Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 38
Filtrar
2.
Endosc Ultrasound ; 6(4): 241-244, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28685744

RESUMO

BACKGROUND: Fusion imaging is an accepted method in abdominal imaging allowing a simultaneous display of reference imaging with a live ultrasound (US) investigation. For prostate cancer, promising results have been published for endorectal US (ERUS)-guided biopsy of suspicious lesions in magnetic resonance imaging (MRI). To our knowledge, no other indication for the fusion of ERUS with MRI has been reported so far. METHODS: We report on three patients scheduled for ERUS due to anorectal fistulae after treatment (n = 2) or rectal carcinoma (n = 1), which were scheduled for real-time virtual onography (RVS), a method for the fusion of MRI imaging with US. RESULTS: In all patients, RVS was successful. The course of the fistulae could be defined and the success of the treatment could be confirmed. In the patient with rectal carcinoma, the lymph nodes suspicious in MRI could be identified. CONCLUSIONS: MRI/ERUS fusion has the potential for follow-up of anorectal fistulae and abscesses, and staging of anal and rectal tumors.

3.
Handchir Mikrochir Plast Chir ; 49(1): 60-63, 2017 Feb.
Artigo em Alemão | MEDLINE | ID: mdl-28423442

RESUMO

Atypical lipomatous tumours (ALT) are rare semi-malignant adipose tissue tumours with the potential to transform into sarcomas. They may occur throughout the body, although the hands are very rarely involved. We present the case of a 49-year-old man with a lipomatous tumour measuring 8×4 cm at the dorsum of the right thumb. MRI demonstrated an inhomogeneous signal after contrast medium application. The tumour was excised in its entirety. Since histology confirmed the diagnosis of an ALT, the thumb was irradiated. The patient remained free of recurrence. An ALT has to be suspected if a lipomatous tumour is very large. We recommend an MRI prior to surgery in tumours larger than 5 cm. Excision should follow oncologic principles.


Assuntos
Mãos/cirurgia , Lipoma/diagnóstico , Lipoma/cirurgia , Neoplasias de Tecidos Moles/diagnóstico , Neoplasias de Tecidos Moles/cirurgia , Polegar/cirurgia , Terapia Combinada , Seguimentos , Mãos/patologia , Humanos , Lipoma/patologia , Lipoma/radioterapia , Imageamento por Ressonância Magnética , Masculino , Margens de Excisão , Pessoa de Meia-Idade , Radioterapia Adjuvante , Neoplasias de Tecidos Moles/patologia , Neoplasias de Tecidos Moles/radioterapia , Polegar/patologia , Carga Tumoral
4.
Med Princ Pract ; 25(5): 399-407, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27318740

RESUMO

Contrast-enhanced ultrasound (CEUS) represents a significant breakthrough in sonography. Due to US contrast agents (UCAs) and contrast-specific techniques, sonography offers the potential to show enhancement of liver lesions in a similar way as contrast-enhanced cross-sectional imaging techniques. The real-time assessment of liver perfusion throughout the vascular phases, without any risk of nephrotoxicity, represents one of the major advantages that this technique offers. CEUS has led to a dramatic improvement in the diagnostic accuracy of US and subsequently has been included in current guidelines as an important step in the diagnostic workup of focal liver lesions (FLLs), resulting in a better patient management and cost-effective therapy. The purpose of this review was to provide a detailed description of contrast agents used in different cross-sectional imaging procedures for the study of FLLs, focusing on characteristics, indications and advantages of UCAs in clinical practice.


