated. Microdamage was assessed in fracture, fracture-contralateral limb (FXCL) and control PSBs using whole bone lead uranyl acetate (LUA) staining with micro-CT imaging or basic fuchsin histological analysis. Fracture toughness mechanical testing was carried out in 3-point-bending of microbeams created from PSB flexor cortices. Data were analyzed using ordinal logistic and linear regression models. RESULTS: Microdamage was detected most commonly in the articular subchondral region of PSBs via LUA micro-CT and basic fuchsin histology. There were no differences in microdamage between FXCL and control PSBs. Fracture toughness values were similar for FXCL (1.31 MPa√m) and control (1.35 MPa√m) PSBs. Exercise histories were similar except that horses sustaining fracture spent a greater percentage of their careers in rest weeks. CONCLUSION: Microdamage was detected in the articular region of PSBs but was not greater in horses sustaining catastrophic PSB fracture. Fracture toughness of PSB flexor cortices did not differ between FXCL and control PSBs. CLINICAL SIGNIFICANCE: Although uncommon, microdamage is localized to the articular region of Thoroughbred racehorse PSBs. Catastrophic PSB failure is not associated with lower PSB flexor cortex fracture toughness.


Assuntos
Fraturas Ósseas , Doenças dos Cavalos , Ossos Sesamoides , Animais , Estudos de Casos e Controles , Fraturas Ósseas/patologia , Fraturas Ósseas/veterinária , Doenças dos Cavalos/patologia , Cavalos , Humanos , Ossos Sesamoides/patologia , Microtomografia por Raio-X/veterinária
12.
Animals (Basel) ; 12(7)2022 Mar 31.
Artigo em Inglês | MEDLINE | ID: mdl-35405875

RESUMO

Teat-end health assessments are crucial to maintain milk quality and dairy cow health. One approach to automate teat-end health assessments is by using a convolutional neural network to classify the magnitude of teat-end alterations based on digital images. This approach has been demonstrated as feasible with GoogLeNet but there remains a number of challenges, such as low performance and comparing performance with different ImageNet models. In this paper, we present a separable confident transductive learning (SCTL) model to improve the performance of teat-end image classification. First, we propose a separation loss to ameliorate the inter-class dispersion. Second, we generate high confident pseudo labels to optimize the network. We further employ transductive learning to narrow the gap between training and test datasets with categorical maximum mean discrepancy loss. Experimental results demonstrate that the proposed SCTL model consistently achieves higher accuracy across all seventeen different ImageNet models when compared with retraining of original approaches.

13.
J Am Vet Med Assoc ; 260(8): 819-824, 2022 03 30.
Artigo em Inglês | MEDLINE | ID: mdl-35358065

RESUMO

Artificial intelligence (AI) is a branch of computer science in which computer systems are designed to perform tasks that mimic human intelligence. Today, AI is reshaping day-to-day life and has numerous emerging medical applications poised to profoundly reshape the practice of veterinary medicine. In this Currents in One Health, we discuss the essential elements of AI for veterinary practitioners with the aim to help them make informed decisions in applying AI technologies into their practices. Veterinarians will play an integral role in ensuring the appropriate uses and good curation of data. The expertise of veterinary professionals will be vital to ensuring good data and, subsequently, AI that meets the needs of the profession. Readers interested in an in-depth description of AI and veterinary medicine are invited to explore a complementary manuscript of this Currents in One Health available in the May 2022 issue of the American Journal of Veterinary Research.


Assuntos
Inteligência Artificial , Médicos Veterinários , Animais , Humanos
14.
Am J Vet Res ; 83(5): 385-392, 2022 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-35353711

RESUMO

Veterinary medicine is a broad and growing discipline that includes topics such as companion animal health, population medicine and zoonotic diseases, and agriculture. In this article, we provide insight on how artificial intelligence works and how it is currently applied in veterinary medicine. We also discuss its potential in veterinary medicine. Given the rapid pace of research and commercial product developments in this area, the next several years will pose challenges to understanding, interpreting, and adopting this powerful and evolving technology. Artificial intelligence has the potential to enable veterinarians to perform tasks more efficiently while providing new insights for the management and treatment of disorders. It is our hope that this will translate to better quality of life for animals and those who care for them.


