Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 29
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Oper Dent ; 2024 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-38632866

RESUMO

OBJECTIVES: This study evaluated the influence of hydrogen peroxide (HP) with or without titanium dioxide nanotubes (TiO2) associated with violet LED (VL) regarding: a) the temperature change in the pulp chamber and facial surface; b) the decomposition of HP; and c) the cytotoxicity of the gels on pulp cells. METHODS AND MATERIALS: The experimental groups were: HP35 (35% HP/Whiteness HP, FGM); HP35+VL; HP35T (HP35+TiO2); HP35T+VL; HP7 (7.5% HP/White Class 7.5%, FGM); HP7+VL; HP7T (HP7+TiO2); and HP7T+VL. TiO2 was incorporated into the bleaching gels at 1%. Eighty bovine incisors were evaluated to determine temperature change in 8 experimental groups (n=10/group). A k-type thermocouple was used to evaluate the temperatures of the facial surface and in the pulp chamber, achieved by enabling endodontic access to the palatal surface, throughout the 30-minute session. HP decomposition (n=3) of gels was evaluated by using an automatic potentiometric titrator at the initial and 30-minute time points. Trans-enamel and trans-dentinal cell viability were assessed with a pulp chamber device as well as enamel and dentin discs (n=6), and the treatment extracts (culture medium + diffused components) were collected and applied to MDPC-23 odontoblast cells to evaluate cell viability according to the MTT test. RESULTS: A temperature increase in the pulp chamber was observed in the presence of VL at 30 minutes (p<0.05) (Mann-Whitney test). Also at 30 minutes, HP35 showed greater decomposition in the presence of VL rather than in its absence (p<0.05) (mixed linear models and the Tukey-Kramer test). HP7 provided greater cell viability than the groups treated with HP35 (p<0.05) (generalized linear models test). Cell viability was significantly lower for HP7 in the presence of VL (p<0.05). CONCLUSION: Pulpal temperature increased with VL (maximum of 1.9°C), but did not exceed the critical limit to cause pulp damage. Less concentrated HP resulted in higher cell viability, even when associated with VL.

2.
Oper Dent ; 49(2): 222-230, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38349820

RESUMO

The aim of this study was to evaluate the push-out bond strength and the failure mode of single adjustable posts (SPLENDOR SAP), anatomical posts (AP), or computer-aided design/computer-aided manufacturing (CAD-CAM) posts cemented to flared root canal dentin with self-adhesive dual-cure resin cement. Thirty single-rooted premolars received endodontic treatment with gutta-percha and a calcium hydroxide-based endodontic cement. After 24 hours, the canal spaces were enlarged with burs. The tooth specimens were divided equally into three groups (n=10), according to the glass fiber post (GFP) system: AP-prefabricated GFP (Reforpost #2, Angelus) was relined with composite resin (Filtek Z350 XT, 3M ESPE); SPLENDOR SAP-GFP was used with a glass fiber sleeve to adjust the adaptation (Splendor SAP, Angelus); and CAD-CAM-a resin pattern was obtained and scanned to produce a CAD-CAM GFP (Fiber CAD Lab, Angelus) milled using a subtractive technique. The three GFP systems were cemented with self-adhesive resin cement (Rely X U200, 3M ESPE). The roots were fixed to an acrylic resin plate used to section them into specimens of cervical, middle, and apical thirds. Then, the slices were attached to a universal testing machine to perform the push- out test at a speed of 0.5 mm/min and a load of 50 Kgf. The posttest specimens were examined under a stereoscopic microscope to evaluate the failure mode. The bond strength variable was analyzed using a generalized linear model, following a split-plot design. Failure mode analysis was performed using Fisher exact test. The significance level adopted was 5%. There was no significant difference among the GFP systems or among the thirds, in terms of bond strength (p>0.05), nor was there any significant association between the systems and the failure mode (p>0.05). Most specimens presented mixed or adhesive failure between resin cement and dentin. It was concluded that the bond strength to flared root dentin was not influenced by the GFP system or the root third.


Assuntos
Colagem Dentária , Técnica para Retentor Intrarradicular , Cimentos de Resina/uso terapêutico , Colagem Dentária/métodos , Cavidade Pulpar , Cimentos Dentários , Vidro , Teste de Materiais , Dentina
3.
Oper Dent ; 49(1): 52-64, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-38019213