Assuntos
Meios de Contraste/uso terapêutico , Hepatopatias/diagnóstico por imagem , Hepatopatias/diagnóstico , Ultrassonografia/métodos , Administração Intravenosa/métodos , Meios de Contraste/administração & dosagem , Meios de Contraste/efeitos adversos , Meios de Contraste/farmacocinética , Humanos , Imageamento por Ressonância Magnética/métodos , Tomografia Computadorizada por Raios X
5.
Ultrasound Med Biol ; 41(4): 975-81, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25701519

RESUMO

Zenker's diverticulum (ZD) may be misdiagnosed on conventional ultrasound as a thyroid nodule or other lesion. A barium esophagram is usually used to confirm the diagnosis; however, this procedure exposes the patient to radiation. The aim of this study was to evaluate the feasibility of using swallow contrast-enhanced ultrasound (swallow-CEUS) to diagnose ZD. Ten consecutive patients with ZD (7 men and 3 women, aged 67 ± 11 y) were included in the study. In 4 patients, ZD was incidentally found on head and neck ultrasound, and in 6 patients, ZD was suspected because of dysphagia. All lesions could be detected on conventional ultrasound before swallow-CEUS. Ten healthy volunteers (8 men and 2 women, aged 60 ± 12 y) were chosen as a control group. Written informed consent was obtained. With the patient in the sitting or upright position, conventional ultrasound was performed first to image the lesion, then the patient was asked to swallow ultrasound contrast agent (UCA) (2-4 drops of SonoVue diluted with about 200 mL of tap water). Transity of the contrast agent in the esophagus was imaged with CEUS. Retention of the UCA in the diverticulum was monitored for at least 3 min. All patients underwent a barium esophagram as the gold standard. Swallow-CEUS revealed that in all patients (100%), the UCA was transported from the pharynx to the esophagus while the patient swallowed. ZD appeared as a pouch-shaped structure at the posterior pharyngo-esophageal junction that retained UCA longer than 3 min. The barium esophagram confirmed the diagnosis of ZD in all patients. For the 10 volunteers, no abnormal structure (retaining UCA) was detected during or after swallowing of UCA. With the advantages of no radiation and bedside availability, swallow-CEUS may become a method of choice in confirmation of the diagnosis of ZD, especially when ZD is suspected on conventional ultrasound.


Assuntos
Meios de Contraste/administração & dosagem , Deglutição , Aumento da Imagem/métodos , Fosfolipídeos/administração & dosagem , Hexafluoreto de Enxofre/administração & dosagem , Divertículo de Zenker/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Esôfago/diagnóstico por imagem , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Ultrassonografia
7.
Acad Radiol ; 16(11): 1386-92, 2009 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-19643636

RESUMO

RATIONALE AND OBJECTIVES: Pancreatic lesions are frequently detected in pancreatic phase only, which may lead to false negative findings in CT-guided biopsies. We evaluated the accuracy and complication rate of CT guided biopsies of pancreatic lesions with i.v.-contrast application following needle placement in comparison to biopsy after contrast enhanced CT. MATERIALS AND METHODS: In 30 patients planning and needle placement was performed on the basis of a native planning CT and prior diagnostic CT or MRT. After needle placement contrast enhanced CT was performed to confirm needle course and adjusted if necessary (group 1). In 30 additional patients biopsy was planned based on contrast enhanced CT and needle was placed in the lesion. Control scans confirmed correct needle position (group 2). An 18G coaxial system was used for both groups. Statistical analysis was performed with Student's t and Fisher's exact test for comparison of lesion size, location as well as accuracy and complication rates. RESULTS: Mean lesion size was significantly smaller in group 1 (31 mm vs. 39 mm; p = 0.02). Diagnostic accuracy and sensitivity for malignancy in group 1 was 93% and 92% versus 80% and 77% in group 2. Complications related to the procedure, i.e. haematoma (n = 5, group 1/n = 2, group 2) and pain (n = 0, group 1/n = 2, group 2) did not statistically differ. CONCLUSION: CT-guided biopsy of pancreatic lesions with i.v.-contrast application following needle placement is a reliable method and provides superior accuracy compared to biopsies performed after contrast enhanced planning CT.


