Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Med Virol ; 93(5): 3152-3157, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33615487

RESUMO

The severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) pandemic has become a major public health issue worldwide. Developing and evaluating rapid and easy-to-perform diagnostic tests is a high priority. The current study was designed to assess the diagnostic performance of an antigen-based rapid detection test (COVID-VIRO®) in a real-life setting. Two nasopharyngeal specimens of symptomatic or asymptomatic adult patients hospitalized in the Infectious Diseases Department or voluntarily accessing the COVID-19 Screening Department of the Regional Hospital of Orléans, France, were concurrently collected. The diagnostic specificity and sensitivity of COVID VIRO® results were compared to those of real-time reverse-transcriptase quantitative polymerase chain reaction (RT-qPCR) results. A subset of patients underwent an additional oropharyngeal and/or saliva swab for rapid testing. A total of 121 patients confirmed to be infected and 127 patients having no evidence of recent or ongoing infection were enrolled for a total of 248 nasopharyngeal swab specimens. Overall, the COVID-VIRO® sensitivity was 96.7% (CI, 93.5%-99.9%). In asymptomatic patients, symptomatic patients having symptoms for more than 4 days and those with an RT-qPCR cycle threshold value ≥ 32, the sensitivities were 100%, 95.8%, and 91.9%, respectively. The concordance between RT-qPCR and COVID VIRO® rapid test results was 100% for the 127 patients with no SARS-CoV-2 infection. The COVID-VIRO® test had 100% specificity and sensitivity greater than 95%, which are better than the recommendations set forth by the WHO (specificity ≥ 97%-100%, sensitivity ≥ 80%). These rapid tests may be particularly useful for large-scale screening in emergency departments, low-resource settings, and airports.


Assuntos
Antígenos Virais/isolamento & purificação , Teste para COVID-19/métodos , COVID-19/diagnóstico , Nasofaringe/virologia , SARS-CoV-2/isolamento & purificação , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Testes Imediatos , Sensibilidade e Especificidade , Adulto Jovem
2.
J Small Anim Pract ; 61(4): 224-229, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32017094

RESUMO

OBJECTIVES: To compare elbow congruity in two cohorts of Labrador retrievers affected with either radial incisure or apex fragmentation of the medial coronoid process. MATERIALS AND METHODS: Dogs were included if they had elbow lameness and a CT diagnosis of a fissure or fragmentation of the medial coronoid process occurring either along the radial incisure or at the coronoid apex. Radioulnar joint space was measured incrementally from the lateral to the medial coronoid process on transverse slice images. Axial radioulnar congruency was also measured at the apex and mid-coronoid in the dorsal plane and at the base of the coronoid in the sagittal plane. RESULTS: We studied 99 elbows (in 66 dogs) of which 56 had a fissure or fragmentation along the radial incisure and 43 had an apical fragment. No difference was found between the two groups at the different measuring points - with the exception of a transverse plane radioulnar joint space measurement in the radial incisure group that was smaller adjacent to the lateral coronoid process. CLINICAL SIGNIFICANCE: Abnormal ulnar morphology in the radial incisure group could result in a fulcrum effect within the radioulnar joint, overloading the radial incisure and predisposing to osteochondral damage at this site.


Assuntos
Doenças do Cão , Artropatias/veterinária , Animais , Doenças do Cão/diagnóstico por imagem , Cães , Membro Anterior , Artropatias/diagnóstico por imagem , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...