Assuntos
Médicos Veterinários , Medicina Veterinária , Animais , Inteligência Artificial , Humanos , Qualidade de Vida
16.
Equine Vet J ; 53(2): 277-286, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32654167

RESUMO

BACKGROUND: Proximal sesamoid bone (PSB) fractures are the most common fatal musculoskeletal injury in North American racehorses. Computed tomography has the potential to detect morphological changes in bone structure but can be challenging to analyse reliably and quantitatively. OBJECTIVES: To develop a radiomics platform that allows the comparison of features from micro-CTs (µCT) of PSBs in horses that sustained catastrophic fractures with horses that did not. To compare features calculated with a radiomics approach with features calculated from a previously published study that used quantitative µCT in the same specimens. STUDY DESIGN: Retrospective study of cadaver specimens of µCT images of PSBs using prospectively applied radiomics. METHODS: Radiomics features were computed on standardised CT datasets to benchmark the software. Features from µCT images of PSBs from eight horses that sustained PSB fracture and eight controls were computed using the contralateral, intact forelimb from horses sustaining PSB fracture (cases, n = 19) and all available forelimbs for controls (n = 30). Two-hundred and fifteen radiomic features were calculated, and similar or comparable features were compared with those reported in a previous study that used the same specimens. RESULTS: Morphologic features computed with the radiomics approach, such as volume, minor axis dimensions and anisotropy were highly correlated with previously published data. A high number of imperceptible radiomic features, such as entropy, coarseness and histogram features were also found to be significantly different (P < .01). The extent of the differences in image features for the cases and controls PSBs depends on radiomic calculation settings. MAIN LIMITATIONS: Only datasets obtained from cadaver specimens were included in the study. CONCLUSIONS: A radiomics approach for analysing µCT images of PSBs was able to identify and reproduce differences in image features in cases and controls. Furthermore, radiomics revealed many more imperceptible image features between cases and control PSBs.


Assuntos
Fraturas Ósseas , Doenças dos Cavalos , Ossos Sesamoides , Animais , Benchmarking , Membro Anterior/diagnóstico por imagem , Fraturas Ósseas/diagnóstico por imagem , Fraturas Ósseas/veterinária , Doenças dos Cavalos/diagnóstico por imagem , Cavalos , Estudos Retrospectivos , Ossos Sesamoides/diagnóstico por imagem
18.
J Appl Clin Med Phys ; 16(5): 159­166, 2015 09 08.
Artigo em Inglês | MEDLINE | ID: mdl-26699296

RESUMO

Permanent implant of sealed radioactive sources is an effective technique for treating cancer. Typically, the radioactive sources are implanted in and near the disease, depositing radiation absorbed dose locally over several months. There may be instances where these patients must undergo unrelated surgical procedures when the radioactive material remains active enough to pose risks. This work explores these risks, discusses strategies to mitigate those risks, and describes a case study for a permanent iodine-125 (I-125) prostate brachytherapy implant patient who developed colorectal cancer and required surgery six months after brachytherapy. The first consideration is identifying the radiological risk to the patient and staff before, during, and after the surgical procedure. The second is identifying the risk the surgical procedure may have on the efficacy of the brachytherapy implant. Finally, there are considerations for controlling the radioactive substances from a regulatory perspective. After these risks are defined, strategies to mitigate those risks are considered. We summarize this experience with some guidelines: If the surgical procedure is near (e.g., within 5-10 cm of) the implant; and, the surgical intervention may dislodge sources enough to compromise treatment or introduces radiation safety risks; and, the radioactivity has not sufficiently decayed to background levels; and, the surgery cannot be postponed, then a detailed analysis of risk is advised.


Assuntos
Radioisótopos do Iodo/uso terapêutico , Corpo Clínico , Prostatectomia , Neoplasias da Próstata/radioterapia , Lesões por Radiação/prevenção & controle , Monitoramento de Radiação , Proteção Radiológica/métodos , Braquiterapia , Humanos , Masculino , Prognóstico , Neoplasias da Próstata/cirurgia , Próteses e Implantes , Radiometria , Dosagem Radioterapêutica
19.
Radiat Oncol ; 9: 50, 2014 Feb 10.
Artigo em Inglês | MEDLINE | ID: mdl-24512755