RESUMO

The present study aimed to evaluate the influence of application mode on the short-term microshear bond strength longevity of self-etching and universal adhesive systems to enamel, the failure mode, and the resulting enamel surface micromorphology. Ninety enamel surfaces were obtained from sound third molars, planed, and randomly assigned to nine groups, according to the application mode and the adhesive system (n=10). There were three primer application modes: according to the manufacturer's recommended application time (control), using double the application time recommended for the primer and selective enamel etching. The adhesive systems used were: Clearfil SE Bond (Kuraray), FL-Bond II (SHOFU), and Futurabond U (Voco). At least two resin-bonded composite cylinders (Grandioso Light Flow, Voco) were placed on each enamel surface, and then evaluated for microshear bond strength at 24 hours and 180 days of storage in solution body fluid (SBF) at pH 7.4. Failure modes were evaluated with a stereoscopic microscope at 20× magnification. A micromorphological analysis of the enamel surface was performed under a scanning electron microscope at 5000× magnification before and after the treatments. Mixed models for repeated measures over time showed significant interaction among application modes, adhesive systems, and time periods (p=0.0331). The bond strength of FL-Bond II adhesive to enamel observed after performing selective enamel etching was significantly higher than that observed after applying the control treatment (p=0.0010) at both 24 hours and 180 days. However, no significant difference was observed between the application of this same adhesive at double the time recommended by the manufacturer and the other two application modes (p>0.05). There was also no significant difference in the microshear bond strength for the enamel treatments applied using Clearfil SE Bond and Futurabond U (p>0.05). A significant reduction in bond strength to enamel was observed at the 180-day storage time for all the adhesive systems when selective enamel etching was performed (p<0.0001). No significant association was observed between the adhesive system failure mode and the enamel treatments (p=0.1402 and p=0.7590 for 24 hours and 180 days, respectively). The most prevalent failure was the adhesive type.


Assuntos
Colagem Dentária , Cimentos Dentários , Cimentos Dentários/química , Colagem Dentária/métodos , Condicionamento Ácido do Dente/métodos , Resinas Compostas/química , Cimentos de Resina/uso terapêutico , Cimentos de Resina/química , Esmalte Dentário , Teste de Materiais , Resistência ao Cisalhamento , Adesivos Dentinários/química
4.
Oper Dent ; 48(6): 720-731, 2023 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-37881067

RESUMO

OBJECTIVE: To evaluate the effects of commercial mouth rinses on color, roughness, sorption (SR), and solubility (SL) of resin composites. METHODS AND MATERIALS: Disc-shaped specimens (stage I: 6 mm × 2 mm; stage II: 10 mm × 1.5 mm) were made from the following resin composites (n=10): conventional nanofilled (Filtek Z350XT, 3M Oral Care), conventional nanohybrid (Luna, SDI), bulk-fill nanofilled (Filtek One Bulk-Fill, 3M Oral Care), and bulk-fill nanohybrid (Aura Bulk-Fill, SDI) exposed to distilled water (control), blue mouth rinse without alcohol (Colgate Total 12 Clean Mint, Colgate-Palmolive), or blue mouth rinse with alcohol and essential oil (Listerine Tartar Control, Johnson & Johnson). In stage I, tests were performed at the baseline, and after the immersion in solution time points to evaluate coordinates of the CIEL*a*b* system (ΔL*, Δa*, Δb*), general color change (ΔEab, ΔE00, and ΔSGU), and surface roughness (Ra). In stage II, SR and SL were evaluated (ISO 4049:2019) after immersion in the solutions for 7 days. The results were evaluated by generalized linear models (Ra, SR), Kruskal-Wallis, and Dunn tests (color, SL), with α = 0.05. RESULTS: There were no significative differences for Ra between the solutions. Both mouth rinses promoted significantly negative ΔL* (Luna), Δa* (Filtek One Bulk-fill), and Δb* (all materials except conventional nanofilled resin composite). Mouth rinse without alcohol promoted significantly negative Δa* on all resin composites tested. Both mouth rinses promoted higher ΔEab and ΔE00 for bulk-fill resin composites compared to control. Mouth rinse with alcohol caused higher ΔSGU for bulk-fill nanofilled resin composite. It also promoted greater SR in all the resin composites compared with mouth rinse without alcohol and higher SR in nanohybrid resin composites compared with control. Both mouth rinses promoted higher SL values in Luna and differed significantly from control. CONCLUSIONS: The physical properties were manufacturer dependent and mediated by mouth rinses. The mouth rinses promoted color changes in the resin composites, pointing out that bulk-fill resin composites were more affected by these effects, especially when the mouth rinse contained essential oil and alcohol.


Assuntos
Antissépticos Bucais , Óleos Voláteis , Antissépticos Bucais/farmacologia , Resinas Compostas , Etanol , Solubilidade , Teste de Materiais , Propriedades de Superfície
5.
Oper Dent ; 48(6): 677-688, 2023 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-37881103

