Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 73
Filtrar
1.
J Vet Intern Med ; 38(3): 1384-1407, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38647174

RESUMO

BACKGROUND: Health-related quality-of-life (HRQoL) assessment tools are becoming increasingly important for the assessment of diseases in veterinary medicine. OBJECTIVES: To develop a tool to assess the HRQoL of hyperthyroid cats and their owners. ANIMALS: Cats with hyperthyroidism (n = 229) and without hyperthyroidism (n = 322). METHODS: Cross-sectional study design. A preliminary list of 28 questions relating to the HRQoL of hyperthyroid cats and the influence their cat's disease might have on owners was created. Each question consisted of 2 subquestions: (1) "how often does the item apply"; (2) "how strongly does the item affect HRQoL." The questionnaire was refined based on statistical analysis, including Mann-Whitney-U tests on each item, comparing the results from cats with and without hyperthyroidism. Internal consistency and reliability of the questions were measured by Cronbach's alpha (α). P < .05 was considered significant. RESULTS: Overall, 25/28 questions were retained within the final HRQoL tool, which had an excellent internal consistency (α = .92). The tool produced a score between 0 and 382 (lower scores meaning better HRQoL). The median HRQoL score was 87.5 (range, 2-348) for cats with hyperthyroidism, and 27 (range, 0-249) for cats without (P < .001), suggesting the HRQoL was poorer in hyperthyroid cats. CONCLUSIONS AND CLINICAL IMPORTANCE: This validated HRQoL tool is useful to reliably quantify the influence of hyperthyroidism on the quality-of-life of affected cats and their owners. In the future, it could be considered of assistance in the clinical assessment of cats with hyperthyroidism.


Assuntos
Doenças do Gato , Hipertireoidismo , Qualidade de Vida , Animais , Gatos , Hipertireoidismo/veterinária , Hipertireoidismo/psicologia , Doenças do Gato/psicologia , Inquéritos e Questionários , Estudos Transversais , Masculino , Feminino , Reprodutibilidade dos Testes , Humanos
2.
Artigo em Alemão | MEDLINE | ID: mdl-38056480

RESUMO

This case report describes the rare phenomenon of emperipolesis-like invasion of lymphatic blasts into the hepatocytes of a 15-year-old European Shorthair cat. The cat presented with nonspecific clinical signs (inappetence and weight loss). Cytologic examination of an ultrasound-guided fine-needle aspirate of the liver showed a subset of hepatocytes with emperipolesis-like invasion by lymphatic blasts. Few extracellularly located lymphatic blasts exhibited erythrophagia. Following the cytological diagnosis of large cell lymphoma and 2 weeks of monotherapy with prednisolone, the patient was euthanized due to his poor general condition. A post-mortem sample was obtained from the liver to confirm the suspected cytological diagnosis of hepatocytotropic lymphoma. Histopathology subsequently confirmed the cytologic findings. Immunohistochemically, the lymphatic blasts were positive for CD3 leading to a diagnosis of hepatocytotropic T-cell-lymphoma, which has rarely been described so far.


Assuntos
Doenças do Gato , Linfoma de Células T , Linfoma , Masculino , Animais , Gatos , Linfoma de Células T/diagnóstico , Linfoma de Células T/veterinária , Linfoma de Células T/patologia , Fígado/patologia , Linfoma/patologia , Linfoma/veterinária , Catalase , Linfócitos T/patologia , Doenças do Gato/diagnóstico por imagem , Doenças do Gato/patologia
3.
Vet Sci ; 10(9)2023 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-37756097

RESUMO

Previously, radioimmunoassay (RIA) has been the only assay to measure insulin-like growth factor-1 (IGF-1) to diagnose hypersomatotropism (HS). Due to radiation concerns, availability, and the cost of IGF-1 RIA, validation of assays for automated analysers such as a chemiluminescent immunoassay (CLIA) is needed. The aim of this study was to validate a CLIA for measurement of feline IGF-1 (IMMULITE 2000® XPi, Siemens Medical Solutions Diagnostics, Malvern, PA, USA) compared to IGF1 RIA, establish reference interval (RI), and determine a cut-off value for diagnosis of HS in diabetic cats. Validation of assay performance included precision, linearity, and recovery studies. Right-sided RI was determined using surplus serum of 50 healthy adult cats. Surplus serum samples of diabetic cats with known IGF-1 concentration with (n = 32/68) and without HS (n = 36/68) were used for method comparison with RIA. The cut-off for diagnosis of HS was established using receiver operating characteristic (ROC) analysis. The intra-assay coefficient of variation (CV) was ≤4.7%, and the inter-assay CV was ≤5.6% for samples with low, medium, and high IGF-1 concentration. Linearity was excellent (R2 > 0.99). The correlation between CLIA and RIA was very high (rs = 0.97), with a mean negative bias for CLIA of 24.5%. The upper limit of RI was 670 ng/mL. ROC analysis showed an area under the curve of 0.94, with best cut-off for diagnosis of HS at 746 ng/mL (sensitivity, 84.4%; specificity, 97.2%). The performance of CLIA was good, and the RI and cut-off for HS diagnosis established in this study allow for CLIA to be used in routine work-up of diabetic cats.