Assuntos
Biópsia por Agulha/métodos , Iopamidol/análogos & derivados , Neoplasias Pancreáticas/diagnóstico por imagem , Neoplasias Pancreáticas/patologia , Cirurgia Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Meios de Contraste/administração & dosagem , Feminino , Humanos , Injeções Intravenosas , Iopamidol/administração & dosagem , Masculino , Pessoa de Meia-Idade , Agulhas , Punções/métodos , Radiografia Intervencionista/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
8.
Invest Radiol ; 44(5): 257-64, 2009 May.
Artigo em Inglês | MEDLINE | ID: mdl-19550377

RESUMO

OBJECTIVES: Noninvasive imaging is increasingly accepted for the evaluation of atherosclerotic disease of the carotid arteries. We sought to evaluate the feasibility of a low-contrast media volume protocol for carotid computed tomography angiography (CTA) using a 128-slice-spiral-computed tomography scanner with a gantry rotation time of 300 milliseconds. METHODS AND MATERIALS: Thirty consecutive patients underwent CTA for the evaluation of the carotid vessels, with a 128-section scanner. Fifteen patients were examined with a standard volume contrast injection protocol (group A): 80 mL of contrast material (CM) were injected at 5 mL/s using the test bolus method to assess individual transit time. Another 15 patients were examined with a low-volume contrast media protocol (group B): 30 mL CM were injected at 4 mL/s using bolus tracking to trigger the CTA acquisition. In both groups, contrast administration was followed by a saline flush. Image quality and segmental vascular enhancement as well as the presence and degree of arterial stenosis were independently evaluated by 2 radiologists. Venous enhancement and streak artifacts at the thoracic inlet because of highly concentrated CM in the subclavian veins were evaluated in both groups. Kappa statistic and Pearson correlation coefficient were used to quantify interobserver variability. Qualitative data were compared using the Wilcoxon signed rank test and student t test was used to investigate differences in segmental vessel attenuation. RESULTS: All studies were of diagnostic quality in both groups. Interobserver agreement was high (kappa = 0.82, group A; kappa = 0.78, group B). Attenuation measurement showed excellent interobserver correlation in both groups (r > 0.9). Mean enhancement values were slightly higher in group A, but without statistical significance when averaged for all segments (P = 0.06). Streak artifacts impaired evaluation of 13 adjacent arterial segments in 8 patients at the level of the thoracic inlet in group A. In group B, only 1 segment was rated insufficient by both radiologists. Venous enhancement was significantly lower in group B (P = 0.04). The low-contrast protocol proved to be the more robust method with constant high arterial enhancement, less streak artifacts at the thoracic inlet, and less venous overlay. CONCLUSION: Using the latest CT technology, optimal depiction of the craniocervical arteries can be archived with a low-volume (30 mL) CM protocol.


Assuntos
Angiografia/métodos , Anticorpos Monoclonais/administração & dosagem , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/tratamento farmacológico , Artérias Carótidas/diagnóstico por imagem , Meios de Contraste/administração & dosagem , Tomografia Computadorizada por Raios X/métodos , Inibidores da Angiogênese/administração & dosagem , Animais , Anticorpos Monoclonais Humanizados , Antineoplásicos/administração & dosagem , Bevacizumab , Linhagem Celular Tumoral , Relação Dose-Resposta a Droga , Feminino , Humanos , Ratos , Ratos Nus , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Fatores de Tempo , Resultado do Tratamento
9.
Abdom Imaging ; 34(1): 75-80, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-17934772

RESUMO

The purpose was to assess capabilities of the multidetector-row computed tomography (MDCT) with multiplanar reformations (MPR) for predicting of pancreatic adenocarcinoma resectability. Forty-eight patients deemed to have resectable pancreatic adenocarcinoma after assessment using biphasic MDCT with MPRs underwent surgery for potential tumor resection. Imaging findings were retrospectively evaluated for tumor resectability and correlated with surgical and pathological results. Curative resection was successful in 44 of 48 patients. The positive predictive value for tumor resectability made up 91% with four false-negative results. The reasons for unresectability were venous involvement (1), small liver metastases (2) and peritoneal involvement associated with small metastases to lymph nodes (1). MDCT yielded a negative predictive value of 99% (286 of 288 vessels) for detection of vascular invasion. Our results indicate the tendency towards improved prediction of resectability using MDCT compared to single-detector CT.