RESUMO

OBJECTIVE: To evaluate the flexural strength of two types of high-viscosity resin composites (conventional or bulk-fill) that were repaired with either high-viscosity composites (conventional or bulk-fill) or low-viscosity composites (conventional or bulk-fill) of the same manufacturer (3M Oral Care, St Paul, MN, USA). METHODS AND MATERIALS: Specimens (25 mm × 2 mm × 2 mm) of both conventional nanofilled resin (Filtek Z350XT), and bulk-fill nanofilled resin (Filtek One Bulk Fill) were prepared. After fracture of the specimens in the 3-point bending test (initial), half of the specimens were repaired immediately afterwards (24 hours), and the other half were repaired after 6 months of storage in distilled water. Repairs were performed with (n=15) high-viscosity resin composites (Filtek Z350XT, Filtek One Bulk Fill), or their low-viscosity versions (Filtek Supreme XT Flow, Filtek Bulk Fill Flowable Restorative). The repair was performed by roughening the surface and applying phosphoric acid, silane, and adhesive. The bending test (results reported in MPa) was performed in a universal testing machine, and the fracture pattern was determined. Data were evaluated by generalized linear models, chi-square test and the Fisher exact test (α=0.05). RESULTS: There was no significant difference between the former pair of high-viscosity resins in terms of initial flexural strength (p=0.42). The repairs performed with low-viscosity resin composites after 24 hours or 6 months obtained higher MPa values compared with those using high-viscosity composites (p=0.0006). There was a significant decrease in MPa values when the repair was performed after 24 hours and an increase after 6 months, regardless of the material (p<0.0001). After 6 months, fractures involving the old (conventional) resin were more frequent in the repair performed with bulk-fill resin composites compared with the conventional composites (p=0.02). CONCLUSIONS: Considering the tested products, the material to be repaired did not influence the flexural strength of the repair composite; however, the use of the low-viscosity resin composites resulted in greater flexural strength of the repaired material. The repair of the aged composite resulted in an increase in its flexural strength, regardless of the material repaired or used to perform the repair.


Assuntos
Materiais Dentários , Resistência à Flexão , Viscosidade , Teste de Materiais , Resinas Compostas/uso terapêutico
6.
Oper Dent ; 48(5): E95-E105, 2023 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-37503688

RESUMO

This study evaluated dentin enzymatic degradation based on the total matrix metalloproteinase (MMP) activity of demineralized dentin matrices before and after exposure to phosphoric acid (PA), glycolic acid (GA), and ferulic acid (FA). The release of hydroxyproline (HP), ultimate tensile strength (UTS), and dentin permeability (DP) were also evaluated. Dentin collagen matrices were assessed according to total MMP activity before and after treatment with the tested acids (n=10) for 15 seconds and compared with the control (GM6001 inhibitor). Dentin beams were analyzed for HP release and UTS after the treatments. Dentin discs were tested for DP at a pressure of 5 psi before and after treatment with the acids (n=10). The FA group had a lower percentage of enzymatic inhibition than the PA and GA groups (p<0.0001). No significant difference in UTS was found among the acids (p=0.6824), but HP release was significantly higher in the FA group than in the PA and GA groups (p<0.0001). No significant difference in DP was found for the acids (p=0.0535). GA led to less activation of MMPs and less release of HP, whereas the UTS and DP for GA were like those found for PA. In contrast, FA promoted greater enzymatic activity and greater release of HP, while having similar results to GA and PA regarding mechanical properties.


Assuntos
Dentina , Glicóis , Glicóis/metabolismo , Resistência à Tração , Ácidos Fosfóricos/farmacologia , Permeabilidade
7.
Oper Dent ; 48(2): E35-E47, 2023 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-36656318

RESUMO

This study evaluated the etching pattern, surface microhardness, and bond strength for enamel and dentin submitted to treatment with phosphoric, glycolic, and ferulic acids. Enamel and dentin blocks were treated with phosphoric, glycolic, and ferulic acid to evaluate the surface and adhesive interface by scanning electron microscopy (2000×). Surface microhardness (Knoop) was evaluated before and after etching, and microtensile bond strength was evaluated after application of a two-step adhesive system (Adper Single Bond 2, 3M ESPE) at 24 hours and 12 months storage time points. Analysis of variance (ANOVA) and Tukey's test showed a decrease in the microhardness values for both substrates after application of each acid (p<0.0001). The reduction percentage was significantly higher for enamel treated with phosphoric acid (59.9%) and glycolic acid (65.1%) than for ferulic acid (16.5%) (p<0.0001), and higher for dentin that received phosphoric acid (38.3%) versus glycolic acid (27.8%) and ferulic acid (21.9%) (p<0.0001). Phosphoric and glycolic acids led to homogeneous enamel demineralization, and promoted the opening of dentinal tubules, whereas ferulic acid led to enamel surface demineralization and partially removed the smear layer. The adhesive-enamel interface showed micromechanical embedding of the adhesive in the interprismatic spaces when phosphoric and glycolic acids were applied. Ferulic acid showed no tag formation. Microtensile bond strength at both time points, and for both substrates, was lower with ferulic acid (p=0.0003/E; p=0.0011/D; Kruskal Wallis and Dunn). The bond strength for enamel and dentin decreased when using phosphoric and glycolic acids at the 12-month time evaluation (p<0.05). Glycolic acid showed an etching pattern and microhardness similar to that of phosphoric acid. Ferulic acid was not effective in etching the enamel or dentin, and it did not provide satisfactory bond strength to dental substrates.