4.
J Vet Diagn Invest ; 35(6): 679-697, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37612877

RESUMO

The vCell 5 (scil Animal Care), a point-of-care hematology analyzer (POCA), was recently introduced to veterinary laboratories. This laser- and impedance-based analyzer is capable of providing a CBC with 5-part WBC differential count (Diff) along with WBC cytograms and flags serving as interpretation aids for numerical results. We compared the scil POCA-Diff to reference methods (i.e., manual differential count, Advia 2120 hematology analyzer [Siemens]) for canine and feline blood samples and considered WBC cytograms and flags. Total observed error (TEo), calculated from CV and bias%, was compared to total allowable error (TEa). Data were analyzed before and after a review process (exclusion of flagged and samples with invalid cytograms). For both species, correlation was good-to-excellent (rs = 0.81-0.97) between both analyzers for all variables, except for feline monocytes (rs = 0.21-0.63) and canine monocyte% (rs = 0.50). Smallest biases were seen for neutrophils (dog: -5.7 to 0.8%; cat: 1.5-9.4%) with both reference methods. Quality requirements (TEo < TEa) were fulfilled for canine and feline neutrophils (TEo = 5.3-10.6%, TEa = 15%) and eosinophils (TEo = 67.1-83%, TEa = (90)-50%) considering at least one reference method. Our review process led to mildly higher rs-values for most variables. Although not completely satisfactory, the scil POCA provides reliable results in compliance with ASVCP quality goals for canine and feline neutrophils and eosinophils. Analyzer flag and cytogram analysis served as useful tools for QA, indicating the necessity for manual review of blood smears, and contributed to improvement of scil POCA performance.


Assuntos
Doenças do Gato , Doenças do Cão , Hematologia , Gatos , Cães , Animais , Sensibilidade e Especificidade , Contagem de Leucócitos/veterinária , Neutrófilos , Reprodutibilidade dos Testes
5.
Animals (Basel) ; 13(12)2023 Jun 08.
Artigo em Inglês | MEDLINE | ID: mdl-37370428

RESUMO

The traditional veterinary classification (TVC) of effusions based on cell count and total protein (TP) does not adequately reflect the aetiology. Light's criteria (LC) (activity of lactate dehydrogenase [LDH] in the effusion [LDHef], effusion/serum LDH ratio [LDHr], effusion/serum TP ratio [TPr]), serum-effusion albumin gradient (ALBg), acute phase proteins (APPs) [serum amyloid A (SAA), α1-acid glycoprotein (AGP), haptoglobin] might aid classification. The aim was to evaluate the utility of these parameters except LDHr in differentiating exudates from transudates. Sixty-five cats with effusions (33 peritoneal, 31 pleural, 1 pericardial), with 18 transudates and 47 exudates based on aetiological classification (AC), were included. The sensitivity, specificity and accuracy of several parameters to identify exudates (based on AC) was assessed. APPs were compared between exudates and transudates based on AC and TVC, with receiver operating characteristics analysis identifying the best APP to recognise exudates. Simplified LC (LDHef, TPr) had an accuracy of 79% and TVC of 48%. ALBg had the highest sensitivity (98%) and LDHef the highest specificity (83%) in identifying exudates in cats. All APPs but effusion SAA could differentiate exudates from transudates based on AC (effusion AGP had the largest area under the curve 0.79) but not TVC. All parameters were better than TVC in identifying exudates. The conformity of APPs with AC but not TVC favours the use of AC to classify effusions.

6.
J Feline Med Surg ; 25(5): 1098612X231162836, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-37145170

RESUMO

OBJECTIVES: The aim of this study was to evaluate performance of a feline-specific ELISA for the measurement of alpha-1-acid glycoprotein (AGP) and to establish a reference interval (RI). METHODS: Surplus serum samples with low (~200 µg/ml), medium (~450 µg/ml) and high (~745 and 930 µg/ml) AGP concentrations were used to assess the intra- and inter-assay coefficients of variation (CVs). The quality goal for bioanalytical method validation was a CV of <20%. Linearity was assessed by serial dilution of a sample with a high AGP concentration. Spike recovery was evaluated by mixing samples with low, medium and high AGP concentrations at different ratios. To establish the RI, residual serum samples from 51 healthy adult cats that were presented for health examinations or blood donation between August 2020 and June 2021 were included. RESULTS: The intra-assay CV was 8.5%, 4.3% and 4.0%, and the inter-assay CV was 18.8%, 15.5% and 11.5% for serum samples with low, medium and high AGP concentrations, respectively. Excellent linearity (R2 = 0.98) was demonstrated for AGP concentrations ranging between 251.6 and 954.4 µg/ml. Average recovery was 95.0-99.7%. The right-sided RI for AGP was 328 µg/ml (90% confidence interval 300-354). Age had a statistically significant impact (increasing values with older age, P = 0.0026), but sex did not (P = 0.44), on AGP concentrations. CONCLUSIONS AND RELEVANCE: The ELISA was accurate and showed acceptable precision with the modification of dilution used in this study. AGP concentrations in this population appeared to increase with increasing age.