Assuntos
Adenocarcinoma/diagnóstico por imagem , Neoplasias Pancreáticas/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adenocarcinoma/patologia , Adenocarcinoma/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Metástase Neoplásica , Neoplasias Pancreáticas/patologia , Neoplasias Pancreáticas/cirurgia , Pancreaticoduodenectomia , Valor Preditivo dos Testes , Resultado do Tratamento
10.
Circulation ; 114(22): 2334-41; quiz 2334, 2006 Nov 28.
Artigo em Inglês | MEDLINE | ID: mdl-17088461

RESUMO

BACKGROUND: Multidetector computed tomographic angiography (MDCT) has been shown to allow detection of coronary artery bypass graft (CABG) occlusions and stenoses. However, the assessment of native coronary arteries in addition to CABG has thus far not been sufficiently validated. METHODS AND RESULTS: Fifty patients with a total of 138 CABG (34 mammary grafts, 3 radial grafts, 101 venous grafts) were investigated by MDCT (0.6-mm collimation, 32 detector rows, 2 focal points, 330-ms rotation) 9 to 252 months (mean, 106 months) after surgery. CABG and all native coronary arteries with a diameter of > 1.5 mm were evaluated for the presence of significant stenoses (> or = 50% diameter reduction). Results were compared with quantitative coronary angiography. By MDCT, all CABG were evaluable and were correctly classified as occluded (n=38) or patent (n=100). Sensitivity for stenosis detection in patent grafts was 100% (16/16) with a specificity of 94% (79/84). For the per-segment evaluation of native coronary arteries and distal runoff vessels, sensitivity in evaluable segments (91%) was 86% (87/101) with a specificity of 76% (354/465). If evaluation was restricted to nongrafted arteries and distal runoff vessels, sensitivity was 86% (38/44) with a specificity of 90% (302/334). On a per-patient basis, classifying patients with at least 1 detected stenosis in a CABG, a distal runoff vessel, or a nongrafted artery or with at least 1 unevaluable segment as "positive," MDCT yielded a sensitivity of 97% (35/36) and specificity of 86% (12/14). CONCLUSIONS: We found that 64-slice MDCT permits the evaluation of bypass grafts and the assessment of the native coronary arteries for the presence of stenosis.


Assuntos
Angiografia Coronária , Ponte de Artéria Coronária , Tomografia Computadorizada Espiral/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Humanos , Processamento de Imagem Assistida por Computador , Anastomose de Artéria Torácica Interna-Coronária , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
11.
Eur Heart J ; 27(21): 2567-72, 2006 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-17035252

RESUMO

AIMS: We investigated the feasibility of assessing coronary artery stent restenosis using a new generation 64-slice multi-detector computed tomography-scanner (MDCT) in comparison to conventional quantitative angiography. METHODS AND RESULTS: MDCT was performed in 64 consecutive patients (mean age 58+/-10 years) with previously implanted coronary artery stents (102 stented lesions: mean stent diameter 3.17+/-0.38 mm). Each stent was classified as 'evaluable' or 'unevaluable', and in evaluable stents, the presence of in-stent restenosis (diameter reduction >50%) was determined visually. Results were verified against invasive, quantitative coronary angiography. Fifty-nine stented lesions (58%) were classified as evaluable in MDCT. The mean diameter of evaluable stents was 3.28+/-0.40 mm, whereas the mean diameter of non-evaluable stents was 3.03+/-0.31 mm (P=0.0002). Overall, six of 12 in-stent restenoses were correctly detected by MDCT [50% sensitivity (confidence interval 22-77%)] and in 51 of 90 lesions, in-stent restenosis was correctly ruled out [57% specificity (46-67%)]. In evaluable stents, six of seven in-stent restenoses were correctly detected, and the absence of in-stent stenosis was correctly identified in 51 of 52 cases [sensitivity 86% (42-99%) and specificity 98% (88-100%)]. CONCLUSION: Stent type and diameter influence evaluability concerning in-stent restenosis by MDCT. The rate of assessable stents is low, but in evaluable stents, accuracy for detection of in-stent restenosis can be high.