Assuntos
Colagem Dentária , Desmineralização do Dente , Humanos , Glicóis/análise , Propriedades de Superfície , Ácidos Fosfóricos , Esmalte Dentário/química , Dentina/química , Desmineralização do Dente/induzido quimicamente , Resistência à Tração , Adesivos Dentinários/química , Cimentos de Resina/química
8.
Oper Dent ; 47(2): 173-182, 2022 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-35604820

RESUMO

OBJECTIVES: The aim of this study was to evaluate the effect of different surface treatments and thermocycling (TC) on the push-out bond strength of two brands of glass fiber posts (GFPs) to composite resin. METHODS: White Post DC (WP) (FGM Dental Group International, Joinville, Santa Catarina, BR) and Exacto (EC) (Angelus, Clinical Research Dental, Londrina, PR, Brazil). GFPs were cleaned with 70% alcohol and divided into five groups, according to the surface treatment (n=15): control (C), without treatment; prehydrolyzed silane (S-pre) (Prosil, FGM Dental Group International); 37% phosphoric acid + prehydrolyzed silane (AcS-pre); Scotchbond Universal Adhesive System (AdU), 3M Oral Care; two-bottle silane (S2B) (Dentsply Sirona Inc). The composite resin was inserted around the posts by using a split matrix. The samples were cut into 1-mm slices. Half of the samples were subjected to the push-out test immediately, and the other half underwent TC before the test. After failure analysis, the data were submitted to three-way analysis of variance (ANOVA) (α=0.05). RESULTS: EC achieved higher bond strength than WP, regardless of TC (p<0.05). Regarding WP, surface treatments (p<0.001) and TC (p<0.001) influenced bonding strength. As for EC without TC, the highest bond strength (p<0.05) was found for C, then AcSpre, S-pre, AdU, and S2B. Application of TC resulted in a statistically higher bond strength values for the EC AcS-pre group (p<0.05), followed by S2B, S-pre, C, and AdU. The WP failures were predominantly cohesive, similar to the EC AdU and EC S2B groups. The other EC groups showed mostly mixed failures. CONCLUSIONS: Surface treatment and TC affected the bond strength to composite resin, depending on which post was used. It is important for dentists to understand the effects of different types of silanization on their chosen post.


Assuntos
Colagem Dentária , Técnica para Retentor Intrarradicular , Brasil , Resinas Compostas/química , Colagem Dentária/métodos , Análise do Estresse Dentário , Vidro/química , Teste de Materiais , Cimentos de Resina/química , Silanos/química , Propriedades de Superfície
9.
Oper Dent ; 46(5): 537-546, 2021 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-34929042

RESUMO

The aim of this in vitro study was to quantitatively evaluate the internal gap of resin composites of high-and low-viscosity used in single- and incremental-fill techniques in Class I cavities exposed to thermal cycling (TC) using optical coherence tomography (OCT). Cavities of 4-mm depth and 3-mm diameter were prepared in 36 third molars randomly distributed into four groups, according to viscosity of restorative resin-based composite (high or low viscosity, all from 3M Oral Care) and technique application (bulk or incremental fill) used (n=9): RC, high-viscosity, incremental-fill, resin-based composite (Filtek Z350 XT Universal Restorative); BF, high-viscosity, bulk-fill, resin-based composite (Filtek One Bulk Fill); LRC, lowviscosity, incremental-fill, resin-based composite (Filtek Z350 XT Flowable Universal Restorative); and LBF, low-viscosity, bulk-fill, resin-based composite (Filtek Flowable Restorative). Single Bond Universal Adhesive system (3M Oral Care) was used in all the experimental groups. The incremental-fill technique was used for RC and LRC groups (2-mm increments), and a single-layer technique was used for BF and LBF groups, as recommended by the manufacturer. The internal adaptation of the resin at all dentin walls was evaluated before and after TC (5000 cycles between 5°C and 55°C) using OCT images. Five images of each restored tooth were obtained. Images were analyzed using ImageJ software that measured the entire length of the gaps at the dentin-restoration interface. The length of gaps (µm) was analyzed using two-way repeated measures ANOVA and the Tukey tests (α=0.05). There was a significant interaction between material types and TC (p=0.006), and a significant difference among all material types (p<0.0001), before and after TC (p<0.0001). Increased internal gaps at the dentin-restoration interface were noticed after TC for all groups. RC presented the lowest value of internal gap before and after TC, while LBF showed the highest values of internal gap after TC. In conclusion, TC negatively affected the integrity of internal gap, whereas high-viscosity, incremental-fill, resin-based composite presented better performance in terms of internal adaptation than low-viscosity, bulk-fill materials in Class I cavities.


Assuntos
Cárie Dentária , Restauração Dentária Permanente , Resinas Compostas/química , Resinas Compostas/uso terapêutico , Materiais Dentários/química , Restauração Dentária Permanente/métodos , Humanos , Teste de Materiais , Tomografia de Coerência Óptica , Viscosidade
10.
Eur J Prosthodont Restor Dent ; 27(3): 103-112, 2019 Aug 29.
Artigo em Inglês | MEDLINE | ID: mdl-31433135