Assuntos
Orosomucoide , Gatos , Animais , Orosomucoide/análise , Ensaio de Imunoadsorção Enzimática/veterinária , Ensaio de Imunoadsorção Enzimática/métodos , Catalase
7.
Artigo em Alemão | MEDLINE | ID: mdl-36917993

RESUMO

This case report describes a rare case of a myxosarcoma in a 1-year-old teddy bear hamster presenting with a mass in the cervical region. The fine-needle aspiration cytology revealed high numbers of pleomorphic spindle-shaped cells found in a viscous mucinous background. The presumptive cytological diagnosis was malignant spindle cell neoplasia based on marked criteria of malignancy of the mesenchymal cell population. The abundant matrix in the background was suggestive of a myxosarcoma. The hamster died during surgery and a necropsy was performed. Histopathology was in complete agreement with the cytological report. Immunohistochemistry revealed the tumour to be vimentin positive with alcian-blue positive matrix and confirmed the presumptive diagnosis of a myxosarcoma. This case shows that fine-needle aspiration cytology can be utilized as a minimally invasive diagnostic tool in small mammals to classify mass lesions. However, so far little is known about the biological behaviour of myxosarcoma in the hamster as case descriptions are rare.


Assuntos
Mixossarcoma , Doenças dos Roedores , Animais , Cricetinae , Mixossarcoma/diagnóstico , Mixossarcoma/patologia , Mixossarcoma/cirurgia , Mixossarcoma/veterinária , Mesocricetus , Imuno-Histoquímica
8.
Vet Clin Pathol ; 52(1): 11-21, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36284074

RESUMO

BACKGROUND: A novel method using a moving threshold (r-PLTmt) to determine canine r-PLTs (reticulated platelets) has been introduced for ADVIA 2120 software v6.11.7. OBJECTIVES: We aimed to evaluate absolute (ar-PLTmt) and percent (%r-PLTmt) prior to and after visual inspection of scattergrams (ar-PLTmtv, %rPLTmtv) compared with flow cytometry (flow) and to determine reference intervals (RIs) in 120 dogs. METHODS: For method comparison, 42 blood samples of healthy and thrombocytopenic dogs were included. Calculation of Spearman's rho, Bland-Altman, and Passing-Bablok analysis was performed. Coefficients of variation (CVs) were determined for three concentration levels. RESULTS: Moderate correlations between %r-PLTmt and %r-PLTmtv (rs 0.75-0.76) were seen compared with flow cytometry. The CV for medium %r-PLTs counts assessed with flow cytometry was 12.9%. Comparable CVs were obtained for ar-PLTmt (14.4%) and %r-PLTmt (15.7%), and ar-PLTmtv and %r-PLTmtv (10.9% and 12.9%, respectively). At low and high concentration levels, CVs for % and absolute r-PLTmt/rPLTmtv ranged between 23%-30% and 15%-20%. In patients with microcytic hypochromic erythrocytes, CVs for ar-PLTmt and %r-PLTmt were 36%-66%. Visual inspection of scattergrams resulted in a marked decrease in CV ranging between 15% and 20%. A proportional bias of 10.8% between %r-PLTmt and flow cytometry became lower (9.7%) after visual validation of scattergrams. Passing-Bablok analysis showed proportional and constant error. RIs for r-PLTmt and r-PLTmtv were 0.2%-3.8% and 0.6-10.2 × 109 /L and 0.3%-4.5% and 1.1-10.3 × 109 /L, respectively. Median values for %r-PLTmtv were higher in young adults (≤2 years) than in older dogs (P = 0.03). CONCLUSIONS: r-PLTmt and r-PLTmtv were moderately correlated with flow cytometry. Visual inspection of scattergrams is recommended.


Assuntos
Plaquetas , Cães , Animais , Citometria de Fluxo/veterinária
9.
Artigo em Alemão | MEDLINE | ID: mdl-36516844