RESUMO

BACKGROUND: The purpose of this study is to evaluate the clinical impact of using deformable registration in tumor volume definition between separately acquired PET/CT and planning CT images. METHODS: Ten lung and 10 head and neck cancer patients were retrospectively selected. PET/CT images were registered with planning CT scans using commercially available software. Radiation oncologists defined two sets of gross tumor volumes based on either rigidly or deformably registered PET/CT images, and properties of these volumes were then compared. RESULTS: The average displacement between rigid and deformable gross tumor volumes was 1.8 mm (0.7 mm) with a standard deviation of 1.0 mm (0.6 mm) for the head and neck (lung) cancer subjects. The Dice similarity coefficients ranged from 0.76-0.92 and 0.76-0.97 for the head and neck and lung subjects, respectively, indicating conformity. All gross tumor volumes received at least 95% of the prescribed dose to 99% of their volume. Differences in the mean radiation dose delivered to the gross tumor volumes were at most 2%. Differences in the fraction of the tumor volumes receiving 100% of the radiation dose were at most 5%. CONCLUSIONS: The study revealed limitations in the commercial software used to perform deformable registration. Unless significant anatomical differences between PET/CT and planning CT images are present, deformable registration was shown to be of marginal value when delineating gross tumor volumes.


Assuntos
Carcinoma Pulmonar de Células não Pequenas/radioterapia , Neoplasias de Cabeça e Pescoço/radioterapia , Neoplasias Pulmonares/radioterapia , Tomografia por Emissão de Pósitrons , Planejamento da Radioterapia Assistida por Computador/métodos , Tomografia Computadorizada por Raios X , Idoso , Carcinoma Pulmonar de Células não Pequenas/patologia , Neoplasias de Cabeça e Pescoço/patologia , Humanos , Processamento de Imagem Assistida por Computador/métodos , Neoplasias Pulmonares/patologia , Pessoa de Meia-Idade , Imagem Multimodal , Radiometria , Dosagem Radioterapêutica , Estudos Retrospectivos , Software , Carga Tumoral
20.
Med Phys ; 39(4): 2061-8, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22482627

RESUMO

PURPOSE: To investigate the effects of brachytherapy seed size on the quality of x-ray computed tomography (CT), ultrasound (US), and magnetic resonance (MR) images and seed localization through comparison of the 6711 and 9011 (125)I sources. METHODS: For CT images, an acrylic phantom mimicking a clinical implantation plan and embedded with low contrast regions of interest (ROIs) was designed for both the 0.774 mm diameter 6711 (standard) and the 0.508 mm diameter 9011 (thin) seed models (Oncura, Inc., and GE Healthcare, Arlington Heights, IL). Image quality metrics were assessed using the standard deviation of ROIs between the seeds and the contrast to noise ratio (CNR) within the low contrast ROIs. For US images, water phantoms with both single and multiseed arrangements were constructed for both seed sizes. For MR images, both seeds were implanted into a porcine gel and imaged with pelvic imaging protocols. The standard deviation of ROIs and CNR values were used as metrics of artifact quantification. Seed localization within the CT images was assessed using the automated seed finder in a commercial brachytherapy treatment planning system. The number of erroneous seed placements and the average and maximum error in seed placements were recorded as metrics of the localization accuracy. RESULTS: With the thin seeds, CT image noise was reduced from 48.5 ± 0.2 to 32.0 ± 0.2 HU and CNR improved by a median value of 74% when compared with the standard seeds. Ultrasound image noise was measured at 50.3 ± 17.1 dB for the thin seed images and 50.0 ± 19.8 dB for the standard seed images, and artifacts directly behind the seeds were smaller and less prominent with the thin seed model. For MR images, CNR of the standard seeds reduced on average 17% when using the thin seeds for all different imaging sequences and seed orientations, but these differences are not appreciable. Automated seed localization required an average (±SD) of 7.0 ± 3.5 manual corrections in seed positions for the thin seed scans and 3.0 ± 1.2 manual corrections in seed positions for the standard seed scans. The average error in seed placement was 1.2 mm for both seed types and the maximum error in seed placement was 2.1 mm for the thin seed scans and 1.8 mm for the standard seed scans. CONCLUSIONS: The 9011 thin seeds yielded significantly improved image quality for CT and US images but no significant differences in MR image quality.


Assuntos
Artefatos , Braquiterapia/instrumentação , Diagnóstico por Imagem/métodos , Neoplasias da Próstata/diagnóstico , Neoplasias da Próstata/radioterapia , Próteses e Implantes , Radioterapia Guiada por Imagem/métodos , Humanos , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...