Assuntos
Reestenose Coronária/diagnóstico por imagem , Stents , Tomografia Computadorizada por Raios X/métodos , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Falha de Prótese
12.
Radiother Oncol ; 81(2): 190-5, 2006 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-17050019

RESUMO

BACKGROUND AND PURPOSE: Inclusion of regional lymph nodes usually is indicated when treating upper gastrointestinal malignancies. Lymphatics follow the large vessels of this region. Vascular variability with consequences for planning treatment volume (PTV) was studied. MATERIALS AND METHODS: Upper abdominal metric relationship of the vascular origins was analysed in CT scans in 104 patients to estimate its influence on PTV variability. PTV volumes were calculated based on these. Additionally, the PTV size of 3D plans of 34 patients with pancreatic adenocarcinoma (PDAC) was analysed depending on different PTV definitions. RESULTS: Vascular origin varied most for the inferior mesenteric artery (IMA) with substantial PTV size differences. Volumetric variability was analysed for PDAC (IMA versus renal hilum as caudal margin). Additional PTV for IMA was < 100 cc (median) but ranged up to 350 cc in CT (100-199 ml in 14/34 and > 200 ml in 3/34 patients). Data from treatment planning confirmed this observation. CONCLUSIONS: Considerable vascular and lymphatic variability obliges to base PTV on the individual vascular anatomy. For most patients the caudal PTV margin for PDAC can safely be set at the IMA. But PTV should be restricted when the additional volume would lead to a significant increase to avoid haematotoxicity from concomitant gemcitabine which is proportional with PTV size. The risk of kidney toxicity is also subject to PTV expansion in the caudal direction.


Assuntos
Adenocarcinoma/radioterapia , Linfonodos/diagnóstico por imagem , Vasos Linfáticos/diagnóstico por imagem , Neoplasias Pancreáticas/radioterapia , Planejamento da Radioterapia Assistida por Computador , Desoxicitidina/efeitos adversos , Desoxicitidina/análogos & derivados , Desoxicitidina/uso terapêutico , Feminino , Humanos , Imageamento Tridimensional , Linfonodos/anatomia & histologia , Vasos Linfáticos/anatomia & histologia , Masculino , Radiossensibilizantes/efeitos adversos , Radiossensibilizantes/uso terapêutico , Radiografia Abdominal , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Gencitabina
13.
Eur J Radiol ; 57(3): 336-44, 2006 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-16446072

RESUMO

PURPOSE: To investigate the ability of 16-slice multidetector-row computed tomography (MDCT) to visualize coronary artery bypass graft (CABG) patency and to detect bypass stenoses. MATERIALS AND METHODS: Thirty-two patients with 94 grafts (20 mammary artery grafts, 74 venous grafts) were investigated by 16-slice MDCT using a scan protocol with 12 x 0.75 mm slice collimation (pitch 0.3), 420 ms rotation time and simultaneous electrocardiogram (ECG)-registration. One hundred milliliters iodinated contrast agent were injected with a delay according to the individually determined contrast agent transit time. Patients with heart rates above 60 bpm received oral beta-blockade. Cross-sectional images with a slice width of 1.0 mm (0.5 mm increment) were reconstructed using an ECG-gated half-scan reconstruction or a multisegment reconstruction algorithm depending on the heart rate. Bypass grafts were evaluated concerning patency and presence of stenoses > or = 50% diameter reduction on cross-sectional images, multiplanar reformations and maximum intensity projections by two independent observers. Results were compared to coronary bypass angiography. RESULTS: Sixteen-slice MDCT results were compared to those of invasive coronary angiography concerning absence or presence of bypass graft occlusion or relevant stenosis > or = 50% lumen reduction. Coronary CT angiography (CTA) permitted detection of bypass occlusion with 100% sensitivity (28/28) and 98% specificity (64/65). Seventy-eight percent (observer 1) and 84% (observer 2) of all patent grafts were found to be evaluable concerning presence or absence of stenosis. In 34 of 40 (observer 1) and 38 of 43 (observer 2) bypass grafts, high-grade stenoses were correctly ruled out (specificity 85% versus 88%, sensitivity 80% and 82%). Yet, if all patients with either unevaluable grafts/graft anastomosis or relevant graft stenosis were excluded, only 8/32 patients (25%) had fully diagnostic "negative" graft-CTA. According to Kappa statistics, agreement between the observers was 1.0 and 0.93 concerning occlusion and relevant stenosis, respectively. CONCLUSION: Sixteen-slice coronary CTA with sub-millimeter spatial resolution and premedication with oral beta-blockade permits non-invasive assessment of coronary artery bypass grafts with decreasing numbers of unevaluable graft segments. However, patient-based analysis reveals that only a relatively small number of patients ("negative" and completely evaluable graft-CTA) truly profits from noninvasive work-up and could be spared invasive angiography.