RESUMO

A 10-year-old female mixed breed dog was presented for thyroid scintigraphy due to a cervical mass. Apart from 99m-Technetium-pertechnetate (Tc-pertechnetate) scintigraphy, a second scintigraphy using 99m-Technetium sestamibi (Tc-MIBI) was performed because of additional hypothyroidism suspective for a "cold" nodule and as screening for metastases.Twenty minutes following intravenous injection of 38 MBq Tc-pertechnetate, a "hot" cervical as well as a "hot" intrathoracal nodule were seen with an uptake of 8.40 and 0.25 %, respectively. The second scintigraphy was performed 20 minutes after intravenous injection of 364 MBq Tc-MIBI and 70 minutes following the first. After subtraction of pertechnetate activity and decay correction, both nodules showed an uptake of 0.99 and 0.03 %. Additionally, both thyroid lobes were visible in the thyroid loge with a weak MIBI-uptake. For both lesions, the ratio Tc-uptake/Tc-MIBI-uptake was 8.48 and 8.33, respectively.Following the extirpation of the cervical mass, histopathology revealed atrophied healthy thyroid tissue almost completely displaced by a well-differentiated follicular thyroid carcinoma.This case report describes performance, utility and calculative correction of consecutive pertechnetate- and MIBI-scan, that enable a visualization of hypofunctional thyroid tissue.Therefore and because of their similar MIBI metabolic activity, both nodules were considered to be dystopic tissue/metastases so that this dog had to be classified as prognostically less favorable WHO stabe IV. Different from human patients, both scintigraphies should be performed shortly after another in dogs in order to avoid the necessity of a second anesthetic procedure. A reliable qualitative/visual evaluation of the MIBI-scan is therefore not possible, so that a quantitative assessment using the uptake after calculative correction of the pertechnetate activity is recommended.


Assuntos
Adenocarcinoma Folicular , Doenças do Cão , Neoplasias da Glândula Tireoide , Nódulo da Glândula Tireoide , Humanos , Feminino , Cães , Animais , Pertecnetato Tc 99m de Sódio , Nódulo da Glândula Tireoide/diagnóstico por imagem , Nódulo da Glândula Tireoide/patologia , Nódulo da Glândula Tireoide/veterinária , Tecnécio , Tecnécio Tc 99m Sestamibi , Neoplasias da Glândula Tireoide/diagnóstico por imagem , Neoplasias da Glândula Tireoide/veterinária , Cintilografia , Adenocarcinoma Folicular/veterinária , Doenças do Cão/diagnóstico por imagem
10.
Animals (Basel) ; 12(15)2022 Aug 04.
Artigo em Inglês | MEDLINE | ID: mdl-35953966

RESUMO

Induction of a hypocoagulable state is imperative in the treatment of feline arterial thromboembolism. Publications in human medicine report the use of enoxaparin intravenously in selected cases. The aim of our retrospective study was to report the regain of perfusion, short-term outcome, and complications of cats treated with a novel intravenous enoxaparin protocol (1 mg/kg bolus injection followed by 3 mg/kg/day continuous infusion) combined with oral clopidogrel administration. The secondary aim was to report the monitoring of enoxaparin with anti-Xa activity. There were 36 cats included. The probability of reaching limb reperfusion was significantly (p = 0.0148) higher with anti-Xa activity within or above the target range compared to results below the target range (19/21, 90% versus 11/20, 55%). The complications observed were acute kidney injury (15/36, 42%), hemorrhage (2/36, 6%), and neurological signs (6/36, 17%). The most common causes of death/euthanasia were cardiac instability, acute kidney injury, neurological abnormalities, and limb necrosis. The hospital discharge rate was 83% (10/12) for single limb and 29% (7/24) for dual limb thrombosis; the difference was significant (p = 0.0039). The median hospitalization time for the survivors was 119.5 (95-480) h. Our study supports the use of intravenous continuous rate infusion of enoxaparin in combination with oral clopidogrel for cats with aortic thromboembolism. We report similar discharge rates and lower hemorrhage rates than previously reported with thrombolytic treatment.

11.
J Vet Pharmacol Ther ; 45(3): 265-272, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35277861

RESUMO

P-glycoprotein (P-gp) is the gene product of the multidrug resistance gene (MDR1, syn. ABCB1) that normally restricts the transfer of cortisol across the blood-brain barrier. In the absence of P-gp, cortisol access to the hypothalamus is increased and, by feedback inhibition, this finally leads to lower endogenous plasma cortisol levels in dogs with homozygous nt230(del4) MDR1 mutation (MDR1-/- mutant dogs). While a previous study only focused on plasma cortisol levels, the present study used urinary steroid hormone metabolites to analyze cortisol metabolism in MDR1-/- mutant dogs. Morning void urine was collected from 23 MDR1-/- mutant and 16 MDR1+/+ normal dogs and was subjected to targeted GC-MS steroid hormone metabolome analysis. Seven cortisol metabolites, cortisol itself, and 13 other steroid metabolites were detected. In general, all cortisol metabolites were lower in the urine of the MDR1-/- mutant dogs, with allo-tetrahydro-cortisol and ß-cortol reaching the level of significance. In addition, 11-keto-pregnanetriol levels were significantly lower in the urine of the MDR1-/- mutant dogs, indicating that also the 17alpha-OH-progesterone-derived metabolism was altered. In conclusion, the present study provides the first steroid hormone metabolome analysis in the urine of MDR1-/- mutant dogs. Significant differences in the steroid metabolome of MDR1-/- mutant dogs point to a significant role of P-gp for cortisol metabolism and excretion and so indirectly also for hypothalamic-pituitary-adrenal axis regulation in dogs.


