Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Nat Commun ; 14(1): 7893, 2023 Nov 30.
Artigo em Inglês | MEDLINE | ID: mdl-38036510

RESUMO

Expansion microscopy (ExM) is a highly effective technique for super-resolution fluorescence microscopy that enables imaging of biological samples beyond the diffraction limit with conventional fluorescence microscopes. Despite the development of several enhanced protocols, ExM has not yet demonstrated the ability to achieve the precision of nanoscopy techniques such as Single Molecule Localization Microscopy (SMLM). Here, to address this limitation, we have developed an iterative ultrastructure expansion microscopy (iU-ExM) approach that achieves SMLM-level resolution. With iU-ExM, it is now possible to visualize the molecular architecture of gold-standard samples, such as the eight-fold symmetry of nuclear pores or the molecular organization of the conoid in Apicomplexa. With its wide-ranging applications, from isolated organelles to cells and tissue, iU-ExM opens new super-resolution avenues for scientists studying biological structures and functions.


Assuntos
Organelas , Imagem Individual de Molécula , Microscopia de Fluorescência/métodos , Imagem Individual de Molécula/métodos
2.
Phys Med ; 39: 33-38, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28711186

RESUMO

PURPOSE: To show the usefulness of topographic 2D megavoltage images (MV2D) for the localization of breast cancer patients treated with TomoDirect (TD), a radiotherapy treatment technique with fixed-angle beams performed on a TomoTherapy system. METHODS: A method was developed to quickly localize breast cancer patients treated with TD by registering the MV2D images produced before a TD treatment with reference images reconstructed from a kilovoltage CT simulation scanner and by using the projection of the beam-eye-view TD treatment field. Dose and image quality measurements were performed to determine the optimal parameters for acquiring MV2D images. A TD treatment was simulated on a chest phantom equipped with a breast attachment. MVCT and MV2D images were performed for 7 different shifted positions of the phantom and registered by 10 different operators with the simulation kilovoltage CT images. RESULTS: Compared to MVCT, MV2D imaging reduces the dose by a factor of up to 45 and the acquisition time by a factor of up to 49. Comparing the registration shift values obtained for the phantom images obtained with MVCT in the coarse mode to those obtained with MV2D, the mean difference is 1.0±1.1mm, -1.1mm±1.1, and -0.1±2.2mm, respectively, in the lateral, longitudinal, and vertical directions. CONCLUSIONS: With dual advantages (very fast imaging and a potentially reduced dose to the heart and contralateral organs), MV2D topographic images may be an attractive alternative to MVCT for the localization of breast cancer patients treated with TomoDirect.


Assuntos
Neoplasias da Mama/radioterapia , Planejamento da Radioterapia Assistida por Computador , Radioterapia Conformacional , Tomografia Computadorizada por Raios X , Neoplasias da Mama/diagnóstico por imagem , Humanos , Imagens de Fantasmas , Tórax
3.
Artigo em Inglês | MEDLINE | ID: mdl-18003281

RESUMO

This paper presents a quantification method which can be used to quantify the evolution of a brain tumor with time. From two segmented volumes, a Local Distance Volume (LDV) based on Hausdorff Distance is computed to show the true physical local distances between them. In the case of tracking a tumor volume during a therapeutic treatment, local variations can thus be shown by the LDV in particular where the tumor has regressed and where it has grown. This information can help radiologists to adapt the current treatment.


Assuntos
Inteligência Artificial , Neoplasias Encefálicas/diagnóstico , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Reconhecimento Automatizado de Padrão/métodos , Técnica de Subtração , Algoritmos , Humanos , Aumento da Imagem/métodos , Invasividade Neoplásica , Reprodutibilidade dos Testes , Sensibilidade e Especificidade