RESUMO

The purpose was to evaluate the influence of dentin pretreatment with titanium tetrafluoride (TiF4) on the longevity of bond strength (BS) of an indirect composite to dentin, using conventional resin cementation strategy or a self-adhesive resin cement. Forty third human molars with exposed dentin surfaces were used. The teeth were divided into groups (n = 10), according to the cementation strategy and the presence or absence of pretreatment with TiF4. Microtensile strength testing and failure mode analysis were performed after 24 hours, 180 and 360 days of storage in water. Split-plot ANOVA and Tukey's test showed that BS was significantly higher when the conventional strategy was used, regardless of the time period, and of the application or no application of pretreatment with TiF4 (p ⟨0.0001). When TiF4 was used for both cementing strategies, BS was lower after 360 days (p = 0.0019). Both cementing strategies led to the formation of a shallow hybrid layer, regardless of the presence of TiF4. BS was higher when the conventional cementation strategy was used, regardless of TiF4 pretreatment. TiF4 used as a pretreatment agent associated with different types of resin cementation was unable to maintain adhesive bond strength in the long term.


Assuntos
Cimentação , Colagem Dentária , Cimentos Dentários , Fluoretos , Cimentos de Resina , Titânio , Resinas Compostas , Análise do Estresse Dentário , Dentina , Adesivos Dentinários , Humanos , Teste de Materiais , Resistência à Tração
11.
Oper Dent ; 44(6): 595-608, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31034349

RESUMO

The purpose of this in situ study was to evaluate the influence of staining solutions (coffee and cola) on the color change, microhardness, roughness, and micromorphology of the enamel surface during at-home and in-office dental bleaching. One hundred and thirty-five enamel bovine blocks were prepared to perform the evaluations. Fifteen volunteers used an intraoral appliance with nine enamel blocks for 15 days. The enamel blocks were randomly assigned among the different groups according to the three treatments: in-office bleaching with high hydrogen peroxide concentration (Opalescence Boost PF 40%, Ultradent) for 40 minutes in three sessions (first, eighth, and 15th days of treatment), at-home bleaching with low carbamide peroxide concentration (Opalescence PF 10%, Ultradent) for 60 minutes daily for 15 days, and a control group (no bleaching agent applied). The enamel blocks were immersed daily in different staining solutions (coffee or cola) for 30 minutes for 15 days or were not submitted to staining (control) to obtain a factorial scheme (3×3) of the dental bleaching treatment and staining solution (n=15). The microhardness analyses (Knoop), roughness evaluations (Ra), surface micromorphological observations, and color measurements (using the CIELAB system and the VITA Classical scale) were made before and after the bleaching treatments to assess immersion in staining solutions. Mixed model tests showed that there was a decrease in enamel microhardness after exposure to cola compared with coffee and the control group (p<0.0001) for both bleaching techniques. Roughness was higher for the cola groups (p<0.0001), and there was no significant difference between the coffee and the control groups. Generalized linear models showed that when no staining solution was applied, lighter color scores were found for the VITA Classical scale (p<0.0001). Without the staining solutions, there was an increase in luminosity (ΔL) (p=0.0444) for in-office bleaching. Lower values of Δa (p=0.0010) were observed when the staining solutions were not used. The Δb (p=0.3929) did not vary significantly between the bleaching agents, but when cola was applied, the values were significantly higher than for the control (p=0.0293). Higher values of ΔE (p=0.0089) were observed for in-office bleaching without staining solutions, while lower values of ΔE were observed for the in-office associated with coffee immersion. Regardless of whether being submitted to bleaching, the enamel stained with cola showed a decrease in microhardness, an increase in roughness, and changes in the micromorphology. The efficacy of the bleaching agents was greater when no staining solution (cola or coffee) was used, and in-office bleaching showed greater color change than the at-home bleaching technique.


Assuntos
Clareamento Dental , Animais , Bovinos , Cor , Esmalte Dentário , Humanos , Peróxido de Hidrogênio , Peróxidos , Coloração e Rotulagem , Propriedades de Superfície , Ureia
12.
Arch Oral Biol ; 91: 51-56, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29673998

RESUMO

OBJECTIVE: The purpose of this study was to investigate the effects of aqueous solutions of different concentrations of titanium tetrafluoride (TiF4) on dentin matrix stability up to six months. DESIGN: Dentin specimens prepared from fifteen nonerupted molars were demineralized and randomly distributed into groups: 2.5% TiF4, 4% TiF4, 1000 ppm NaF, and control (distilled water). The modulus of elasticity (ME) and dry masses of the dentin matrix were determined at baseline, and up to 6 months following treatment. Collagen solubilization was estimated by hydroxyproline (HYP) quantification in the simulated body fluid used to store the dentin specimens. RESULTS: The 2.5% TiF4 group presented higher ME immediately after treatment, and at 3 and 6 months storage, whereas 4% TiF4 showed higher means at 3 and 6 months (p < 0.001). No significant differences were observed among the groups over time (p = 0.9325). However, the 2.5% TiF4 group showed significantly higher ME than the control group, immediately after treatment. All the groups presented significantly higher mass change immediately, compared with 3 and 6 months (p < 0.0001). Except for the 4% TiF4 group, HYP release was higher in the first quarter (p = 0.0152), when no significant differences were found among the groups. In the second quarter, the means were significantly higher in the 2.5% TiF4 and 4% TiF4 groups. The group treated with 2.5% TiF4 had a statistically higher HYP release than the control group. CONCLUSION: An aqueous solution of 2.5% TiF4 increases the immediate stiffness values, but does not stabilize the collagenous dentin matrix.