Assuntos
Hidrocortisona , Sistema Hipotálamo-Hipofisário , Membro 1 da Subfamília B de Cassetes de Ligação de ATP/genética , Animais , Cães , Cromatografia Gasosa-Espectrometria de Massas/veterinária , Metaboloma , Sistema Hipófise-Suprarrenal , Esteroides
12.
J Vet Diagn Invest ; 34(3): 504-517, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35331075

RESUMO

A novel laser- and impedance-based point-of-care hematology analyzer (POCA), the vCell 5 (scil Animal Care), providing a complete blood count with 5-part leukocyte differential count has recently been introduced to veterinary laboratories. We evaluated the analyzer for use in dogs and cats including method comparison and assessment of linearity, carryover, and precision. Fresh blood samples from 192 healthy and diseased dogs and 159 cats were analyzed, and results were compared to reference methods (i.e., microhematocrit [PCV], Advia 2120 hematology analyzer). Total observed error (TEo) was calculated from CV, obtained at 3 concentrations, and bias%, and compared to total allowable error (TEa). For both species, excellent correlation (rs = 0.93-0.99) was seen between methods for WBC and RBC, hematocrit, hemoglobin, and platelet counts (PLT), except for feline PLT (rs = 0.79). Quality requirements (TEo < TEa) were fulfilled for WBC (TEo = 8.6-11.1%; TEa = 20%) and RBC (TEo = 3.5-7%; TEa = 10%), hematocrit (TEo = 5.7-9.4%; TEa = 10%), PCV (cat TEo = 7.8%; TEa = 10%), mean corpuscular volume (cat TEo = 5.1%; TEa = 7%), and PLT (TEo = 13.1-24.1%; TEa = 25%). Excellent linearity was demonstrated for WBC, RBC, and PLT, and hemoglobin. CVs of <2% for WBC, RBC, hematocrit, hemoglobin, and of <5% (dog) and 8% (cat) for PLT were demonstrated for values within the RI. Except for calculated variables and well-known species-specific deviations in feline PLT, scil POCA results were correlated favorably with reference method results and complied with quality requirements for cats and dogs.


Assuntos
Doenças do Gato , Doenças do Cão , Hematologia , Animais , Contagem de Células Sanguíneas/veterinária , Doenças do Gato/diagnóstico , Gatos , Doenças do Cão/diagnóstico , Cães , Impedância Elétrica , Hemoglobinas , Lasers , Sistemas Automatizados de Assistência Junto ao Leito , Reprodutibilidade dos Testes
13.
J Feline Med Surg ; 24(4): 359-365, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-34313486

RESUMO

OBJECTIVES: The aim of this study was to investigate the impact of radioiodine treatment (RIT) on the acute phase proteins (APPs) serum amyloid A (SAA), alpha-1-acid glycoprotein (AGP) and haptoglobin (Hp) in hyperthyroid cats. METHODS: Between June 2013 and November 2014, 33 hyperthyroid cats without clinical or laboratory signs of inflammatory or neoplastic disease and a body weight >2.5 kg were enrolled. Immediately before, and 12, 36, 72 h and 6 days after RIT, serum samples were obtained for determination of APP concentrations. RESULTS: Both SAA and AGP concentrations changed significantly after RIT. The concentration of AGP increased gradually after treatment with a maximum concentration at the end of the study period (median baseline 398 µg/ml; median 6 days post-RIT 562 µg/ml [P = 0.001]). A relevant >two-fold increase in AGP was seen in 8/33 (24%) cats. SAA concentration increased significantly within 12 h (baseline 9.2 µg/ml; 12 h post-RIT 22.5 µg/ml [P = 0.012]). In 7/33 (21%) cats, a clinically relevant >10-fold increase in SAA was observed. Hp concentration showed no significant change (P = 0.12). CONCLUSIONS AND RELEVANCE: RIT induced a mild, mainly not clinically relevant acute phase reaction (APR). AGP and SAA were useful APPs to determine RIT-induced APR.


Assuntos
Doenças do Gato , Hipertireoidismo , Proteínas de Fase Aguda , Animais , Doenças do Gato/radioterapia , Gatos , Hipertireoidismo/radioterapia , Hipertireoidismo/veterinária , Radioisótopos do Iodo/uso terapêutico , Orosomucoide/metabolismo , Proteína Amiloide A Sérica/metabolismo
14.
J Vet Diagn Invest ; 34(1): 42-53, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34763564