Assuntos
Angiografia Coronária , Ponte de Artéria Coronária , Reestenose Coronária/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Grau de Desobstrução Vascular , Adulto , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste , Eletrocardiografia , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Sensibilidade e Especificidade
14.
Am J Cardiol ; 97(3): 343-8, 2006 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-16442393

RESUMO

Eighty-four patients with suspected coronary artery disease were studied to determine the accuracy of noninvasive coronary angiography using a multidetector computed tomographic scanner with 64- x 0.6-mm collimation and 330-ms gantry rotation. All coronary artery segments with a diameter >1.5 mm were assessed with respect to stenoses >50% decreased diameter. Results were compared with quantitative coronary angiographic findings. After exclusion of unevaluable coronary segments (4%), multidetector computed tomography demonstrated a sensitivity of 93%, a specificity of 97%, and a negative predictive value of 100% in a per-segment analysis. In a per-artery analysis, 15 of 336 arteries (4%) were unevaluable. Sensitivity and specificity in evaluable arteries were 95% and 93%, respectively. In a per-patient analysis (81 of 84 patients included), sensitivity and specificity were 96% and 91%, respectively.


Assuntos
Angiografia Coronária , Estenose Coronária/diagnóstico por imagem , Tomografia Computadorizada Espiral/instrumentação , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes
15.
J Interferon Cytokine Res ; 26(1): 8-13, 2006 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-16426143

RESUMO

Interferon-alpha (IFN-alpha) is well established in the treatment of neuroendocrine carcinomas (NEC). Treatment is accompanied by fatigue and flu-like symptoms. In patients with chronic hepatitis C, pegylated IFN (PEGIFN) leads to improved antiviral efficacy and good tolerability. Our aim was to assess the efficacy and tolerability of PEG-IFN on the management of patients with well-differentiated NEC of the gastroenteropancreatic system. In 17 patients, the effect of PEG-IFN-alpha2b was studied. After first-line octreotide treatment, IFN-alpha was added at the time of tumor progression. Six patients were switched from conventional IFN-alpha, and 11 patients were IFN naive. Inhibition of tumor growth, including stabilization of disease, occurred in 13 of 17 patients, and biochemical and symptomatic responses were seen in 7 of 10 patients with functionally active tumors. Tolerability of PEG-IFN-alpha2b was much better than that of IFN-alpha. Fatigue occurred in 59% of all patients but was mild in severity. Eleven of thirteen patients who had a benefit remained on therapy for a median time of 20 months (range 6-30 months). PEG-IFN-alpha2b provides symptomatic and antiproliferative efficacy in patients with NEC. Better tolerability of PEG-IFN-alpha2b improved patients' compliance, justifying its use in patients who do not tolerate conventional IFN-alpha treatment.