Assuntos
Dentina/química , Dentina/efeitos dos fármacos , Fluoretos/administração & dosagem , Fluoretos/farmacologia , Titânio/administração & dosagem , Titânio/farmacologia , Cariostáticos/farmacologia , Módulo de Elasticidade/efeitos dos fármacos , Humanos , Hidroxiprolina , Técnicas In Vitro , Teste de Materiais , Dente Molar/química , Dente Molar/efeitos dos fármacos , Peptídeo Hidrolases/efeitos dos fármacos , Fatores de Tempo , Desmineralização do Dente/tratamento farmacológico
13.
Oral Dis ; 24(6): 957-963, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-29423930

RESUMO

OBJECTIVES: To investigate whether saliva formulations with reduced calcium (Ca) and inorganic phosphorous (Pi) concentration would affect dental erosion caused by hydrochloric acid (HCl). METHODS: Enamel and root dentine bovine slabs were embedded, polished, and measured for surface Knoop microhardness (SMH). After reference areas were created, specimens were exposed to HCl solution (0.01 M; pH 2; 120 s) and immersed in artificial salivas (6 hr) containing three different Ca/Pi concentrations (n = 15), which simulate serum conditions of normo-, mild, or severe hypocalcemia. The control group was immersed in Ca/Pi-free saliva. The study protocol was carried out 2×/day for 5 days. Surface loss of enamel and root dentine was assessed using an optical profilometer, and SMH was remeasured for enamel. RESULTS: One-way analysis of variance (p < .001) and Tukey's test showed that enamel loss in groups subjected to artificial salivas that simulated mild or severe hypocalcemia did not differ from that resembling normocalcemia. %SMH was lower when saliva was mildly and normally concentrated in Ca/Pi (p < .001). Root dentine loss was higher in saliva simulating severe hypocalcemia than in those referring to mild, hypo-, and normocalcemia. CONCLUSIONS: Depending on the dental substrate, salivary formulations resembling serum hypocalcemia affected surface loss due to erosion and rehardening thereof.


Assuntos
Cálcio/análise , Esmalte Dentário/química , Dentina/química , Fósforo/análise , Saliva Artificial/química , Animais , Bovinos , Ácido Clorídrico/efeitos adversos , Ácido Clorídrico/química , Erosão Dentária/induzido quimicamente
15.
J Craniomaxillofac Surg ; 45(11): 1820-1827, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-28935483

RESUMO

PURPOSE: The aim of this study was to evaluate the distribution of deformation stresses in customized and non-customized plates during simulated advancement genioplasty, using the finite element method. METHODS: A customized plate (Traumec) was developed with 4.75 mm advancement, in ASTM F67 Grade 2 titanium, with four screws. Non-customized (standard) plates with 6 mm advancement (Stryker with six screws and Osteomed with four screws) were used for comparison. All the screws presented the same length (10 mm) and fixation system (2.0). The Traumec and Osteomed plates were fixed with two screws in the mandible, and another two in the segment, whereas the Stryker plate was fixed with three screws in the mandible, and another three in the segment. Six virtual models were generated in a computer-aided design program (Rhinoceros), in which the advancement and insertion of the plates were evaluated. All the plates were submitted to application of perpendicular and oblique forces of 5 N in the chin region. RESULTS: The Osteomed plate showed the highest stress value (1506 MPa), and the Traumec, the lowest stress value (560.20 MPa). The Stryker plate showed higher stress values for the segment screws than for the mandibular screws, unlike the other plates. CONCLUSIONS: The customized Traumec plate showed better deformation stress distribution and plate/segment stabilization when submitted to advancement genioplasty.


Assuntos
Placas Ósseas , Mentoplastia/instrumentação , Desenho de Prótese , Parafusos Ósseos , Simulação por Computador , Análise de Elementos Finitos , Humanos , Estresse Mecânico
16.
Oper Dent ; 42(3): 308-318, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28467252