RESUMO

Rapid, accurate detection of serum amyloid A (SAA) is needed in equine practice. We validated a patient-side point-of-care (POC) assay (Stablelab; Zoetis) compared to the turbidimetric immunoassays LZ-SAA (TIA-Hum) and VET-SAA (TIA-Vet; both Eiken Chemical). Analytical performance was assessed at 3 different concentration ranges and with interferences. Inter-method comparison using 49 equine serum samples revealed a significant difference between median SAA results (p < 0.0001), with the strongest bias between the POC and TIA-Vet (median 1,093 vs. 578 mg/L). The median SAA value obtained with the TIA-Hum method was 752 mg/L. Correlation between POC/TIA-Hum and between POC/TIA-Vet was fair (rs = 0.77 and 0.69) and excellent between both TIAs (rs = 0.93). Bias between POC/TIA-Hum, POC/TIA-Vet, and TIA-Hum/TIA-Vet was -56.7%, -80.9%, and -28.2%, respectively. POC intra- and inter-assay CVs (16.1-30% and 19.8-35.5%) were higher than TIA CVs (generally <12%). Bilirubin and hemoglobin had a negative bias on POC and TIA-Vet results (-16.6 to -45.6%); addition of intralipid yielded a positive bias (35.9-77.4%). The POC had good linearity of SAA concentrations up to 10,312 mg/L (R2 = 0.92). A hook effect was present at SAA >3,000 mg/L for the POC assay. Equine serum SAA was stable over a median period of 2.5 y when stored at -80°C. Overall, there was excellent-to-moderate correlation between tests, but imprecision and hook effect of the POC, as well as bias between the methods, must be considered.


Assuntos
Imunoturbidimetria , Proteína Amiloide A Sérica , Animais , Cavalos , Humanos , Imunoturbidimetria/veterinária , Sistemas Automatizados de Assistência Junto ao Leito
15.
Artigo em Inglês | MEDLINE | ID: mdl-34861718

RESUMO

OBJECTIVE: To investigate oxidative erythrocyte damage in dogs treated with different non-steroidal anti-inflammatory drugs. MATERIAL AND METHODS: Case-controlled prospective observational study using blood obtained from dogs presenting for lameness examinations or standard surgical procedures to a private referral clinic. Sampling was performed from April 2018 to July 2019. Groups comprised dogs receiving either metamizole (dipyrone) (22 dogs), carprofen (20 dogs) or meloxicam (20 dogs) for a minimum of 10 days. Dogs with gastrointestinal hemorrhage were excluded from the study. A complete hematological, as well as a basic biochemical profile were performed in every dog. Pappenheim stained blood smears were evaluated for eccentrocytes and brilliant cresyl blue stained smears for Heinz bodies. EDTA blood was frozen at -80°C immediately after sampling for measurement of superoxide dismutase and gluthathione peroxidase activity at an external laboratory. Hemoglobin concentration, superoxide dismutase and gluthathione peroxidase activities, reticulocyte count, eccentrocyte and Heinz body numbers were determined prospectively as key parameters for further statistical assessment with Kruskal-Wallis test and Dunn's multiple comparisons test. RESULTS: Dogs receiving metamizole showed a significant increase in eccentrocyte (median 14.5/500 cells vs. 0/500 cells in the other groups, p < 0.0001) and reticulocyte number (median 191.4 × 109/l vs. 31.6-37.9 × 109/l, p < 0.0001) and a significant decrease in hemoglobin concentration (median 8.4 mmol/l vs. 10.1-10.5 mmol/l, p < 0.0003). No significant difference in superoxide dismutase and gluthathione peroxidase activities was observed between dogs receiving metamizole and the other groups. Heinz bodies were not found in any of the dogs. CONCLUSION: Treatment with metamizole for 10 or more days resulted in decreased hemoglobin concentration, eccentrocytosis and reticulocytosis in dogs in this study. This might be a sign of increased oxidative damage caused by this drug. CLINICAL SIGNIFICANCE: Prolonged metamizole therapy should be evaluated critically in patients already affected by severe illness or underlying anaemia.


Assuntos
Dipirona , Preparações Farmacêuticas , Animais , Anti-Inflamatórios não Esteroides/efeitos adversos , Cães , Eritrócitos , Estresse Oxidativo
16.
J Vet Diagn Invest ; 33(1): 35-46, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33112211

RESUMO

Point-of-care analyzers (POCAs) for quantitative assessment of bile acids (BAs) are scarce in veterinary medicine. We evaluated the Fuji Dri-Chem Immuno AU10V analyzer and v-BA test kit (Fujifilm) for detection of feline and canine total serum BA concentration. Results were compared with a 5th-generation assay as reference method and a 3rd-generation assay, both run on a bench-top analyzer. Analytical performance was assessed at 3 different concentration ranges, and with interferences. For method comparison, samples of 60 healthy and diseased cats and 64 dogs were included. Linearity was demonstrated for a BA concentration up to 130 µmol/L in cats (r = 0.99) and 110 µmol/L in dogs (r = 0.99). The analyzer showed high precision near the lower limit of quantification of 2 µmol/L reported by the manufacturer. Intra- and inter-assay coefficients of variation were < 5% for both species and all concentrations. Interferences were observed for bilirubin (800 mg/L) and lipid (4 g/L). There was excellent correlation with the reference method for feline (rs = 0.98) and canine samples (rs = 0.97), with proportional biases of 6.7% and -1.3%, respectively. However, a large bias (44.1%) was noted when the POCA was compared to the 3rd-generation assay. Total observed error was less than total allowable error at the 3 concentrations. The POCA reliably detected feline and canine BA in clinically relevant concentrations.