Assuntos
Carcinoma Neuroendócrino/tratamento farmacológico , Neoplasias Gastrointestinais/tratamento farmacológico , Interferon-alfa/uso terapêutico , Neoplasias Pancreáticas/tratamento farmacológico , Idoso , Antineoplásicos Hormonais/uso terapêutico , Carcinoma Neuroendócrino/patologia , Progressão da Doença , Feminino , Neoplasias Gastrointestinais/patologia , Humanos , Interferon alfa-2 , Interferon-alfa/efeitos adversos , Masculino , Pessoa de Meia-Idade , Octreotida/uso terapêutico , Neoplasias Pancreáticas/patologia , Cooperação do Paciente , Polietilenoglicóis , Proteínas Recombinantes , Resultado do Tratamento
16.
Int J Cardiovasc Imaging ; 22(3-4): 537-41, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-16273312

RESUMO

Left ventricular (LV) aneurysm after myocardial infarction without any clinical symptoms is a rare complication of coronary artery disease. In most cases, especially in young people, this complication is diagnosed too late, after rupture into the pericardial cavity has occurred. Here we present the successful surgical repair of a large LV aneurysm in a 35-year-old man. We could visualize this aneurysm and the coronary arteries non-invasively by contrast-enhanced 16-slice multi-detector row spiral computed tomography (MDCT).


Assuntos
Aneurisma Roto/diagnóstico por imagem , Procedimentos Cirúrgicos Cardíacos , Aneurisma Cardíaco/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Adulto , Aneurisma Roto/patologia , Aneurisma Roto/cirurgia , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/patologia , Doença da Artéria Coronariana/cirurgia , Aneurisma Cardíaco/patologia , Aneurisma Cardíaco/cirurgia , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/cirurgia , Humanos , Masculino , Ruptura Espontânea , Resultado do Tratamento
17.
Int J Cardiol ; 111(3): 430-5, 2006 Aug 28.
Artigo em Inglês | MEDLINE | ID: mdl-16271776

RESUMO

BACKGROUND: We investigated the potential of 16-slice multi-detector row spiral CT (MDCT) with retrospective ECG-gating for evaluation of coronary artery anomalies. METHODS: A total of 35 patients (23 men, 12 women, 19-81 years) in whom anomalous coronary arteries had been detected by invasive coronary angiography underwent MDCT (Sensation 16, Siemens, Germany). During one breathhold, a contrast-enhanced (90 ml, 5 ml/s) volume data set of the heart was acquired (16x0.75mm collimation, gantry rotation 375 ms). Images were reconstructed with a slice thickness of 1.0 mm in 0.5-mm intervals using retrospective ECG-gated reconstruction. The 35 data sets and 80 data sets of patients with angiographically normal coronary anatomy were analysed in random order concerning the origin and course of the coronary arteries. The results were compared to invasive coronary angiography. RESULTS: All patients with coronary artery anomalies and all controls with normal coronary anatomy were identified by MDCT. In addition, the origins and course concerning their anatomical relationship to adjacent cardiac structures were visualized in all patients, including right-sided origin of the left main (n=10), left anterior descending coronary artery (n=4) or left circumflex coronary artery (n=10); left-sided origin of the right coronary artery (n=6); four coronary fistula to the pulmonary artery (two from the left anterior descending, one from the right coronary artery, one from the left main), and one fistula from the circumflex coronary artery to the left atrium CONCLUSIONS: The study demonstrates that MDCT is a reliable noninvasive technique to identify and define anomalous coronary arteries and their course.


Assuntos
Angiografia Coronária/métodos , Anomalias dos Vasos Coronários/diagnóstico por imagem , Tomografia Computadorizada Espiral , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Intensificação de Imagem Radiográfica
18.
Int J Gastrointest Cancer ; 35(3): 179-85, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-16110119