RESUMO

The purpose of this study was to evaluate the calcium (Ca) and phosphorous (P) content in enamel bleached with high and low concentrations of hydrogen peroxide (HP) using Total Reflection X-Ray Fluorescence (TXRF) and colorimetric spectrophotometry (SPEC). Forty-eight sound human third molars were used. Their roots were embedded in polystyrene resin and immersed for seven days in an artificial saliva solution. Then they were distributed into six groups to receive the bleaching treatments. The agents of high HP concentration (for in-office use) evaluated were Whiteness HP Maxx/FGM (35% HP), Whiteness HP Blue/FGM (35% HP, 2% calcium gluconate), Pola Office+/SDI (37.5% HP, 5% potassium nitrate), and Opalescence Boost/Ultradent (38% HP, 1.1% ion fluoride, 3% potassium nitrate); these agents were applied to enamel in three sessions. The agents of low HP concentration (for home use) evaluated were Pola Day/SDI (9.5% HP) and White Class 10%/FGM (10% HP, potassium nitrate, calcium, fluoride), and these agents were applied for 14 days. Enamel microbiopsies were evaluated by TXRF and SPEC analysis before the bleaching treatment (baseline), during the treatment, and 14 days after the end of the treatment. For TXRF, the Kruskal-Wallis test showed that Ca and P were not influenced by agent (p>0.05). For SPEC, Pola Office+, Opalescence Boost, Pola Day, and White Class 10% caused a decrease of Ca over time; there was a significant decrease of P over time to Pola Office+ and White Class 10%. The Spearman test showed no correlation between the Ca (p=0.987; r2=-0.020) and P (p=0.728, r2=0.038) obtained by SPEC and TXRF. For TXRF and SPEC, changes in Ca and P during bleaching occurred independently of the HP concentration used.


Assuntos
Cálcio/química , Esmalte Dentário/química , Esmalte Dentário/efeitos dos fármacos , Peróxido de Hidrogênio/química , Fósforo/química , Clareadores Dentários/química , Colorimetria , Fluorescência , Dureza , Humanos , Técnicas In Vitro , Dente Serotino , Espectrofotometria , Raios X
17.
Oper Dent ; 42(1): 30-40, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-27723425

RESUMO

The purpose of this study was to evaluate bleaching methods containing hydrogen peroxide (HP) or carbamide peroxide (CP), dispensed in customized or prefilled trays, in terms of color change, tooth sensitivity, gingival irritation, acceptance, and comfort. Seventy-five volunteers were randomly selected and distributed according to the whitening agent (n=25): 10% HP dispensed in prefilled trays (Opalescence Go 10%) and 9.5% HP (Pola Day) and 10% CP both delivered in customized trays (Opalescence PF 10%). HP was applied for 30 min/d for 14 days (d), and CP for 8 h/d for 14 days. Evaluations were performed at baseline and at 7 days and 14 days of treatment. Color change was measured with Commission internationale de l'éclairage color coordinates (L*, a*, b*), Vita Classical, and 3D Master scales. A visual analog scale was used to assess tooth sensitivity, acceptance of the method and degree of comfort of the tray. Gingival irritation was evaluated as present or absent and localized or generalized. Regarding gingival irritation, tray acceptance, and tooth sensitivity, no differences were observed among the groups at any time (p>0.05). As for degree of comfort, 10% HP showed lower scores (comfortable) than 10% CP, with significant differences (p<0.05) from the other groups (comfortable to very comfortable). In terms of ΔL, Δa, and ΔE, no difference was observed among the groups or between the time periods (p>0.05). The Δb average was higher at 14 days (p<0.05), and there was no difference among the groups (p>0.05). Localized gingival irritation was observed in both tray methods. Mild tooth sensitivity was observed with time, regardless of the bleaching agent concentration or the application time. Color change was similar for all the groups at 7 days and 14 days, but there was a greater reduction in the yellow hue at 14 days. All the bleaching methods were highly accepted and effective in promoting whitening. Although prefilled trays are generally comfortable, they proved less comfortable than customized trays.


Assuntos
Dispositivos para o Cuidado Bucal Domiciliar , Clareadores Dentários/uso terapêutico , Clareamento Dental/instrumentação , Adulto , Peróxido de Carbamida , Combinação de Medicamentos , Feminino , Humanos , Peróxido de Hidrogênio/uso terapêutico , Masculino , Peróxidos/uso terapêutico , Polivinil , Resultado do Tratamento , Ureia/análogos & derivados , Ureia/uso terapêutico
18.
Oper Dent ; 39(1): 64-71, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-23675741

RESUMO

The aim of this study was to evaluate the effect of a chlorhexidine and/or ethanol application on the bond strength of an etch-and-rinse, hydrophobic adhesive system either under in vitro aging or in situ cariogenic challenge. The dentin surface of 36 human third molars were flattened and allocated into four groups to be treated with chlorhexidine, ethanol, or chlorhexidine + ethanol or left unexposed to any solution (control) (n=9). Then, a resin composite restoration was made on the dentin surface and longitudinal sticks were obtained. Sticks from each tooth were assigned to three test conditions: stored in water in vitro for 24 hours, stored in water in vitro for 6 months, or worn in situ for 14 days. During in situ wear time, a high-cariogenic challenge condition was simulated. Specimens were tested for microtensile bond strength (µTBS). Multivariate analysis of variance and Tukey's test showed that chlorhexidine, ethanol, or chlorhexidine + ethanol did not affect the µTBS. The in vitro µTBS values were significantly lower for the specimens stored for 6 months than for those stored for 24 hours. Intermediate µTBS values were shown by the specimens worn in situ. Thus, use of chlorhexidine and/or ethanol was incapable of containing the degradation at the bond interface in the in vitro model. The in situ model was capable of reducing bond strength similarly to the in vitro/6 months model. Despite this, the in situ bond strength was still similar to that of the in vitro/24-hour model.