Assuntos
Ácidos e Sais Biliares/sangue , Doenças do Gato/diagnóstico , Gatos/sangue , Doenças do Cão/diagnóstico , Cães/sangue , Hepatopatias/veterinária , Sistemas Automatizados de Assistência Junto ao Leito , Animais , Doenças do Gato/sangue , Doenças do Cão/sangue , Imunoensaio/veterinária , Hepatopatias/sangue , Hepatopatias/diagnóstico , Estudos Prospectivos , Reprodutibilidade dos Testes
17.
BMC Vet Res ; 16(1): 147, 2020 May 20.
Artigo em Inglês | MEDLINE | ID: mdl-32434519

RESUMO

BACKGROUND: In human medicine, extremely high CRP (C-reactive protein) concentrations > 100 mg/l are indicators of bacterial infection and the need of antibiotic treatment. Similar decision limits for septic pneumonia are recommended for dogs but have not yet been evaluated for other organ systems. The aim of the retrospective study was to investigate the prevalence and evaluate dogs with CRP concentrations > 100 mg/l regarding the underlying etiology, the affected organ system and the prognostic significance. RESULTS: Prevalence of CRP > 100 mg/l was investigated in dogs presented between 2014 and 2015 and was 12%. For evaluation of etiology and organ systems, dogs with CRP > 100 mg/l presented between 2014 and 2016 were enrolled. Dogs were classified into 4 main disease categories, i.e. inflammatory, neoplastic, tissue damage or "diverse". Diseases were assigned to the affected organ system. If an organ classification was not possible, dogs were classified as "multiple". 147 dogs with CRP 101-368 mg/l were included and classified into disease categories: 86/147 (59%) with inflammatory etiology (among these, 23/86 non-infectious, 44/86 infectious (33/44 bacterial), 19/86 inflammation non-classifiable), 31/147 (21%) tissue damage, 17/147 (12%) neoplastic (all malignant) and 13/147 (9%) diverse diseases. The affected organ systems included 57/147 (39%) multiple, 30/147 (20%) trauma, 21/147 (14%) gastrointestinal tract, 10/147 (7%) musculoskeletal system, 8/147 (5%) respiratory tract, 7/147 (5%) urinary/reproductive tract, 6/147 (4%) skin/subcutis/ear, 6/147 (4%) central/peripheral nervous system and 2/147 (1%) heart. The disease group (p = 0.081) or organ system (p = 0.17) did not have an impact on CRP. Based on CRP, a detection of bacterial infection was not possible. The prognostic significance was investigated by determining the 3-months survival and hospitalization rate in a subgroup with known outcome. The 3-months survival rate was 46/73 (63%) while the majority 66/73 (90%) of patients was hospitalized. CONCLUSIONS: CRP concentrations > 100 mg/l are occasionally seen in a clinic population. They indicate a severe systemic disease of various etiologies with guarded prognosis. Extremely high CRP concentrations do not allow a conclusion of the underlying etiology or an identification of bacterial inflammation.


Assuntos
Biomarcadores/sangue , Proteína C-Reativa/análise , Doenças do Cão/sangue , Animais , Infecções Bacterianas/sangue , Infecções Bacterianas/veterinária , Doenças do Cão/etiologia , Cães , Feminino , Hospitalização/estatística & dados numéricos , Inflamação/sangue , Inflamação/veterinária , Masculino , Neoplasias/sangue , Neoplasias/veterinária , Prevalência , Prognóstico , Estudos Retrospectivos , Análise de Sobrevida
18.
Vet Clin Pathol ; 49(4): 557-566, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33617045

RESUMO

BACKGROUND: Decreased reticulocyte hemoglobin content (CHr) (Siemens ADVIA 2120) reflects iron-limited erythropoiesis (ILE). RETIC-HGB (IDEXX ProCyte Dx) is a novel marker of ILE for veterinary use. OBJECTIVES: We aimed to evaluate reference intervals (RIs) and the utility of RETIC-HGB and CHr in the diagnosis of feline ILE. MATERIALS AND METHODS: RIs were established in 59 healthy cats. Intra-assay coefficients of variation (CVs) and correlations between RETIC-HGB and CHr were assessed. Two hundred and seventy-five cats were classified as having ILE or not based on low plasma iron or low transferrin saturation along with anemia and/or altered RBC indices. CHr, RETIC-HGB, and serum amyloid A (SAA) were compared between the groups. The sensitivity and specificity of RETIC-HGB and CHr to diagnose ILE were analyzed to determine the RI lower limits. RESULTS: RIs for RETIC-HGB and CHr were 12.5-18.0 and 14.0-19.9 pg, respectively. The CV was 3% for both variables. RETIC-HGB and CHr were moderately correlated (rs = 0.59) with a bias of -1.2 picograms (pgs). Twenty of the 275 cats were classified as having ILE. Compared with non-ILE cats, ILE cats had significantly lower median RETIC-HGB (14.3 vs 15.2 pg, P = .0046) and mean CHr (14.7 vs 16.5 pg, P < .0001) values and significantly increased median SAA (44.6 vs 2.3 µg/dl, P < .0001) values. Using the lower RI limits resulted in a low sensitivity and relatively high specificity to diagnose ILE in cats. CONCLUSIONS: ILE was characterized by decreased CHr and RETIC-HGB; however, sensitivity was low. The moderate correlation between RETIC-HGB and CHr is likely due to species differences and different methodology.