RESUMO

BACKGROUND: Well-differentiated neuroendocrine tumors are treated primarily with somatostatin analogs and interferon-alpha. It is not clear what therapy should be applied after failed biotherapy. Our aim was to establish whether patients whose tumors rapidly progress under biotherapy may benefit from chemotherapy. PATIENTS AND METHODS: In 10 patients with metastatic neuroendocrine tumors (4 foregut, 3 midgut, 1 retroperitoneal, and 2 of unknown origin) streptozotocin and doxorubicin were used as second-line or third-line therapy. Tumor response was assessed by computed tomography of the abdomen and thorax and measurement of tumor secretion products (serum chromogranin A, urinary 5-hydroxyindoleacetic acid). RESULTS: Three patients showed a radiological response over a mean time of 30 mo (range: 7-67 mo). Median survival after initiation of chemotherapy was 50 mo in patients with a response and 8 mo in non-responders. Three patients developed major side effects (nephrotoxicity, diabetes, and encephalopathy). CONCLUSION: Streptozotocin and doxorubicin produce poor response rates in patients with progressive neuroendocrine tumors after failed biotherapy, but may prolong life in those patients who show a tumor response.


Assuntos
Protocolos de Quimioterapia Combinada Antineoplásica/uso terapêutico , Tumores Neuroendócrinos/tratamento farmacológico , Adulto , Protocolos de Quimioterapia Combinada Antineoplásica/efeitos adversos , Progressão da Doença , Doxorrubicina/administração & dosagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Metástase Neoplásica , Tumores Neuroendócrinos/patologia , Estreptozocina/administração & dosagem , Análise de Sobrevida
19.
Int J Radiat Oncol Biol Phys ; 62(4): 1021-9, 2005 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-15990004

RESUMO

PURPOSE: In chemoradiation for pancreatic carcinoma three-dimensional target volume definitions could maximize tolerability and therapeutic effect at the same time because toxicity correlates with treatment volume. We aimed to define guidelines for elective treatment of nodal areas based on pathologic nodal involvement to optimize treatment volume for this tumor. METHODS AND MATERIALS: Pathologic patterns of regional nodal spread in 175 patients who underwent primary pancreatoduodenectomy with > or =10 assessed nodes and literature data on para-aortic spread were the base of the definition of the target volume. Significant correlations between spread to lymphatic areas and tumor characteristics were determined using Fisher's exact test. Computed tomography scans and a Pinnacle3 (Philips, Best, The Netherlands) system were used for treatment planning. RESULTS: Among 175 resected tumors without pretreatment, 76% had regional nodal metastasis and 22% had spread to distant nodes. High-risk lymphatic areas were identified and selected for elective treatment. A standardized planning procedure was derived and tested under treatment conditions. CONCLUSIONS: Histopathologic data allowed us to develop recommendations for standardized treatment planning for ductal carcinoma of the pancreatic head. These are proposed for quality assurance in multicenter studies and routine use.


Assuntos
Carcinoma Ductal Pancreático/radioterapia , Irradiação Linfática/normas , Neoplasias Pancreáticas/radioterapia , Adulto , Idoso , Idoso de 80 Anos ou mais , Carcinoma Ductal Pancreático/secundário , Carcinoma Ductal Pancreático/cirurgia , Feminino , Humanos , Excisão de Linfonodo , Irradiação Linfática/métodos , Metástase Linfática , Masculino , Pessoa de Meia-Idade , Neoplasias Pancreáticas/patologia , Neoplasias Pancreáticas/cirurgia , Pancreaticoduodenectomia , Guias de Prática Clínica como Assunto , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Radioterapia Conformacional/normas
20.
Rontgenpraxis ; 55(6): 229-33, 2005.
Artigo em Alemão | MEDLINE | ID: mdl-15906593

RESUMO

The implementation of 64-slice scanners allows for isotropic imaging with shortened acquisition time. Beam-hardening and spiral artifacts can be reduced by using sophisticated tube technology with so called double-z-sampling. The following article is meant to provide a brief overview concerning substantial changes as they could be witnessed in clinical routine using a 64-slice scanner, with special focus on CT-angiography in general and CT-angiography of the coronaries.


Assuntos
Aumento da Imagem/instrumentação , Processamento de Imagem Assistida por Computador/instrumentação , Imageamento Tridimensional/instrumentação , Avaliação da Tecnologia Biomédica , Tomografia Computadorizada Espiral/instrumentação , Angiografia/instrumentação , Artefatos , Angiografia Coronária/instrumentação , Humanos , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...