Assuntos
Clorexidina/farmacologia , Cimentos Dentários/metabolismo , Corrosão Dentária/métodos , Dentina/efeitos dos fármacos , Etanol/farmacologia , Resinas Compostas/uso terapêutico , Colagem Dentária , Análise do Estresse Dentário , Humanos , Técnicas In Vitro
19.
Oper Dent ; 38(6): 567-71, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23570298

RESUMO

Dental ceramics make it possible to restore anterior teeth that have been esthetically compromised, presenting a high resistance to wear, biocompatibility, color stability, and low thermal conductivity. The development of different types of ceramic and techniques for adhesive cementation have made it possible to produce more conservative restorations without involving the healthy dental structure and with minimally invasive preparation, such as the bonding of ceramic fragments. The purpose of this article is to describe a clinical case in which diastemas were closed by using nanofluorapatite ceramic (e.max Ceram, Ivoclar-Vivadent) fragments on teeth 7 and 10 with minimal tooth preparation and metal-free ceramic crowns (e-max Ceram) reinforced with zirconia copings through a computer-aided design/computer-aided manufacturing system (Lava, 3M-ESPE) on teeth 8 and 9.


Assuntos
Coroas , Porcelana Dentária/uso terapêutico , Diastema/terapia , Estética Dentária , Adulto , Feminino , Humanos , Incisivo
20.
Oper Dent ; 37(5): 464-73, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22616927

RESUMO

The aim of this study was to compare the effectiveness of and tooth sensitivity to 10% and 20% carbamide peroxide (CP) home-use bleaching agents and 35% and 38% hydrogen peroxide (HP) in-office bleaching agents, all of which contain desensitizing agents, in a clinical trial. Four agents were evaluated: 10% CP and 20% CP (Opalescence PF 10% and Opalescence PF 20%, Ultradent, both with 0.5% potassium nitrate and 0.11% fluoride ions), 38% HP (Opalescence Boost PF, Ultradent, with 3% potassium nitrate and 1.1% fluoride ions), and 35% HP (Pola Office, SDI, with potassium nitrate). The initial screening procedure included 100 volunteers, aged 18 to 42, with no previous sensitivity or bleaching treatment and with any tooth shade. Volunteers were randomly assigned among the technique/bleaching agent groups. A run-in period was performed 1 week before the beginning of the bleaching treatment. For the home-use bleaching technique, each volunteer was instructed to dispense gel (10% CP or 20% CP) into the trays and then insert them into his or her mouth for at least two hours per night for three weeks. For the in-office bleaching technique, the bleaching agents (38% HP or 35% HP) were prepared and used following the manufacturer's instructions, with three applications performed in each session. Three sessions were carried out with an interval of seven days between each session. The participants were evaluated before, at one week, two weeks, and three weeks after the beginning of the bleaching treatment, and again one and two weeks after the bleaching treatment ended. A shade guide (Vita Classical, Vita) was used by a blinded examiner to perform shade evaluations before bleaching and two weeks after the end of bleaching. At the time of the shade evaluations, tooth sensitivity was also recorded by asking the volunteers to classify the sensitivity during bleaching treatment as absent, mild, moderate, or severe. The present study found that 13.8% of the volunteers withdrew from the study due to tooth sensitivity, and 43.2% of the participants experienced some type of sensitivity during bleaching treatment. The χ(2) test showed that there was a significant prevalence of tooth sensitivity during bleaching treatment using the home-use 20% CP agent, with 71.4% of volunteers reporting any level of tooth sensitivity (p=0.0032). A low prevalence of tooth sensitivity was observed for volunteers who used the in-office 38% HP agent (15.0%). The Wilcoxon test (p<0.05) showed that all of the bleaching treatments were effective in bleaching teeth and that there were no differences between the final color shade results among the treatments (Kruskal-Wallis, p<0.05). This study showed that 43.2% of all the volunteers experienced mild or moderate tooth sensitivity during the treatment with bleaching agents. A higher prevalence of tooth sensitivity was observed for 71.4% of the volunteers who used the 20% CP home-use bleaching agent, which may be ascribed to the peroxide concentration and/or the time/length the agent was in contact with the dental structures.


Assuntos
Dessensibilizantes Dentinários/administração & dosagem , Sensibilidade da Dentina/induzido quimicamente , Peróxido de Hidrogênio/administração & dosagem , Peróxidos/administração & dosagem , Clareadores Dentários/administração & dosagem , Clareamento Dental/métodos , Ureia/análogos & derivados , Adolescente , Adulto , Peróxido de Carbamida , Cor , Fluoretos/administração & dosagem , Seguimentos , Humanos , Peróxido de Hidrogênio/efeitos adversos , Nitratos/administração & dosagem , Peróxidos/efeitos adversos , Compostos de Potássio/administração & dosagem , Dente/efeitos dos fármacos , Dente/patologia , Clareadores Dentários/efeitos adversos , Descoloração de Dente/tratamento farmacológico , Descoloração de Dente/patologia , Resultado do Tratamento , Ureia/administração & dosagem , Ureia/efeitos adversos , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...