Assuntos
Anemia Ferropriva/veterinária , Doenças do Gato/diagnóstico , Eritropoese , Hemoglobinas/análise , Reticulócitos/química , Anemia Ferropriva/sangue , Anemia Ferropriva/diagnóstico , Animais , Estudos de Casos e Controles , Doenças do Gato/sangue , Gatos , Contagem de Eritrócitos/veterinária , Feminino , Hematócrito/veterinária , Masculino
19.
BMC Vet Res ; 15(1): 379, 2019 Oct 29.
Artigo em Inglês | MEDLINE | ID: mdl-31664993

RESUMO

BACKGROUND: Canine idiopathic pulmonary fibrosis (CIPF) is a progressive interstitial lung disease mainly affecting old West Highland white terriers (WHWTs). The aetiology of CIPF is currently unknown and pathogenesis poorly understood. A genetic basis is strongly suspected based on the breed predisposition. CIPF shares clinical and pathological features with human IPF. In human IPF, coagulation disorders favouring a local and systemic pro-thrombotic state have been demonstrated in association with disease severity and outcome. The aim of this study was to compare the systemic haemostatic, fibrinolytic and inflammatory profiles of WHWTs affected with CIPF with breed-matched controls (CTRLs). Additionally, data collected in both groups were interpreted with regard to the reference intervals (when available) to assess possible pro-thrombotic features of the WHWT breed that may be related to CIPF predisposition. A total of 14 WHWTs affected with CIPF and 20 CTRLs were included. RESULTS: WHWTs affected with CIPF had prolonged activated partial thromboplastine time in comparison with CTRLs (12.2 ± 0.9 s vs. 11.5 ± 0.7 s, P = 0.028), whereas results obtained in both groups were all within reference ranges. There was no significant difference between groups for the other factors assessed including plasmatic concentrations of fibrinogen, D-dimers concentration, antithrombin III activity, protein S and protein C activities, anti-factor Xa activity, activated protein C ratio, serum C-reactive protein concentration, and rotational thromboelastometry indices. Platelet count and plasmatic fibrinogen concentration were found to be above the upper limit of the reference range in almost half of the WHWTs included, independently of the disease status. CONCLUSIONS: Results of this study provide no clear evidence of an altered systemic haemostatic, fibrinolytic or inflammatory state in WHWTs affected with CIPF compared with CTRLs. The higher platelet counts and fibrinogen concentrations found in the WHWT breed may serve as predisposing factors for CIPF or simply reflect biological variation in this breed.


Assuntos
Doenças do Cão/sangue , Fibrose Pulmonar/veterinária , Animais , Proteínas Sanguíneas , Estudos de Casos e Controles , Doenças do Cão/genética , Cães , Contagem de Eritrócitos , Feminino , Predisposição Genética para Doença , Hematócrito , Hemoglobinas , Hemostáticos/sangue , Contagem de Leucócitos , Masculino , Contagem de Plaquetas , Fibrose Pulmonar/sangue , Fibrose Pulmonar/genética , Tromboelastografia
20.
Front Vet Sci ; 6: 149, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31157246

RESUMO

The aim of this prospective study was to compare quality of blood products produced either by a novel gravity-driven hollow-fiber separation system (HF) or by centrifugation (C). Whole blood was obtained from 31 healthy non-greyhound canine blood donors and separated into fresh frozen plasma and packed red blood cells using either HF or C in a university teaching hospital. Red blood cell (RBC) count, albumin and fibrinogen concentration, prothrombin time (PT), activated partial thromboplastin time (aPTT) and coagulation factor activity (FV, FVIII), von Willebrand Factor (vWF), and antithrombin activity were assessed. Plasma obtained with the HF showed a significantly higher median PT (9.4 vs. 7.9 s, P = 0.0006) and aPTT (14.9 vs. 13.1 s, P = 0.0128) than plasma prepared with C. Lower albumin (21.7 vs. 23.5 g/l, P = 0.0162) and fibrinogen (1.0 vs. 1.5 g/l, P = 0.0005) concentrations and activities of FV (105 vs. 114%, P = 0.0021) and antithrombin (104 vs. 117%, P = 0.0024) were seen in blood products obtained with the HF. In contrast, vWF was not affected by the method of plasma separation. Compared to HF, RBC count as well as hematocrit were not significantly higher (8.0 vs. 8.9 1012/l, P = 0.1308; 0.57 vs. 0.62 l/l, P = 0.0736) when blood products were prepared with C. In conclusion, higher quality of blood products especially regarding coagulation parameters and RBCs was achieved by using C compared to HF. Despite the statistical significances, however, the clinical relevance has to be further elucidated. Nevertheless, HF provides an alternative to produce blood products if a centrifuge is not available.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA